272 resultados para Radiographic Image Interpretation, Computer-Assisted
Resumo:
We propose a deep study on tissue modelization andclassification Techniques on T1-weighted MR images. Threeapproaches have been taken into account to perform thisvalidation study. Two of them are based on FiniteGaussian Mixture (FGM) model. The first one consists onlyin pure gaussian distributions (FGM-EM). The second oneuses a different model for partial volume (PV) (FGM-GA).The third one is based on a Hidden Markov Random Field(HMRF) model. All methods have been tested on a DigitalBrain Phantom image considered as the ground truth. Noiseand intensity non-uniformities have been added tosimulate real image conditions. Also the effect of ananisotropic filter is considered. Results demonstratethat methods relying in both intensity and spatialinformation are in general more robust to noise andinhomogeneities. However, in some cases there is nosignificant differences between all presented methods.
Resumo:
BACKGROUND: The outcome of diffuse large B-cell lymphoma has been substantially improved by the addition of the anti-CD20 monoclonal antibody rituximab to chemotherapy regimens. We aimed to assess, in patients aged 18-59 years, the potential survival benefit provided by a dose-intensive immunochemotherapy regimen plus rituximab compared with standard treatment plus rituximab. METHODS: We did an open-label randomised trial comparing dose-intensive rituximab, doxorubicin, cyclophosphamide, vindesine, bleomycin, and prednisone (R-ACVBP) with subsequent consolidation versus standard rituximab, doxorubicin, cyclophosphamide, vincristine, and prednisone (R-CHOP). Random assignment was done with a computer-assisted randomisation-allocation sequence with a block size of four. Patients were aged 18-59 years with untreated diffuse large B-cell lymphoma and an age-adjusted international prognostic index equal to 1. Our primary endpoint was event-free survival. Our analyses of efficacy and safety were of the intention-to-treat population. This study is registered with ClinicalTrials.gov, number NCT00140595. FINDINGS: One patient withdrew consent before treatment and 54 did not complete treatment. After a median follow-up of 44 months, our 3-year estimate of event-free survival was 81% (95% CI 75-86) in the R-ACVBP group and 67% (59-73) in the R-CHOP group (hazard ratio [HR] 0·56, 95% CI 0·38-0·83; p=0·0035). 3-year estimates of progression-free survival (87% [95% CI, 81-91] vs 73% [66-79]; HR 0·48 [0·30-0·76]; p=0·0015) and overall survival (92% [87-95] vs 84% [77-89]; HR 0·44 [0·28-0·81]; p=0·0071) were also increased in the R-ACVBP group. 82 (42%) of 196 patients in the R-ACVBP group experienced a serious adverse event compared with 28 (15%) of 183 in the R-CHOP group. Grade 3-4 haematological toxic effects were more common in the R-ACVBP group, with a higher proportion of patients experiencing a febrile neutropenic episode (38% [75 of 196] vs 9% [16 of 183]). INTERPRETATION: Compared with standard R-CHOP, intensified immunochemotherapy with R-ACVBP significantly improves survival of patients aged 18-59 years with diffuse large B-cell lymphoma with low-intermediate risk according to the International Prognostic Index. Haematological toxic effects of the intensive regimen were raised but manageable. FUNDING: Groupe d'Etudes des Lymphomes de l'Adulte and Amgen.
Resumo:
PURPOSE: Statistical shape and appearance models play an important role in reducing the segmentation processing time of a vertebra and in improving results for 3D model development. Here, we describe the different steps in generating a statistical shape model (SSM) of the second cervical vertebra (C2) and provide the shape model for general use by the scientific community. The main difficulties in its construction are the morphological complexity of the C2 and its variability in the population. METHODS: The input dataset is composed of manually segmented anonymized patient computerized tomography (CT) scans. The alignment of the different datasets is done with the procrustes alignment on surface models, and then, the registration is cast as a model-fitting problem using a Gaussian process. A principal component analysis (PCA)-based model is generated which includes the variability of the C2. RESULTS: The SSM was generated using 92 CT scans. The resulting SSM was evaluated for specificity, compactness and generalization ability. The SSM of the C2 is freely available to the scientific community in Slicer (an open source software for image analysis and scientific visualization) with a module created to visualize the SSM using Statismo, a framework for statistical shape modeling. CONCLUSION: The SSM of the vertebra allows the shape variability of the C2 to be represented. Moreover, the SSM will enable semi-automatic segmentation and 3D model generation of the vertebra, which would greatly benefit surgery planning.
Resumo:
Fetal MRI reconstruction aims at finding a high-resolution image given a small set of low-resolution images. It is usually modeled as an inverse problem where the regularization term plays a central role in the reconstruction quality. Literature has considered several regularization terms s.a. Dirichlet/Laplacian energy [1], Total Variation (TV)based energies [2,3] and more recently non-local means [4]. Although TV energies are quite attractive because of their ability in edge preservation, standard explicit steepest gradient techniques have been applied to optimize fetal-based TV energies. The main contribution of this work lies in the introduction of a well-posed TV algorithm from the point of view of convex optimization. Specifically, our proposed TV optimization algorithm for fetal reconstruction is optimal w.r.t. the asymptotic and iterative convergence speeds O(1/n(2)) and O(1/root epsilon), while existing techniques are in O(1/n) and O(1/epsilon). We apply our algorithm to (1) clinical newborn data, considered as ground truth, and (2) clinical fetal acquisitions. Our algorithm compares favorably with the literature in terms of speed and accuracy.
Resumo:
PURPOSE: To evaluate the feasibility of visualizing the stent lumen using coronary magnetic resonance angiography in vitro. MATERIAL AND METHODS: Nineteen different coronary stents were implanted in plastic tubes with an inner diameter of 3 mm. The tubes were positioned in a plastic container filled with gel and included in a closed flow circuit (constant flow 18 cm/sec). The magnetic resonance images were obtained with a dual inversion fast spin-echo sequence. For intraluminal stent imaging, subtraction images were calculated from scans with and without flow. Subsequently, intraluminal signal properties were objectively assessed and compared. RESULTS: As a function of the stent type, various degrees of in-stent signal attenuation were observed. Tantalum stents demonstrated minimal intraluminal signal attenuation. For nitinol stents, the stent lumen could be identified, but the intraluminal signal was markedly reduced. Steel stents resulted in the most pronounced intraluminal signal voids. CONCLUSIONS: With the present technique, radiofrequency penetration into the stents is strongly influenced by the stent material. Thesefindings may have important implicationsforfuture stent design and stent imaging strategies.
Resumo:
Functional connectivity in human brain can be represented as a network using electroencephalography (EEG) signals. These networks--whose nodes can vary from tens to hundreds--are characterized by neurobiologically meaningful graph theory metrics. This study investigates the degree to which various graph metrics depend upon the network size. To this end, EEGs from 32 normal subjects were recorded and functional networks of three different sizes were extracted. A state-space based method was used to calculate cross-correlation matrices between different brain regions. These correlation matrices were used to construct binary adjacency connectomes, which were assessed with regards to a number of graph metrics such as clustering coefficient, modularity, efficiency, economic efficiency, and assortativity. We showed that the estimates of these metrics significantly differ depending on the network size. Larger networks had higher efficiency, higher assortativity and lower modularity compared to those with smaller size and the same density. These findings indicate that the network size should be considered in any comparison of networks across studies.
Resumo:
Red blood cell (RBC) parameters such as morphology, volume, refractive index, and hemoglobin content are of great importance for diagnostic purposes. Existing approaches require complicated calibration procedures and robust cell perturbation. As a result, reference values for normal RBC differ depending on the method used. We present a way for measuring parameters of intact individual RBCs by using digital holographic microscopy (DHM), a new interferometric and label-free technique with nanometric axial sensitivity. The results are compared with values achieved by conventional techniques for RBC of the same donor and previously published figures. A DHM equipped with a laser diode (lambda = 663 nm) was used to record holograms in an off-axis geometry. Measurements of both RBC refractive indices and volumes were achieved via monitoring the quantitative phase map of RBC by means of a sequential perfusion of two isotonic solutions with different refractive indices obtained by the use of Nycodenz (decoupling procedure). Volume of RBCs labeled by membrane dye Dil was analyzed by confocal microscopy. The mean cell volume (MCV), red blood cell distribution width (RDW), and mean cell hemoglobin concentration (MCHC) were also measured with an impedance volume analyzer. DHM yielded RBC refractive index n = 1.418 +/- 0.012, volume 83 +/- 14 fl, MCH = 29.9 pg, and MCHC 362 +/- 40 g/l. Erythrocyte MCV, MCH, and MCHC achieved by an impedance volume analyzer were 82 fl, 28.6 pg, and 349 g/l, respectively. Confocal microscopy yielded 91 +/- 17 fl for RBC volume. In conclusion, DHM in combination with a decoupling procedure allows measuring noninvasively volume, refractive index, and hemoglobin content of single-living RBCs with a high accuracy.
Resumo:
Ultrasound segmentation is a challenging problem due to the inherent speckle and some artifacts like shadows, attenuation and signal dropout. Existing methods need to include strong priors like shape priors or analytical intensity models to succeed in the segmentation. However, such priors tend to limit these methods to a specific target or imaging settings, and they are not always applicable to pathological cases. This work introduces a semi-supervised segmentation framework for ultrasound imaging that alleviates the limitation of fully automatic segmentation, that is, it is applicable to any kind of target and imaging settings. Our methodology uses a graph of image patches to represent the ultrasound image and user-assisted initialization with labels, which acts as soft priors. The segmentation problem is formulated as a continuous minimum cut problem and solved with an efficient optimization algorithm. We validate our segmentation framework on clinical ultrasound imaging (prostate, fetus, and tumors of the liver and eye). We obtain high similarity agreement with the ground truth provided by medical expert delineations in all applications (94% DICE values in average) and the proposed algorithm performs favorably with the literature.
Resumo:
To make a comprehensive evaluation of organ-specific out-of-field doses using Monte Carlo (MC) simulations for different breast cancer irradiation techniques and to compare results with a commercial treatment planning system (TPS). Three breast radiotherapy techniques using 6MV tangential photon beams were compared: (a) 2DRT (open rectangular fields), (b) 3DCRT (conformal wedged fields), and (c) hybrid IMRT (open conformal+modulated fields). Over 35 organs were contoured in a whole-body CT scan and organ-specific dose distributions were determined with MC and the TPS. Large differences in out-of-field doses were observed between MC and TPS calculations, even for organs close to the target volume such as the heart, the lungs and the contralateral breast (up to 70% difference). MC simulations showed that a large fraction of the out-of-field dose comes from the out-of-field head scatter fluence (>40%) which is not adequately modeled by the TPS. Based on MC simulations, the 3DCRT technique using external wedges yielded significantly higher doses (up to a factor 4-5 in the pelvis) than the 2DRT and the hybrid IMRT techniques which yielded similar out-of-field doses. In sharp contrast to popular belief, the IMRT technique investigated here does not increase the out-of-field dose compared to conventional techniques and may offer the most optimal plan. The 3DCRT technique with external wedges yields the largest out-of-field doses. For accurate out-of-field dose assessment, a commercial TPS should not be used, even for organs near the target volume (contralateral breast, lungs, heart).
Resumo:
To analyze the neural basis of electric taste we performed electrical neuroimaging analyses of event-related potentials (ERPs) recorded while participants received electrical pulses to the tongue. Pulses were presented at individual taste threshold to excite gustatory fibers selectively without concomitant excitation of trigeminal fibers and at high intensity evoking a prickling and, thus, activating trigeminal fibers. Sour, salty and metallic tastes were reported at both intensities while clear prickling was reported at high intensity only. ERPs exhibited augmented amplitudes and shorter latencies for high intensity. First activations of gustatory areas (bilateral anterior insula, medial orbitofrontal cortex) were observed at 70-80ms. Common somatosensory regions were more strongly, but not exclusively, activated at high intensity. Our data provide a comprehensive view on the dynamics of cortical processing of the gustatory and trigeminal portions of electric taste and suggest that gustatory and trigeminal afferents project to overlapping cortical areas.
Resumo:
Recent advances in CT technologies had significantly improved the clinical utility of cardiac CT. Major efforts have been made to optimize the image quality, standardize protocols and limit the radiation exposure. Rapid progress in post-processing tools dedicated not only to the coronary artery assessment but also to the cardiac cavities, valves and veins extended applications of cardiac CT. This potential might be however used optimally considering the current appropriate indications for use as well as the current technical imitations. Coronary artery disease and related ischemic cardiomyopathy remain the major applications of cardiac CT and at the same time the most complex one. Integration of a specific knowledge is mandatory for optimal use in this area for asymptomatic as for symptomatic patients, with a specific regards to patient with acute chest pain. This review aimed to propose a practical approach to implement appropriate indications in our routine practice. Emerging indications and future direction are also discussed. Adequate preparation of the patient, training of physicians, and the multidisciplinary interaction between actors are the key of successful implementation of cardiac CT in daily practice.
Resumo:
Introduction: Consultations with patients suffering from chronic pain without objective findings represent a challenge fo r family doctors (FDs). A mutual lack of understanding may arise, which threatens the doctor-patient relationship and may lead to dissatisfaction of both patient and doctor and to a breakdown of the therapeutic alliance. Objectives: This study aims to investigate FDs' potential protective practices to preserve the doctor-patient relationship during this type of consultation. Method: In the first step of this qualitative research, I carried out a range of 10 se- mi-structured interviews with FDs to explore their reported practices and repre- sentations during consultations with people suffering from chronic pain without objective findings. The interviews' transcripts were integrally analysed with computer-assisted thematic content analysis (QSR NVivo ® ) to highlight the main themes related to the topic in the participants' talk. Results: At this point of the research, two types of FDs' protective practices can be identified: first the use of complementary sources of knowledge in addition to the medical model to provide explanations to patients, second the collaboration with multidisciplinary teams or support gr oups that allow them to share profes- sional expertise and emotional experiences. Conclusion: The findings could be useful to develop ways to improve the follow- up of patients suffering from chronic pain without objective findings and conse- quently the FDs' work satisfaction.
Resumo:
The aim of this study was to propose a methodology allowing a detailed characterization of body sit-to-stand/stand-to-sit postural transition. Parameters characterizing the kinematics of the trunk movement during sit-to-stand (Si-St) postural transition were calculated using one initial sensor system fixed on the trunk and a data logger. Dynamic complexity of these postural transitions was estimated by fractal dimension of acceleration-angular velocity plot. We concluded that this method provides a simple and accurate tool for monitoring frail elderly and to objectively evaluate the efficacy of a rehabilitation program.
Resumo:
Given the significant impact the use of glucocorticoids can have on fracture risk independent of bone density, their use has been incorporated as one of the clinical risk factors for calculating the 10-year fracture risk in the World Health Organization's Fracture Risk Assessment Tool (FRAX(®)). Like the other clinical risk factors, the use of glucocorticoids is included as a dichotomous variable with use of steroids defined as past or present exposure of 3 months or more of use of a daily dose of 5 mg or more of prednisolone or equivalent. The purpose of this report is to give clinicians guidance on adjustments which should be made to the 10-year risk based on the dose, duration of use and mode of delivery of glucocorticoids preparations. A subcommittee of the International Society for Clinical Densitometry and International Osteoporosis Foundation joint Position Development Conference presented its findings to an expert panel and the following recommendations were selected. 1) There is a dose relationship between glucocorticoid use of greater than 3 months and fracture risk. The average dose exposure captured within FRAX(®) is likely to be a prednisone dose of 2.5-7.5 mg/day or its equivalent. Fracture probability is under-estimated when prednisone dose is greater than 7.5 mg/day and is over-estimated when the prednisone dose is less than 2.5 mg/day. 2) Frequent intermittent use of higher doses of glucocorticoids increases fracture risk. Because of the variability in dose and dosing schedule, quantification of this risk is not possible. 3) High dose inhaled glucocorticoids may be a risk factor for fracture. FRAX(®) may underestimate fracture probability in users of high dose inhaled glucocorticoids. 4) Appropriate glucocorticoid replacement in individuals with adrenal insufficiency has not been found to increase fracture risk. In such patients, use of glucocorticoids should not be included in FRAX(®) calculations.
Resumo:
With increasing costs for conducting surveys, many survey agencies resort to implementing call strategies. Obtaining contact in panel surveys as early as possible, without annoying people by contacting them at undesired times and ultimately causing them to refuse, requires using efficient call time strategies. In this research, the author uses call data from the Swiss Household Panel (SHP), a centralized Computer Assisted Telephone Interview (CATI) survey with a randomized (experimental) call-household assignment. Using random effects models, the author analyzes the efficiency gains of obtaining initial contact by assigning optimal times to first calls, and times and spacing to second and later calls depending on household sociodemography and prior call patterns. The author concludes with some recommendations for making early and successful contact during fieldwork.