218 resultados para safety monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new ambulatory method of monitoring physical activities in Parkinson's disease (PD) patients is proposed based on a portable data-logger with three body-fixed inertial sensors. A group of ten PD patients treated with subthalamic nucleus deep brain stimulation (STN-DBS) and ten normal control subjects followed a protocol of typical daily activities and the whole period of the measurement was recorded by video. Walking periods were recognized using two sensors on shanks and lying periods were detected using a sensor on trunk. By calculating kinematics features of the trunk movements during the transitions between sitting and standing postures and using a statistical classifier, sit-to-stand (SiSt) and stand-to-sit (StSi) transitions were detected and separated from other body movements. Finally, a fuzzy classifier used this information to detect periods of sitting and standing. The proposed method showed a high sensitivity and specificity for the detection of basic body postures allocations: sitting, standing, lying, and walking periods, both in PD patients and healthy subjects. We found significant differences in parameters related to SiSt and StSi transitions between PD patients and controls and also between PD patients with and without STN-DBS turned on. We concluded that our method provides a simple, accurate, and effective means to objectively quantify physical activities in both normal and PD patients and may prove useful to assess the level of motor functions in the latter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of forensic intelligence relies on the expression of suitable models that better represent the contribution of forensic intelligence in relation to the criminal justice system, policing and security. Such models assist in comparing and evaluating methods and new technologies, provide transparency and foster the development of new applications. Interestingly, strong similarities between two separate projects focusing on specific forensic science areas were recently observed. These observations have led to the induction of a general model (Part I) that could guide the use of any forensic science case data in an intelligence perspective. The present article builds upon this general approach by focusing on decisional and organisational issues. The article investigates the comparison process and evaluation system that lay at the heart of the forensic intelligence framework, advocating scientific decision criteria and a structured but flexible and dynamic architecture. These building blocks are crucial and clearly lay within the expertise of forensic scientists. However, it is only part of the problem. Forensic intelligence includes other blocks with their respective interactions, decision points and tensions (e.g. regarding how to guide detection and how to integrate forensic information with other information). Formalising these blocks identifies many questions and potential answers. Addressing these questions is essential for the progress of the discipline. Such a process requires clarifying the role and place of the forensic scientist within the whole process and their relationship to other stakeholders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 2008 we published the first set of guidelines for standardizing research in autophagy. Since then, research on this topic has continued to accelerate, and many new scientists have entered the field. Our knowledge base and relevant new technologies have also been expanding. Accordingly, it is important to update these guidelines for monitoring autophagy in different organisms. Various reviews have described the range of assays that have been used for this purpose. Nevertheless, there continues to be confusion regarding acceptable methods to measure autophagy, especially in multicellular eukaryotes. A key point that needs to be emphasized is that there is a difference between measurements that monitor the numbers or volume of autophagic elements (e.g., autophagosomes or autolysosomes) at any stage of the autophagic process vs. those that measure flux through the autophagy pathway (i.e., the complete process); thus, a block in macroautophagy that results in autophagosome accumulation needs to be differentiated from stimuli that result in increased autophagic activity, defined as increased autophagy induction coupled with increased delivery to, and degradation within, lysosomes (in most higher eukaryotes and some protists such as Dictyostelium) or the vacuole (in plants and fungi). In other words, it is especially important that investigators new to the field understand that the appearance of more autophagosomes does not necessarily equate with more autophagy. In fact, in many cases, autophagosomes accumulate because of a block in trafficking to lysosomes without a concomitant change in autophagosome biogenesis, whereas an increase in autolysosomes may reflect a reduction in degradative activity. Here, we present a set of guidelines for the selection and interpretation of methods for use by investigators who aim to examine macroautophagy and related processes, as well as for reviewers who need to provide realistic and reasonable critiques of papers that are focused on these processes. These guidelines are not meant to be a formulaic set of rules, because the appropriate assays depend in part on the question being asked and the system being used. In addition, we emphasize that no individual assay is guaranteed to be the most appropriate one in every situation, and we strongly recommend the use of multiple assays to monitor autophagy. In these guidelines, we consider these various methods of assessing autophagy and what information can, or cannot, be obtained from them. Finally, by discussing the merits and limits of particular autophagy assays, we hope to encourage technical innovation in the field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Requesting a blood level measurement of a drug is part of the global approach known as "Therapeutic Drug Monitoring". Diverse situations require this monitoring approach, such as inadequate response to treatment or organ failure. Every drug however does not possess all the characteristics for a TDM program. The therapeutic range of a TDM drug has indeed to be narrow and its interindividual pharmacokinetic variability to be wide. As the development of new drugs is currently slowing down, the precise management of existing treatments certainly deserves progress, but needs however to be applied rationally, starting from a valid indication to blood sampling, and ending with a sound dosage adaptation decision.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Recommendations for EEG monitoring in the ICU are lacking. The Neurointensive Care Section of the ESICM assembled a multidisciplinary group to establish consensus recommendations on the use of EEG in the ICU. METHODS: A systematic review was performed and 42 studies were included. Data were extracted using the PICO approach, including: (a) population, i.e. ICU patients with at least one of the following: traumatic brain injury, subarachnoid hemorrhage, intracerebral hemorrhage, stroke, coma after cardiac arrest, septic and metabolic encephalopathy, encephalitis, and status epilepticus; (b) intervention, i.e. EEG monitoring of at least 30 min duration; (c) control, i.e. intermittent vs. continuous EEG, as no studies compared patients with a specific clinical condition, with and without EEG monitoring; (d) outcome endpoints, i.e. seizure detection, ischemia detection, and prognostication. After selection, evidence was classified and recommendations developed using the GRADE system. RECOMMENDATIONS: The panel recommends EEG in generalized convulsive status epilepticus and to rule out nonconvulsive seizures in brain-injured patients and in comatose ICU patients without primary brain injury who have unexplained and persistent altered consciousness. We suggest EEG to detect ischemia in comatose patients with subarachnoid hemorrhage and to improve prognostication of coma after cardiac arrest. We recommend continuous over intermittent EEG for refractory status epilepticus and suggest it for patients with status epilepticus and suspected ongoing seizures and for comatose patients with unexplained and persistent altered consciousness. CONCLUSIONS: EEG monitoring is an important diagnostic tool for specific indications. Further data are necessary to understand its potential for ischemia assessment and coma prognostication.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Poor compliance with antihypertensive drug regimens is one recognized cause of inadequate blood pressure control. Compliance is difficult to measure, so poor adherence to treatment remains largely undiagnosed in clinical practice. When the therapeutic response to a drug is not the one expected, it is a major challenge for many physicians to decide whether the patient is a non-responder or a non-complier. Poor compliance is therefore often incorrectly interpreted as a lack of response to treatment. Not detecting non-compliance can lead to the wrong measures being taken. Electronic monitoring of compliance provides important longitudinal information about drug-intake behaviour that cannot be obtained in the clinic. Such monitoring can improve both compliance and blood pressure control, and help physicians to make more rational therapeutic decisions. A reliable assessment of compliance could have a great impact on medical costs by preventing unnecessary investigations or dose adaptations in patients who are not taking their drugs adequately, or potentially reducing the number of hospitalizations. Side-effects and lack of effectiveness are two frequent causes of poor compliance. The right choice of antihypertensive drug can therefore contribute to compliance. In this respect, it is important to find a drug regimen that is effective, long-acting and well tolerated. Long-acting antihypertensive drugs that provide good blood pressure control beyond the 24-h dosing period should perhaps be considered as drugs of choice in non-compliant patients with hypertension because they help to prevent the consequences of occasional drug omissions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Blood pressures measured casually by a doctor often differ considerably from those recorded during everyday activities away from the medical environment. In the present study, we compared office and ambulatory recorded pressures in 475 consecutive untreated patients diagnosed hypertensive by physicians. Blood pressure monitored non-invasively during the day was, on average 15/7 mmHg lower than the corresponding office pressures. The difference between office and ambulatory recorded pressure tended to be greatest in those patients with the highest office blood pressure levels, although the relationship between the two types of measurement was too weak (r = 0.50 and 0.38 for systolic and diastolic pressure, respectively) to have any predictive value in the individual patient. Office blood pressures were at least 10 mmHg higher than ambulatory pressures in 62% of patients for systolic and 42% for diastolic pressure. Blood pressure levels recorded during ambulatory monitoring were higher than in the doctor's office for 18% of patients for systolic and 22% for diastolic pressure. Among patients with systolic pressures of between 161 and 180 mmHg or diastolic pressures between 96 and 105 mmHg when facing a doctor, 27 and 37% respectively, showed markedly lower systolic (less than 140 mmHg) or diastolic (less than 90 mmHg) ambulatory recorded pressures. These data therefore indicate that ambulatory blood pressure monitoring may help to identify those truly hypertensive patients who are most likely to benefit from antihypertensive therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immunotherapy of melanoma is aimed to mobilize cytolytic CD8+ T cells playing a central role in protective immunity. Despite numerous clinical vaccine trials, only few patients exhibited strong antigen-specific T-cell activation, stressing the need to improve vaccine strategies. For a rational development, we propose to focus on molecularly defined vaccine components, and evaluate their immunogenicity with highly reproducible and standardized methods for ex vivo immune monitoring. Careful immunogenicity comparison of vaccine formulations in phase I/II studies allow to select optimized vaccines for subsequent clinical efficacy testing in large scale phase III trials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High-dose cefepime therapy is recommended for febrile neutropenia. Safety issues have been raised in a recent meta-analysis reporting an increased risk of mortality during cefepime therapy. Cefepime-related neurological toxicity has been associated with overdosing due to severe renal dysfunction. This study aimed to investigate the association between cefepime plasma concentrations and neurological toxicity in febrile neutropenic patients. Cefepime trough concentrations (by high-performance liquid chromatography) were retrospectively analyzed for 30 adult febrile neutropenic patients receiving the recommended high-dose regimen (6 g/day for a glomerular filtration rate [GFR] of >50 ml/min). The dose adjustment to renal function was evaluated by the ratio of the cefepime daily dose per 100 ml/min of glomerular filtration. The association between cefepime plasma concentrations and neurological toxicity was assessed on the basis of consistent neurological symptoms and/or signs (by NCI criteria). The median cefepime concentration was 8.7 mg/liter (range, 2.1 to 38 mg/liter) at a median of 4 days (range, 2 to 15 days) after the start of therapy. Neurological toxicity (altered mental status, hallucinations, or myoclonia) was attributed to cefepime in 6/30 (20%) patients (median GFR, 45 ml/min; range, 41 to 65 ml/min) receiving a median dose of 13.2 g/day per 100 ml/min GFR (range, 9.2 to 14.3 g/day per 100 ml/min GFR). Cefepime discontinuation resulted in complete neurological recovery for five patients and improvement for one patient. A multivariate logistic regression model confirmed high cefepime concentrations as an independent predictor of neurological toxicity, with a 50% probability threshold at ≥22 mg/liter (P = 0.05). High cefepime plasma concentrations are associated with neurological toxicity in febrile neutropenic patients with mild renal dysfunction. Careful adherence to normalized dosing per 100 ml/min GFR is crucial. Monitoring of plasma concentrations may contribute to preventing neurological toxicity of high-dose therapy for this life-threatening condition.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Routine prenatal screening for Down syndrome challenges professional non-directiveness and patient autonomy in daily clinical practices. This paper aims to describe how professionals negotiate their role when a pregnant woman asks them to become involved in the decision-making process implied by screening. METHODS: Forty-one semi-structured interviews were conducted with gynaecologists-obstetricians (n=26) and midwives (n=15) in a large Swiss city. RESULTS: Three professional profiles were constructed along a continuum that defines the relative distance or proximity towards patients' demands for professional involvement in the decision-making process. The first profile insists on enforcing patient responsibility, wherein the healthcare provider avoids any form of professional participation. A second profile defends the idea of a shared decision making between patients and professionals. The third highlights the intervening factors that justify professionals' involvement in decisions. CONCLUSIONS: These results illustrate various applications of the principle of autonomy and highlight the complexity of the doctor-patient relationship amidst medical decisions today.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A liquid chromatography method coupled to mass spectrometry was developed for the quantification of bupropion, its metabolite hydroxy-bupropion, moclobemide, reboxetine and trazodone in human plasma. The validation of the analytical procedure was assessed according to Société Française des Sciences et Techniques Pharmaceutiques and the latest Food and Drug Administration guidelines. The sample preparation was performed with 0.5mL of plasma extracted on a cation-exchange solid phase 96-well plate. The separation was achieved in 14min on a C18 XBridge column (2.1mm×100mm, 3.5μm) using a 50mM ammonium acetate pH 9/acetonitrile mobile phase in gradient mode. The compounds of interest were analysed in the single ion monitoring mode on a single quadrupole mass spectrometer working in positive electrospray ionisation mode. Two ions were selected per molecule to increase the number of identification points and to avoid as much as possible any false positives. Since selectivity is always a critical point for routine therapeutic drug monitoring, more than sixty common comedications for the psychiatric population were tested. For each analyte, the analytical procedure was validated to cover the common range of concentrations measured in plasma samples: 1-400ng/mL for reboxetine and bupropion, 2-2000ng/mL for hydroxy-bupropion, moclobemide, and trazodone. For all investigated compounds, reliable performance in terms of accuracy, precision, trueness, recovery, selectivity and stability was obtained. One year after its implementation in a routine process, this method demonstrated a high robustness with accurate values over the wide concentration range commonly observed among a psychiatric population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

IMPLICATIONS: A new combined ear sensor was tested for accuracy in 20 critically ill children. It provides noninvasive and continuous monitoring of arterial oxygen saturation, arterial carbon dioxide tension, and pulse rate. The sensor proved to be clinically accurate in the tested range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: To investigate if vaginal application of dequalinium chloride (DQC, Fluomizin®) is as effective as vaginal clindamycin (CLM) in the treatment of bacterial vaginosis (BV). METHODS: This was a multinational, multicenter, single-blind, randomized trial in 15 centers, including 321 women. They were randomized to either vaginal DQC tablets or vaginal CLM cream. Follow-up visits were 1 week and 1 month after treatment. Clinical cure based on Amsel's criteria was the primary outcome. Secondary outcomes were rate of treatment failures and recurrences, incidence of post-treatment vulvovaginal candidosis (VVC), lactobacillary grade (LBG), total symptom score (TSC), and safety. RESULTS: Cure rates with DQC (C1: 81.5%, C2: 79.5%) were as high as with CLM (C1: 78.4%, C2: 77.6%). Thus, the treatment with DQC had equal efficacy as CLM cream. A trend to less common post-treatment VVC in the DQC-treated women was observed (DQC: 2.5%, CLM: 7.7%; p = 0.06). Both treatments were well tolerated with no serious adverse events occurring. CONCLUSION: Vaginal DQC has been shown to be equally effective as CLM cream, to be well tolerated with no systemic safety concerns, and is therefore a valid alternative therapy for women with BV [ClinicalTrials.gov, Med380104, NCT01125410].

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A selective and sensitive method was developed for the simultaneous quantification of seven typical antipsychotic drugs (cis-chlorprothixene, flupentixol, haloperidol, levomepromazine, pipamperone, promazine and zuclopenthixol) in human plasma. Ultra-high performance liquid chromatography (UHPLC) was used for complete separation of the compounds in less than 4.5min on an Acquity UPLC BEH C18 column (2.1mm×50mm; 1.7μm), with a gradient elution of ammonium formate buffer pH 4.0 and acetonitrile at a flow rate of 400μl/min. Detection was performed on a tandem quadrupole mass spectrometer (MS/MS) equipped with an electrospray ionization interface. A simple protein precipitation procedure with acetonitrile was used for sample preparation. Thanks to the use of stable isotope-labeled internal standards for all analytes, internal standard-normalized matrix effects were in the range of 92-108%. The method was fully validated to cover large concentration ranges of 0.2-90ng/ml for haloperidol, 0.5-90ng/ml for flupentixol, 1-450ng/ml for levomepromazine, promazine and zuclopenthixol and 2-900ng/ml for cis-chlorprothixene and pipamperone. Trueness (89.1-114.8%), repeatability (1.8-9.9%), intermediate precision (1.9-16.3%) and accuracy profiles (<30%) were in accordance with the latest international recommendations. The method was successfully used in our laboratory for routine quantification of more than 500 patient plasma samples for therapeutic drug monitoring. To the best of our knowledge, this is the first UHPLC-MS/MS method for the quantification of the studied drugs with a sample preparation based on protein precipitation.