253 resultados para Following behaviour


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Clinical practice does not always reflect best practice and evidence, partly because of unconscious acts of omission, information overload, or inaccessible information. Reminders may help clinicians overcome these problems by prompting the doctor to recall information that they already know or would be expected to know and by providing information or guidance in a more accessible and relevant format, at a particularly appropriate time. OBJECTIVES: To evaluate the effects of reminders automatically generated through a computerized system and delivered on paper to healthcare professionals on processes of care (related to healthcare professionals' practice) and outcomes of care (related to patients' health condition). SEARCH METHODS: For this update the EPOC Trials Search Co-ordinator searched the following databases between June 11-19, 2012: The Cochrane Central Register of Controlled Trials (CENTRAL) and Cochrane Library (Economics, Methods, and Health Technology Assessment sections), Issue 6, 2012; MEDLINE, OVID (1946- ), Daily Update, and In-process; EMBASE, Ovid (1947- ); CINAHL, EbscoHost (1980- ); EPOC Specialised Register, Reference Manager, and INSPEC, Engineering Village. The authors reviewed reference lists of related reviews and studies.  SELECTION CRITERIA: We included individual or cluster-randomized controlled trials (RCTs) and non-randomized controlled trials (NRCTs) that evaluated the impact of computer-generated reminders delivered on paper to healthcare professionals on processes and/or outcomes of care. DATA COLLECTION AND ANALYSIS: Review authors working in pairs independently screened studies for eligibility and abstracted data. We contacted authors to obtain important missing information for studies that were published within the last 10 years. For each study, we extracted the primary outcome when it was defined or calculated the median effect size across all reported outcomes. We then calculated the median absolute improvement and interquartile range (IQR) in process adherence across included studies using the primary outcome or median outcome as representative outcome. MAIN RESULTS: In the 32 included studies, computer-generated reminders delivered on paper to healthcare professionals achieved moderate improvement in professional practices, with a median improvement of processes of care of 7.0% (IQR: 3.9% to 16.4%). Implementing reminders alone improved care by 11.2% (IQR 6.5% to 19.6%) compared with usual care, while implementing reminders in addition to another intervention improved care by 4.0% only (IQR 3.0% to 6.0%) compared with the other intervention. The quality of evidence for these comparisons was rated as moderate according to the GRADE approach. Two reminder features were associated with larger effect sizes: providing space on the reminder for provider to enter a response (median 13.7% versus 4.3% for no response, P value = 0.01) and providing an explanation of the content or advice on the reminder (median 12.0% versus 4.2% for no explanation, P value = 0.02). Median improvement in processes of care also differed according to the behaviour the reminder targeted: for instance, reminders to vaccinate improved processes of care by 13.1% (IQR 12.2% to 20.7%) compared with other targeted behaviours. In the only study that had sufficient power to detect a clinically significant effect on outcomes of care, reminders were not associated with significant improvements. AUTHORS' CONCLUSIONS: There is moderate quality evidence that computer-generated reminders delivered on paper to healthcare professionals achieve moderate improvement in process of care. Two characteristics emerged as significant predictors of improvement: providing space on the reminder for a response from the clinician and providing an explanation of the reminder's content or advice. The heterogeneity of the reminder interventions included in this review also suggests that reminders can improve care in various settings under various conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Measurements and simulations were performed to assess workers' exposure to solvent vapors and aerosols during the waterproofing of a tiled surface. This investigation followed two recent incidents in the same company where workers experienced acute respiratory illness after spraying a stain-repellent resin containing fluorinated polymers on stone-tiled walls and floors. Because the waterproofing activity had been done for years at the tile company without encountering any exposure problems prior to these cases, it was strongly suspected that the incidents were linked to a recent change in the composition of the coating mixture. Experimental measurements and simulations indicated that the emission rate of particles smaller than 10 microm may be estimated at 0.66 mg/sec (SD 0.10) for the old resin and at 0.37 mg/sec (SD 0.04) for the new one. The measurement of the solvent emission rate from surfaces coated with the two resins indicated that shortly after spraying, the emission was in the range of 18 to 20 mg/sec x m2 and was similar for both products. Solvent and overspray emission rates were introduced in a two-zone compartment model. The results obtained in the near-field indicate significant exposure to overspray mist (7 and 34 mg/m3 for new resin) and solvent vapors (80 to 350 ppm for the new resin). It was also shown that the introduction of the new resin tended to significantly decrease the levels of solvents and particulates in the workers' breathing zone. These results strongly suggest that cases of acute respiratory illness are related to the specific toxicity of the fluorinated polymer itself. The fact that the same polymer is used in various commercial products raises concern regarding other possible occupational and domestic exposures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Surgical tumor removal is often the treatment of choice in patients with head and neck squamous cell carcinoma. Depending on the extent of tumor resection, large defects are often produced in the individual head and neck regions, necessitating reconstructive surgery to avoid further functional impairment. In principle, this decision depends on the size and location of the defect, the aesthetic importance of the region and the functional significance of the area to be replaced. Reconstructive free flap procedures in patients who have undergone radiotherapy or exhibit vessel depletion in the neck due to multiple previous surgical interventions are particularly challenging. In order to ensure the best possible outcomes of surgical oncology therapies under difficult circumstances, this paper discusses the important factors and variables that can increase the success rate of microvascular grafts in irradiated or multiply resected patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Concerns have been raised about the use of topical retinoids since the publication of isolated cases of characteristic retinoid embryopathy, originally described after oral use. A collaborative study of the European Network of Teratology Information Services was carried out to evaluate the rate of congenital malformations following first-trimester topical retinoid exposure. A population of 235 exposed pregnant women was compared with 444 controls. No significant differences were observed between groups with regard to the rates of spontaneous abortion (odds ratio [95% confidence interval], 1.5 [0.8-2.7]), minor birth defects (1.3 [0.4-3.7]), and major birth defects (1.8 [0.6-5.4]). No child showed features of retinoid embryopathy. The rate of elective termination in the exposed group was increased 3-fold (3.4 [1.5-7.8]). In conclusion, these results do not suggest an increased risk of retinoid embryopathy. However, according to current knowledge, topical retinoids cannot be advised for use during pregnancy because their risk/benefit ratio remains questionable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study aimed to determine adjustments in spring-mass model characteristics, plantar loading and foot mobility induced by an exhaustive run. DESIGN: Within-participants repeated measures. METHODS: Eleven highly-trained adolescent middle-distance runners ran to exhaustion on a treadmill at a constant velocity corresponding to 95% of velocity associated with VO₂max (17.8 ± 1.4 kmh(-1), time to exhaustion=8.8 ± 3.4 min). Contact time obtained from plantar pressure sensors was used to estimate spring-mass model characteristics, which were recorded (during 30 s) 1 min after the start and prior to exhaustion using pressure insoles. Foot mobility magnitude (a composite measure of vertical and medial-lateral mobility of the midfoot) was measured before and after the run. RESULTS: Mean contact area (foot to ground), contact time, peak vertical ground reaction force, centre of mass vertical displacement and leg compression increased significantly with fatigue, while flight time, leg stiffness and mean pressure decreased. Leg stiffness decreased because leg compression increased to a larger extent than peak vertical ground reaction forces. Step length, step frequency and foot mobility magnitude did not change at exhaustion. CONCLUSIONS: The stride pattern of adolescents when running on a treadmill at high constant velocity deteriorates near exhaustion, as evidenced by impaired leg-spring behaviour (leg stiffness) and altered plantar loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 29-year-old pregnant woman noted acute visual loss following emergent Caesarean section complicated by excessive uterine bleeding. Postoperative visual acuity was count fingers in both eyes. Funduscopic changes were consistent with a diagnosis of anaemia-associated ischaemic optic neuropathy and retinopathy. One month later, because of persistent anaemia and poor visual recovery, blood transfusion was given. Following transfusion, the patient's vision improved over the next 6 months. In an otherwise healthy patient, visual loss associated with postoperative blood loss may still be partially reversible with correction of the anaemia, even after a delayed period of time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports a series of experiments on patient JB, a man with memory difficulties following damage to the left frontal lobe. The primary characteristic of JB's recognition memory impairment is a high level of false recognition together with a normal hit rate. The hypothesis that JB's false recognition reflects an over-reliance on familiarity is considered, but discounted on the basis that the false alarm rate is not affected by increasing the similarity between distracters and targets, and remains high when nonword stimuli are used. It is suggested, instead, that JB relies on a poorly focused memory description, which lacks item-specific detail but contains more general, low-level properties of the target items-these properties being held by many distracter items as well. This deficit is considered to arise because of damage to frontally mediated control processes involved in the selection of elements for memory encoding. An encoding deficit is supported by the fact that JB's false recognition is significantly reduced by orienting instructions, and is eliminated when his remote memory is subjected to recognition testing. In contrast, it is shown that manipulations at the level of retrieval (e.g. restricting the number of "old" responses) have little effect on his false recognition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Following elective orthopaedic surgery or the treatment of a fracture, patients are temporarily unable to drive. This loss of independence may have serious social and economic consequences for the patient. It is therefore essential to know when it is safe to permit such patients to return to driving. This article, based upon a review of the current literature, proposes recommendations of the time period after which patients may safely return to driving. Practical decisions are made based upon the type of surgical intervention or fracture. Swiss legislation is equally approached so as to better define the decision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Delta(9)-Tetrahydrocannabinol (THC) is frequently found in the blood of drivers suspected of driving under the influence of cannabis or involved in traffic crashes. The present study used a double-blind crossover design to compare the effects of medium (16.5 mg THC) and high doses (45.7 mg THC) of hemp milk decoctions or of a medium dose of dronabinol (20 mg synthetic THC, Marinol on several skills required for safe driving. Forensic interpretation of cannabinoids blood concentrations were attempted using the models proposed by Daldrup (cannabis influencing factor or CIF) and Huestis and coworkers. First, the time concentration-profiles of THC, 11-hydroxy-Delta(9)-tetrahydrocannabinol (11-OH-THC) (active metabolite of THC), and 11-nor-9-carboxy-Delta(9)-tetrahydrocannabinol (THCCOOH) in whole blood were determined by gas chromatography-mass spectrometry-negative ion chemical ionization. Compared to smoking studies, relatively low concentrations were measured in blood. The highest mean THC concentration (8.4 ng/mL) was achieved 1 h after ingestion of the strongest decoction. Mean maximum 11-OH-THC level (12.3 ng/mL) slightly exceeded that of THC. THCCOOH reached its highest mean concentration (66.2 ng/mL) 2.5-5.5 h after intake. Individual blood levels showed considerable intersubject variability. The willingness to drive was influenced by the importance of the requested task. Under significant cannabinoids influence, the participants refused to drive when they were asked whether they would agree to accomplish several unimportant tasks, (e.g., driving a friend to a party). Most of the participants reported a significant feeling of intoxication and did not appreciate the effects, notably those felt after drinking the strongest decoction. Road sign and tracking testing revealed obvious and statistically significant differences between placebo and treatments. A marked impairment was detected after ingestion of the strongest decoction. A CIF value, which relies on the molar ratio of main active to inactive cannabinoids, greater than 10 was found to correlate with a strong feeling of intoxication. It also matched with a significant decrease in the willingness to drive, and it matched also with a significant impairment in tracking performances. The mathematic model II proposed by Huestis et al. (1992) provided at best a rough estimate of the time of oral administration with 27% of actual values being out of range of the 95% confidence interval. The sum of THC and 11-OH-THC blood concentrations provided a better estimate of impairment than THC alone. This controlled clinical study points out the negative influence on fitness to drive after medium or high dose oral THC or dronabinol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A very long half-life of paroxetine (195 h instead of the usual value of around 16 h) was measured after an overdose with 2 g paroxetine and 1 g clorazepate in a patient who was an extensive cytochrome P4502D6 metabolizer. The patient recovered well without any clinically significant complications. A consequence of the close monitoring of paroxetine levels in this patient was that it was decided not to reintroduce any other antidepressant despite her suicide attempt, until normal levels of paroxetine had been reached, which took over 1 month.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mouse-human chimeric monoclonal antibodies (MAbs) of 3 different human IgG sub-classes directed against carcinoembryonic antigen (CEA) have been produced in SP-0 cells transfected with genomic chimeric DNA. F(ab')2 fragments were obtained by pepsin digestion of the purified chimeric MAbs of human IgG1, IgG2 and IgG4 sub-class and of parental mouse MAb IgG1. The 4 F(ab')2 fragments exhibit similar molecular weight by SDS-PAGE. They were labelled with 125I or 131I and high binding (80 to 87%) to purified unsolubilized CEA was observed. In vivo, double labelling experiments indicate that the longest biological half-life and the highest tumour-localization capacity is obtained with F(ab')2 from chimeric MAb of human IgG2 sub-class, whereas F(ab')2 from chimeric MAb IgG4 give very low values for these 2 parameters. F(ab')2 from chimeric MAb IgG1 and from parental mouse MAb yield intermediate results in vivo. Our findings should help to select the appropriate human IgG sub-class to produce chimeric or reshaped MAb F(ab')2 to be used for tumour detection by immunoscintigraphy and for radioimmunotherapy.