207 resultados para Blood Gas Monitoring, Transcutaneous
Resumo:
Genetically constructed microbial biosensors for measuring organic pollutants are mostly applied in aqueous samples. Unfortunately, the detection limit of most biosensors is insufficient to detect pollutants at low but environmentally relevant concentrations. However, organic pollutants with low levels of water solubility often have significant gas-water partitioning coefficients, which in principle makes it possible to measure such compounds in the gas rather than the aqueous phase. Here we describe the first use of a microbial biosensor for measuring organic pollutants directly in the gas phase. For this purpose, we reconstructed a bioluminescent Pseudomonas putida naphthalene biosensor strain to carry the NAH7 plasmid and a chromosomally inserted gene fusion between the sal promoter and the luxAB genes. Specific calibration studies were performed with suspended and filter-immobilized biosensor cells, in aqueous solution and in the gas phase. Gas phase measurements with filter-immobilized biosensor cells in closed flasks, with a naphthalene-contaminated aqueous phase, showed that the biosensor cells can measure naphthalene effectively. The biosensor cells on the filter responded with increasing light output proportional to the naphthalene concentration added to the water phase, even though only a small proportion of the naphthalene was present in the gas phase. In fact, the biosensor cells could concentrate a larger proportion of naphthalene through the gas phase than in the aqueous suspension, probably due to faster transport of naphthalene to the cells in the gas phase. This led to a 10-fold lower detectable aqueous naphthalene concentration (50 nM instead of 0.5 micro M). Thus, the use of bacterial biosensors for measuring organic pollutants in the gas phase is a valid method for increasing the sensitivity of these valuable biological devices.
Resumo:
The toxicity of yew (Taxus spp) is well known from ancient times and is mainly due to taxins acting as inhibitors of calcium and sodium transport across the cell membrane of cardiac myocytes. The confirmation of yew taxins in body fluids can be carried out by liquid chromatography-tandem mass spectrometry (LC-MS/MS). However, before selecting this precise but expensive technique, an orientation test should be done to ascertain yew presence as toxic agent in the organism. As the 3,5-dimethoxyphenol (3,5-DMP), myrtenol and 1-octen-3-ol appear as glycosidically bound volatile compounds and are very yew specific, the detection of 3,5-DMP and the measurement of 1-octen-3-ol / myrtenol concentration ratio constitute reliable indicators of yew presence in forensic cases. The detection of these compounds is easily performed by gas chromatography-mass spectrometry (GC-MS) (SIM) after an enzymatic hydrolysis (β-glucosidase) allowing the release of volatile compounds from yew glycosides. Copyright © 2012 John Wiley & Sons, Ltd.
Resumo:
The role of busulfan (Bu) metabolites in the adverse events seen during hematopoietic stem cell transplantation and in drug interactions is not explored. Lack of availability of established analytical methods limits our understanding in this area. The present work describes a novel gas chromatography-tandem mass spectrometric assay for the analysis of sulfolane (Su) in plasma of patients receiving high-dose Bu. Su and Bu were extracted from a single 100 μL plasma sample by liquid-liquid extraction. Bu was separately derivatized with 2,3,5,6-tetrafluorothiophenolfluorinated agent. Mass spectrometric detection of the analytes was performed in the selected reaction monitoring mode on a triple quadrupole instrument after electronic impact ionization. Bu and Su were analyzed with separate chromatographic programs, lasting 5 min each. The assay for Su was found to be linear in the concentration range of 20-400 ng/mL. The method has satisfactory sensitivity (lower limit of quantification, 20 ng/mL) and precision (relative standard deviation less than 15 %) for all the concentrations tested with a good trueness (100 ± 5 %). This method was applied to measure Su from pediatric patients with samples collected 4 h after dose 1 (n = 46), before dose 7 (n = 56), and after dose 9 (n = 54) infusions of Bu. Su (mean ± SD) was detectable in plasma of patients 4 h after dose 1, and higher levels were observed after dose 9 (249.9 ± 123.4 ng/mL). This method may be used in clinical studies investigating the role of Su on adverse events and drug interactions associated with Bu therapy.
Resumo:
A gas chromatographic-mass spectrometric (GC-MS) method has been developed, for the determination of trimipramine (TRI), desmethyltrimipramine (DTRI), didesmethyltrimipramine (DDTRI), 2-hydroxytrimipramine (2-OH-TRI) and 2-hydroxydesmethyltrimipramine (2-OH-DTRI). The method includes two derivatization steps with trifluoroacetic acid anhydride and N-methyl-N-(tert.-butyldimethyl silyl)trifluoroacetamide and the use of an SE-54 capillary silica column. The limits of quantitation were found to be 2 ng/ml for DTRI and 4 ng/ml for all other substances. Besides, methods have been optimized for the hydrolysis of the glucuronic acid conjugated metabolites. This specific detection method is useful, as polymedication is a usual practice in clinical situations, and its sensitivity allows its use for single-dose pharmacokinetic studies.
Resumo:
L'imagerie est de plus en plus utilisée en médecine forensique. Actuellement, les connaissances nécessaires pour interpréter les images post mortem sont faibles et surtout celles concernant les artéfacts post mortem. Le moyen radiologique le plus utilisé en médecine légale est la tomodensitométrie multi-coupes (TDMC). Un de ses avantages est la détection de gaz dans le corps. Cette technique est utile au diagnostic d'embolie gazeuse mais sa très grande sensibilité rend visible du gaz présent même en petite quantité. Les premières expériences montrent que presque tous les corps scannés présentent du gaz surtout dans le système vasculaire. Pour cette raison, le médecin légiste est confronté à un nouveau problème : la distinction entre du gaz d'origine post-mortem et une embolie gazeuse vraie. Pour parvenir à cette distinction, il est essentiel d'étudier la distribution de ces gaz en post mortem. Aucune étude systématique n'a encore été réalisée à ce jour sur ce sujet.¦Nous avons étudié l'incidence et la distribution des gaz présents en post mortem dans les vaisseaux, dans les os, dans les tissus sous-cutanés, dans l'espace sous-dural ainsi que dans les cavités crânienne, thoracique et abdominale (82 sites au total) de manière à identifier les facteurs qui pourraient distinguer le gaz post-mortem artéfactuel d'une embolie gazeuse¦Les données TDMC de 119 cadavres ont été étudiées rétrospectivement. Les critères d'inclusion des sujets sont l'absence de lésion corporelle permettant la contamination avec l'air extérieur, et, la documentation du délai entre le moment du décès et celui du CT-scan (p.ex. rapport de police, protocole de réanimation ou témoin). La présence de gaz a été évaluée semi-quantitativement par deux radiologues et codifiée. La codification est la suivante : grade 0 = pas de gaz, grade 1 = une à quelques bulles d'air, grade 2 = structure partiellement remplie d'air, grade 3 = structure complètement remplie d'air.¦Soixante-quatre des 119 cadavres présentent du gaz (62,2%), et 56 (75,7%) ont montré du gaz dans le coeur. Du gaz a été détecté le plus fréquemment dans le parenchyme hépatique (40%); le coeur droit (ventricule 38%, atrium 35%), la veine cave inférieure (infra-rénale 30%, supra-rénale 26%), les veines sus-hépatiques (gauche 26%, moyenne 29%, droite 22 %), et les espaces du porte (29%). Nous avons constaté qu'une grande quantité de gaz liée à la putréfaction présente dans le coeur droit (grade 3) est associée à des collections de gaz dans le parenchyme hépatique (sensibilité = 100%, spécificité = 89,7%). Pour décrire nos résultats, nous avons construit une séquence d'animation qui illustre le processus de putréfaction et l'apparition des gaz à la TDMC post-mortem.¦Cette étude est la première à montrer que l'apparition post-mortem des gaz suit un modèle de distribution spécifique. L'association entre la présence de gaz intracardiaque et dans le parenchyme hépatique pourrait permettre de distinguer du gaz artéfactuel d'origine post-mortem d'une embolie gazeuse vraie. Cette étude fournit une clé pour le diagnostic de la mort due à une embolie gazeuse cardiaque sur la base d'une TDMC post-mortem.¦Abstract¦Purpose: We investigated the incidence and distribution of post-mortem gas detected with multidetector computed tomography (MDCT) to identify factors that could distinguish artifactual gas from cardiac air embolism.¦Material and Methods: MDCT data of 119 cadavers were retrospectively examined. Gas was semiquantitatively assessed in selected blood vessels, organs and body spaces (82 total sites).¦Results: Seventy-four of the 119 cadavers displayed gas (62.2%; CI 95% 52.8 to 70.9), and 56 (75.7%) displayed gas in the heart. Most gas was detected in the hepatic parenchyma (40%); right heart (38% ventricle, 35% atrium), inferior vena cava (30% infrarenally, 26% suprarenally), hepatic veins (26% left, 29% middle, 22% right), and portal spaces (29%). Male cadavers displayed gas more frequently than female cadavers. Gas was detected 5-84 h after death; therefore, the post-mortem interval could not reliably predict gas distribution (rho=0.719, p<0.0001). We found that a large amount of putrefaction-generated gas in the right heart was associated with aggregated gas bubbles in the hepatic parenchyma (sensitivity = 100%, specificity = 89.7%). In contrast, gas in the left heart (sensitivity = 41.7%, specificity = 100%) or in peri-umbilical subcutaneous tissues (sensitivity = 50%, specificity = 96.3%) could not predict gas due to putrefaction.¦Conclusion: This study is the first to show that the appearance of post-mortem gas follows a specific distribution pattern. An association between intracardiac gas and hepatic parenchymal gas could distinguish between post- mortem-generated gas and vital air embolism. We propose that this finding provides a key for diagnosing death due to cardiac air embolism.
Resumo:
Ambulatory blood pressure (BP) monitoring is increasingly used in the evaluation of hypertensive patients. The ability to monitor BP throughout the day and night allows the detection of abnormal nocturnal BP patterns, the most common being a "nondipping" pattern, which is associated with increased cardiovascular risk; its correction appears to have a positive impact on cardiovascular outcome. Antihypertensive treatment should be individually adjusted to control BP during both daytime and nighttime. However, drug-induced lowering of nocturnal BP, if excessive, could amplify the morning BP surge in patients with daytime BP elevation, increasing the risk of developing a cardiovascular event. Ambulatory BP monitoring therefore represents a unique tool to establish the most appropriate antihypertensive drug regimen for the individual patient.
Resumo:
OBJECTIVE: To examine the compliance to medication among newly diagnosed hypertensive patients screened from the general population of the Seychelles, a rapidly developing country. METHODS: Among the 1067 participants to a population-based survey for cardiovascular risk factors, hypertension was discovered in 50 (previously unaware of having hypertension and having blood pressure > or = 160/95 mmHg over 3 visits). These 50 patients were placed on a daily one-pill regimen of medication (bendrofluazide, atenolol, or a combination of hydrochlorothiazide and atenolol) and compliance to the regimen was assessed over 12 months using electronic pill containers. Satisfactory compliance was defined as taking the medication on 6 or 7 days a week on average (which corresponds to a mean compliance level of > or = 86%). FINDINGS: In the first month, fewer than half (46%) of the new hypertension patients achieved satisfactory compliance, and only about one-quarter (26%) achieved this level by the twelfth month. Compliance was better among the 23 participants who regularly attended medical follow-up, with nearly three-quarters of these patients (74%) achieving satisfactory compliance during the first month and over one-half (55%) by the twelfth month. There was a direct association between mean 12-month compliance level and having a highly skilled occupation; having good health awareness; and regularly attending medical appointments. In contrast, there was an inverse relationship between mean compliance level and heavy drinking. CONCLUSION: The low proportion of people selected from the general population who were capable of sustaining satisfactory compliance to antihypertension medication may correspond to the maximum effectiveness of medication interventions based on a screening and treatment strategy in the general population. The results stress the need for both high-risk and population approaches to improve hypertension control.
Resumo:
Aims: Plasma concentrations of imatinib differ largely between patients despite same dosage, owing to large inter-individual variability in pharmacokinetic (PK) parameters. As the drug concentration at the end of the dosage interval (Cmin) correlates with treatment response and tolerability, monitoring of Cmin is suggested for therapeutic drug monitoring (TDM) of imatinib. Due to logistic difficulties, random sampling during the dosage interval is however often performed in clinical practice, thus rendering the respective results not informative regarding Cmin values.Objectives: (I) To extrapolate randomly measured imatinib concentrations to more informative Cmin using classical Bayesian forecasting. (II) To extend the classical Bayesian method to account for correlation between PK parameters. (III) To evaluate the predictive performance of both methods.Methods: 31 paired blood samples (random and trough levels) were obtained from 19 cancer patients under imatinib. Two Bayesian maximum a posteriori (MAP) methods were implemented: (A) a classical method ignoring correlation between PK parameters, and (B) an extended one accounting for correlation. Both methods were applied to estimate individual PK parameters, conditional on random observations and covariate-adjusted priors from a population PK model. The PK parameter estimates were used to calculate trough levels. Relative prediction errors (PE) were analyzed to evaluate accuracy (one-sample t-test) and to compare precision between the methods (F-test to compare variances).Results: Both Bayesian MAP methods allowed non-biased predictions of individual Cmin compared to observations: (A) - 7% mean PE (CI95% - 18 to 4 %, p = 0.15) and (B) - 4% mean PE (CI95% - 18 to 10 %, p = 0.69). Relative standard deviations of actual observations from predictions were 22% (A) and 30% (B), i.e. comparable to the intraindividual variability reported. Precision was not improved by taking into account correlation between PK parameters (p = 0.22).Conclusion: Clinical interpretation of randomly measured imatinib concentrations can be assisted by Bayesian extrapolation to maximum likelihood Cmin. Classical Bayesian estimation can be applied for TDM without the need to include correlation between PK parameters. Both methods could be adapted in the future to evaluate other individual pharmacokinetic measures correlated to clinical outcomes, such as area under the curve(AUC).
Resumo:
Ethyl glucuronide (EtG) is a minor and direct metabolite of ethanol. EtG is incorporated into the growing hair allowing retrospective investigation of chronic alcohol abuse. In this study, we report the development and the validation of a method using gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS) for the quantification of EtG in hair. EtG was extracted from about 30 mg of hair by aqueous incubation and purified by solid-phase extraction (SPE) using mixed mode extraction cartridges followed by derivation with perfluoropentanoic anhydride (PFPA). The analysis was performed in the selected reaction monitoring (SRM) mode using the transitions m/z 347-->163 (for the quantification) and m/z 347-->119 (for the identification) for EtG, and m/z 352-->163 for EtG-d(5) used as internal standard. For validation, we prepared quality controls (QC) using hair samples taken post mortem from 2 subjects with a known history of alcoholism. These samples were confirmed by a proficiency test with 7 participating laboratories. The assay linearity of EtG was confirmed over the range from 8.4 to 259.4 pg/mg hair, with a coefficient of determination (r(2)) above 0.999. The limit of detection (LOD) was estimated with 3.0 pg/mg. The lower limit of quantification (LLOQ) of the method was fixed at 8.4 pg/mg. Repeatability and intermediate precision (relative standard deviation, RSD%), tested at 4 QC levels, were less than 13.2%. The analytical method was applied to several hair samples obtained from autopsy cases with a history of alcoholism and/or lesions caused by alcohol. EtG concentrations in hair ranged from 60 to 820 pg/mg hair.
Resumo:
The aim of the study is to present the application of a headspace-gas chromatography-mass spectrometry (HS-GC-MS) method for the determination of the carbon monoxide (CO) blood concentration and to compare it with carboxyhemoglobin (HbCO) saturation. In postmortem cases, the HbCO measured by spectrophotometry frequently leads to inaccurate results due to inadequate samples or analyses. The true role of CO intoxication in the death of a person could be misclassified. The estimation of HbCO from HS-GC-MS CO measurements provides helpful information by determining the total CO levels (CO linked to hemoglobin (HbCO) and CO dissociated from hemoglobin). The CO concentrations were converted in HbCO saturation levels to define cutoff blood CO values. CO limits were defined as less than 1 μmol/mL for living persons, less than 1.5 μmol/mL for dead persons without CO exposure, and greater than 3 μmol/mL for dead persons with clear CO poisoning.
Resumo:
The persistence of high blood pressure under antihypertensive treatment (resistant hypertension) entails an increased cardiovascular risk. It occurs in three of ten treated hypertensive patients, and has several possible contributing factors, notably insufficient therapeutic adherence. There are a number of ways to evaluate whether patients take their medication as prescribed. These include interviewing the patient, pill counting, prescription follow-up, assay of drugs in blood or urine, and use of electronic pill dispensers. None is perfect. However, the essential is to discuss with the patient the importance of complying with the treatment as soon as it is prescribed for the first time, and not waiting for the appearance of resistant hypertension. The measurement of blood pressure outside the medical office and the monitoring of adherence may help to identify patients in whom hypertension is truly resistant and so to tailor the measures required to improve the control of blood pressure in the most appropriate manner.
Resumo:
The prescription information (summary of product characteristics, SPC) is compiled by the pharmaceutical industry as required by the national regulatory authorities. They vary in their content about the properties of drugs and about the usefulness of therapeutic drug monitoring (TDM) in the blood of patients. Based on a previous study carried out in Germany, the degree of agreement of French SPC for 59 psychotropic drugs with the existing medico-scientific evidence in the area of TDM was examined using a recently developed instrument. A summary score of SPC content (SPCC) related to TDM (SPCC(TDM)) has been calculated and compared with the level of recommendation of TDM of the AGNP-TDM expert group consensus guidelines for TDM in psychiatry [AGNP: Arbeitsgemeinschaft für Neuropsychopharmakologie und Pharmakopsychiatrie (Association for neuropsychopharmacology and pharmacopsychiatry)]. Among the antidepressants, antipsychotics, tranquillizers/hypnotic agents and mood stabilizers, the highest SPCC(TDM) scores in the French SPC were reached for imipramine (16), haloperidol (6), clonazepam (8) and lithium (23), respectively. Results were similar to those obtained from the analysis of German SPC, and considerable disagreement was found between the information on TDM in SPC and existing medico-scientific evidence, albeit less in the case of mood stabilizers. Taking into account the recommendations of the AGNP-TDM expert group guidelines, there is a deficit in the French SPC concerning TDM-relevant information. An amelioration of this situation could help to improve the clinical practice of TDM of psychotropic drugs, as the SPC is a widely used tool.
Resumo:
Background: Thus far, the correlation of noninvasive markers with endoscopic activity in ulcerative colitis (UC) according to the modified Baron Index is unknown. We aimed to evaluate the correlation between endoscopic activity and fecal calprotectin (FC), C-reactive protein (CRP), blood leukocytes, and the Lichtiger Index (clinical score). Methods: UC patients undergoing complete colonoscopy were prospectively enrolled and scored clinically and endoscopically in an independent fashion. Fecal and blood samples were analyzed in UC patients and controls. Results: We enrolled 228 UC patients and 52 controls. Endoscopic disease activity correlated best with FC (Spearman's rank correlation coefficient r = 0.821), followed by the Lichtiger Index (r = 0.682), CRP (r = 0.556), and leukocytes (r = 0.401). FC was the only marker discriminating between different grades of endoscopic activity (grade 0, 20}11 mg/g; grade 1, 44}34 mg/g; grade 2, 111}74 mg/g; grade 3, 330}332 mg/g; grade 4, 659}319 mg/g; P = 0.0018 for discriminating grade 0 vs. 1 and P < 0.001 for discriminating all other grades). FC had the highest overall accuracy (91%) to detect endoscopically active disease (modified Baron Index _2), followed by the Lichtiger Index of _4 (77%), CRP larger than 5 mg/L (69%) and blood leukocytosis (58%). Conclusions: FC better correlated with the endoscopic disease activity than clinical activity, CRP, and blood leukocytes. The strong correlation with endoscopic disease activity suggests that FC represents a useful biomarker for noninvasive monitoring of disease activity in UC patients.
Resumo:
Rapport de synthèse : Hypoglycémies nocturnes chez les patients diabétiques de type 1 : que pouvons-nous apprendre de la mesure de la glycémie en continu ? But : les hypoglycémies nocturnes sont une complication majeure du traitement des patients diabétiques de type 1; des autocontrôles de la glycémie capillaire sont donc recommandés pour les détecter. Cependant, la majorité des hypoglycémies nocturnes ne sont pas décelées par un autocontrôle glycémique durant la nuit. La mesure de la glycémie en continu (CGMS) est une alternative intéressante. Les buts de cette étude rétrospective étaient d'évaluer la véritable incidence des hypoglycémies nocturnes chez des patients diabétiques de type 1, la meilleure période pour effectuer un autocontrôle permettant de prédire une hypoglycémie nocturne, la relation entre les hyperglycémies matinales et les hypoglycémies nocturnes (phénomène de Somogyi) ainsi que l'utilité du CGMS pour réduire les hypoglycémies nocturnes. Méthode : quatre-vingt-huit patients diabétiques de type 1 qui avaient bénéficié d'un CGMS ont été inclus. Les indications au CGMS, les hypoglycémies nocturnes et diurnes ainsi que la corrélation entre les hypoglycémies nocturnes et les hyperglycémies matinales durant le CGMS ont été enregistrées. L'efficacité du CGMS pour réduire les hypoglycémies nocturnes a été évaluée six à neuf mois après. Résultats : la prévalence des hypoglycémies nocturnes était de 67% (32% non suspectées). La sensibilité d'une hypoglycémie à prédire une hypoglycémie nocturne était de 37% (OR = 2,37, P = 0,001) lorsqu'elle survient au coucher (22-24 h) et de 43% lorsqu'elle survient à 3 h (OR = 4,60, P < 0,001). Les hypoglycémies nocturnes n'étaient pas associées à des hyperglycémies matinales, mais à des hypoglycémies matinales (OR = 3.95, P < 0.001). Six à neuf mois après le CGMS, les suspicions cliniques d'hypoglycémies nocturnes ont diminué de 60% à 14% (P < 0.001). Abstract : Aim. - In type 1 diabetic patients (TIDM), nocturnal hypoglycaemias (Nlï) are a serious complication of T1DM treatment; self-monitoring of blood glucose (SMBG) is recommended to detect them. However, the majority of NH remains undetected on an occasional SMBG done during the night. An alternative strategy is the Continuous glucose monitoring (CGMS), which retrospectively shows the glycaemic profile. The aims of this retrospective study were to evaluate the true incidence of NH in TiDM, the bèst SMBG time to predict NH, the relationship between morning hyperglycaemia and N$ (Somogyi phenomenon) and the utility of CGMS to reduce NH. Methods. -Eighty-eight T1DM who underwent a CGMS exam were included. Indications for CGMS evaluarion, hypoglycaemias and correlation with morning hyperglycaemias were recorded. The efficiency of CGMS to reduce the suspected NH was evaluated after 6-9 months. Results. -The prevalence of NH was 67% (32% of them unsuspected). A measured hypoglycaemia at bedtime (22-24 h) had a sensitivity of 37% to detect NH (OR = 2.37, P = 0.001), while a single measure <_ 4 mmol/l at 3-hour had a sensitivity of 43% (OR = 4.60, P < 0.001). NH were not associated with morning hyperglycaemias but with morning hypoglycaemias (OR = 3.95, P < 0.001). After 6-9 months, suspicions of NH decreased from 60 to 14% (P < 0.001). Conclusion. - NH were highly prevalent and often undetected. SMBG at bedtime, which detected hypoglycaemia had sensitivity almost equal to that of 3-hour and should be preferred because it is easier to perform. Somogyi phenomenon was not observed. CGMS is useful to reduce the risk of NH in 75% of patients.