199 resultados para Environemental gradient
Resumo:
Carcinoembryonic antigen (CEA) was identified in perchloric acid (PCA)_extract from normal colon mucosa by 2 immunological criteria: a line of identity in double diffusion and a parallel inhibition curve in radioimmunoassay (RIA), both with reference colon carcinoma-CEA (CEA-Tu). The average concentration of CEA in normal colon mucosa (CEA-No) was 35 times lower than in primary large bowel carcinomas and 230 times lower than in metastatic colon or rectum carcinomas. CEA-No was purified from PCA extracts of normal colon mucosa by Sephadex G-200 filtration and immunoadsorbent columns. Purified CEA-No had quatitatively the same inhibition activity in RIA as the British Standard CEA coded 73/601. Purified CEA-No was labelled with 125I. The percentage of binding of labelled CEA-No to a specific goat anti-CEA-Tu antiserum was similar to that of CEA-Tu. Labelled CEA-No could be used as radioactive tracer in RIA as well as labelled CEA-Tu. The physico-chemical properties of purified CEA-Tu as demonstrated by Sepharose 6 B filtration, SDS Polyacrylamide gel analysis and cesium chloride density gradient, were found to be almost identical to those of reference CEA-Tu. Preliminary results showed that CEA-No and CEA-Tu contained the same types of carbohydrates in similar proportions. A rabbit antiserum against CEA-No was obtained which demonstrated the same specificity as conventional anti-CEA-Tu antisera.
Resumo:
OBJECTIVES Little is known about the stent deformability required for optimal stented heart valve bioprosthesis design. Therefore, two bioprosthetic valves with known good long-term clinical results were tested. The strain in the radial direction of the stent posts of these valves was compared with contemporary bioprosthetic valves and a native porcine aortic root. METHODS Medtronic Intact and Carpentier-Edwards Standard (CES), and four contemporary bioprostheses, including one self-expanding prosthesis, were tested with three sonomicrometry probes per valve fixed at commissure attachment points. The mean values from 2400 data points from three measurements of the interprobe distances were used to calculate the radius of the circle circumscribed around the three probes. Changes in the radius of the aortic root at pressures 70-90 and 120-140 mmHg (pressure during diastole and systole) and that of the stent posts at 70-90 and 0-10 mmHg (transvalvular pressure gradient during diastole and systole) were compared. RESULTS An increase in radius by 7.3 ± 2.6, 8.7 ± 0.0 and 3.9 ± 0.0% for the porcine aortic root, CES and Intact valves, respectively, was observed during transition from diastolic to systolic pressure and less for contemporary bioprostheses-mean 2.5 ± 0.9%, lowest 1.2 ± 0.0. CONCLUSIONS The results indicate that the radial deformability of bioprosthetic valve stent posts can be as low as 1.2% for xenoaortic and 3.0% for xenopericardial prostheses with no compromise of valve durability. Although these results suggest that valve stent post-deformability might not be of critical importance, a concrete answer to the question of the significance of stent deformability for valve durability can be obtained only by acquiring long-term follow-up results for valve prostheses with rigid stents.
Resumo:
The purpose of this study was to evaluate a free-breathing three-dimensional (3D) dual inversion-recovery (DIR) segmented k-space gradient-echo (turbo field echo [TFE]) imaging sequence at 3T for the quantification of aortic vessel wall dimensions. The effect of respiratory motion suppression on image quality was tested. Furthermore, the reproducibility of the aortic vessel wall measurements was investigated. Seven healthy subjects underwent 3D DIR TFE imaging of the aortic vessel wall with and without respiratory navigator. Subsequently, this sequence with respiratory navigator was performed twice in 10 healthy subjects to test its reproducibility. The signal-to-noise (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and vessel wall volume (VWV) were assessed. Data were compared using the paired t-test, and the reproducibility of VWV measurements was evaluated using intraclass correlation coefficients (ICCs). SNR, CNR, and vessel wall sharpness were superior in scans performed with respiratory navigator compared to scans performed without. The ICCs concerning intraobserver, interobserver, and interscan reproducibility were excellent (0.99, 0.94, and 0.95, respectively). In conclusion, respiratory motion suppression substantially improves image quality of 3D DIR TFE imaging of the aortic vessel wall at 3T. Furthermore, this optimized technique with respiratory motion suppression enables assessment of aortic vessel wall dimensions with high reproducibility.
Resumo:
How do cells sense their own size and shape? And how does this information regulate progression of the cell cycle? Our group, in parallel to that of Paul Nurse, have recently demonstrated that fission yeast cells use a novel geometry-sensing mechanism to couple cell length perception with entry into mitosis. These rod-shaped cells measure their own length by using a medially-placed sensor, Cdr2, that reads a protein gradient emanating from cell tips, Pom1, to control entry into mitosis. Budding yeast cells use a similar molecular sensor to delay entry into mitosis in response to defects in bud morphogenesis. Metazoan cells also modulate cell proliferation in response to their own shape by sensing tension. Here I discuss the recent results obtained for the fission yeast system and compare them to the strategies used by these other organisms to perceive their own morphology.