294 resultados para micro-CT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Capsule Habitat parameters associated with 706 Barn Owl (Tyto alba) nesting boxes in Israel were analysed. Pairs bred in 259 of the boxes. The intensity of agricultural practices at nestbox sites were shown to have only a weak effect on aspects of Barn Owl breeding in this region.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Microphthalmia and anophthalmia are at the severe end of the spectrum of abnormalities in ocular development. A few genes (orthodenticle homeobox 2 [OTX2], retina and anterior neural fold homeobox [RAX], SRY-box 2 [SOX2], CEH10 homeodomain-containing homolog [CHX10], and growth differentiation factor 6 [GDF6]) have been implicated mainly in isolated micro/anophthalmia but causative mutations of these genes explain less than a quarter of these developmental defects. The essential role of the LIM homeobox 2 (LHX2) transcription factor in early eye development has recently been documented. We postulated that mutations in this gene could lead to micro/anophthalmia, and thus performed molecular screening of its sequence in patients having micro/anophthalmia. Methods: Seventy patients having non-syndromic forms of colobomatous microphthalmia (n=25), isolated microphthalmia (n=18), or anophthalmia (n=17), and syndromic forms of micro/anophthalmia (n=10) were included in this study after negative molecular screening for OTX2, RAX, SOX2, and CHX10 mutations. Mutation screening of LHX2 was performed by direct sequencing of the coding sequences and intron/exon boundaries. Results: Two heterozygous variants of unknown significance (c.128C > G [p.Pro43Arg]; c.776C > A [p.Pro259Gln]) were identified in LHX2 among the 70 patients. These variations were not identified in a panel of 100 control patients of mixed origins. The variation c.776C > A (p.Pro259Gln) was considered as non pathogenic by in silico analysis, while the variation c.128C > G (p.Pro43Arg) considered as deleterious by in silico analysis and was inherited from the asymptomatic father. Conclusions: Mutations in LHX2 do not represent a frequent cause of micro/anophthalmia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate if heroin and cocaine can be distinguished using dual-energy CT. MATERIALS AND METHODS: Twenty samples of heroin and cocaine at different concentrations and standardized compression (SC) were scanned in dual-energy mode on a newest generation Dual Energy 64-row MDCT scanner. CT number, spectral graphs, and dual-energy index (DEI) were evaluated. Results were prospectively tested on six original samples from a body packer. Wilcoxon's test was used for statistical evaluation. RESULTS: Values are given as median and range. Under SC, the CT number of cocaine samples (-29.87 Hounsfield unit (HU) [-125.85; 16.16 HU]) was higher than the CT number of heroin samples (-184.37 HU [-199.81; -159.25 HU]; p < 0.01). Slope of spectral curves for cocaine was -2.36 HU/keV [-7.15; -0.67 HU/keV], and for heroin, 1.75 HU/keV [1.28; 2.5 HU/keV] (p < 0.01). DEI was 0.0352 [0.0081; 0.0528] for cocaine and significantly higher than for heroin samples (-0.0127 [-0.0097; -0.0159]; p < 0.001). While CT number was inconclusive, all six original packs were correctly classified after evaluation of the spectral curve and DEI. In contrast to the CT number, slope of the spectral curve and DEI were independent of concentration and compression. CONCLUSION: The slope of the spectral curve and the DEI from dual-energy CT data can be used to distinguish heroin and cocaine in vitro; these results are independent of compression and concentration in the measured range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Multislice CT (MSCT) combined with D-dimer measurement can safely exclude pulmonary embolism in patients with a low or intermediate clinical probability of this disease. We compared this combination with a strategy in which both a negative venous ultrasonography of the leg and MSCT were needed to exclude pulmonary embolism. METHODS: We included 1819 consecutive outpatients with clinically suspected pulmonary embolism in a multicentre non-inferiority randomised controlled trial comparing two strategies: clinical probability assessment and either D-dimer measurement and MSCT (DD-CT strategy [n=903]) or D-dimer measurement, venous compression ultrasonography of the leg, and MSCT (DD-US-CT strategy [n=916]). Randomisation was by computer-generated blocks with stratification according to centre. Patients with a high clinical probability according to the revised Geneva score and a negative work-up for pulmonary embolism were further investigated in both groups. The primary outcome was the 3-month thromboembolic risk in patients who were left untreated on the basis of the exclusion of pulmonary embolism by diagnostic strategy. Clinicians assessing outcome were blinded to group assignment. Analysis was per protocol. This study is registered with ClinicalTrials.gov, number NCT00117169. FINDINGS: The prevalence of pulmonary embolism was 20.6% in both groups (189 cases in DD-US-CT group and 186 in DD-CT group). We analysed 855 patients in the DD-US-CT group and 838 in the DD-CT group per protocol. The 3-month thromboembolic risk was 0.3% (95% CI 0.1-1.1) in the DD-US-CT group and 0.3% (0.1-1.2) in the DD-CT group (difference 0.0% [-0.9 to 0.8]). In the DD-US-CT group, ultrasonography showed a deep-venous thrombosis in 53 (9% [7-12]) of 574 patients, and thus MSCT was not undertaken. INTERPRETATION: The strategy combining D-dimer and MSCT is as safe as the strategy using D-dimer followed by venous compression ultrasonography of the leg and MSCT for exclusion of pulmonary embolism. An ultrasound could be of use in patients with a contraindication to CT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Cervical foraminal injection performed with a direct foraminal approach may induce serious neurologic complications. We describe a technique of CT-guided cervical facet joint (CFJ) injection as an indirect foraminal injection, including feasibility and diffusion pathways of the contrast agent. Methods and materials: Retrospective study included 84 punctures in 65 consecutive patients presenting neck pain and/or radiculopathy related to osteoarthritis or soft disc herniation. CT images were obtained from C2 to T1 in supine position, with a metallic landmark on the skin. CFJ punctures were performed by MSK senior radiologists with a lateral approach. CT control of the CFJ opacification was performed after injections of contrast agent (1 ml), followed by slow-acting corticosteroid (25 mg). CFJ opacification was considered as successful when joint space and/or capsular recess opacification occurred. The diffusion of contrast agent in foraminal and epidural spaces was recorded. We assessed the epidural diffusion both on axial and sagittal images, with a classification in two groups (small diffusion or large diffusion). Results: CFJ opacification was successful in 82% (69/84). An epidural and/or foraminal opacification was obtained in 74% (51/69). A foraminal opacification occurred in 92% (47/51) and an epidural opacification in 63% (32/51), with small diffusion in 47% (15/32) and large diffusion in 53% (17/32). No complication occurred. Conclusion: CT- guided CFJ injection is easy to perform and safe. It is most often successful, with a frequent epidural and/or foraminal diffusion of the contrast agent. This technique could be an interesting and safe alternative to foraminal cervical injection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUMEN: La emergencia de nuevas ciencias y tecnologías vienen acompañadas de nuevas dinámicas en la producción, el uso y la diseminación de nuevos conocimientos científicos y tecnológicos. Estas nuevas dinámicas se reflejan en la reorganización de las actividades científicas, en la creación o la reorientación de nuevas temáticas en la investigación, en la emergencia de nuevas preocupaciones y debates sobre los riesgos e implicaciones sociales, y en la participación de nuevos actores en el desarrollo de la ciencia y la tecnología, entre otros factores. En este artículo se presentan los resultados del estudio sobre las funciones de un organismo con orígenes filantrópicos y no gubernamental que ha sido central en el desarrollo de los sistemas microelectromecánicos (MEMS) en México. Las funciones que se analizan han sido y son desarrolladas en las diferentes etapas del desarrollo de esta tecnología emergente en este país. Además de mostrar las funciones desempeñadas por este tipo de organismo, este texto se cuestiona sobre la modelización de las relaciones entre las diferentes entidades presentes en el desarrollo e instalación de nuevas tecnologías. En las conclusiones intentamos avanzar algunos elementos para tomar en cuenta estos organismos y enriquecer los estudios sociales sobre las nuevas ciencias y tecnologías. ABSTRACT: The emergence of new sciences and technologies come with new dynamics in the production, use and dissemination of new scientific and technological knowledge. These new dynamics are reflected in the reorganization of scientific activities, in creating or redirecting new topics in research, in the emergence of new concerns and debates about the risks and social implications, and the participation of new actors in the development of science and technology, among other factors. This article presents the results of the study on the functions of an organism with philanthropic and non-governmental sources that has been central to the development of microelectromechanical systems (MEMS) in Mexico. The functions have been discussed and are developed at different stages of development of this emerging technology in this country. In addition to showing the functions of such a body, this text is questioned on modeling the relationships between the various entities in the development and deployment of new technologies. In the conclusions we try moving some elements to take into account these organisms and enrich social studies on the new sciences and technologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'angio-CT post-mortem est un examen peu invasif qui permet d'investiguer le système vasculaire d'une manière détaillée impossible à obtenir lors d'une autopsie conventionnelle. Le groupe de recherche lausannois sur l'angio-CT a développé un protocole standardisé pour une technique appelée «angio-CT post-mortem en phases multiples», qui permet de réaliser des angio-CT de manière simple et d'améliorer le diagnostic radiologique. De plus, de nouveaux équipements incluant une pompe à perfusion, du matériel prêt à l'emploi et un produit de contraste spécifique ont été développés. L'angio-CT permet la détection d'une source d'hémorragie, d'une malformation du système vasculaire, de lésions d'artériosclérose, d'une occlusion d'un vaisseau et la visualisation de l'anatomie vasculaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. METHODS: We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDIvol), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. RESULTS: For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDIvol and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. CONCLUSION: We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine subregions of normal and abnormal cartilage in advanced stages of femorotibial osteoarthritis (OA) by mapping the entire femorotibial joint in a cohort of pre-total knee replacement (TKR) OA knees. DESIGN: We defined an areal subdivision of the femorotibial articular cartilage surface on CT arthrography (CTA), allowing the division of the femorotibial articular surface into multiple (up to n = 204 per knee) subregions and the comparison of the same areas between different knees. Two readers independently classified each cartilage area as normal, abnormal or non-assessable in 41 consecutive pre-TKR OA knees. RESULTS: A total of 6447 cartilage areas (from 41 knees) were considered assessable by both readers. The average proportion of preserved cartilage was lower in the medial femorotibial joint than in the lateral femorotibial joint for both readers (32.0/69.8% and 33.9/68.5% (medial/lateral) for reader 1 and 2 respectively, all P < 0.001). High frequencies of normal cartilage were observed at the posterior aspect of the medial condyle (up to 89%), and the anterior aspect of the lateral femorotibial compartment (up to 100%). The posterior aspect of the medial condyle was the area that most frequently exhibited preserved cartilage in the medial femorotibial joint, contrasting with the high frequency of cartilage lesions in the rest of that compartment. CONCLUSIONS: Cartilage at the posterior aspect of the medial condyle, and at the anterior aspect of the lateral femorotibial compartment, may be frequently preserved in advanced grades of OA.