210 resultados para Rectum prosthesis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is increasing evidence that modular neck stems are prone to corrosion-related complications. Recent studies showed elevated metal ions levels and occasional pseudotumor formation in patients with such implants. The purpose of this study was to compare systemic metal-ion levels in patients after primary THA with modular neck stems to those of patients after non-modular implants. To our knowledge, this is the first cohort study including a control group, THA without CoCr heads and dry-assembled neck-stem connections. Methods: 50 patients after THA at a minimum follow-up of 1 year have been selected for the study. Patients with multiple prosthesis or other implants have been deselected. All received a cementless SPS stem from Symbios (Ti6Al4V). 40 patients have the modular neck (CoCr) version and 10 a monobloc version. All bearings were either ceramic-ceramic or ceramic-polyethylene to minimize other sources of CoCr ion release. In the modular group, the neck was chosen pre-operatively based on a 3D planning, allowing for a dry assembly of the stem and neck on the back table before implantation. A plasma system coupled to mass spectrometry was used for a complete elementary quantification in blood and serum separately. Clinical outcome was measured using the Oxford Hip Score. Results : Complete data sets of 29 patients (24 in the modular neck-group (10male, mean age 63y, 35-84y) and 5 in the monobloc-group (3 male, 69 y, 51-83y) are available to date. Mean Co blood levels were .95 ug/L (.14-12.4) in the modular group vs .27 ug/L (.10-.73) in the monobloc group (p=.2). Respective values for Cr were significantly higher in the modular group (.99 g/L; range .75-1.21) compared to those in the monobloc group (.74 g/L ;.62-.86; p=.001). No significant difference was found when comparing serum levels. 5/24 patients had Co levels above 1 g/L (12/24 for Cr), which is by some considered as a relevant elevation. The maximum Co level was measured in an asymptomatic patient. The Oxford Hip Scores were similar in both groups. Conclusion: Cr levels were significantly elevated in the modular neck group compared to those in the monobloc group. 1/24 patients with a modular prosthesis exhibited Co levels, which are beyond the threshold accepted even for metal-on-metal bearing couples. These results have contributed to our decision to abandon the use of modular neck stems. Routine follow-up including annual measurements of systemic CoCr concentrations should be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The microbiological diagnosis of periprosthetic joint infection (PJI) is crucial for successful antimicrobial treatment. Cultures have limited sensitivity, especially in patients receiving antibiotics. We evaluated the value of multiplex PCR for detection of microbial DNA in sonication fluid from removed orthopedic prostheses. Cases of PJI in which the prosthesis (or part of it) was removed were prospectively included. The removed implant was sonicated, and the resulting sonication fluid was cultured and subjected to multiplex PCR. Of 37 PJI cases (17 hip prostheses, 14 knee prostheses, 4 shoulder prostheses, 1 elbow prosthesis, and 1 ankle prosthesis), pathogens were identified in periprosthetic tissue in 24 (65%) cases, in sonication fluid in 23 (62%) cases, and by multiplex PCR in 29 (78%) cases. The pathogen was detected in 5 cases in sonication fluid only (Propionibacterium acnes in all cases; none of these patients had previously received antibiotics) and in 11 cases by multiplex PCR only (all of these patients had previously received antibiotics). After exclusion of 8 cases caused by P. acnes or Corynebacterium species, which cannot be detected due to the absence of specific primers in the PCR kit, sonication cultures were positive in 17 cases and multiplex PCR sonication cultures were positive in 29 cases (59% versus 100%, respectively; P < 0.01). Among 19 cases (51%) receiving antibiotics, multiplex PCR was positive in all 19 (100%), whereas sonication cultures grew the organism in 8 (42%) (P < 0.01). Multiplex PCR of sonication fluid is a promising test for diagnosis of PJI, particularly in patients who previously received antibiotics. With modified primer sets, multiplex PCR has the potential for further improvement of the diagnosis of PJI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Open surgery is still the main treatment of complex abdominal aortic aneurysm. Nevertheless, this approach is associated with major complications and high mortality rate. Therefore the fenestrated endograft has been used to treat the juxtarenal aneurysms. Unfortunately, no randomised controlled study is available to assess the efficacy of such devices. Moreover, the costs are still prohibitive to generalise this approach. Alternative treatments such as chimney or sandwich technique are being evaluated in order to avoid theses disadvantages. The aim of this paper is to present the endovascular approach to treat juxtarenal aneurysm and to emphasize that this option should be used only by highly specialized vascular centres.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Anorectal anomalies occurring with other anomalies or as part of syndromes were analyzed to determine how their epidemiological characteristics differed from those of isolated anal anomalies. Almost 15% of cases were chromosomal, monogenic or teratogenic syndromes, whereas the rest were of unknown cause including sequences (9.3%), VACTERL associations (15.4%) and multiple congenital anomalies (MCA) (60.2%). Almost half of babies with MCA had one or two VACTERL anomalies with distribution frequencies that did not differ significantly from those in babies with the full VACTERL association. There were considerable differences in the frequency of the VACTERL association among babies with different types of anorectal anomaly. Babies with anal anomalies occurring with sequences, VACTERL or MCA showed the same sex differences as babies with isolated anal anomalies, namely male predominance in anal atresia without fistula or cloaca, no sex difference in anal atresia with fistula, and female predominance in ectopic anus and congenital anal fistula. These anomalies, however, were associated with significantly lower mean gestational lengths and birth weights, and higher frequencies of fetal death and pregnancy termination than babies with isolated anal anomalies. Twins were more frequent in sequences, VACTERL and MCA than in isolated anomalies, monogenic syndromes or chromosome anomalies. Five cases were conjoined twins, representing 15% of all cases of twin pregnancies with an anal anomaly. Indeterminate sex was more frequent in babies with anal atresias without fistula than in those with fistula. Anal anomalies are defects of blastogenesis attributable to disorders in expression of pattern determining genes. The differential sex involvement in different types of anal anomaly may be manifestations of expression of the HY/SRY genes during blastogenesis or of X-linkage.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: We report a case of cefepime intoxication with acute severe neurologic symptoms, which was treated by temporary hemodialysis. Patients (or Materials) and Methods: Cefepime 2 g BID for endovascular prosthesis infection was prescribed to a frail, chronically ill 88-year-old woman with a serum creatinine of 199 μmol/L and an estimated creatinine clearance of 13 mL/min (Cockroft formula). Two days later, she was transferred to a neurocritical care unit because of acute aphasia, myoclonic jerks, and delirium with a Glasgow coma scale score of 12/15. The following day, in the absence of other causes, cefepime intoxication was hypothesized, and cefepime was withdrawn after a total of 7 doses = 14 g. Over the next 24 hours, two 3-hour hemodialysis (HD) sessions were performed under cefepime concentration monitoring. Results: Cefepime plasma levels were measured by liquid chromatography/ mass spectrometry. There is no validated reference range, but a study (Chapuis T et al, Critical Care, 2010) found a 50% risk of neurotoxicity with residual levels > 15 mg/L. In our patient, levels were 83.3 mg/L 10 hours after last dose, 24.1 mg/L immediately after the first HD session, 13.4 mg/L immediately before the second HD session, and 2.5 mg/L immediately after the second HD session. The patient made a full clinical recovery over the next 48 hours. The 70% to 80% fall in plasmatic levels observed during each HD session is in accordance with literature data (Schmaldienst S et al, Eur J Clin Pharmacol, 2000, and Manyor LM et al, Pharmacotherapy, 2008). According to kinetic simulation, cefepime dropped at a concentration < 15 mg/L 15 hours earlier with HD than it would have without. Conclusion: Neuropsychiatric adverse effects of beta-lactam antibiotics can be easily overlooked by clinicians. One should be especially cautious with their use in very old and frail patients in whom plasma creatinine poorly estimates renal function and cognitive impairment is highly prevalent. Temporary hemodialysis effectively clears cefepime, but its role in hastening clinical recovery may be limited.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim  Avoiding 'mini-laparotomy' to extract a colectomy specimen may decrease wound complications and further improve recovery after laparoscopic surgery. The aim of this study was to develop a new technique for transrectal specimen extraction (TRSE) and to compare it with conventional laparoscopy (CL) for left sided colectomy. Method  Eleven patients with benign disease requiring either sigmoid or left colon resection underwent TRSE. The unfired circular stapler was inserted transanally and used as a guide to suture-close the recto-sigmoid junction laparoscopically and as a handle to pull the sutured sigmoid through the opened rectum inside a laparoscopic camera bag. The anvil was inserted into the lumen of the intussuscepted sigmoid and pushed to the level of the anastomosis. The anastomosis was fashioned end-to-end in the first patients and side-to-end in the following patients to improve safety. Intra-operative and postoperative outcomes of patients undergoing TRSE were compared with those of a group of 20 patients undergoing CL, who were matched for type of resection, body mass index and age. Results  The procedure was successful in all but the first patient who was converted to conventional laparoscopic colectomy without any additional morbidity. Two patients in the end-to-end anastomosis group, but none in the side-to-end group, developed peri-anastomotic sepsis. Compared with CL, patients undergoing TRSE did not show any significant differences in operative time, recovery or morbidity. Conclusion  Transrectal specimen extraction after left colectomy using the circular stapler technique is feasible. A side-to-end anastomosis appears safer than an end-to-end anastomosis. Further studies are needed to explore the potential advantages of this procedure over CL.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With advances in heart transplantation, a growing number of recipients are at risk of developing gastrointestinal disease. We reviewed our experience with gastrointestinal disease in 92 patients undergoing 93 heart transplants. All had follow-up, with the median time 4.8 years (range 0.5-9.6 years). During the period of the study we progressively adopted a policy of low immunosuppression aiming toward monotherapy with cyclosporine. Nineteen patients (20.6%) developed 28 diseases related to the gastrointestinal tract. Thirteen patients required 18 surgical interventions, five as emergencies: closure of a duodenal ulcer, five cholecystectomies (one with biliary tract drainage), a sigmoid resection for a diverticulitis with a colovesical fistula, a colostomy followed by a colostomy takedown for an iatrogenic colon perforation, appendectomy, two anorectal procedures, and six abdominal wall herniorrhaphies. At the onset of gastrointestinal disease, 8 patients were on standard triple-drug immunosuppression, all of them within 6 months of transplantation; 13 were on double-drug immunosuppression; and 7 were on cyclosporine alone. All the patients with perforations/fistulas were on steroids. Among the 11 infectious or potentially infectious diseases, 10 were on triple- or double-drug immunosuppression. One death, a patient who was on triple-drug immunosuppression, had a postmortem diagnosis of necrotic and hemorrhagic pancreatitis. Except for an incisional hernia following a laparoscopic cholecystectomy, there was no morbidity and, importantly, no septic complications. We concluded that a low immunosuppression policy is likely to be responsible for the low morbidity and mortality of posttransplant gastrointestinal disease, with a lower incidence of viscous perforation/fistula and infectious gastrointestinal disease.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We conducted this study to determine the relative influence of various mechanical and patient-related factors on the incidence of dislocation after primary total hip asthroplasty (THA). Of 2,023 THAs, 21 patients who had at least 1 dislocation were compared with a control group of 21 patients without dislocation, matched for age, gender, pathology, and year of surgery. Implant positioning, seniority of the surgeon, American Society of Anesthesiologists (ASA) score, and diminished motor coordination were recorded. Data analysis included univariate and multivariate methods. The dislocation risk was 6.9 times higher if total anteversion was not between 40 degrees and 60 degrees and 10 times higher in patients with high ASA scores. Surgeons should pay attention to total anteversion (cup and stem) of THA. The ASA score should be part of the preoperative assessment of the dislocation risk.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The estimation of muscle forces in musculoskeletal shoulder models is still controversial. Two different methods are widely used to solve the indeterminacy of the system: electromyography (EMG)-based methods and stress-based methods. The goal of this work was to evaluate the influence of these two methods on the prediction of muscle forces, glenohumeral load and joint stability after total shoulder arthroplasty. An EMG-based and a stress-based method were implemented into the same musculoskeletal shoulder model. The model replicated the glenohumeral joint after total shoulder arthroplasty. It contained the scapula, the humerus, the joint prosthesis, the rotator cuff muscles supraspinatus, subscapularis and infraspinatus and the middle, anterior and posterior deltoid muscles. A movement of abduction was simulated in the plane of the scapula. The EMG-based method replicated muscular activity of experimentally measured EMG. The stress-based method minimised a cost function based on muscle stresses. We compared muscle forces, joint reaction force, articular contact pressure and translation of the humeral head. The stress-based method predicted a lower force of the rotator cuff muscles. This was partly counter-balanced by a higher force of the middle part of the deltoid muscle. As a consequence, the stress-based method predicted a lower joint load (16% reduced) and a higher superior-inferior translation of the humeral head (increased by 1.2 mm). The EMG-based method has the advantage of replicating the observed cocontraction of stabilising muscles of the rotator cuff. This method is, however, limited to available EMG measurements. The stress-based method has thus an advantage of flexibility, but may overestimate glenohumeral subluxation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND AIM OF THE STUDY: Transapical transcatheter aortic valve replacement (TAVR) is a new minimally invasive technique with a known risk of unexpected intra-procedural complications. Nevertheless, the clinical results are good and the limited amount of procedural adverse events confirms the usefulness of a synergistic surgical/anesthesiological management in case of unexpected emergencies. METHODS: A review was made of the authors' four-year database and other available literature to identify major and minor intra-procedural complications occurring during transapical TAVR procedures. All implants were performed under general anesthesia with a balloon-expandable Edwards Sapien stent-valve, and followed international guidelines on indications and techniques. RESULTS: Procedural success rates ranged between 94% and 100%. Life-threatening apical bleeding occurred very rarely (0-5%), and its incidence decreased after the first series of implants. Stent-valve embolization was also rare, with a global incidence ranging from 0-2%, with evidence of improvement after the learning curve. Rates of valve malpositioning ranged from 0% to < 3%, whereas the risk of coronary obstruction ranged from 0% to 3.5%. Aortic root rupture and dissection were dramatic events reported in 0-2% of transapical cases. Stent-valve malfunction was rarely reported (1-2%), whereas the valve-in-valve bailout procedure for malpositioning, malfunctioning or severe paravalvular leak was reported in about 1.0-3.5% of cases. Sudden hemodynamic management and bailout procedures such as valve-in-valve rescue or cannulation for cardiopulmonary bypass were more effective when planned during the preoperative phase. CONCLUSION: Despite attempts to avoid pitfalls, complications during transapical aortic valve procedures still occur. Preoperative strategic planning, including hemodynamic status management, alternative cannulation sites and bailout procedures, are highly recommended, particularly during the learning curve of this technique.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Screening for osteoporosis is important in older patients admitted to post-acute rehabilitation. However, DXA measurement is sometimes difficult to perform because of difficulties in positioning the patient and artefacts (osteoarthritis, prosthesis). The objectives were to determine the prevalence of unknown clinical osteoporosis in rehab patients and to determine new strategies for identifying clinical osteoporosis in this population. Method: Over a 9-months period, patients consecutively admitted to post-acute rehabilitation were included in th stdy. Patients with osteoporosis diagnosis, and those with terminal illness or severe physical limitations were excluded. Patients underwent Bone Mineral Density (BMD) by DXA and Vertebral Fracture Assessment (VFA). Clinical osteoporosis was defined as BMD ≤-2.5 SD at any site (lumbar spine, femoral neck, total hip or distal radius), ≥1 vertebral fracture, ≥1 hip fracture, or another fragility fracture and BMD ≤-2 SD. Results: Overall, 102 (17.0%) of the 600 patients admitted to rehab refused to participate in the study or were unable to consent. Among the 498 remaining patients, 99 (19.9%) were excluded because of already known diagnosis of osteoporosis, 101 (20.3%) were excluded because of terminal illness, severe physical limitations, and 45 (9.0%) because of inability to perform DXA during the stay (death, hospital transfer). Overall, 253 patients were assessed with DXA and VFA (166 women, mean age 83±7 years, mean BMI 27±6 kg/m2, and 87 men, mean age 82±6 yrs, mean BMI 27±5 kg/m2). Of these, 70% had history of fall during the last 6 months and 9.1% had hip fracture history. Prevalence of osteoporotic vertebral fracture was 36% in women and 32% in men. Overall, 152 (60.1%) patients had clinical osteoporosis (women: 67%; men: 46%) according to above criteria. Hip fracture history and vertebral fracture assessment identified correctly 105 (69.1%) of these 152 patients. Conclusion: A high prevalence of osteoporosis was observed in this population of rehab patients. Osteoporosis status should be systematically assessed in these patients at high fall risk, at least with careful history of hip fracture and an assessment for vertebral fractures with spine X-ray.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: EORTC trial 22991 randomly assessed the addition of concomitant and adjuvant short-term hormonal therapy to curative conformal/intensity-modulated radiotherapy (RT) for intermediate risk localized prostate cancer. We report the acute toxicity (assessed weekly during RT) for the organs at risk (genito-urinary (GU) and gastro-intestinal (GI)) in relation to radiation parameters. Material and Methods: Eligibility criteria were age _80 years, PSA _ 50 ng/ml, N0M0 and either tumour stage cT2a (1997 UICC TNM) or cT1b-c combined with PSA_10 ng/ml and/or Gleason score _7. We report toxicity for all eligible patients who received the planned RT with documented acute toxicity (CTCAEv.2) and RT-quality assurance parameters. The RT dose (70 Gy, 74 Gy or 78 Gy) and technique (3DCRT vs IRMT) were per institution choice, the randomization was stratified for institution. Statistical significance was set at 0.05. (ClinicalTrials.gov: NCT00021450) Results: Of 819 randomized patients, 28 were excluded from the analysis (3 with <60 Gy RT, 25 with missing information). Of the 791 analysed patients, 652 (82.4%) were treated with 3D-CRT, 139 with IMRT. In the 3DCRT group, 195 patients (29.9%) were treated with a total prescribed dose of 70 Gy; 376 (57.7%) with 74 Gy and 81 (12.4%) with 78 Gy. In the IMRT group, 28 (20.1%) were treated to a total dose of 74 Gy and 111 (79.9%) with 78 Gy. Overall, only 7 of 791 patients (0.9%) had grade 3 GI toxicity during RT: diarrhea (N = 6), rectal bleeding (N = 1) and proctitis (N = 1). Fifty patients (6.3%) had grade 3 GU toxicity: urinary frequency (N = 38, 4.6%), dysuria (N = 14, 1.7%), urinary retention (N = 11, 1.3%), urinary incontinence (N = 2) and hematuria (N = 1). No grade 4 toxicity was reported. Hormonal treatment did not influence the risk of side effects (p>0.05). The risk of grade _2 GI toxicity significantly correlated to D50%-rectum (p = 0.004) with a cut-of value of 44 Gy. The risk of grade _2 GU toxicity was moderately affected by Dmax-bladder (p = 0.051). Overall, only 14 patients (1.8%) had residual grade 3 toxicities one month after RT. Conclusion: 3D-CRT and IMRT up to 78 Gy is well tolerated. Dmaxbladder and D50%-rectum were related to the risk of grade_2 GU and GI toxicity, respectively. IMRT lowered D50% rectum and Dmax-bladder. An irradiated volume >400 cc for 3D-RT and a dose of 78 Gy, even for IMRT, negatively affected those parameters and increased the risk for toxicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Accurate measurement of knee kinematics during functional activities suffers mainly from soft tissue artifact (STA): the combination of local surface deformations and rigid movement of markers relative to the underlying bone (also called rigid STA movement: RSTAM). This study proposes to assess RSTAM on the thigh, shank, and knee joint and to observe possible features between subjects. Nineteen subjects with knee arthroplasty were asked to walk on a treadmill while a biplane fluoroscopic system (X-rays) and a stereophotogrammetric system (skin markers) recorded their knee movement. The RSTAM was defined as the rigid movement of the cluster of skin markers relative to the prosthesis. The results showed that RSTAM amplitude represents approximately 80-100% of the STA. The vertical axis of the anatomical frame of the femur was influenced the most by RSTAM. Combined with tibial error, internal/external rotation angle and distraction-compression were the knee kinematics parameters most affected by RSTAM during the gait cycle, with average rms values of 3.8° and 11.1 mm. This study highlighted higher RSTAM during the swing phase particularly in the thigh segment and suggests new features for RSTAM such as the particular shape of some RSTAM waveforms and the absence of RSTAM in certain kinematics during the gait phases. The comparison of coefficient of multiple correlations showed some similarities of RSTAM between subjects, while some correlations were found with gait speed and BMI. These new insights could potentially allow the development of new methods of compensation to avoid STA.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

IMPORTANCE: There are limited prospective, controlled data evaluating survival in patients receiving early surgery vs medical therapy for prosthetic valve endocarditis (PVE). OBJECTIVE: To determine the in-hospital and 1-year mortality in patients with PVE who undergo valve replacement during index hospitalization compared with patients who receive medical therapy alone, after controlling for survival and treatment selection bias. DESIGN, SETTING, AND PARTICIPANTS: Participants were enrolled between June 2000 and December 2006 in the International Collaboration on Endocarditis-Prospective Cohort Study (ICE-PCS), a prospective, multinational, observational cohort of patients with infective endocarditis. Patients hospitalized with definite right- or left-sided PVE were included in the analysis. We evaluated the effect of treatment assignment on mortality, after adjusting for biases using a Cox proportional hazards model that included inverse probability of treatment weighting and surgery as a time-dependent covariate. The cohort was stratified by probability (propensity) for surgery, and outcomes were compared between the treatment groups within each stratum. INTERVENTIONS: Valve replacement during index hospitalization (early surgery) vs medical therapy. MAIN OUTCOMES AND MEASURES: In-hospital and 1-year mortality. RESULTS: Of the 1025 patients with PVE, 490 patients (47.8%) underwent early surgery and 535 individuals (52.2%) received medical therapy alone. Compared with medical therapy, early surgery was associated with lower in-hospital mortality in the unadjusted analysis and after controlling for treatment selection bias (in-hospital mortality: hazard ratio [HR], 0.44 [95% CI, 0.38-0.52] and lower 1-year mortality: HR, 0.57 [95% CI, 0.49-0.67]). The lower mortality associated with surgery did not persist after adjustment for survivor bias (in-hospital mortality: HR, 0.90 [95% CI, 0.76-1.07] and 1-year mortality: HR, 1.04 [95% CI, 0.89-1.23]). Subgroup analysis indicated a lower in-hospital mortality with early surgery in the highest surgical propensity quintile (21.2% vs 37.5%; P = .03). At 1-year follow-up, the reduced mortality with surgery was observed in the fourth (24.8% vs 42.9%; P = .007) and fifth (27.9% vs 50.0%; P = .007) quintiles of surgical propensity. CONCLUSIONS AND RELEVANCE: Prosthetic valve endocarditis remains associated with a high 1-year mortality rate. After adjustment for differences in clinical characteristics and survival bias, early valve replacement was not associated with lower mortality compared with medical therapy in the overall cohort. Further studies are needed to define the effect and timing of surgery in patients with PVE who have indications for surgery.