210 resultados para CT, Radiation Dose, Image Quality
Resumo:
A nation-wide survey on radiation doses in diagnostic and interventional radiology was conducted in Switzerland in 1998 aiming at establishing their collective radiological impact on the Swiss population. The study consisted on the one hand of surveying the frequency of more than 250 types of examinations, covering conventional radiology, mammography, fluoroscopy, angiography, interventional radiology, CT, bone densitometry, conventional tomography and dental radiology. On the other hand, for each type of examination the associated patient dose was established by modeling. The results of this study show that about 9.5 million diagnostic and interventional examinations are performed annually in Switzerland (1.34 per caput) and that the associated annual collective dose is of the order of 7100 person.Sv (1.0 mSv per caput). Switzerland is similar to other European countries in terms of the frequency of examinations and the collective dose.
Resumo:
Brain perfusion can be assessed by CT and MR. For CT, two major techniquesare used. First, Xenon CT is an equilibrium technique based on a freely diffusibletracer. First pass of iodinated contrast injected intravenously is a second method,more widely available. Both methods are proven to be robust and quantitative,thanks to the linear relationship between contrast concentration and x-ray attenuation.For the CT methods, concern regarding x-ray doses delivered to the patientsneed to be addressed. MR is also able to assess brain perfusion using the firstpass of gadolinium based contrast agent injected intravenously. This method hasto be considered as a semi-quantitative because of the non linear relationshipbetween contrast concentration and MR signal changes. Arterial spin labelingis another MR method assessing brain perfusion without injection of contrast. Insuch case, the blood flow in the carotids is magnetically labelled by an externalradiofrequency pulse and observed during its first pass through the brain. Eachof this various CT and MR techniques have advantages and limits that will be illustratedand summarised.Learning Objectives:1. To understand and compare the different techniques for brain perfusionimaging.2. To learn about the methods of acquisition and post-processing of brainperfusion by first pass of contrast agent for CT and MR.3. To learn about non contrast MR methods (arterial spin labelling).
Resumo:
The purpose of this study was to assess the spatial resolution of a computed tomography (CT) scanner with an automatic approach developed for routine quality controls when varying CT parameters. The methods available to assess the modulation transfer functions (MTF) with the automatic approach were Droege's and the bead point source (BPS) methods. These MTFs were compared with presampled ones obtained using Boone's method. The results show that Droege's method is not accurate in the low-frequency range, whereas the BPS method is highly sensitive to image noise. While both methods are well adapted to routine stability controls, it was shown that they are not able to provide absolute measurements. On the other hand, Boone's method, which is robust with respect to aliasing, more resilient to noise and provides absolute measurements, satisfies the commissioning requirements perfectly. Thus, Boone's method combined with a modified Catphan 600 phantom could be a good solution to assess CT spatial resolution in the different CT planes.
Resumo:
The comparison of radiotherapy techniques regarding secondary cancer risk has yielded contradictory results possibly stemming from the many different approaches used to estimate risk. The purpose of this study was to make a comprehensive evaluation of different available risk models applied to detailed whole-body dose distributions computed by Monte Carlo for various breast radiotherapy techniques including conventional open tangents, 3D conformal wedged tangents and hybrid intensity modulated radiation therapy (IMRT). First, organ-specific linear risk models developed by the International Commission on Radiological Protection (ICRP) and the Biological Effects of Ionizing Radiation (BEIR) VII committee were applied to mean doses for remote organs only and all solid organs. Then, different general non-linear risk models were applied to the whole body dose distribution. Finally, organ-specific non-linear risk models for the lung and breast were used to assess the secondary cancer risk for these two specific organs. A total of 32 different calculated absolute risks resulted in a broad range of values (between 0.1% and 48.5%) underlying the large uncertainties in absolute risk calculation. The ratio of risk between two techniques has often been proposed as a more robust assessment of risk than the absolute risk. We found that the ratio of risk between two techniques could also vary substantially considering the different approaches to risk estimation. Sometimes the ratio of risk between two techniques would range between values smaller and larger than one, which then translates into inconsistent results on the potential higher risk of one technique compared to another. We found however that the hybrid IMRT technique resulted in a systematic reduction of risk compared to the other techniques investigated even though the magnitude of this reduction varied substantially with the different approaches investigated. Based on the epidemiological data available, a reasonable approach to risk estimation would be to use organ-specific non-linear risk models applied to the dose distributions of organs within or near the treatment fields (lungs and contralateral breast in the case of breast radiotherapy) as the majority of radiation-induced secondary cancers are found in the beam-bordering regions.
Resumo:
Purpose: Diagnostic radiology involving ionizing radiation often leads to crucial information but also involves risk. Estimated cancer risks associated with CT range between 1 in 1000 to 1 in 10 000, depending on age and exposure settings. The aim of this contribution is to provide radiologists a way to inform a patient about these risks on a collective and individual base. Materials and methods: After a brief review of the effects of ionizing radiations, conversion from dose indicators into effective dose will be presented for radiography, fluoroscopy and CT. The Diagnostic Reference Level (DRL) concept will be then introduced to enable the reader to compare the level of exposure of various examinations. Finally, the limit of effective dose will be explained and risk projections after various radiological procedures for adults and children will be presented. Results: From an individual standpoint the benefit of a well justified and optimized CT examination clearly outweigh its risk of inducing a fatal cancer. The uncertainties associated with the effective dose concept should be kept in mind in order to avoid cancer risk projections after an examination on an individual basis. Conclusion: Risk factors or effective dose are not the simplest tools to communicate when dealing with radiological risks. Thus, a set of categories should be preferred as proposed in the ICRP (International Commission on Radiation Protection) report 99.
Resumo:
Diagnostic reference levels (DRLs) were established for 21 indication-based CT examinations for adults in Switzerland. One hundred and seventy-nine of 225 computed tomography (CT) scanners operated in hospitals and private radiology institutes were audited on-site and patient doses were collected. For each CT scanner, a correction factor was calculated expressing the deviation of the measured weighted computed tomography dose index (CTDI) to the nominal weighted CTDI as displayed on the workstation. Patient doses were corrected by this factor providing a realistic basis for establishing national DRLs. Results showed large variations in doses between different radiology departments in Switzerland, especially for examinations of the petrous bone, pelvis, lower limbs and heart. This indicates that the concept of DRLs has not yet been correctly applied for CT examinations in clinical routine. A close collaboration of all stakeholders is mandatory to assure an effective radiation protection of patients. On-site audits will be intensified to further establish the concept of DRLs in Switzerland.
Resumo:
INTRODUCTION: To report acute and late toxicities in patients with intermediate- and high-risk prostate cancer treated with combined high-dose-rate brachytherapy (HDR-B) and intensity-modulated radiation therapy (IMRT). MATERIALS AND METHODS: From March 2003 to September 2005, 64 men were treated with a single implant HDR-B with 21 Gy given in three fractions, followed by 50 Gy IMRT along with organ tracking. Median age was 66.1 years, and risk of recurrence was intermediate in 47% of the patients or high in 53% of the patients. Androgen deprivation therapy was received by 69% of the patients. Toxicity was scored according to the CTCAE version 3.0. Median follow-up was 3.1 years. RESULTS: Acute grade 3 genitourinary (GU) toxicity was observed in 7.8% of the patients, and late grades 3 and 4 GU toxicity was observed in 10.9% and 1.6% of the patients. Acute grade 3 gastrointestinal (GI) toxicity was experienced by 1.6% of the patients, and late grade 3 GI toxicity was absent. The urethral V(120) (urethral volume receiving > or =120% of the prescribed HDR-B dose) was associated with acute (P=.047) and late > or = grade 2 GU toxicities (P=.049). CONCLUSIONS: Late grades 3 and 4GU toxicity occurred in 10.9% and 1.6% of the patients after HDR-B followed by IMRT in association with the irradiated urethral volume. The impact of V(120) on GU toxicity should be validated in further studies.
Resumo:
Purpose/Objective(s): Letrozole radiosensitizes breast cancer cells in vitro. In clinical settings, no data exist for the combination of letrozole and radiotherapy. We assessed concurrent and sequential radiotherapy and letrozole in the adjuvant setting.Materials/Methods: The present study is registered with ClinicalTrials.gov, number NCT00208273. This Phase 2 randomized trial was undertaken in two centers in France and one in Switzerland between January 12, 2005, and February 21, 2007. One hundred fifty postmenopausal women with early-stage breast cancer were randomly assigned after conserving surgery to either concurrent radiotherapy and letrozole (n = 75) or sequential radiotherapy and letrozole (n = 75). Randomization was open label with a minimization technique, stratified by investigational centers, chemotherapy (yes vs. no), radiation boost (yes vs. no), and value of radiation-induced lymphocyte apoptosis (#16% vs. .16%). The whole breast was irradiated to a total dose of 50 Gy in 25 fractions over 5 weeks. In the case of supraclavicular and internal mammary node irradiation, the dose was 44 - 50 Gy. Letrozole was administered orally once daily at a dose of 2 - 5 mg for 5 years (beginning 3 weeks pre-radiotherapy in the concomitant group, and 3 weeks postradiotherapy in the sequential group). The primary endpoint was the occurrence of acute (during and within 6 weeks of radiotherapy) and late (within 2 years) radiation-induced Grade 2 or worse toxic effects of the skin and lung (functional pulmonary test and lung CT-scan). Analyses were by intention-to-treat. The long-term follow-up after 2 years was only performed in Montpellier (n = 121) and evaluated skin toxicity (clinical examination every 6 months), lung fibrosis (one CT-scan yearly), cosmetic outcome.Results: All patients were analyzed apart from 1 in the concurrent group who withdrew consent before any treatment.Within the first 2 years (n = 149), no lung toxicity was identified by CT scan and no modification from baseline was noted by the lung diffusion capacity test. Two patients in each group had Grade 2 or worse late effects (both radiation-induced subcutaneous fibrosis [RISF]). After 2 years (n = 121), and with a median follow-up of 50 months (38-62), 2 patients (1 in each arm) presented a Grade 3 RISF. No lung toxicity was identified by CT scan. Cosmetic results (photographies) and quality of life was good to excellent. All patients who had Grade 3 subcutaneous fibrosis had an RILA value of 16% or less, irrespective of the sequence with letrozole.Conclusions:With long-term follow-up, letrozole can be safely delivered shortly after surgery and concomitantly with radiotherapy.
Resumo:
The impact of curative radiotherapy depends mainly on the total dose delivered homogenously in the targeted volume. Nevertheless, the dose delivery is limited by the tolerated dose of the surrounding healthy tissues. Two different side effects (acute and late) can occur during and after radiotherapy. Of particular interest are the radiation-induced sequelae due to their irreversibility and the potential impact on daily quality of life. In a population treated in one center with the same technique, it appears that individual radiosensitivity clearly exists. In the hypothesis that genetic is involved in this area of research, lymphocytes seem to be the tissue of choice due to easy accessibility. Recently, low percentage of CD4 and CD8 lymphocyte apoptosis were shown to be correlated with high grade of sequelae. In addition, recent data suggest that patients with severe radiation-induced late side effects possess four or more SNP in candidate genes (ATM, SOD2, TGFB1, XRCC1 et XRCC3) and low radiation-induced CD8 lymphocyte apoptosis in vitro.
Resumo:
RATIONALE:We investigated the impact of canakinumab, a fully human anti-interleukin-1b monoclonal antibody on inflammation and HRQoL in gouty arthritis patients.METHODS: In this 8-week, single-blind, dose-ranging study, patients with acute gouty arthritis flares, unresponsive/intolerant or contraindicated to NSAIDs and/or colchicine were randomized to single subcutaneous canakinumab (10, 25, 50, 90, or 150mg, N5143) or single intramuscular triamcinolone acetonide (TA, 40mg, N557). Patients assessed pain (Likert scale), physicians assessed clinical signs of joint inflammation, and HRQoL was recorded using SF-36.RESULTS: At baseline, 98% patients had moderate-to-extreme pain, 85% had moderate/severe joint swelling, 64-79% had elevated inflammatory markers and HRQoL scores indicated impaired physical function. Percentage of patients with no/mild pain was numerically greater in most canakinumab groups vs. TA, 24-72h post-dose; difference significant for 150mg group at these time-points (P<0.05). Canakinumab 150mg was associated with significantly lower Likert scores for tenderness [OR, 3.2; 95% CI, 1.27-7.89; P50.014] and swelling (OR, 2.7; 95% CI, 1.09-6.50, P50.032) at 72h vs. TA; erythema was not different. Median CRP and SAA levels normalized by 7 days post-dose in most canakinumab groups, but remained elevated in TA. Physical function improved at 7 days postdose in all groups, highest improvement for canakinumab 150mg. SF-36 scores for physical functioning and bodily pain with canakinumab 150mg approached US general population scores by 7 days post-dose and exceeded normal values by 8 weeks post-dose.CONCLUSION: Canakinumab 150mg produced significantly greater and rapid pain-relief and improvements in HRQoL vs. TAin acute gouty arthritis patients.
Resumo:
The aim of radiotherapy is to deliver enough radiation to the tumor in order to achieve maximum tumour control in the irradiated volume with as few serious complications as possible with an irradiation dose as low as possible to normal tissue. The quality of radiotherapy is essential for optimal treatment and quality control is to reduce the bias in clinical trials avoiding possible major deviations. The assurance and quality control programs have been developed in large european (EORTC, GORTEC) and american cooperative groups (RTOG) of radiation oncology since the 1980s. We insist here on the importance of quality assurance in radiotherapy and the current status in this domain and the criteria for quality control especially for current clinical trials within GORTEC are discussed here.
Resumo:
Rapid response to : Madan M Rehani and Manorma Berry Radiation doses in computed tomography BMJ 2000; 320: 593-594
Resumo:
We compared the health-related quality-of-life of patients with newly diagnosed multiple myeloma aged over 65 years or transplant-ineligible in the pivotal, phase III FIRST trial. Patients received: i) continuous lenalidomide and low-dose dexamethasone until disease progression; ii) fixed cycles of lenalidomide and low-dose dexamethasone for 18 months; or iii) fixed cycles of melphalan, prednisone, thalidomide for 18 months. Data were collected using the validated questionnaires (QLQ-MY20, QLQ-C30, and EQ-5D). The analysis focused on the EQ-5D utility value and six domains pre-selected for their perceived clinical relevance. Lenalidomide and low-dose dexamethasone, and melphalan, prednisone, thalidomide improved patients' health-related quality-of-life from baseline over the duration of the study across all pre-selected domains of the QLQ-C30 and EQ-5D. In the QLQ-MY20, lenalidomide and low-dose dexamethasone demonstrated a significantly greater reduction in the Disease Symptoms domain compared with melphalan, prednisone, thalidomide at Month 3, and significantly lower scores for QLQ-MY20 Side Effects of Treatment at all post-baseline assessments except Month 18. Linear mixed-model repeated-measures analyses confirmed the results observed in the cross-sectional analysis. Continuous lenalidomide and low-dose dexamethasone delays disease progression versus melphalan, prednisone, thalidomide and has been associated with a clinically meaningful improvement in health-related quality-of-life. These results further establish continuous lenalidomide and low-dose dexamethasone as a new standard of care for initial therapy of myeloma by demonstrating superior health-related quality-of-life during treatment, compared with melphalan, prednisone, thalidomide.