228 resultados para Document imaging system


Relevância:

30.00% 30.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Perfusion-cardiovascular magnetic resonance (CMR) is generally accepted as an alternative to SPECT to assess myocardial ischemia non-invasively. However its performance vs gated-SPECT and in sub-populations is not fully established. The goal was to compare in a multicenter setting the diagnostic performance of perfusion-CMR and gated-SPECT for the detection of CAD in various populations using conventional x-ray coronary angiography (CXA) as the standard of reference. METHODS: In 33 centers (in US and Europe) 533 patients, eligible for CXA or SPECT, were enrolled in this multivendor trial. SPECT and CXA were performed within 4 weeks before or after CMR in all patients. Prevalence of CAD in the sample was 49% and 515 patients received MR contrast medium. Drop-out rates for CMR and SPECT were 5.6% and 3.7%, respectively (ns). The study was powered for the primary endpoint of non-inferiority of CMR vs SPECT for both, sensitivity and specificity for the detection of CAD (using a single-threshold reading), the results for the primary endpoint were reported elsewhere. In this article secondary endpoints are presented, i.e. the diagnostic performance of CMR versus SPECT in subpopulations such as multi-vessel disease (MVD), in men, in women, and in patients without prior myocardial infarction (MI). For diagnostic performance assessment the area under the receiver-operator-characteristics-curve (AUC) was calculated. Readers were blinded versus clinical data, CXA, and imaging results. RESULTS: The diagnostic performance (= area under ROC = AUC) of CMR was superior to SPECT (p = 0.0004, n = 425) and to gated-SPECT (p = 0.018, n = 253). CMR performed better than SPECT in MVD (p = 0.003 vs all SPECT, p = 0.04 vs gated-SPECT), in men (p = 0.004, n = 313) and in women (p = 0.03, n = 112) as well as in the non-infarct patients (p = 0.005, n = 186 in 1-3 vessel disease and p = 0.015, n = 140 in MVD). CONCLUSION: In this large multicenter, multivendor study the diagnostic performance of perfusion-CMR to detect CAD was superior to perfusion SPECT in the entire population and in sub-groups. Perfusion-CMR can be recommended as an alternative for SPECT imaging. TRIAL REGISTRATION: ClinicalTrials.gov, Identifier: NCT00977093.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In vivo fetal magnetic resonance imaging provides aunique approach for the study of early human braindevelopment [1]. In utero cerebral morphometry couldpotentially be used as a marker of the cerebralmaturation and help to distinguish between normal andabnormal development in ambiguous situations. However,this quantitative approach is a major challenge becauseof the movement of the fetus inside the amniotic cavity,the poor spatial resolution provided by very fast MRIsequences and the partial volume effect. Extensiveefforts are made to deal with the reconstruction ofhigh-resolution 3D fetal volumes based on severalacquisitions with lower resolution [2,3,4]. Frameworkswere developed for the segmentation of specific regionsof the fetal brain such as posterior fossa, brainstem orgerminal matrix [5,6], or for the entire brain tissue[7,8], applying the Expectation-Maximization MarkovRandom Field (EM-MRF) framework. However, many of theseprevious works focused on the young fetus (i.e. before 24weeks) and use anatomical atlas priors to segment thedifferent tissue or regions. As most of the gyraldevelopment takes place after the 24th week, acomprehensive and clinically meaningful study of thefetal brain should not dismiss the third trimester ofgestation. To cope with the rapidly changing appearanceof the developing brain, some authors proposed a dynamicatlas [8]. To our opinion, this approach however faces arisk of circularity: each brain will be analyzed /deformed using the template of its biological age,potentially biasing the effective developmental delay.Here, we expand our previous work [9] to proposepost-processing pipeline without prior that allow acomprehensive set of morphometric measurement devoted toclinical application. Data set & Methods: Prenatal MRimaging was performed with a 1-T system (GE MedicalSystems, Milwaukee) using single shot fast spin echo(ssFSE) sequences (TR 7000 ms, TE 180 ms, FOV 40 x 40 cm,slice thickness 5.4mm, in plane spatial resolution1.09mm). For each fetus, 6 axial volumes shifted by 1 mmwere acquired under motherâeuro?s sedation (about 1min pervolume). First, each volume is segmentedsemi-automatically using region-growing algorithms toextract fetal brain from surrounding maternal tissues.Inhomogeneity intensity correction [10] and linearintensity normalization are then performed. Brain tissues(CSF, GM and WM) are then segmented based on thelow-resolution volumes as presented in [9]. Ahigh-resolution image with isotropic voxel size of 1.09mm is created as proposed in [2] and using B-splines forthe scattered data interpolation [11]. Basal gangliasegmentation is performed using a levet setimplementation on the high-resolution volume [12]. Theresulting white matter image is then binarized and givenas an input in FreeSurfer software(http://surfer.nmr.mgh.harvard.edu) to providetopologically accurate three-dimensional reconstructionsof the fetal brain according to the local intensitygradient. References: [1] Guibaud, Prenatal Diagnosis29(4) (2009). [2] Rousseau, Acad. Rad. 13(9), 2006. [3]Jiang, IEEE TMI 2007. [4] Warfield IADB, MICCAI 2009. [5]Claude, IEEE Trans. Bio. Eng. 51(4) 2004. [6] Habas,MICCAI 2008. [7] Bertelsen, ISMRM 2009. [8] Habas,Neuroimage 53(2) 2010. [9] Bach Cuadra, IADB, MICCAI2009. [10] Styner, IEEE TMI 19(39 (2000). [11] Lee, IEEETrans. Visual. And Comp. Graph. 3(3), 1997. [12] BachCuadra, ISMRM 2010.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neuropsychological and neuroimaging data suggest that the self-memory system can be fractionated into three functionally independent systems processing personal information at several levels of abstraction, including episodic memories of one's life (episodic autobiographical memory, EAM), semantic knowledge of facts about one's life (semantic autobiographical memory, SAM), and semantic knowledge of one's personality [conceptual self, (CS)]. Through the study of two developmental amnesic patients suffering of neonatal brain injuries, we explored how the different facets of the self-memory system develop when growing up with bilateral hippocampal atrophy. Neuropsychological evaluations showed that both of them suffered from dramatic episodic learning disability with no sense of recollection (Remember/Know procedure), whereas their semantic abilities differed, being completely preserved (Valentine) or not (Jocelyn). Magnetic resonance imaging, including quantitative volumetric measurements of the hippocampus and adjacent (entorhinal, perirhinal, and temporopolar) cortex, showed severe bilateral atrophy of the hippocampus in both patients, with additional atrophy of adjacent cortex in Jocelyn. Exploration of EAM and SAM according to lifetime periods covering the entire lifespan (TEMPAu task, Piolino et al., 2009) showed that both patients had marked impairments in EAM, as they lacked specificity, details and sense of recollection, whereas SAM was completely normal in Valentine, but impaired in Jocelyn. Finally, measures of patients' CS (Tennessee Self-Concept Scale, Fitts and Warren, 1996), checked by their mothers, were generally within normal range, but both patients showed a more positive self-concept than healthy controls. These two new cases support a modular account of the medial-temporal lobe with episodic memory and recollection depending on the hippocampus, and semantic memory and familiarity on adjacent cortices. Furthermore, they highlight developmental episodic and semantic functional independence within the self-memory system suggesting that SAM and CS may be acquired without episodic memories.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When exposed to parasites, hosts often mount energetically expensive immune responses, and this may alter resource allocation between competing life history traits including other components of the immune system. Here, we investigated whether a humoral immune challenge towards a vaccine reduces or enhances the cutaneous immune responses towards an injection of lipopolysaccharid (LPS, innate immunity) and phytohaemagglutinin (PHA, T-cell immunity) in nestling tawny owls in interaction with the degree of plumage melanin-based coloration. The humoral immune challenge enhanced the response to LPS similarly in differently coloured nestlings. In contrast, the same humoral immune challenge enhanced immune response to PHA in dark reddish melanic nestlings while reducing it in pale reddish melanic nestlings. Our results highlight that both antagonistic and synergistic interactions can take place among branches of immune system, and that the sign and magnitude of these interactions can vary with immune responses involved and the degree of melanin-based coloration.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: There is limited safety information on most drugs used during pregnancy. This is especially true for medication against tropical diseases because pharmacovigilance systems are not much developed in these settings. The aim of the present study was to demonstrate feasibility of using Health and Demographic Surveillance System (HDSS) as a platform to monitor drug safety in pregnancy. METHODS: Pregnant women with gestational age below 20 weeks were recruited from Reproductive and Child Health (RCH) clinics or from monthly house visits carried out for the HDSS. A structured questionnaire was used to interview pregnant women. Participants were followed on monthly basis to record any new drug used as well as pregnancy outcome. RESULTS: 1089 pregnant women were recruited; 994 (91.3%) completed the follow-up until delivery. 98% women reported to have taken at least one medication during pregnancy, mainly those used in antenatal programmes. Other most reported drugs were analgesics (24%), antibiotics (17%), and antimalarial (15%), excluding IPTp. Artemether-lumefantrine (AL) was the most used antimalarial for treating illness by nearly 3/4 compared to other groups of malaria drugs. Overall, antimalarial and antibiotic exposures in pregnancy were not significantly associated with adverse pregnancy outcome. Iron and folic acid supplementation were associated with decreased risk of miscarriage/stillbirth (OR 0.1; 0.08 - 0.3). CONCLUSION: Almost all women were exposed to medication during pregnancy. Exposure to iron and folic acid had a beneficial effect on pregnancy outcome. HDSS proved to be a useful platform to establish a reliable pharmacovigilance system in resource-limited countries. Widening drug safety information is essential to facilitate evidence based risk-benefit decision for treatment during pregnancy, a major challenge with newly marketed medicines.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Le présent travail a eu comme but la comparaison de la performance de deux méthodes d'imagerie diagnostique pour la détection de métastases hépatiques du mélanome uvéal : la tomographie d'émission par positons au F-18-fluorodésoxyglucose (TEP FDG) couplée à la tomodensitométrie (TDM) et l'imagerie par résonance magnétique (IRM). Dans cette étude rétrospective, nous avons analysé les données radiologiques de patients inclus dans une étude multicentrique randomisée de phase III de l'Uveal Melanoma Group of the European Organization for Research and Treatment of Cancer (EORTC). L'IRM s'est révélée nettement plus sensible que le FDG-PET/CT pour mettre en évidence les métastases hépatiques notamment de taille infra-centimétrique. Néanmoins, l'analyse des changements de l'accumulation du traceur métabolique par les métastases hépatiques au cours du traitement suggère la possibilité d'évaluer, de manière précoce, la réponse des métastases hépatiques à la chimiothérapie. Le nombre de cas étudiés est trop faible pour déterminer la précision et la valeur clinique d'une telle évaluation mais les résultats obtenus dans cette étude pilote justifient une étude plus étendue.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Differential X-ray phase-contrast tomography (DPCT) refers to a class of promising methods for reconstructing the X-ray refractive index distribution of materials that present weak X-ray absorption contrast. The tomographic projection data in DPCT, from which an estimate of the refractive index distribution is reconstructed, correspond to one-dimensional (1D) derivatives of the two-dimensional (2D) Radon transform of the refractive index distribution. There is an important need for the development of iterative image reconstruction methods for DPCT that can yield useful images from few-view projection data, thereby mitigating the long data-acquisition times and large radiation doses associated with use of analytic reconstruction methods. In this work, we analyze the numerical and statistical properties of two classes of discrete imaging models that form the basis for iterative image reconstruction in DPCT. We also investigate the use of one of the models with a modern image reconstruction algorithm for performing few-view image reconstruction of a tissue specimen.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: In order to provide a cost-effective tool to analyse pharmacogenetic markers in malaria treatment, DNA microarray technology was compared with sequencing of polymerase chain reaction (PCR) fragments to detect single nucleotide polymorphisms (SNPs) in a larger number of samples. Methods: The microarray was developed to affordably generate SNP data of genes encoding the human cytochrome P450 enzyme family (CYP) and N-acetyltransferase-2 (NAT2) involved in antimalarial drug metabolisms and with known polymorphisms, i.e. CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP3A4, CYP3A5, and NAT2. Results: For some SNPs, i.e. CYP2A6*2, CYP2B6*5, CYP2C8*3, CYP2C9*3/*5, CYP2C19*3, CYP2D6*4 and NAT2*6/*7/*14, agreement between both techniques ranged from substantial to almost perfect (kappa index between 0.61 and 1.00), whilst for other SNPs a large variability from slight to substantial agreement (kappa index between 0.39 and 1.00) was found, e. g. CYP2D6*17 (2850C>T), CYP3A4*1B and CYP3A5*3. Conclusion: The major limit of the microarray technology for this purpose was lack of robustness and with a large number of missing data or with incorrect specificity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L'objectif de ce travail est le développement d'une méthode de caractérisation objective de la qualité d'image s'appliquant à des systèmes de mammographie analogique, utilisant un couple écran-film comme détecteur, et numérique, basé sur une technologie semi-conductrice, ceci en vue de la comparaison de leurs performances. La méthode développée tient compte de la gamme dynamique du détecteur, de la détectabilité de structures de haut contraste, simulant des microcalcifications, et de structures de bas contraste, simulant des opacités (nodules tumoraux). La méthode prend également en considération le processus de visualisation de l'image, ainsi que la réponse de l'observateur. Pour réaliser ceci, un objet-test ayant des propriétés proches de celles d'un sein comprimé, composé de différents matériaux équivalents aux tissus, allant du glandulaire à l'adipeux, et comprenant des zones permettant la simulation de structures de haut et bas contraste, ainsi que la mesure de la résolution et celle du bruit, a été développé et testé. L'intégration du processus de visualisation a été réalisée en utilisant une caméra CCD mesurant directement les paramètres de qualité d'image, à partir de l'image de l'objet-test, dans une grandeur physique commune au système numérique et analogique, à savoir la luminance arrivant sur l'oeil de l'observateur. L'utilisation d'une grandeur synthétique intégrant dans un même temps, le contraste, le bruit et la résolution rend possible une comparaison objective entre les deux systèmes de mammographie. Un modèle mathématique, simulant la réponse d'un observateur et intégrant les paramètres de base de qualité d'image, a été utilisé pour calculer la détectabilité de structures de haut et bas contraste en fonction du type de tissu sur lequel celles-ci se trouvent. Les résultats obtenus montrent qu'à dose égale la détectabilité des structures est significativement plus élevée avec le système de mammographie numérique qu'avec le système analogique. Ceci est principalement lié au fait que le bruit du système numérique est plus faible que celui du système analogique. Les résultats montrent également que la méthodologie, visant à comparer des systèmes d'imagerie numérique et analogique en utilisant un objet-test à large gamme dynamique ainsi qu'une caméra, peut être appliquée à d'autres modalités radiologiques, ainsi qu'à une démarche d'optimisation des conditions de lecture des images.<br/><br/>The goal of this work was to develop a method to objectively compare the performance of a digital and a screen-film mammography system in terms of image quality and patient dose. We propose a method that takes into account the dynamic range of the image detector and the detection of high contrast (for microcalcifications) and low contrast (for masses or tumoral nodules) structures. The method also addresses the problems of image visualization and the observer response. A test object, designed to represent a compressed breast, was constructed from various tissue equivalent materials ranging from purely adipose to purely glandular composition. Different areas within the test object permitted the evaluation of low and high contrast detection, spatial resolution, and image noise. All the images (digital and conventional) were captured using a CCD camera to include the visualization process in the image quality assessment. In this way the luminance reaching the viewer?s eyes can be controlled for both kinds of images. A global quantity describing image contrast, spatial resolution and noise, and expressed in terms of luminance at the camera, can then be used to compare the two technologies objectively. The quantity used was a mathematical model observer that calculates the detectability of high and low contrast structures as a function of the background tissue. Our results show that for a given patient dose, the detection of high and low contrast structures is significantly better for the digital system than for the conventional screen-film system studied. This is mainly because the image noise is lower for the digital system than for the screen-film detector. The method of using a test object with a large dynamic range combined with a camera to compare conventional and digital imaging modalities can be applied to other radiological imaging techniques. In particular it could be used to optimize the process of radiographic film reading.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Thanks to the continuous progress made in recent years, medical imaging has become an important tool in the diagnosis of various pathologies. In particular, magnetic resonance imaging (MRI) permits to obtain images with a remarkably high resolution without the use of ionizing radiation and is consequently widely applied for a broad range of conditions in all parts of the body. Contrast agents are used in MRI to improve tissue discrimination. Different categories of contrast agents are clinically available, the most widely used being gadolinium chelates. One can distinguish between extracellular gadolinium chelates such as Gd-DTPA, and hepatobiliary gadolinium chelates such as Gd-BOPTA. The latter are able to enter hepatocytes from where they are partially excreted into the bile to an extent dependent on the contrast agent and animal species. Due to this property, hepatobiliary contrast agents are particularly interesting for the MRI of the liver. Actually, a change in signal intensity can result from a change in transport functions signaling the presence of impaired hepatocytes, e.g. in the case of focal (like cancer) or diffuse (like cirrhosis) liver diseases. Although the excretion mechanism into the bile is well known, the uptake mechanisms of hepatobiliary contrast agents into hepatocytes are still not completely understood and several hypotheses have been proposed. As a good knowledge of these transport mechanisms is required to allow an efficient diagnosis by MRI of the functional state of the liver, more fundamental research is needed and an efficient MRI compatible in vitro model would be an asset. So far, most data concerning these transport mechanisms have been obtained by MRI with in vivo models or by a method of detection other than MRI with cellular or sub-cellular models. Actually, no in vitro model is currently available for the study and quantification of contrast agents by MRI notably because high cellular densities are needed to allow detection, and no metallic devices can be used inside the magnet room, which is incompatible with most tissue or cell cultures that require controlled temperature and oxygenation. The aim of this thesis is thus to develop an MRI compatible in vitro cellular model to study the transport of hepatobiliary contrast agents, in particular Gd-BOPTA, into hepatocytes directly by MRI. A better understanding of this transport and especially of its modification in case of hepatic disorder could permit in a second step to extrapolate this knowledge to humans and to use the kinetics of hepatobiliary contrast agents as a tool for the diagnosis of hepatic diseases.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Résumé: L'automatisation du séquençage et de l'annotation des génomes, ainsi que l'application à large échelle de méthodes de mesure de l'expression génique, génèrent une quantité phénoménale de données pour des organismes modèles tels que l'homme ou la souris. Dans ce déluge de données, il devient très difficile d'obtenir des informations spécifiques à un organisme ou à un gène, et une telle recherche aboutit fréquemment à des réponses fragmentées, voir incomplètes. La création d'une base de données capable de gérer et d'intégrer aussi bien les données génomiques que les données transcriptomiques peut grandement améliorer la vitesse de recherche ainsi que la qualité des résultats obtenus, en permettant une comparaison directe de mesures d'expression des gènes provenant d'expériences réalisées grâce à des techniques différentes. L'objectif principal de ce projet, appelé CleanEx, est de fournir un accès direct aux données d'expression publiques par le biais de noms de gènes officiels, et de représenter des données d'expression produites selon des protocoles différents de manière à faciliter une analyse générale et une comparaison entre plusieurs jeux de données. Une mise à jour cohérente et régulière de la nomenclature des gènes est assurée en associant chaque expérience d'expression de gène à un identificateur permanent de la séquence-cible, donnant une description physique de la population d'ARN visée par l'expérience. Ces identificateurs sont ensuite associés à intervalles réguliers aux catalogues, en constante évolution, des gènes d'organismes modèles. Cette procédure automatique de traçage se fonde en partie sur des ressources externes d'information génomique, telles que UniGene et RefSeq. La partie centrale de CleanEx consiste en un index de gènes établi de manière hebdomadaire et qui contient les liens à toutes les données publiques d'expression déjà incorporées au système. En outre, la base de données des séquences-cible fournit un lien sur le gène correspondant ainsi qu'un contrôle de qualité de ce lien pour différents types de ressources expérimentales, telles que des clones ou des sondes Affymetrix. Le système de recherche en ligne de CleanEx offre un accès aux entrées individuelles ainsi qu'à des outils d'analyse croisée de jeux de donnnées. Ces outils se sont avérés très efficaces dans le cadre de la comparaison de l'expression de gènes, ainsi que, dans une certaine mesure, dans la détection d'une variation de cette expression liée au phénomène d'épissage alternatif. Les fichiers et les outils de CleanEx sont accessibles en ligne (http://www.cleanex.isb-sib.ch/). Abstract: The automatic genome sequencing and annotation, as well as the large-scale gene expression measurements methods, generate a massive amount of data for model organisms. Searching for genespecific or organism-specific information througout all the different databases has become a very difficult task, and often results in fragmented and unrelated answers. The generation of a database which will federate and integrate genomic and transcriptomic data together will greatly improve the search speed as well as the quality of the results by allowing a direct comparison of expression results obtained by different techniques. The main goal of this project, called the CleanEx database, is thus to provide access to public gene expression data via unique gene names and to represent heterogeneous expression data produced by different technologies in a way that facilitates joint analysis and crossdataset comparisons. A consistent and uptodate gene nomenclature is achieved by associating each single gene expression experiment with a permanent target identifier consisting of a physical description of the targeted RNA population or the hybridization reagent used. These targets are then mapped at regular intervals to the growing and evolving catalogues of genes from model organisms, such as human and mouse. The completely automatic mapping procedure relies partly on external genome information resources such as UniGene and RefSeq. The central part of CleanEx is a weekly built gene index containing crossreferences to all public expression data already incorporated into the system. In addition, the expression target database of CleanEx provides gene mapping and quality control information for various types of experimental resources, such as cDNA clones or Affymetrix probe sets. The Affymetrix mapping files are accessible as text files, for further use in external applications, and as individual entries, via the webbased interfaces . The CleanEx webbased query interfaces offer access to individual entries via text string searches or quantitative expression criteria, as well as crossdataset analysis tools, and crosschip gene comparison. These tools have proven to be very efficient in expression data comparison and even, to a certain extent, in detection of differentially expressed splice variants. The CleanEx flat files and tools are available online at: http://www.cleanex.isbsib. ch/.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

L'aquifère du Seeland représente une richesse en ressources hydriques qu'il est impératif de préserver contre tout risque de détérioration. Cet aquifère prolifique est constitué principalement de sédiments alluviaux post-glaciaires (graviers, sables et limons). Il est soumis aux contraintes environnementales des pratiques d'agriculture intensive, du réseau routier, des villes et de leurs activités industrielles. La connaissance optimale de ces ressources est donc primordiale pour leur protection. Dans cette optique, deux sites Kappelen et Grenchen représentatifs de l'aquifère du Seeland ont été étudiés. L'objectif de ce travail est de caractériser d'un point de vue hydrogéophysique l'aquifère au niveau de ces deux sites, c'est-à-dire, comprendre la dynamique des écoulements souterrains par l'application des méthodes électriques de surface associées aux diagraphies en intégrant des méthodes hydrogéologiques. Pour le site de Kappelen, les méthodes électriques de surface ont permis d'identifier les différents faciès géoélectriques en présence et de mettre en évidence leur disposition en une structure tabulaire et horizontale. Il s'agit d'un aquifère libre constitué d'une série de graviers allant jusqu'à 15 m de profondeur reposant sur de la moraine argileuse. Les diagraphies électriques, nucléaires et du fluide ont servis à la détermination des caractéristiques pétrophysiques et hydrauliques de l'aquifère qui contrôlent son comportement hydrodynamique. Les graviers aquifères de Kappelen présentent deux minéraux dominants: quartz et calcite. Les analyses minéralogiques indiquent que ces deux éléments constituent 65 à 75% de la matrice. La porosité totale obtenue par les diagraphies nucléaires varie de 20 à 30 %, et de 22 à 29 % par diagraphies électrique. Avec les faibles valeurs de Gamma Ray ces résultats indiquent que l'aquifère des graviers de Kappelen est dépourvu d'argile minéralogique. La perméabilité obtenue par diagraphies du fluide varie de 3.10-4 à 5.10-2 m/s, et par essais de pompage de 10-4 à 10-2 m/s. Les résultats des analyses granulométriques indiquent une hétérogénéité granulométrique au niveau des graviers aquifères. La fraction de sables, sables très fins, silts et limons constitue de 10 à 40 %. Ces éléments jouent un rôle important dans le comportement hydraulique de l'aquifère. La porosité efficace de 11 à 25% estimée à partir des résultats des analyses granulométriques suppose que les zones les plus perméables correspondent aux zones les plus graveleuses du site. Etablie sur le site de Kappelen, cette méthodologie a été utilisée sur le site de Grenchen. Les méthodes électriques de surface indiquent que l'aquifère captif de Grenchen est constitué des sables silteux comprenant des passages sableux, encadrés par des silts argileux imperméables. L'aquifère de Grenchen est disposé dans une structure relativement tabulaire et horizontale. Son épaisseur totale peut atteindre les 25 m vers le sud et le sud ouest ou les passages sableux sont les plus importants. La détermination des caractéristiques pétrophysiques et hydrauliques s'est faite à l'aide des diagraphies. Les intensités Gamma Ray varient de 30 à 100 cps, les plus fortes valeurs n'indiquent qu'une présence d'éléments argileux mais pas de bancs d'argile. Les porosités totales de 15 à 25% et les densités globales de 2.25 à 2.45 g/cm3 indiquent que la phase minérale (matrice) est composée essentiellement de quartz et de calcaire. Les densités de matrice varient entre 2.65 et 2.75 g/cm3. La perméabilité varie de 2 10-6 à 5 10-4 m/s. La surestimation des porosités totales à partir des diagraphies électriques de 25 à 42% est due à la présence d'argiles. -- The vast alluvial Seeland aquifer system in northwestern Switzerland is subjected to environmental challenges due to intensive agriculture, roads, cities and industrial activities. Optimal knowledge of the hydrological resources of this aquifer system is therefore important for their protection. Two representative sites, Kappelen and Grenchen, of the Seeland aquifer were investigated using surface-based geoelectric methods and geophysical borehole logging methods. By integrating of hydrogeological and hydrogeophysical methods, a reliable characterization of the aquifer system at these two sites can be performed in order to better understand the governing flow and transport process. At the Kappelen site, surface-based geoelectric methods allowed to identify various geoelectric facies and highlighted their tabular and horizontal structure. It is an unconfined aquifer made up of 15 m thick gravels with an important sandy fraction and bounded by a shaly glacial aquitard. Electrical and nuclear logging measurements allow for constraining the petrophysical and hydrological parameters of saturated gravels. Results indicate that in agreement with mineralogical analyses, matrix of the probed formations is dominated by quartz and calcite with densities of 2.65 and 2.71 g/cc, respectively. These two minerals constitute approximately 65 to 75 % of the mineral matrix. Matrix density values vary from 2.60 to 2.75 g/cc. Total porosity values obtained from nuclear logs range from 20 to 30 % and are consistent with those obtained from electrical logs ranging from 22 to 29 %. Together with the inherently low natural gamma radiation and the matrix density values obtained from other nuclear logging measurements, this indicates that at Kappelen site the aquifer is essentially devoid of clay. Hydraulic conductivity values obtained by the Dilution Technique vary between 3.10-4 and 5.10-2 m/s, while pumping tests give values ranging from 10-4 to 10-2 m/s. Grain size analysis of gravel samples collected from boreholes cores reveal significant granulometric heterogeneity of these deposits. Calculations based on these granulometric data have shown that the sand-, silt- and shale-sized fractions constitute between 10 and 40 % of the sample mass. The presence of these fine elements in general and their spatial distribution in particular are important as they largely control the distribution of the total and effective porosity as well as the hydraulic conductivity. Effective porosity values ranging from 11 to 25% estimated from grain size analyses indicate that the zones of higher hydraulic conductivity values correspond to the zones dominated by gravels. The methodology established at the Kappelen site was then applied to the Grenchen site. Results from surface-based geoelectric measurements indicate that it is a confined aquifer made up predominantly of shaly sands with intercalated sand lenses confined impermeable shally clay. The Grenchen confined aquifer has a relatively tabular and horizontal structure with a maximum thickness of 25 m in the south and the southwest with important sand passages. Petrophysical and hydrological characteristics were performed using electrical and nuclear logging. Natural gamma radiation values ranging from 30 to 100 cps indicate presence of a clay fraction but not of pure clay layers. Total porosity values obtained from electrical logs vary form 25 to 42%, whereas those obtained from nuclear logs values vary from 15 to 25%. This over-estimation confirms presences of clays. Density values obtained from nuclear logs varying from 2.25 to 2.45 g/cc in conjunction with the total porosity values indicate that the dominating matrix minerals are quartz and calcite. Matrix density values vary between 2.65 and 2.75 g/cc. Hydraulic conductivity values obtained by the Dilution Technique vary from 2 10-6 to 5 10-4 m/s.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Résumé destiné à un large public Le système immunitaire associé aux muqueuses gastro-intestinales doit être capable de protéger notre organisme contre l'invasion de pathogènes. Parallèlement, il doit identifier en Cant que tels, des composés inoffensifs comme la nourriture ou les milliards de bactéries qui résident dans notre intestin. Le travail présenté ici aborde ces deux aspects essentiels au bon fonctionnement de notre muqueuse intestinale. Dans une première partie, la protéine nommée pièce sécrétoire a été étudiée pour ses propriétés protectrices contre le pathogène viral rotavirus. Le rôle de la pièce sécrétoire est de transporter les anticorps que nous produisons vers la surface des muqueuses. En dehors de cette fonction bien connue, il se peut que cette protéine soit également capable de protéger notre organisme contre certains virus. L'hypothèse de travail était donc que la pièce sécrétoire se lie directement au virus, l'empêchant ainsi d'infecter des cellules épithéliales de l'intestin. En utilisant différentes techniques biochimiques, cette hypothèse s'est révélée fausse car aucune interaction entre la pièce sécrétoire et le virus n'a pu être observée, et logiquement, aucune protection n'a pu prendre place. En revanche, la pièce sécrétoire se lie à d'autres structures pathogéniques et permet ainsi de neutraliser leurs effets néfastes. La pièce sécrétoire participe donc activement à la protection de nos muqueuses, en plus de son rôle de transporteur. La deuxième partie de ce travail avait pour sujet les réactions inappropriées que le système immunitaire induit parfois contre un aliment, ou, autrement dit, les allergies alimentaires. Un modèle d'allergie alimentaire à donc été développé chez la souris et a permis de mesurer plusieurs symptômes et facteurs liés à l'allergie. Puis, ce modèle a été utilisé afin de tester les effets bénéfiques d'une bactérie lactique, dite probiotique, sur le développement de l'allergie. Il a été observé que, sous certaines circonstances, l'administration de la bactérie lactique protégeait entièrement les souris contre les réactions allergiques. L'effet bénéfique dépend donc du probiotique mais également d'autres facteurs encore inconnus â ce jour. Cette étude ouvre la voie sur la compréhension des mécanismes liés aux allergies alimentaires et sur l'impact que peuvent avoir les bactéries probiotiques sur cette maladie. Résumé Le système immunitaire associé aux muqueuses intestinales doit être capable de différencier les antigènes inoffensifs tels que 1a nourriture ou les bactéries commensales des microorganismes potentiellement dangereux. Cet aspect est essentiel pour le maintien de l'homéostase intestinale et fait l'objet du travail présenté ici. Dans un premier projet, les propriétés protectrices de la protéine appelée pièce sécrétoire (SC) ont été étudiées. SC est une protéine connue pour le transport des immunoglobulines à la surface des muqueuses. Cette protéine est fortement glycosylée paz des sucres complexes, ce qui nous a mené à postuler que SC puisse interagir avec le pathogène rotavirus. Cette hypothèse était soutenue par le fait que ce virus adhère aux cellules épithéliales par des résidus glycosylés. Des analyses biochimiques et biologiques ont démontré qu'aucune interaction entre SC et le virus ne prenait place, et que par conséquent SC n'offrait aucune protection contre ce pathogène. En revanche, SC interagit avec d'autres structures pathogéniques, comme la toxine A de Clostridium difficile, et la molécule d'adhésion intimine de la bactérie entéropathogène Escherichia coli. La liaison se fait par l'intermédiaire des sucres et confère ainsi une protection contre ces pathogènes. Ainsi, SC a été identifié comme agent neutralisant au niveau de l'intestin. La deuxième partie de ce travail abordait le sujet des allergies alimentaires, et avait pour but de tester les effets bénéfiques potentiels d'une bactérie probiotique, Lactobacillus paracasei NCC2461, contre les réactions allergiques. Un modèle marin d'allergie alimentaire a été mis au point, permettant de mesurer des immunoglobulines E, des symptômes allergiques, et la dégranulation de mastocytes. Lorsque le probiotique a été administré aux souris, celles-ci ont été complètement protégées des réactions allergiques dans une première expérience. Cependant, cette protection n'a pas été reproduite et suggère que des facteurs environnementaux encore inconnus sont critiques pour que le probiotique agisse positivement. Ce travail a permis de mettre en évidence la complexité de l'approche des traitements liés aux probiotiques et ouvre la voie sur la compréhension des mécanismes liés à l'allergie. Abstract The mucosal immune system associated to the gastrointestinal mucosa must efficiently distinguish between innocuous antigens, such as food proteins and commensal bacteria and potentially infectious agents. The work presented here deals with these two essential aspects guaranteeing intestinal homeostasis. In the first part of this work, the protective properties of secretory component (SC) toward the pathogen rotavirus were investigated. SC, which allows the transport of polymeric immunoglobulins (Ig) to mucosal surfaces, is highly glycosylated with complex glycan structures. The abundance and the nature of these carbohydrates led us to speculate that SC might interact with rotavirus, which is known to bind target cells with glycan receptors. Using various biological and biochemical techniques, we demonstrated that SC did not interact with rotaviruses, nor protected epithelial cells from infection. However, SC was shown to bind to Clostridium difficile toxin A and to the enteropathogenic Echerischia coli adhesion molecule intimin in a glycan-dependent fashion. These interactions allow in vitro protection of epithelial cells using physiological concentrations of SC. These data identify SC as a microbial scavenger at mucosal surfaces, and in the context of secretory IgA, further enhance the neutralising properties of the complex. The second project was inscribed in the domain of food allergy and aimed to test the modulatory functions of a probiotic strain of Lactobacillus paracasei toward allergic reactions. A model of food-mediated allergy was developed in the mouse using mucosal sensitisation. Several parameters associated to allergy were quantified after allergen challenge, and included allergen-specific IgE, allergic signs like diarrhea and temperature drop, and degranulation of mast cells. Administration of the probiotic strain was shown to completely protect mice from allergic reactions. However, these data were not reproduced, suggesting that unknown environmental factors are required so that protection mediated by the probiotic strain occurs. This study paves the way to the understanding of the mechanisms associated to allergy, and highlights the tremendous complexity that probiotic treatments will have to face.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To optimize and preliminarily evaluate a three-dimensional (3D) radial balanced steady-state free precession (bSSFP) arterial spin labeled (ASL) sequence for nonenhanced MR angiography (MRA) of the extracranial carotid arteries. MATERIALS AND METHODS: The carotid arteries of 13 healthy subjects and 2 patients were imaged on a 1.5 Tesla MRI system using an undersampled 3D radial bSSFP sequence providing a scan time of ∼4 min and 1 mm(3) isotropic resolution. A hybridized scheme that combined pseudocontinuous and pulsed ASL was used to maximize arterial coverage. The impact of a post label delay period, the sequence repetition time, and radiofrequency (RF) energy configuration of pseudocontinuous labeling on the display of the carotid arteries was assessed with contrast-to-noise ratio (CNR) measurements. Faster, higher undersampled 2 and 1 min scans were tested. RESULTS: Using hybridized ASL MRA and a 3D radial bSSFP trajectory, arterial CNR was maximized with a post label delay of 0.2 s, repetition times ≥ 2.5 s (P < 0.05), and by eliminating RF energy during the pseudocontinuous control phase (P < 0.001). With higher levels of undersampling, the carotid arteries were displayed in ≤ 2 min. CONCLUSION: Nonenhanced MRA using hybridized ASL with a 3D radial bSSFP trajectory can display long lengths of the carotid arteries with 1 mm(3) isotropic resolution. J. Magn. Reson. Imaging 2015;41:1150-1156. © 2014 Wiley Periodicals, Inc.