302 resultados para heart arrhythmia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This longitudinal study aimed at comparing heart rate variability (HRV) in elite athletes identified either in 'fatigue' or in 'no-fatigue' state in 'real life' conditions. METHODS: 57 elite Nordic-skiers were surveyed over 4 years. R-R intervals were recorded supine (SU) and standing (ST). A fatigue state was quoted with a validated questionnaire. A multilevel linear regression model was used to analyze relationships between heart rate (HR) and HRV descriptors [total spectral power (TP), power in low (LF) and high frequency (HF) ranges expressed in ms(2) and normalized units (nu)] and the status without and with fatigue. The variables not distributed normally were transformed by taking their common logarithm (log10). RESULTS: 172 trials were identified as in a 'fatigue' and 891 as in 'no-fatigue' state. All supine HR and HRV parameters (Beta+/-SE) were significantly different (P<0.0001) between 'fatigue' and 'no-fatigue': HRSU (+6.27+/-0.61 bpm), logTPSU (-0.36+/-0.04), logLFSU (-0.27+/-0.04), logHFSU (-0.46+/-0.05), logLF/HFSU (+0.19+/-0.03), HFSU(nu) (-9.55+/-1.33). Differences were also significant (P<0.0001) in standing: HRST (+8.83+/-0.89), logTPST (-0.28+/-0.03), logLFST (-0.29+/-0.03), logHFST (-0.32+/-0.04). Also, intra-individual variance of HRV parameters was larger (P<0.05) in the 'fatigue' state (logTPSU: 0.26 vs. 0.07, logLFSU: 0.28 vs. 0.11, logHFSU: 0.32 vs. 0.08, logTPST: 0.13 vs. 0.07, logLFST: 0.16 vs. 0.07, logHFST: 0.25 vs. 0.14). CONCLUSION: HRV was significantly lower in 'fatigue' vs. 'no-fatigue' but accompanied with larger intra-individual variance of HRV parameters in 'fatigue'. The broader intra-individual variance of HRV parameters might encompass different changes from no-fatigue state, possibly reflecting different fatigue-induced alterations of HRV pattern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nitric oxide synthase (NOS) is strongly and transiently expressed in the developing heart but its function is not well documented. This work examined the role, either protective or detrimental, that endogenous and exogenous NO could play in the functioning of the embryonic heart submitted to hypoxia and reoxygenation. Spontaneously beating hearts isolated from 4-day-old chick embryos were either homogenized to determine basal inducible NOS (iNOS) expression and activity or submitted to 30 min anoxia followed by 100 min reoxygenation. The chrono-, dromo- and inotropic responses to anoxia/reoxygenation were determined in the presence of NOS substrate (L-arginine 10 mM), NOS inhibitor L-NIO (1-5 mM), or NO donor (DETA NONOate 10-100 microM). Myocardial iNOS was detectable by immunoblotting and its activity was specifically decreased by 53% in the presence of 5 mM L-NIO. L-Arginine, L-NIO and DETA NONOate at 10 microM had no significant effect on the investigated functional parameters during anoxia/reoxygenation. However, irrespective of anoxia/reoxygenation, DETA NONOate at 100 microM decreased ventricular shortening velocity by about 70%, and reduced atrio-ventricular propagation by 23%. None of the used drugs affected atrial activity and hearts of all experimental groups fully recovered at the end of reoxygenation. These findings indicate that (1) by contrast with adult heart, endogenously released NO plays a minor role in the early response of the embryonic heart to reoxygenation, (2) exogenous NO has to be provided at high concentration to delay postanoxic functional recovery, and (3) sinoatrial pacemaker cells are the less responsive to NO.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although the physiological and pharmacological evidences suggest a role for angiotensin II (Ang II) with the mammalian heart, the source and precise location of Ang II are unknown. To visualize and quantitate Ang II in atria, ventricular walls and interventricular septum of the rat and human heart and to explore the feasibility of local Ang II production and function, we investigated by different methods the expression of proteins involved in the generation and function of Ang II. We found mRNA of angiotensinogen (Ang-N), of angiotensin converting enzyme, of the angiotensin type receptors AT(1A) and AT(2) (AT(1B) not detected) as well as of cathepsin D in any part of the hearts. No renin mRNA was traceable. Ang-N mRNA was visualized by in situ hybridization in atrial ganglial neurons. Ang II and dopamine-β-hydroxylase (DβH) were either colocalized inside the same neuronal cell or the neurons were specialized for Ang II or DβH. Within these neurons, the vesicular acetylcholine transporter (VAChT) was neither colocalized with Ang II nor DβH, but VAChT-staining was found with synapses en passant encircle these neuronal cells. The fibers containing Ang II exhibited with blood vessels and with cardiomyocytes supposedly angiotensinergic synapses en passant. In rat heart, right atrial median Ang II concentration appeared higher than septal and ventricular Ang II. The distinct colocalization of neuronal Ang II with DβH in the heart may indicate that Ang II participates together with norepinephrine in the regulation of cardiac functions: Produced as a cardiac neurotransmitter Ang II may have inotropic, chronotropic or dromotropic effects in atria and ventricles and contributes to blood pressure regulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The Marburg Heart Score (MHS) aims to assist GPs in safely ruling out coronary heart disease (CHD) in patients presenting with chest pain, and to guide management decisions. AIM: To investigate the diagnostic accuracy of the MHS in an independent sample and to evaluate the generalisability to new patients. DESIGN AND SETTING: Cross-sectional diagnostic study with delayed-type reference standard in general practice in Hesse, Germany. METHOD: Fifty-six German GPs recruited 844 males and females aged ≥ 35 years, presenting between July 2009 and February 2010 with chest pain. Baseline data included the items of the MHS. Data on the subsequent course of chest pain, investigations, hospitalisations, and medication were collected over 6 months and were reviewed by an independent expert panel. CHD was the reference condition. Measures of diagnostic accuracy included the area under the receiver operating characteristic curve (AUC), sensitivity, specificity, likelihood ratios, and predictive values. RESULTS: The AUC was 0.84 (95% confidence interval [CI] = 0.80 to 0.88). For a cut-off value of 3, the MHS showed a sensitivity of 89.1% (95% CI = 81.1% to 94.0%), a specificity of 63.5% (95% CI = 60.0% to 66.9%), a positive predictive value of 23.3% (95% CI = 19.2% to 28.0%), and a negative predictive value of 97.9% (95% CI = 96.2% to 98.9%). CONCLUSION: Considering the diagnostic accuracy of the MHS, its generalisability, and ease of application, its use in clinical practice is recommended.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Owing to its high fat content, the classical Western diet has a range of adverse effects on the heart, including enhanced inflammation, hypertrophy, and contractile dysfunction. Proinflammatory factors secreted by cardiac cells, which are under the transcriptional control of nuclear factor-κB (NF-κB), may contribute to heart failure and dilated cardiomyopathy. The underlying mechanisms are complex, since they are linked to systemic metabolic abnormalities and changes in cardiomyocyte phenotype. Peroxisome proliferator-activated receptors (PPARs) are transcription factors that regulate metabolism and are capable of limiting myocardial inflammation and hypertrophy via inhibition of NF-κB. Since PPARβ/δ is the most prevalent PPAR isoform in the heart, we analyzed the effects of the PPARβ/δ agonist GW501516 on inflammatory parameters. A high-fat diet induced the expression of tumor necrosis factor-α, monocyte chemoattractant protein-1, and interleukin-6, and enhanced the activity of NF-κB in the heart of mice. GW501516 abrogated this enhanced proinflammatory profile. Similar results were obtained when human cardiac AC16 cells exposed to palmitate were coincubated with GW501516. PPARβ/δ activation by GW501516 enhanced the physical interaction between PPARβ/δ and p65, which suggests that this mechanism may also interfere NF-κB transactivation capacity in the heart. GW501516-induced PPARβ/δ activation can attenuate the inflammatory response induced in human cardiac AC16 cells exposed to the saturated fatty acid palmitate and in mice fed a high-fat diet. This is relevant, especially taking into account that PPARβ/δ has been postulated as a potential target in the treatment of obesity and the insulin resistance state.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The goal of this study was to determine whether subclinical thyroid dysfunction was associated with incident heart failure (HF) and echocardiogram abnormalities. BACKGROUND: Subclinical hypothyroidism and hyperthyroidism have been associated with cardiac dysfunction. However, long-term data on the risk of HF are limited. METHODS: We studied 3,044 adults>or=65 years of age who initially were free of HF in the Cardiovascular Health Study. We compared adjudicated HF events over a mean 12-year follow-up and changes in cardiac function over the course of 5 years among euthyroid participants, those with subclinical hypothyroidism (subdivided by thyroid-stimulating hormone [TSH] levels: 4.5 to 9.9, >or=10.0 mU/l), and those with subclinical hyperthyroidism. RESULTS: Over the course of 12 years, 736 participants developed HF events. Participants with TSH>or=10.0 mU/l had a greater incidence of HF compared with euthyroid participants (41.7 vs. 22.9 per 1,000 person years, p=0.01; adjusted hazard ratio: 1.88; 95% confidence interval: 1.05 to 3.34). Baseline peak E velocity, which is an echocardiographic measurement of diastolic function associated with incident HF in the CHS cohort, was greater in those patients with TSH>or=10.0 mU/l compared with euthyroid participants (0.80 m/s vs. 0.72 m/s, p=0.002). Over the course of 5 years, left ventricular mass increased among those with TSH>or=10.0 mU/l, but other echocardiographic measurements were unchanged. Those patients with TSH 4.5 to 9.9 mU/l or with subclinical hyperthyroidism had no increase in risk of HF. CONCLUSIONS: Compared with euthyroid older adults, those adults with TSH>or=10.0 mU/l have a moderately increased risk of HF and alterations in cardiac function but not older adults with TSH<10.0 mU/l. Clinical trials should assess whether the risk of HF might be ameliorated by thyroxine replacement in individuals with TSH>or=10.0 mU/l.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this study was to assess the association between frailty and risk for heart failure (HF) in older adults. BACKGROUND: Frailty is common in the elderly and is associated with adverse health outcomes. Impact of frailty on HF risk is not known. METHODS: We assessed the association between frailty, using the Health ABC Short Physical Performance Battery (HABC Battery) and the Gill index, and incident HF in 2825 participants aged 70 to 79 years. RESULTS: Mean age of participants was 74 ± 3 years; 48% were men and 59% were white. During a median follow up of 11.4 (7.1-11.7) years, 466 participants developed HF. Compared to non-frail participants, moderate (HR 1.36, 95% CI 1.08-1.71) and severe frailty (HR 1.88, 95% CI 1.02-3.47) by Gill index was associated with a higher risk for HF. HABC Battery score was linearly associated with HF risk after adjusting for the Health ABC HF Model (HR 1.24, 95% CI 1.13-1.36 per SD decrease in score) and remained significant when controlled for death as a competing risk (HR 1.30; 95% CI 1.00-1.55). Results were comparable across age, sex, and race, and in sub-groups based on diabetes mellitus or cardiovascular disease at baseline. Addition of HABC Battery scores to the Health ABC HF Risk Model improved discrimination (change in C-index, 0.014; 95% CI 0.018-0.010) and appropriately reclassified 13.4% (net-reclassification-improvement 0.073, 95% CI 0.021-0.125; P = .006) of participants (8.3% who developed HF and 5.1% who did not). CONCLUSIONS: Frailty is independently associated with risk of HF in older adults.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The Healthy Heart Kit (HHK) is a risk management and patient education kit for the prevention of cardiovascular disease (CVD) and the promotion of CV health. There are currently no published data examining predictors of HHK use by physicians. The main objective of this study was to examine the association between physicians' characteristics (socio-demographic, cognitive, and behavioural) and the use of the HHK. METHODS: All registered family physicians in Alberta (n=3068) were invited to participate in the "Healthy Heart Kit" Study. Consenting physicians (n=153) received the Kit and were requested to use it for two months. At the end of this period, a questionnaire collected data on the frequency of Kit use by physicians, as well as socio-demographic, cognitive, and behavioural variables pertaining to the physicians. RESULTS: The questionnaire was returned by 115 physicians (follow-up rate = 75%). On a scale ranging from 0 to 100, the mean score of Kit use was 61 [SD=26]. A multiple linear regression showed that "agreement with the Kit" and the degree of "confidence in using the Kit" was strongly associated with Kit use, explaining 46% of the variability for Kit use. Time since graduation was inversely associated with Kit use, and a trend was observed for smaller practices to be associated with lower use. CONCLUSION: Given these findings, future research and practice should explore innovative strategies to gain initial agreement among physicians to employ such clinical tools. Participation of older physicians and solo-practitioners in this process should be emphasized.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a device made of artificial muscle for the treatment of end-stage heart failure as an alternative to current heart assist devices. The key component is a matrix of nitinol wires and aramidic fibers called Biometal muscle (BM). When heated electrically, it produces a motorless, smooth, and lifelike motion. The BM is connected to a carbon fiber scaffold, tightening the heart and providing simultaneous assistance to the left and right ventricles. A pacemaker-like microprocessor drives the contraction of the BM. We tested the device in a dedicated bench model of diseased heart. It generated a systolic pressure of 75 mm Hg and ejected a maximum of 330 ml/min, with an ejection fraction of 12%. The device required a power supply of 6 V, 250 mA. This could be the beginning of an era in which BMs integrate or replace the mechanical function of natural muscles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: With the aging of the population, the heart failure (HF) incidence and prevalence trends are expected to significantly worsen unless concentrated prevention efforts are undertaken. ECG abnormalities are common in the elderly but data are limited for their association with HF risk. Objective: To assess whether baseline ECG abnormalities or dynamic changes are associated with an increased risk of HF. Method: A prospective cohort study of 2915 participants aged 70 to 79 years without a preexisting HF followed for a median period of 11.4 (IQR 7.0-11.7) years from the Health Aging and Body Composition study. The Minnesota Code was used to define major and minor ECG abnormalities at baseline and at 4-year. Main outcome measure was adjudicated incident HF events. Using Cox models, the (1) the association between ECG abnormalities and incident HF and (2) incremental value of adding ECG to the Health ABC HF Risk Score, was assessed. Results: At baseline, 380 participants (13.0%) had minor and 620 (21.3%) had major ECG abnormalities. During follow-up, 485 (16.6%) participants developed incident HF. After adjusting for the eight clinical variables in the Health ABC HF Risk Score, the hazard ratio (HR) was 1.27 (95% confidence interval [CI] 0.96-1.68) for minor and 1.99 (CI 1.61-2.44) for major ECG abnormalities (P for trend <0.001) compared to no ECG abnormalities. The association did not change according to presence of baseline CHD. At 4-year, 263 participants developed new and 549 had persistent abnormalities and both were associated with increased HF risk (HR = 1.94, CI 1.38-2.72 for new and HR=2.35, CI 1.82-3.02 for persistent compared to no ECG abnormalities). Baseline ECG correctly reclassified 10.6% of overall participants across the categories of the Health ABC HF Risk Score. Conclusion: Among older adults, baseline ECG abnormalities and changes in them over time are common; both are associated with an increased risk of HF. Whether ECG should be incorporated in routine screening of older adults should be evaluated in randomized controlled trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Resistin is associated with inflammation and insulin resistance and exerts direct effects on myocardial cells including hypertrophy and altered contraction. We investigated the association of serum resistin concentrations with risk for incident heart failure (HF) in humans. METHODS AND RESULTS: We studied 2902 older persons without prevalent HF (age, 73.6+/-2.9 years; 48.1% men; 58.8% white) enrolled in the Health, Aging, and Body Composition (Health ABC) Study. Correlation between baseline serum resistin concentrations (20.3+/-10.0 ng/mL) and clinical variables, biochemistry panel, markers of inflammation and insulin resistance, adipocytokines, and measures of adiposity was weak (all rho <0.25). During a median follow-up of 9.4 years, 341 participants (11.8%) developed HF. Resistin was strongly associated with risk for incident HF in Cox proportional hazards models controlling for clinical variables, biomarkers, and measures of adiposity (HR, 1.15 per 10.0 ng/mL in adjusted model; 95% CI, 1.05 to 1.27; P=0.003). Results were comparable across sex, race, diabetes mellitus, and prevalent and incident coronary heart disease subgroups. In participants with available left ventricular ejection fraction at HF diagnosis (265 of 341; 77.7%), association of resistin with HF risk was comparable for cases with reduced versus preserved ejection fraction. CONCLUSIONS: Serum resistin concentrations are independently associated with risk for incident HF in older persons.