299 resultados para Posteroanterior motion test
Resumo:
Early detection of neural-tude defects is possible by determining Alpha-fetoprotein (AFP) in maternal serum. 16'685 pregnant women were observed. Three methods for the determination of the "normal" range are compared. The first one, already used in similar studies, makes use of a constant multiple of the median. The other two ones make use of robust estimates of location and scale. Their comparison shows the interest of the robust methods to reduce the interlaboratory variability.
Resumo:
Le but de cette étude est de répondre aux 3 questions suivantes: - 1) Le test de MAST est-il applicable, dans sa traduction française, à la population d'un service de médecine interne d'un hôpital universitaire en Suisse romande ? - 2) Le test de MAST apporte-t-il des résultats concordants avec le diagnostic clinique d'une part, et avec les résultats tirés de la littérature d'autre part ? - 3) De quelles façons peut-on définir et choisir deux valeurs critiques du test afin d'optimaliser l'utilisation du test de MAST dans l'étude comparative projetée ? ANNEXE: Traduction littérale en langue française du : "Michigan Alcoholism Screening Test" (MAST); etc.
Resumo:
Several methods and algorithms have recently been proposed that allow for the systematic evaluation of simple neuron models from intracellular or extracellular recordings. Models built in this way generate good quantitative predictions of the future activity of neurons under temporally structured current injection. It is, however, difficult to compare the advantages of various models and algorithms since each model is designed for a different set of data. Here, we report about one of the first attempts to establish a benchmark test that permits a systematic comparison of methods and performances in predicting the activity of rat cortical pyramidal neurons. We present early submissions to the benchmark test and discuss implications for the design of future tests and simple neurons models
Resumo:
Cardiovascular risk assessment might be improved with the addition of emerging, new tests derived from atherosclerosis imaging, laboratory tests or functional tests. This article reviews relative risk, odds ratios, receiver-operating curves, posttest risk calculations based on likelihood ratios, the net reclassification improvement and integrated discrimination. This serves to determine whether a new test has an added clinical value on top of conventional risk testing and how this can be verified statistically. Two clinically meaningful examples serve to illustrate novel approaches. This work serves as a review and basic work for the development of new guidelines on cardiovascular risk prediction, taking into account emerging tests, to be proposed by members of the 'Taskforce on Vascular Risk Prediction' under the auspices of the Working Group 'Swiss Atherosclerosis' of the Swiss Society of Cardiology in the future.
Resumo:
PURPOSE: To evaluate the feasibility of intravoxel incoherent motion (IVIM) perfusion measurements in the brain with currently available imaging systems. MATERIALS AND METHODS: We acquired high in-plane resolution (1.2 × 1.2 mm(2) ) diffusion-weighted images with 16 different values of b ranging from 0 to 900 s/mm(2) , in three orthogonal directions, on 3T systems with a 32-multichannel receiver head coil. IVIM perfusion maps were extracted by fitting a double exponential model of signal amplitude decay. Regions of interest were drawn in pathological and control regions, where IVIM perfusion parameters were compared to the corresponding dynamic susceptibility contrast (DSC) parameters. RESULTS: Hyperperfusion was found in the nonnecrotic or cystic part of two histologically proven glioblastoma multiforme and in two histologically proven glioma WHO grade III, as well as in a brain metastasis of lung adenocarcinoma, in a large meningioma, and in a case of ictal hyperperfusion. A monoexponential decay was found in a territory of acute ischemia, as well as in the necrotic part of a glioblastoma. The IVIM perfusion fraction f correlated well with DSC CBV. CONCLUSION: Our initial report suggests that high-resolution brain perfusion imaging is feasible with IVIM in the current clinical setting. J. Magn. Reson. Imaging 2014;39:624-632. © 2013 Wiley Periodicals, Inc.
Resumo:
Background: Detection rates for adenoma and early colorectal cancer (CRC) are unsatisfactory due to low compliance towards invasive screening procedures such as colonoscopy. There is a large unmet screening need calling for an accurate, non-invasive and cost-effective test to screen for early neoplastic and pre-neoplastic lesions. Our goal is to identify effective biomarker combinations to develop a screening test aimed at detecting precancerous lesions and early CRC stages, based on a multigene assay performed on peripheral blood mononuclear cells (PBMC).Methods: A pilot study was conducted on 92 subjects. Colonoscopy revealed 21 CRC, 30 adenomas larger than 1 cm and 41 healthy controls. A panel of 103 biomarkers was selected by two approaches: a candidate gene approach based on literature review and whole transcriptome analysis of a subset of this cohort by Illumina TAG profiling. Blood samples were taken from each patient and PBMC purified. Total RNA was extracted and the 103 biomarkers were tested by multiplex RT-qPCR on the cohort. Different univariate and multivariate statistical methods were applied on the PCR data and 60 biomarkers, with significant p-value (< 0.01) for most of the methods, were selected.Results: The 60 biomarkers are involved in several different biological functions, such as cell adhesion, cell motility, cell signaling, cell proliferation, development and cancer. Two distinct molecular signatures derived from the biomarker combinations were established based on penalized logistic regression to separate patients without lesion from those with CRC or adenoma. These signatures were validated using bootstrapping method, leading to a separation of patients without lesion from those with CRC (Se 67%, Sp 93%, AUC 0.87) and from those with adenoma larger than 1cm (Se 63%, Sp 83%, AUC 0.77). In addition, the organ and disease specificity of these signatures was confirmed by means of patients with other cancer types and inflammatory bowel diseases.Conclusions: The two defined biomarker combinations effectively detect the presence of CRC and adenomas larger than 1 cm with high sensitivity and specificity. A prospective, multicentric, pivotal study is underway in order to validate these results in a larger cohort.
Resumo:
OBJECTIVE: Accuracy studies of Patient Safety Indicators (PSIs) are critical but limited by the large samples required due to low occurrence of most events. We tested a sampling design based on test results (verification-biased sampling [VBS]) that minimizes the number of subjects to be verified. METHODS: We considered 3 real PSIs, whose rates were calculated using 3 years of discharge data from a university hospital and a hypothetical screen of very rare events. Sample size estimates, based on the expected sensitivity and precision, were compared across 4 study designs: random and VBS, with and without constraints on the size of the population to be screened. RESULTS: Over sensitivities ranging from 0.3 to 0.7 and PSI prevalence levels ranging from 0.02 to 0.2, the optimal VBS strategy makes it possible to reduce sample size by up to 60% in comparison with simple random sampling. For PSI prevalence levels below 1%, the minimal sample size required was still over 5000. CONCLUSIONS: Verification-biased sampling permits substantial savings in the required sample size for PSI validation studies. However, sample sizes still need to be very large for many of the rarer PSIs.
Resumo:
Relaxation rates provide important information about tissue microstructure. Multi-parameter mapping (MPM) estimates multiple relaxation parameters from multi-echo FLASH acquisitions with different basic contrasts, i.e., proton density (PD), T1 or magnetization transfer (MT) weighting. Motion can particularly affect maps of the apparent transverse relaxation rate R2(*), which are derived from the signal of PD-weighted images acquired at different echo times. To address the motion artifacts, we introduce ESTATICS, which robustly estimates R2(*) from images even when acquired with different basic contrasts. ESTATICS extends the fitted signal model to account for inherent contrast differences in the PDw, T1w and MTw images. The fit was implemented as a conventional ordinary least squares optimization and as a robust fit with a small or large confidence interval. These three different implementations of ESTATICS were tested on data affected by severe motion artifacts and data with no prominent motion artifacts as determined by visual assessment or fast optical motion tracking. ESTATICS improved the quality of the R2(*) maps and reduced the coefficient of variation for both types of data-with average reductions of 30% when severe motion artifacts were present. ESTATICS can be applied to any protocol comprised of multiple 2D/3D multi-echo FLASH acquisitions as used in the general research and clinical setting.
Resumo:
The nose is the anatomical site usually recommended for methicillin-resistant Staphylococcus aureus (MRSA) screening. Other sites are also recommended, but are more controversial. We showed that the sensitivities of MRSA detection from nasal swabs alone were 48% and 62% by culture or by rapid PCR test, respectively. These percentages increased to 79% and 92% with the addition of groin swabs, and to 96% and 99% with the addition of groin and throat swabs. In conclusion, neither by culture nor by rapid PCR test is nose sampling alone sufficient for MRSA detection. Additional anatomical sites should include at least the groin and throat.
Resumo:
Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively--or optionally retrospectively--correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity≥92%, specificity>98%). Motion detection triggered an additional image volume acquisition with b=0 s/mm2 which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed.
Resumo:
Aim To evaluate the effects of using distinct alternative sets of climatic predictor variables on the performance, spatial predictions and future projections of species distribution models (SDMs) for rare plants in an arid environment. . Location Atacama and Peruvian Deserts, South America (18º30'S - 31º30'S, 0 - 3 000 m) Methods We modelled the present and future potential distributions of 13 species of Heliotropium sect. Cochranea, a plant group with a centre of diversity in the Atacama Desert. We developed and applied a sequential procedure, starting from climate monthly variables, to derive six alternative sets of climatic predictor variables. We used them to fit models with eight modelling techniques within an ensemble forecasting framework, and derived climate change projections for each of them. We evaluated the effects of using these alternative sets of predictor variables on performance, spatial predictions and projections of SDMs using Generalised Linear Mixed Models (GLMM). Results The use of distinct sets of climatic predictor variables did not have a significant effect on overall metrics of model performance, but had significant effects on present and future spatial predictions. Main conclusion Using different sets of climatic predictors can yield the same model fits but different spatial predictions of current and future species distributions. This represents a new form of uncertainty in model-based estimates of extinction risk that may need to be better acknowledged and quantified in future SDM studies.
Resumo:
The purpose of this study was to investigate the impact of in-plane coronary artery motion on coronary magnetic resonance angiography (MRA) and coronary MR vessel wall imaging. Free-breathing, navigator-gated, 3D-segmented k-space turbo field echo ((TFE)/echo-planar imaging (EPI)) coronary MRA and 2D fast spin-echo coronary vessel wall imaging of the right coronary artery (RCA) were performed in 15 healthy adult subjects. Images were acquired at two different diastolic time periods in each subject: 1) during a subject-specific diastasis period (in-plane velocity <4 cm/second) identified from analysis of in-plane coronary artery motion, and 2) using a diastolic trigger delay based on a previously implemented heart-rate-dependent empirical formula. RCA vessel wall imaging was only feasible with subject-specific middiastolic acquisition, while the coronary wall could not be identified with the heart-rate-dependent formula. For coronary MRA, RCA border definition was improved by 13% (P < 0.001) with the use of subject-specific trigger delay (vs. heart-rate-dependent delay). Subject-specific middiastolic image acquisition improves 3D TFE/EPI coronary MRA, and is critical for RCA vessel wall imaging.
Resumo:
OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.