248 resultados para Nursing. Blood Pressure Determination. Validation Studies. Knowledge. Questionnaires
Resumo:
Short-term exposure to ambient particulate matter with aerodynamic diameters<10 µm were found to be positively associated with blood pressure. Yet, little information exists regarding the association between particles and circadian rhythm of blood pressure. Hence, we analyzed the association of exposure to particulate matter with aerodynamic diameters<10 µm on the day of examination and ≤7 days before with ambulatory blood pressure and with sodium excretion in 359 adults from the general population using multiple linear regression. After controlling for potential confounders, a 10-µg/m3 increase in particulate matter with aerodynamic diameters<10 µm levels was associated with nighttime systolic blood pressure (β=1.32 mm Hg 95% CI, 0.06-2.58 mm Hg at lag 0; P=0.04), nighttime diastolic blood pressure (0.72 mm Hg 95% CI, 0.03-1.42 mm Hg at lag 2; P=0.04), nocturnal systolic blood pressure dipping (-0.96 mm Hg 95% CI, -1.89 to -0.03 mm Hg at lag 0; P=0.044), and daytime urinary sodium excretion (-0.05 log-mmol/min 95% CI, -0.10 to -0.01 log-mmol/min at lag 0; P=0.027) but not with nighttime sodium excretion. The associations with blood pressure rapidly diminished with increasing lag days, and the associations with daytime sodium excretion were maximal with particulate matter with aerodynamic diameters<10 µm in exposures 2 to 5 days before. The associations of short-term increases in particulate matter with aerodynamic diameters<10 µm with higher nighttime blood pressure and blunted systolic blood pressure dipping were preceded by associations with reduced ability of the kidney to excrete sodium during daytime. The underlying mechanism linking air pollution to increased cardiovascular risk may include disturbed circadian rhythms of renal sodium handling and blood pressure.
Resumo:
The antihypertensive effects of the beta-blocking agent betaxolol and the calcium entry blocker verapamil were compared in a crossover single-blind trial. Seventeen patients with uncomplicated essential hypertension took either betaxolol or a slow-release formulation of verapamil for two consecutive 6-week periods. The sequence of treatment phases was randomly allocated and a 2-week washout period preceded each treatment. The antihypertensive effect of the test drugs was assessed both at the physician's office and during everyday activities using a portable blood pressure recorder. The crossover design of the trial made it possible to evaluate the antihypertensive efficacy of betaxolol and verapamil both in the group as a whole and in the individual patient. The individual patient response to one of these agents was not a reliable indicator of the same patient's response to the alternative agent. Betaxolol brought both office and ambulatory recorded blood pressures under control in a larger fraction of patients than verapamil, although the magnitude of the blood pressure fall in the responders was equal for each drug. These observations stress the need for an individualized approach to the evaluation of antihypertensive therapy. The present results also demonstrate that optimal antihypertensive therapy is still a matter of trial and error. The precise methodology that ought to characterize crossover trials may make it possible to improve the therapeutic approach to hypertensive patients.
Resumo:
OBJECTIVE: Body composition measured by dual-energy X-ray absorptiometry (DXA) is believed to be superior to crude measures such as BMI or waist circumference (WC) to assess health risks associated with adiposity in adults. We compared the ability of BMI, WC, waist-to-height ratio (WHtR), percentage body fat from skinfold thickness, and measures of total and central fat assessed by DXA to identify children with elevated blood pressure (BP). STUDY DESIGN: The QUALITY Study follows 630 Caucasian families (father, mother, and child originally aged 8-10 years). BP, height, weight, WC, and skinfold thickness were measured according to standardized protocols. Elevated BP was defined as systolic or diastolic BP at least 90th age, sex, and height-specific percentile. Total and central fat were determined with DXA. The area under the receiver operating characteristic (ROC) curve (AUC) statistic was computed from logistic models that adjusted for age, sex, height, Tanner stage, and physical activity. RESULTS: All adiposity indicators were highly correlated. WC and WHtR did not show superior ability over BMI to identify children with elevated SBP (P = 0.421 and 0.473). Measures of total and central fat from DXA did not show an improved ability over BMI or WC to identify children with elevated SBP (P = 0.325-0.662). CONCLUSION: Results support the use of BMI in clinical and public health settings, at least in this age group. As all indicators had a limited ability to identify children with elevated BP, results also support measurement of BP in all children of this age independent of a weight status.
Resumo:
Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.
Resumo:
In 2010, hypertension in Sub-Saharan Africa was theleading risk for death, incr easing by 67% since 1990.Hypertension was estimated to cause more than500,000 deaths and 10 million years of life lost in2010 in Sub-Saharan Africa. It was also the sixthleading risk for disability (contributing to more than 11million disability-adjusted life years).3In Sub-Saharan Africa, stroke, the major clinical outcome of uncon-trolled hypertension, has increased 46% since 1990 tobecome the fifth leading risk for death.