211 resultados para Pulse Measurement
Resumo:
Combining bacterial bioreporters with microfluidics systems holds great promise for in-field detection of chemical or toxicity targets. Recently we showed how Escherichia coli cells engineered to produce a variant of green fluorescent protein after contact to arsenite and arsenate can be encapsulated in agarose beads and incorporated into a microfluidic chip to create a device for in-field detection of arsenic, a contaminant of well known toxicity and carcinogenicity in potable water both in industrialized and developing countries. Cell-beads stored in the microfluidics chip at -20°C retained inducibility up to one month and we were able to reproducibly discriminate concentrations of 10 and 50 μg arsenite per L (the drinking water standards for European countries and the United States, and for the developing countries, respectively) from the blank in less than 200 minutes. We discuss here the reasons for decreasing bioreporter signal development upon increased storage of cell beads but also show how this decrease can be reduced, leading to a faster detection and a longer lifetime of the device.
Resumo:
PURPOSE: Intravenous (i.v.) pulse of corticosteroids has been used to treat severe eye inflammation from different origins. Whether such large doses result in vitreous levels that differ either in magnitude or duration from more conventional corticotherapy remain unsolved issues. The authors therefore determined levels of methylprednisolone hemisuccinate and methylprednisolone in the vitreous and serum of patients at different times after a single i.v. perfusion of methylprednisolone hemisuccinate. METHODS: Fifty patients scheduled for a first vitrectomy received an i.v. injection of 500 mg hemisuccinate methylprednisolone at different times before surgery (from 15-24 hours). Patients were divided into two groups: those with (n = 21) and without (n = 29) retinal detachment (RD). Pure vitreous samples were analyzed by high-pressure liquid chromatography. RESULTS: Both the ester and the nonester methylprednisolone forms were sampled in the vitreous, showing a slower rate of hydrolysis compared to the serum. On average, the highest concentration of total methylprednisolone in the vitreous was found at 2.5 hours and rapidly decreased for the group of patients with RD. In the group of patients without RD, the highest concentration was reached at 6 hours and then slowly decreased. The antiinflammatory potency in the nondetached retina eyes was approximately 500 times more than in the physiologic vitreous, but despite the route of administration (i.v. or oral), only 1/10 of the corticosteroid serum concentration was measured in the vitreous. CONCLUSION: High concentration of methylprednisolone is achieved by i.v. pulse therapy without changing the kinetic of entry in the vitreous of nondetached retina eyes when compared to conventional oral corticotherapy. Hydrolysis occurs in the vitreous resulting in high rate of active form. Pulse therapy could be considered in cases of severe ocular inflammation involving the posterior segment of the eye.
Resumo:
Postmortem human chorionic gonadotrophin (HCG) blood assay can confirm postmortem diagnosis of pregnancy or document situations in which HCG levels are elevated. In some cases, however, blood sampling is not possible at autopsy. In this study, HCG was quantified by enzyme-linked fluorescent assay (ELFA) in the bile (n = 5), vitreous humor (n = 4), and postmortem blood (n = 4) of five pregnant women. There were no false negatives in the pregnant subjects (n = 5) or false positives in controls (n = 34), enabling this test to be recommended for routine use in forensic contexts in which the detection of elevated HCG levels could be of interest.
Resumo:
OBJECTIVES: To explore the association of short-term exposure to particulate matter with aerodynamic diameters less than 10 μm (PM10) with pulse pressure, SBP, and DBP taking outdoor temperature into account in two large population-based studies in Switzerland. METHODS: We used data from the Bus Santé study including 5605 adults in Geneva and the CoLaus study including 6183 adults in Lausanne. PM10 and meteorological data were measured from fixed monitoring stations. We analyzed the association of short-term exposure to PM10 (on the day of examination visit and up to 7 days before) with pulse pressure, SBP, and DBP by linear regression, controlling for potential confounders and effect modifiers. RESULTS: Average PM10 levels were 22.4 μg/m in Geneva and 31.7 μg/m in Lausanne. In adjusted models, for each 10 μg/m increase in 7-day PM10 average, pulse pressure and SBP increased by 0.583 (95% confidence interval, 0.296-0.870) mmHg and 0.490 (0.056-0.925) mmHg in Geneva, and 0.183 (0.017-0.348) mmHg and 0.036 (0.042-0.561) mmHg in Lausanne, respectively. Stronger associations of pulse pressure and SBP with PM10 were observed when outdoor temperature was above 5°C. CONCLUSION: Positive associations of pulse pressure and SBP with short-term exposure to PM10 were found and replicated in the Swiss adult population. Our results suggest that even low levels of air pollution may substantially impact cardiovascular risk in the general population.
Resumo:
BACKGROUND: Chronic kidney disease (CKD) accelerates vascular stiffening related to age. Arterial stiffness may be evaluated measuring the carotid-femoral pulse wave velocity (PWV) or more simply, as recommended by KDOQI, monitoring pulse pressure (PP). Both correlate to survival and incidence of cardiovascular disease. PWV can also be estimated on the brachial artery using a Mobil-O-Graph; a non-operator dependent automatic device. The aim was to analyse whether, in a dialysis population, PWV obtained by Mobil-O-Graph (MogPWV) is more sensitive for vascular aging than PP. METHODS: A cohort of 143 patients from 4 dialysis units has been followed measuring MogPWV and PP every 3 to 6 months and compared to a control group with the same risk factors but an eGFR > 30 ml/min. RESULTS: MogPWV contrarily to PP did discriminate the dialysis population from the control group. The mean difference translated in age between the two populations was 8.4 years. The increase in MogPWV, as a function of age, was more rapid in the dialysis group. 13.3% of the dialysis patients but only 3.0% of the control group were outliers for MogPWV. The mortality rate (16 out of 143) was similar in outliers and inliers (7.4 and 8.0%/year). Stratifying patients according to MogPWV, a significant difference in survival was seen. A high parathormone (PTH) and to be dialysed for a hypertensive nephropathy were associated to a higher baseline MogPWV. CONCLUSIONS: Assessing PWV on the brachial artery using a Mobil-O-Graph is a valid and simple alternative, which, in the dialysis population, is more sensitive for vascular aging than PP. As demonstrated in previous studies PWV correlates to mortality. Among specific CKD risk factors only PTH is associated with a higher baseline PWV. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02327962.
Resumo:
BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
Resumo:
OBJECTIVE: In contrast to conventional (CONV) neuromuscular electrical stimulation (NMES), the use of "wide-pulse, high-frequencies" (WPHF) can generate higher forces than expected by the direct activation of motor axons alone. We aimed at investigating the occurrence, magnitude, variability and underlying neuromuscular mechanisms of these "Extra Forces" (EF). METHODS: Electrically-evoked isometric plantar flexion force was recorded in 42 healthy subjects. Additionally, twitch potentiation, H-reflex and M-wave responses were assessed in 13 participants. CONV (25Hz, 0.05ms) and WPHF (100Hz, 1ms) NMES consisted of five stimulation trains (20s on-90s off). RESULTS: K-means clustering analysis disclosed a responder rate of almost 60%. Within this group of responders, force significantly increased from 4% to 16% of the maximal voluntary contraction force and H-reflexes were depressed after WPHF NMES. In contrast, non-responders showed neither EF nor H-reflex depression. Twitch potentiation and resting EMG data were similar between groups. Interestingly, a large inter- and intrasubject variability of EF was observed. CONCLUSION: The responder percentage was overestimated in previous studies. SIGNIFICANCE: This study proposes a novel methodological framework for unraveling the neurophysiological mechanisms involved in EF and provides further evidence for a central contribution to EF in responders.
Resumo:
OBJECTIVE: Systolic blood pressure (BP) has been associated with urinary caffeine and its metabolites such as paraxanthine and theophylline. Caffeine and caffeine metabolites could influence arterial pulse pressure (PP) via sympathomimetic effects, smooth muscle relaxation, and phosphodiesterase inhibition. The purpose of this analysis was to explore the association of ambulatory PP with urinary caffeine and its related metabolites in a large population-based sample. DESIGN AND METHOD: Families were randomly selected from the general population of three Swiss cities (2009-2013). Ambulatory BP monitoring was conducted using validated Diasys Integra devices. PP was defined as the difference between the systolic and diastolic ambulatory BP. Urinary caffeine, paraxanthine, theophylline, and theobromine excretions were measured in 24 h urine using ultra-high performance liquid chromatography tandem mass spectrometry. Urinary excretions were log-transformed to satisfy regression assumptions. We used linear mixed models to explore the associations of urinary caffeine and caffeine metabolite excretions with 24-hour, day- and night-time PP while adjusting for major confounders. RESULTS: The 836 participants (48.9% men) included in this analysis had mean (±SD) age of 47.8 (±17.5), and mean 24-hour systolic and diastolic BP of 120.1 mmHg (±13.9) and 78.0 (±8.6). Except theobromine, log transformed urinary caffeine and caffeine metabolite excretions were associated negatively with 24-hour, daytime and night-time ambulatory PP. 24-hour, daytime, and night-time ambulatory PP decreased by -0.804 mmHg (SE, 0.209), -0.749 (0.215), and -0.968 (0.243) (all P values <0.005), for each doubling excretion of caffeine. Strong negative associations with night-time ambulatory PP were observed for paraxanthine and theophylline.(Figure is included in full-text article.) CONCLUSIONS: : The negative associations of PP with caffeine, paraxanthine, and theophylline excretions suggest that caffeine and its metabolites do lower BP, possibly by modifying arterial stiffness.
Resumo:
Issue ownership means that some parties are considered by the public at large as being more able to deal with, or more attentive to, certain issues. The theory has been used to explain both party behaviour - parties are expected to focus on owned issues - and voter behaviour - when a voter considers a party to own an issue, this affects the odds of voting for that party. The purpose of this article is, first, to provide a look backward at the existing research through a literature review of the studies that were conducted in the past decade-and-a-half. Secondly, it takes stock of the current conceptualisation and argues that issue ownership is a multidimensional concept. Thereafter the article discusses how this multidimensionality affects both the role of issue ownership in voter and in party behaviour. Finally, the article outlines a number of shortcomings of the extant literature and discusses potential avenues for future research.
Resumo:
Reaching a consensus in terms of interchangeability and utility (i.e., disease detection/monitoring) of a medical device is the eventual aim of repeatability and agreement studies. The aim of the tolerance and relative utility indices described in this report is to provide a methodology to compare change in clinical measurement noise between different populations (repeatability) or measurement methods (agreement), so as to highlight problematic areas. No longitudinal data are required to calculate these indices. Both indices establish a metric of least to most effected across all parameters to facilitate comparison. If validated, these indices may prove useful tools when combining reports and forming the consensus required in the validation process for software updates and new medical devices.