213 resultados para precision metrology
Resumo:
OBJECTIVE: Patients with schizophrenia show deficits in visuospatial working memory and visual pursuit processes. It is currently unclear, however, whether both impairments are related to a common neuropathological origin. The purpose of the present study was therefore to examine the possible relations between the encoding and the discrimination of dynamic visuospatial stimuli in schizophrenia. METHOD: Sixteen outpatients with schizophrenia and 16 control subjects were asked to encode complex disc displacements presented on a screen. After a delay, participants had to identify the previously presented disc trajectory from a choice of six static linear paths, among which were five incorrect paths. The precision of visual pursuit eye movements during the initial presentation of the dynamic stimulus was assessed. The fixations and scanning time in definite regions of the six paths presented during the discrimination phase were investigated. RESULTS: In comparison with controls, patients showed poorer task performance, reduced pursuit accuracy during incorrect trials and less time scanning the correct stimulus or the incorrect paths approximating its global structure. Patients also spent less time scanning the leftmost portion of the correct path even when making a correct choice. The accuracy of visual pursuit and head movements, however, was not correlated with task performance. CONCLUSIONS: The present study provides direct support for the hypothesis that active integration of visuospatial information within working memory is deficient in schizophrenia. In contrast, a general impairment of oculomotor mechanisms involved in smooth pursuit did not appear to be directly related to lower visuospatial working memory performance in schizophrenia.
Resumo:
PURPOSE: To examine the impact of spatial resolution and respiratory motion on the ability to accurately measure atherosclerotic plaque burden and to visually identify atherosclerotic plaque composition. MATERIALS AND METHODS: Numerical simulations of the Bloch equations and vessel wall phantom studies were performed for different spatial resolutions by incrementally increasing the field of view. In addition, respiratory motion was simulated based on a measured physiologic breathing pattern. RESULTS: While a spatial resolution of > or = 6 pixels across the wall does not result in significant errors, a resolution of < or = 4 pixels across the wall leads to an overestimation of > 20%. Using a double-inversion T2-weighted turbo spin echo sequence, a resolution of 1 pixel across equally thick tissue layers (fibrous cap, lipid, smooth muscle) and a respiratory motion correction precision (gating window) of three times the thickness of the tissue layer allow for characterization of the different coronary wall components. CONCLUSIONS: We found that measurements in low-resolution black blood images tend to overestimate vessel wall area and underestimate lumen area.
Resumo:
Magnetic resonance imaging (MRI) and spectroscopy (MRS) allow establishing theanatomical evolution and neurochemical profiles of ischemic lesions. However onlylimited MRS studies have been reported to-date in mice due to the challenges ofMRS in small organs. The aim of the current work was to study the neurochemicaland imaging sequelae of ischemic stroke in a mouse model in a horizontal bore14.1 Tesla system.ICR-CD1 mice were subjected to 30 minute transient middle cerebral artery occlusion.The extent of the lesion was determined by MRI. The neurochemical profileconsisting of the concentrations of 22 metabolites was measured longitudinallyfollowing the recovery from ischemia at 3, 8 and 24h in the striatum.Our model produced very reproducible striatal lesions which began to appear onT2-weighted images 8h after ischemia. At 24h, they were well established andtheir size correlated with lesions measured by histology. Profound changes couldbe observed in the neurochemical profiles of the core of the striatal lesions as earlyas 3h post-ischemia, in particular, we observed elevated lactate levels, decreases inthe putative neuronal marker N-acetyl-aspartate and in glutamate, and a transienttwo-fold glutamine increase, likely linked to excitotoxic release of glutamate andconversion to glutamine. With further ischemia evolution, other changes appearedat later time-points, mainly decreases of metabolites, consistent with disruption ofcellular function. It is interesting to note that glutamine tended to return to basallevels at 24h.We conclude that early changes in markers of energy metabolism, glutamate excitotoxicityand neuronal viability can be detected with high precision non-invasively inmice following stroke. Such investigations should lead to a better understanding andinsight into the sequential early changes in the brain parenchyma after ischemia,which could be used e.g. for identifying new targets for neuroprotection.
Resumo:
The aim of this study was to develop an ambulatory system for the three-dimensional (3D) knee kinematics evaluation, which can be used outside a laboratory during long-term monitoring. In order to show the efficacy of this ambulatory system, knee function was analysed using this system, after an anterior cruciate ligament (ACL) lesion, and after reconstructive surgery. The proposed system was composed of two 3D gyroscopes, fixed on the shank and on the thigh, and a portable data logger for signal recording. The measured parameters were the 3D mean range of motion (ROM) and the healthy knee was used as control. The precision of this system was first assessed using an ultrasound reference system. The repeatability was also estimated. A clinical study was then performed on five unilateral ACL-deficient men (range: 19-36 years) prior to, and a year after the surgery. The patients were evaluated with the IKDC score and the kinematics measurements were carried out on a 30 m walking trial. The precision in comparison with the reference system was 4.4 degrees , 2.7 degrees and 4.2 degrees for flexion-extension, internal-external rotation, and abduction-adduction, respectively. The repeatability of the results for the three directions was 0.8 degrees , 0.7 degrees and 1.8 degrees . The averaged ROM of the five patients' healthy knee were 70.1 degrees (standard deviation (SD) 5.8 degrees), 24.0 degrees (SD 3.0 degrees) and 12.0 degrees (SD 6.3 degrees for flexion-extension, internal-external rotation and abduction-adduction before surgery, and 76.5 degrees (SD 4.1 degrees), 21.7 degrees (SD 4.9 degrees) and 10.2 degrees (SD 4.6 degrees) 1 year following the reconstruction. The results for the pathologic knee were 64.5 degrees (SD 6.9 degrees), 20.6 degrees (SD 4.0 degrees) and 19.7 degrees (8.2 degrees) during the first evaluation, and 72.3 degrees (SD 2.4 degrees), 25.8 degrees (SD 6.4 degrees) and 12.4 degrees (SD 2.3 degrees) during the second one. The performance of the system enabled us to detect knee function modifications in the sagittal and transverse plane. Prior to the reconstruction, the ROM of the injured knee was lower in flexion-extension and internal-external rotation in comparison with the controlateral knee. One year after the surgery, four patients were classified normal (A) and one almost normal (B), according to the IKDC score, and changes in the kinematics of the five patients remained: lower flexion-extension ROM and higher internal-external rotation ROM in comparison with the controlateral knee. The 3D kinematics was changed after an ACL lesion and remained altered one year after the surgery
Resumo:
Introduction: Hepatitis E virus (HEV) emerged as an autochthonous food-borne disease in developed countries, transmitted mainly through pork meat. Cases of transmission through blood transfusion have been reported. Recent studies revealed sero-prevalence rates of 13.5%, 16.6% and 20.6% among blood donors in England, France and Denmark, respectively. The aim of this study was to determine the sero-prevalence of HEV among Swiss blood donors. Method: We screened 550 consecutive blood donations from the Service Régional Vaudois de Transfusion Sanguine of Epalinges, for the presence of anti-HEV IgG (MP Diagnostics HEV ELISA). The sample size was based on the Lorentz formula considering an expected prevalence of 3% with a precision of 1.5%. For each donor, we studied the following variables: age, sex and alanine aminotransferase (ALT) value. Results: All blood donors were Caucasian, and included 332 men (60.4%) and 218 women (39.6%). The median age was 55 years (IQR 46-63 years). Overall, anti-HEV IgG were found in 27 of 550 samples (4.9%). The sero-prevalence was 5.4% (18/314) in men and 4.1% (9/209) in women. The presence of anti-HEV IgG was not correlated to age, gender or ALT values. Conclusion: Compared to other European countries, the HEV sero-prevalence among blood donors in Switzerland is surprisingly low. Possible explanations include the strict regulation of animals and meat import. However, to confirm this hypothesis, further studies assessing the prevalence of HEV in Swiss swine will be necessary.
Resumo:
BACKGROUND: PCR has the potential to detect and precisely quantify specific DNA sequences, but it is not yet often used as a fully quantitative method. A number of data collection and processing strategies have been described for the implementation of quantitative PCR. However, they can be experimentally cumbersome, their relative performances have not been evaluated systematically, and they often remain poorly validated statistically and/or experimentally. In this study, we evaluated the performance of known methods, and compared them with newly developed data processing strategies in terms of resolution, precision and robustness. RESULTS: Our results indicate that simple methods that do not rely on the estimation of the efficiency of the PCR amplification may provide reproducible and sensitive data, but that they do not quantify DNA with precision. Other evaluated methods based on sigmoidal or exponential curve fitting were generally of both poor resolution and precision. A statistical analysis of the parameters that influence efficiency indicated that it depends mostly on the selected amplicon and to a lesser extent on the particular biological sample analyzed. Thus, we devised various strategies based on individual or averaged efficiency values, which were used to assess the regulated expression of several genes in response to a growth factor. CONCLUSION: Overall, qPCR data analysis methods differ significantly in their performance, and this analysis identifies methods that provide DNA quantification estimates of high precision, robustness and reliability. These methods allow reliable estimations of relative expression ratio of two-fold or higher, and our analysis provides an estimation of the number of biological samples that have to be analyzed to achieve a given precision.
Resumo:
Genotypic frequencies at codominant marker loci in population samples convey information on mating systems. A classical way to extract this information is to measure heterozygote deficiencies (FIS) and obtain the selfing rate s from FIS = s/(2 - s), assuming inbreeding equilibrium. A major drawback is that heterozygote deficiencies are often present without selfing, owing largely to technical artefacts such as null alleles or partial dominance. We show here that, in the absence of gametic disequilibrium, the multilocus structure can be used to derive estimates of s independent of FIS and free of technical biases. Their statistical power and precision are comparable to those of FIS, although they are sensitive to certain types of gametic disequilibria, a bias shared with progeny-array methods but not FIS. We analyse four real data sets spanning a range of mating systems. In two examples, we obtain s = 0 despite positive FIS, strongly suggesting that the latter are artefactual. In the remaining examples, all estimates are consistent. All the computations have been implemented in a open-access and user-friendly software called rmes (robust multilocus estimate of selfing) available at http://ftp.cefe.cnrs.fr, and can be used on any multilocus data. Being able to extract the reliable information from imperfect data, our method opens the way to make use of the ever-growing number of published population genetic studies, in addition to the more demanding progeny-array approaches, to investigate selfing rates.
Resumo:
OBJECTIVES: To test the validity of a simple, rapid, field-adapted, portable hand-held impedancemeter (HHI) for the estimation of lean body mass (LBM) and percentage body fat (%BF) in African women, and to develop specific predictive equations. DESIGN: Cross-sectional observational study. SETTINGS: Dakar, the capital city of Senegal, West Africa. SUBJECTS: A total sample of 146 women volunteered. Their mean age was of 31.0 y (s.d. 9.1), weight 60.9 kg (s.d. 13.1) and BMI 22.6 kg/m(2) (s.d. 4.5). METHODS: Body composition values estimated by HHI were compared to those measured by whole body densitometry performed by air displacement plethysmography (ADP). The specific density of LBM in black subjects was taken into account for the calculation of %BF from body density. RESULTS: : Estimations from HHI showed a large bias (mean difference) of 5.6 kg LBM (P<10(-4)) and -8.8 %BF (P<10(-4)) and errors (s.d. of the bias) of 2.6 kg LBM and 3.7 %BF. In order to correct for the bias, specific predictive equations were developed. With the HHI result as a single predictor, error values were of 1.9 kg LBM and 3.7 %BF in the prediction group (n=100), and of 2.2 kg LBM and 3.6 %BF in the cross-validation group (n=46). Addition of anthropometrical predictors was not necessary. CONCLUSIONS: The HHI analyser significantly overestimated LBM and underestimated %BF in African women. After correction for the bias, the body compartments could easily be estimated in African women by using the HHI result in an appropriate prediction equation with a good precision. It remains to be seen whether a combination of arm and leg impedancemetry in order to take into account lower limbs would further improve the prediction of body composition in Africans.
Resumo:
INTRODUCTION: Focal therapy may reduce the toxicity of current radical treatments while maintaining the oncological benefit. Irreversible electroporation (IRE) has been proposed to be tissue selective and so might have favourable characteristics compared to the currently used prostate ablative technologies. The aim of this trial is to determine the adverse events, genito-urinary side effects and early histological outcomes of focal IRE in men with localised prostate cancer. METHODS: This is a single centre prospective development (stage 2a) study following the IDEAL recommendations for evaluating new surgical procedures. Twenty men who have MRI-visible disease localised in the anterior part of the prostate will be recruited. The sample size permits a precision estimate around key functional outcomes. Inclusion criteria include PSA ≤ 15 ng/ml, Gleason score ≤ 4 + 3, stage T2N0M0 and absence of clinically significant disease outside the treatment area. Treatment delivery will be changed in an adaptive iterative manner so as to allow optimisation of the IRE protocol. After focal IRE, men will be followed during 12 months using validated patient reported outcome measures (IPSS, IIEF-15, UCLA-EPIC, EQ-5D, FACT-P, MAX-PC). Early disease control will be evaluated by mpMRI and targeted transperineal biopsy of the treated area at 6 months. DISCUSSION: The NEAT trial will assess the early functional and disease control outcome of focal IRE using an adaptive design. Our protocol can provide guidance for designing an adaptive trial to assess new surgical technologies in the challenging landscape of health technology assessment in prostate cancer treatment.
Resumo:
In this communication we introduce a low or reduced coherence interferometry technique that can be used to retrieve surface topology on samples with high roughness. Moreover, we will show that the approach enables surface topology measurement also at the interface of so-called turbid media, where multiple scattering inside tissues can be a major issue, preventing accurate measurements.
Resumo:
OBJECTIVE: Cuff inflation at the arm is known to cause an instantaneous rise in blood pressure, which might be due to the discomfort of the procedure and might interfere with the precision of the blood pressure measurement. In this study, we compared the reactive rise in blood pressure induced by cuff inflation when the cuff was placed at the upper arm level and at the wrist. PARTICIPANTS AND METHODS: The reactive rise in systolic and diastolic blood pressure to cuff inflation was measured in 34 normotensive participants and 34 hypertensive patients. Each participant was equipped with two cuffs, one around the right upper arm (OMRON HEM-CR19, 22-32 cm) and one around the right wrist (OMRON HEM-CS 19, 17-22 cm; Omron Health Care Europe BV, Hoofddorp, The Netherlands). The cuffs were inflated in a double random order (maximal cuff pressure and position of the cuff) with two maximal cuff pressures: 180 and 240 mmHg. The cuffs were linked to an oscillometric device (OMRON HEM 907; Omron Health Care). Simultaneously, blood pressure was measured continuously at the middle finger of the left hand using photoplethysmography. Three measurements were made at each level of blood pressure at the arm and at the wrist, and the sequence of measurements was randomized. RESULTS: In normotensive participants, no significant difference was observed in the reactive rise in blood pressure when the cuff was inflated either at the arm or at the wrist irrespective of the level of cuff inflation. Inflating a cuff at the arm, however, induced a significantly greater rise in blood pressure than inflating it at the wrist in hypertensive participants for both systolic and diastolic pressures (P<0.01), and at both levels of cuff inflation. The blood pressure response to cuff inflation was independent of baseline blood pressure. CONCLUSIONS: The results show that in hypertensive patients, cuff inflation at the wrist produces a smaller reactive rise in blood pressure. The difference between the arm and the wrist is independent of the patient's level of blood pressure.
Resumo:
A transportable, whole body indirect calorimeter, designed for use in the tropics, is described. The calorimeter was built to study energy expenditure of people having chronically or acutely low levels of food intake, and it will help to determine energy adaptations made by individuals with restricted food intake. The calorimeter comprises two units: a 27 m3 ventilated chamber connected to an office housing control and monitoring equipment. The system also allows the experimenter to assess the rate of energy expenditure by means of a ventilated hood or a baby respiration chamber. The incoming air flow rate is variable and is typically set at approximately 30 l/min. Carbon dioxide production (VCO2) and oxygen consumption (VO2) are continuously monitored by means of differential gas analysers via a computerized data acquisition unit. Gas production/consumption rates are measured with a delay of 80 s, the complete response to step changes in VCO2 or VO2 consumption being calculated over 15 min using the rate of change terms in the gas exchange equations. The total electrical power required for the whole system is 12 kW. The calorimeter has been functioning for nearly 4 years in a rural village of The Gambia during which ambient temperatures have ranged from 16 to 44 degrees C and dewpoints from -8 to 24 degrees C. The performance and accuracy of the calorimeter were tested using 20 per cent CO2 in N2 infusion and butane burning. Agreement between the theoretical and the measured values was found to be 99 per cent for VO2 and 100 per cent for VCO2 with a precision for both gases of +/- 10 ml/min over a 1-h period.
Resumo:
Understanding the emplacement and growth of intrusive bodies in terms of mechanism, duration, ther¬mal evolution and rates are fundamental aspects of crustal evolution. Recent studies show that many plutons grow in several Ma by in situ accretion of discrete magma pulses, which constitute small-scale magmatic reservoirs. The residence time of magmas, and hence their capacities to interact and differentiate, are con¬trolled by the local thermal environment. The latter is highly dependant on 1) the emplacement depth, 2) the magmas and country rock composition, 3) the country rock thermal conductivity, 4) the rate of magma injection and 5) the geometry of the intrusion. In shallow level plutons, where magmas solidify quickly, evi¬dence for magma mixing and/or differentiation processes is considered by many authors to be inherited from deeper levels. This work shows however that in-situ differentiation and magma interactions occurred within basaltic and felsic sills at shallow depth (0.3 GPa) in the St-Jean-du-Doigt (SJDD) bimodal intrusion, France. This intrusion emplaced ca. 347 Ma ago (IDTIMS U/Pb on zircon) in the Precambrian crust of the Armori- can massif and preserves remarkable sill-like emplacement processes of bimodal mafic-felsic magmas. Field evidence coupled to high precision zircon U-Pb dating document progressive thermal maturation within the incrementally built ioppolith. Early m-thick mafic sills (eastern part) form the roof of the intrusion and are homogeneous and fine-grained with planar contacts with neighboring felsic sills; within a minimal 0.8 Ma time span, the system gets warmer (western part). Sills are emplaced by under-accretion under the old east¬ern part, interact and mingle. A striking feature of this younger, warmer part is in-situ differentiation of the mafic sills in the top 40 cm of the layer, which suggests liquids survival in the shallow crust. Rheological and thermal models were performed in order to determine the parameters required to allow this observed in- situ differentiation-accumulation processes. Strong constraints such as total emplacement durations (ca. 0.8 Ma, TIMS date) and pluton thickness (1.5 Km, gravity model) allow a quantitative estimation of the various parameters required (injection rates, incubation time,...). The results show that in-situ differentiation may be achieved in less than 10 years at such shallow depth, provided that: (1) The differentiating sills are injected beneath consolidated, yet still warm basalt sills, which act as low conductive insulating screens (eastern part formation in the SJDD intrusion). The latter are emplaced in a very short time (800 years) at high injection rate (0.5 m/y) in order to create a "hot zone" in the shallow crust (incubation time). This implies that nearly 1/3 of the pluton (400m) is emplaced by a subsequent and sustained magmatic activity occurring on a short time scale at the very beginning of the system. (2) Once incubation time is achieved, the calculations show that a small hot zone is created at the base of the sill pile, where new injections stay above their solidus T°C and may interact and differentiate. Extraction of differentiated residual liquids might eventually take place and mix with newly injected magma as documented in active syn-emplacement shear-zones within the "warm" part of the pluton. (3) Finally, the model show that in order to maintain a permanent hot zone at shallow level, injection rate must be of 0.03 m/y with injection of 5m thick basaltic sills eveiy 130yr, imply¬ing formation of a 15 km thick pluton. As this thickness is in contradiction with the one calculated for SJDD (1.5 Km) and exceed much the average thickness observed for many shallow level plutons, I infer that there is no permanent hot zone (or magma chambers) at such shallow level. I rather propose formation of small, ephemeral (10-15yr) reservoirs, which represent only small portions of the final size of the pluton. Thermal calculations show that, in the case of SJDD, 5m thick basaltic sills emplaced every 1500 y, allow formation of such ephemeral reservoirs. The latter are formed by several sills, which are in a mushy state and may interact and differentiate during a short time.The mineralogical, chemical and isotopic data presented in this study suggest a signature intermediate be¬tween E-MORB- and arc-like for the SJDD mafic sills and feeder dykes. The mantle source involved produced hydrated magmas and may be astenosphere modified by "arc-type" components, probably related to a sub¬ducting slab. Combined fluid mobile/immobile trace elements and Sr-Nd isotopes suggest that such subduc¬tion components are mainly fluids derived from altered oceanic crust with minor effect from the subducted sediments. Close match between the SJDD compositions and BABB may point to a continental back-arc setting with little crustal contamination. If so, the SjDD intrusion is a major witness of an extensional tectonic regime during the Early-Carboniferous, linked to the subduction of the Rheno-Hercynian Ocean beneath the Variscan terranes. Also of interest is the unusual association of cogenetic (same isotopic compositions) K-feldspar A- type granite and albite-granite. A-type granites may form by magma mixing between the mafic magma and crustal melts. Alternatively, they might derive from the melting of a biotite-bearing quartz-feldspathic crustal protolith triggered by early mafic injections at low crustal levels. Albite-granite may form by plagioclase cu¬mulate remelting issued from A-type magma differentiation.
Resumo:
ABSTRACT Adult neuronal plasticity is a term that corresponds to a set of biological mechanisms allowing a neuronal circuit to respond and adapt to modifications of the received inputs. Mystacial whiskers of the mouse are the starting point of a major sensory pathway that provides the animal with information from its immediate environment. Through whisking, information is gathered that allows the animal to orientate itself and to recognize objects. This sensory system is crucial for nocturnal behaviour during which vision is not of much use. Sensory information of the whiskers are sent via brainstem and thalamus to the primary somatosensory area (S1) of the cerebral cortex in a strictly topological manner. Cell bodies in the layer N of S 1 are arranged in ring forming structures called barrels. As such, each barrel corresponds to the cortical representation in layer IV of a single whisker follicle. This histological feature allows to identify with uttermost precision the part of the cortex devoted to a given whisker and to study modifications induced by different experimental conditions. The condition used in the studies of my thesis is the passive stimulation of one whisker in the adult mouse for a period of 24 hours. It is performed by glueing a piece of metal on one whisker and placing the awake animal in a cage surrounded by an electromagnetic coil that generates magnetic field burst inducing whisker movement at a given frequency during 24 hours. I analysed the ultrastructure of the barrel corresponding the stimulated whisker using serial sections electron microscopy and computer-based three-dimensional reconstructions; analysis of neighbouring, unstimulated barrels as well as those from unstimulated mice served as control. The following elements were structurally analyzed: the spiny dendrites, the axons of excitatory as well as inhibitory cells, their connections via synapses and the astrocytic processes. The density of synapses and spines is upregulated in a barrel corresponding to a stimulated whisker. This upregulation is absent in the BDNF heterozygote mice, indicating that a certain level of activity-dependent released BDNF is required for synaptogenesis in the adult cerebral cortex. Synpaptogenesis is correlated with a modification of the astrocytes that place themselves in closer vicinity of the excitatory synapses on spines. Biochemical analysis revealed that the astrocytes upregulate the expression of transporters by which they internalise glutamate, the neurotransmitter responsible for the excitatory response of cortical neurons. In the final part of my thesis, I show that synaptogenesis in the stimulated barrel is due to the increase in the size of excitatory axonal boutons that become more frequently multisynaptic, whereas the inhibitory axons do not change their morphology but form more synapses with spines apposed to them. Taken together, my thesis demonstrates that all the cellular elements present in the neuronal tissue of the adult brain contribute to activity-dependent cortical plasticity and form part of a mechanism by which the animal responds to a modified sensory experience. Throughout life, the neuronal circuit keeps the faculty to adapt its function. These adaptations are partially transitory but some aspects remain and could be the structural basis of a memory trace in the cortical circuit. RESUME La plasticité neuronale chez l'adulte désigne un ensemble de mécanismes biologiques qui permettent aux circuits neuronaux de répondre et de s'adapter aux modifications des stimulations reçues. Les vibrisses des souris sont un système crucial fournissant des informations sensorielles au sujet de l'environnement de l'animal. L'information sensorielle collectée par les vibrisses est envoyée via le tronc cérébral et le thalamus à l'aire sensorielle primaire (S 1) du cortex cérébral en respectant strictement la somatotopie. Les corps cellulaires dans la couche IV de S 1 sont organisés en anneaux délimitant des structures nommées tonneaux. Chaque tonneau reçoit l'information d'une seule vibrisse et l'arrangement des tonneaux dans le cortex correspond à l'arrangement des vibrisses sur le museau de la souris. Cette particularité histologique permet de sélectionner avec certitude la partie du cortex dévolue à une vibrisse et de l'étudier dans diverses conditions. Le paradigme expérimental utilisé dans cette thèse est la stimulation passive d'une seule vibrisse durant 24 heures. Pour ce faire, un petit morceau de métal est collé sur une vibrisse et la souris est placée dans une cage entourée d'une bobine électromagnétique générant un champ qui fait vibrer le morceau de métal durant 24 heures. Nous analysons l'ultrastructure du cortex cérébral à l'aide de la microscopie électronique et des coupes sériées permettant la reconstruction tridimensionnelle à l'aide de logiciels informatiques. Nous observons les modifications des structures présentes : les dendrites épineuses, les axones des cellules excitatrices et inhibitrices, leurs connections par des synapses et les astrocytes. Le nombre de synapses et d'épines est augmenté dans un tonneau correspondant à une vibrisse stimulée 24 heures. Basé sur cela, nous montrons dans ces travaux que cette réponse n'est pas observée dans des souris hétérozygotes BDNF+/-. Cette neurotrophine sécrétée en fonction de l'activité neuronale est donc nécessaire pour la synaptogenèse. La synaptogenèse est accompagnée d'une modification des astrocytes qui se rapprochent des synapses excitatrices au niveau des épines dendritiques. Ils expriment également plus de transporteurs chargés d'internaliser le glutamate, le neurotransmetteur responsable de la réponse excitatrice des neurones. Nous montrons aussi que les axones excitateurs deviennent plus larges et forment plus de boutons multi-synaptiques à la suite de la stimulation tandis que les axones inhibiteurs ne changent pas de morphologie mais forment plus de synapses avec des épines apposées à leur membrane. Tous les éléments analysés dans le cerveau adulte ont maintenu la capacité de réagir aux modifications de l'activité neuronale et répondent aux modifications de l'activité permettant une constante adaptation à de nouveaux environnements durant la vie. Les circuits neuronaux gardent la capacité de créer de nouvelles synapses. Ces adaptations peuvent être des réponses transitoires aux stimuli mais peuvent aussi laisser une trace mnésique dans les circuits.
Resumo:
This study aimed to compare O2 consumption (VO2) determination by the gas-exchange (VO2GE) and Fick (VO2F) methods in cardiac surgical patients. A total of 10 mechanically ventilated postoperative patients were studied prospectively. Thermodilution was performed using three randomly applied techniques: room temperature saline injected at end expiration, room temperature saline randomly injected in the respiratory cycle, and iced saline injected at end expiration. The influence of the number of thermodilution determinations was assessed by comparing results from 2 and 10 injections. The variability of VO2F was greater than that of VO2GE. There was no bias between VO2GE and VO2F values using injectate at room temperature. Accuracy and precision were not improved by increasing the number of cardiac output determinations from 2 to 10. A significant bias was observed using ice-cold injectate, VO2F being 18.0 +/- 15.4 ml/min/m2 lower than VO2GE (p = 0.001). Published results when comparing VO2F and VO2GE are discrepant. However, a significant bias was found in all studies using cold injectate, with lower VO2F values. We conclude that iced injectate should not be used to assess VO2 in critically ill patients.