284 resultados para Intra-operator variability


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: In a simulation based on a pharmacokinetic model we demonstrated that increasing the erythropoiesis stimulating agents (ESAs) half-life or shortening their administration interval decreases hemoglobin variability. The benefit of reducing the administration interval was however lessened by the variability induced by more frequent dosage adjustments. The purpose of this study was to analyze the reticulocyte and hemoglobin kinetics and variability under different ESAs and administration intervals in a collective of chronic hemodialysis patients. METHODS: The study was designed as an open-label, randomized, four-period cross-over investigation, including 30 patients under chronic hemodialysis at the regional hospital of Locarno (Switzerland) in February 2010 and lasting 2 years. Four subcutaneous treatment strategies (C.E.R.A. every 4 weeks Q4W and every 2 weeks Q2W, Darbepoetin alfa Q4W and Q2W) were compared with each other. The mean square successive difference of hemoglobin, reticulocyte count and ESAs dose was used to quantify variability. We distinguished a short- and a long-term variability based respectively on the weekly and monthly successive difference. RESULTS: No difference was found in the mean values of biological parameters (hemoglobin, reticulocytes, and ferritin) between the 4 strategies. ESAs type did not affect hemoglobin and reticulocyte variability, but C.E.R.A induced a more sustained reticulocytes response over time and increased the risk of hemoglobin overshooting (OR 2.7, p = 0.01). Shortening the administration interval lessened the amplitude of reticulocyte count fluctuations but resulted in more frequent ESAs dose adjustments and in amplified reticulocyte and hemoglobin variability. Q2W administration interval was however more favorable in terms of ESAs dose, allowing a 38% C.E.R.A. dose reduction, and no increase of Darbepoetin alfa. CONCLUSIONS: The reticulocyte dynamic was a more sensitive marker of time instability of the hemoglobin response under ESAs therapy. The ESAs administration interval had a greater impact on hemoglobin variability than the ESAs type. The more protracted reticulocyte response induced by C.E.R.A. could explain both, the observed higher risk of overshoot and the significant increase in efficacy when shortening its administration interval.Trial registrationClinicalTrials.gov NCT01666301.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Meropenem, a carbapenem antibiotic displaying a broad spectrum of antibacterial activity, is administered in Medical Intensive Care Unit to critically ill patients undergoing continuous veno-venous haemodiafiltration (CVVHDF). However, there are limited data available to substantial rational dosing decisions in this condition. In an attempt to refine our knowledge and propose a rationally designed dosage regimen, we have developed a HPLC method to determine meropenem after solid-phase extraction (SPE) of plasma and dialysate fluids obtained from patients under CVVHDF. The assay comprises the simultaneous measurement of meropenem's open-ring metabolite UK-1a, whose fate has never been studied in CVVHDF patients. The clean-up procedure involved a SPE on C18 cartridge. Matrix components were eliminated with phosphate buffer pH 7.4 followed by 15:85 MeOH-phosphate buffer pH 7.4. Meropenem and UK-1a were subsequently desorbed with MeOH. The eluates were evaporated under nitrogen at room temperature (RT) and reconstituted in phosphate buffer pH 7.4. Separation was performed at RT on a Nucleosil 100-5 microm C18 AB cartridge column (125 x 4 mm I.D.) equipped with a guard column (8 x 4 mm I.D.) with UV-DAD detection set at 208 nm. The mobile phase was 1 ml min(-1), using a step-wise gradient elution program: %MeOH/0.005 M tetrabutylammonium chloride pH 7.4; 10/90-50/50 in 27 min. Over the range of 5-100 microg ml(-1), the regression coefficient of the calibration curves (plasma and dialysate) were >0.998. The absolute extraction recoveries of meropenem and UK-1a in plasma and filtrate-dialysate were stable and ranged from 88-93 to 72-77% for meropenem, and from 95-104 to 75-82% for UK-1a. In plasma and filtrate-dialysate, respectively, the mean intra-assay precision was 4.1 and 2.6% for meropenem and 4.2 and 3.7% for UK-1a. The inter-assay variability was 2.8 and 3.6% for meropenem and 2.3 and 2.8% for UK-1a. The accuracy was satisfactory for both meropenem and UK-1a with deviation never exceeding 9.0% of the nominal concentrations. The stability of meropenem, studied in biological samples left at RT and at +4 degrees C, was satisfactory with < 5% degradation after 1.5 h in blood but reached 22% in filtrate-dialysate samples stored at RT for 8 h, precluding accurate measurements of meropenem excreted unchanged in the filtrate-dialysate left at RT during the CVVHDF procedure. The method reported here enables accurate measurements of meropenem in critically ill patients under CVVHDF, making dosage individualisation possible in such patients. The levels of the metabolite UK-1a encountered in this population of patients were higher than those observed in healthy volunteers but was similar to those observed in patients with renal impairment under hemodialysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The biodistribution of simultaneous intra-arterial and intravenous injections of a radiolabelled anti-CEA MAb F(ab')2 fragment was studied in three patients with liver metastases from colorectal cancer. Identical MAb fragments, labelled with either 125I or 131I, were injected over a period of 30 min into the hepatic artery and into a peripheral vein. After 1 or 2 days, biodistribution was measured in the surgically removed metastases, normal tissue samples and blood. By tissue radioactivity counting, tumour uptake in the range 6.3-9.1% of injected dose per gram was found. Superimposable metastasis-to-blood and metastasis-to-normal liver ratios were obtained for both iodine isotopes in all three patients. The results indicate that the intra-arterial injection of MAb F(ab')2 fragments gives no measurable advantage over more convenient injections into a peripheral vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is evidence across several species for genetic control of phenotypic variation of complex traits, such that the variance among phenotypes is genotype dependent. Understanding genetic control of variability is important in evolutionary biology, agricultural selection programmes and human medicine, yet for complex traits, no individual genetic variants associated with variance, as opposed to the mean, have been identified. Here we perform a meta-analysis of genome-wide association studies of phenotypic variation using ∼170,000 samples on height and body mass index (BMI) in human populations. We report evidence that the single nucleotide polymorphism (SNP) rs7202116 at the FTO gene locus, which is known to be associated with obesity (as measured by mean BMI for each rs7202116 genotype), is also associated with phenotypic variability. We show that the results are not due to scale effects or other artefacts, and find no other experiment-wise significant evidence for effects on variability, either at loci other than FTO for BMI or at any locus for height. The difference in variance for BMI among individuals with opposite homozygous genotypes at the FTO locus is approximately 7%, corresponding to a difference of ∼0.5 kilograms in the standard deviation of weight. Our results indicate that genetic variants can be discovered that are associated with variability, and that between-person variability in obesity can partly be explained by the genotype at the FTO locus. The results are consistent with reported FTO by environment interactions for BMI, possibly mediated by DNA methylation. Our BMI results for other SNPs and our height results for all SNPs suggest that most genetic variants, including those that influence mean height or mean BMI, are not associated with phenotypic variance, or that their effects on variability are too small to detect even with samples sizes greater than 100,000.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We investigated possible relations among four common neonatal manifestations of diabetic pregnancy (macrosomia, hypoglycemia, hypocalcemia, jaundice) and four enzyme polymorphisms (PGM1, ADA, AK1, ACP1 in a sample of infants born of diabetic mothers. The pattern of associations observed between the two sets of variables is consistent with known differences in enzymatic activity within phenotypes of each system, suggesting that low enzymatic activity may have unfavorable effects on fetal development and on adaptability of the neonate to the extrauterine environment, Some of the polymorphic enzymes studied influence fetal growth in normal pregnancy as well. Analysis of relations between genetic polymorphisms and the clinical pattern of common diseases may provide a better understanding of the genetic basis of the clinical variability of diseases within and between human populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Thirty to forty percent of patients with recurrent gastrointestinal perforation/anastomotic leakage or acute necrotizing pancreatitis develop intra-abdominal invasive candidiasis (IC). A corrected Candida colonization index (CCI) > or =0.4 is a powerful predictor of IC. Fluconazole prevents intra-abdominal IC in this setting, but azole-resistant Candida species are emerging. The aim of this study was to explore the efficacy and safety of caspofungin for prevention of intra-abdominal IC in high-risk surgical patients. METHODS: Prospective non-comparative single-center study in consecutive adult surgical patients with recurrent gastrointestinal perforation/anastomotic leakage or acute necrotizing pancreatitis. Preventive caspofungin therapy (70 mg, then 50 mg/day) was given until resolution of the surgical condition. Candida colonization index and CCI, occurrence of intra-abdominal IC and adverse events were monitored. RESULTS: Nineteen patients were studied: 16 (84%) had recurrent gastrointestinal perforation/anastomotic leakage and 3 (16%) acute necrotizing pancreatitis. The median duration of preventive caspofungin therapy was 16 days (range 4-46). The colonization index decreased significantly during study therapy, and the CCI remained <0.4 in all patients. Caspofungin was successful for prevention of intra-abdominal IC in 18/19 patients (95%, 1 breakthrough IC 5 days after inclusion). No drug-related adverse event requiring caspofungin discontinuation occurred. CONCLUSION: Caspofungin may be efficacious and safe for prevention of intra-abdominal candidiasis in high-risk surgical patients. This needs to be further investigated in randomized trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Paleoclimatic reconstructions coupled with species distribution models and identification of extant spatial genetic structure have the potential to provide insights into the demographic events that shape the distribution of intra-specific genetic variation across time. Using the globeflower Trollius europaeus as a case-study, we combined (1) Amplified Fragment Length Polymorphisms, (2) suites of 1000-years stepwise hindcasted species distributions and (3) a model of diffusion through time over the last 24,000 years, to trace the spatial dynamics that most likely fits the species' current genetic structure. We show that the globeflower comprises four gene pools in Europe which, from the dry period preceding the Last Glacial Maximum, dispersed while tracking the conditions fitting its climatic niche. Among these four gene pools, two are predicted to experience drastic range retraction in the near future. Our interdisciplinary approach, applicable to virtually any taxon, is an advance in inferring how climate change impacts species' genetic structures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate inter- and intraobserver variability of indices crucial for detection of keratoconus progression derived from the Pentacam HR® (high-resolution) tomographer (OCULUS Optikgeräte GmbH, Wetzlar, Germany) in patients with mild to moderate keratoconus. Methods: Three repeated corneal topography measurements in the 25-picture mode by two independent observers were performed. The extent of variability across a large range of measurement parameters was analyzed including anterior and posterior corneal surface measurements, pachymetry values, corneal volume, anterior chamber volume and depth, and iridocorneal angle. The intraclass correlation coefficient (ICC) between and within each investigator was calculated to assess reproducibility and repeatability, respectively. Results: 31 eyes of 20 patients (mean age 31.6, SD ± 8.6) were included. Overall, the repeatability and reproducibility were excellent. The range of variability was reported by calculating the standard deviation of measurements. The detailed results are shown in Table 1. Conclusions: This study shows that the Pentacam HR® tomographer provides reliable measurements in patients with mild to moderate keratoconus. However, all parameters showed a certain range of variability. This should be taken into account when assessing keratoconus progression in order to distinguish true progression from variability in measurements. In addition, the excellent reproducibility suggests that the measurements can be reliably performed by different individuals from one visit to another.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The multiscale finite-volume (MSFV) method has been derived to efficiently solve large problems with spatially varying coefficients. The fine-scale problem is subdivided into local problems that can be solved separately and are coupled by a global problem. This algorithm, in consequence, shares some characteristics with two-level domain decomposition (DD) methods. However, the MSFV algorithm is different in that it incorporates a flux reconstruction step, which delivers a fine-scale mass conservative flux field without the need for iterating. This is achieved by the use of two overlapping coarse grids. The recently introduced correction function allows for a consistent handling of source terms, which makes the MSFV method a flexible algorithm that is applicable to a wide spectrum of problems. It is demonstrated that the MSFV operator, used to compute an approximate pressure solution, can be equivalently constructed by writing the Schur complement with a tangential approximation of a single-cell overlapping grid and incorporation of appropriate coarse-scale mass-balance equations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To remind of the absolute necessity for early diagnosis in the presence of ocular signs in children giving rise to possible intraocular tumours. METHOD: Based on our own experience of intraocular tumours in children, together with findings from the literature, diagnostic criteria and methods of treatment are presented. RESULTS: Retinoblastoma is the predominant cause of intraocular tumours in children, representing over 80% of cases under the age of 15 years. Other diseases may give rise to the same initial signs, usually leukocoria, sometimes strabismus, more rarely other atypical signs. Elements taken into account for diagnosis include age, sex, laterality, heredity, size of the globe, clinical aspect of the tumours, presence of calcifications and vitreous seeding. Full fundus examination under general anaesthetic is usually necessary. Biological examination, ultrasonography, computerized tomography and MRI enable an accurate diagnosis to be made in the majority of doubtful cases. The management of retinoblastoma is adapted for each individual case from the wide range of treatments available. Enucleation, radioactive applicators (...), brachytherapy (...), cryo- and photocoagulation represent classical measures. Primary chemotherapy, combined with other treatments such as thermotherapy, has become the treatment of choice in those cases where external beam radiotherapy has been used up to now, or in some instances before enucleation. Enucleation is usually carried out for medullo-epitheliomas, but brachytherapy may offer an alternative. CONCLUSION: Any unexplained ocular sign in children should be considered as a possible retinoblastoma, making an accurate and certain diagnosis imperative. Early treatment may save not only the life but also the vision of patients carrying this highly malignant lesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

U-Pb dating of zircons by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is a widely used analytical technique in Earth Sciences. For U-Pb ages below 1 billion years (1 Ga), Pb-206/U-238 dates are usually used, showing the least bias by external parameters such as the presence of initial lead and its isotopic composition in the analysed mineral. Precision and accuracy of the Pb/U ratio are thus of highest importance in LA-ICPMS geochronology. We consider the evaluation of the statistical distribution of the sweep intensities based on goodness-of-fit tests in order to find a model probability distribution fitting the data to apply an appropriate formulation for the standard deviation. We then discuss three main methods to calculate the Pb/U intensity ratio and its uncertainty in the LA-ICPMS: (1) ratio-of-the-mean intensities method, (2) mean-of-the-intensity-ratios method and (3) intercept method. These methods apply different functions to the same raw intensity vs. time data to calculate the mean Pb/U intensity ratio. Thus, the calculated intensity ratio and its uncertainty depend on the method applied. We demonstrate that the accuracy and, conditionally, the precision of the ratio-of-the-mean intensities method are invariant to the intensity fluctuations and averaging related to the dwell time selection and off-line data transformation (averaging of several sweeps); we present a statistical approach how to calculate the uncertainty of this method for transient signals. We also show that the accuracy of methods (2) and (3) is influenced by the intensity fluctuations and averaging, and the extent of this influence can amount to tens of percentage points; we show that the uncertainty of these methods also depends on how the signal is averaged. Each of the above methods imposes requirements to the instrumentation. The ratio-of-the-mean intensities method is sufficiently accurate provided the laser induced fractionation between the beginning and the end of the signal is kept low and linear. We show, based on a comprehensive series of analyses with different ablation pit sizes, energy densities and repetition rates for a 193 nm ns-ablation system that such a fractionation behaviour requires using a low ablation speed (low energy density and low repetition rate). Overall, we conclude that the ratio-of-the-mean intensities method combined with low sampling rates is the most mathematically accurate among the existing data treatment methods for U-Pb zircon dating by sensitive sector field ICPMS.