184 resultados para Tagged Mri
Resumo:
PURPOSE: The aim of this study was to systematically compare a comprehensive array of magnetic resonance (MR) imaging features in terms of their sensitivity and specificity to diagnose cervical lymph node metastases in patients with thyroid cancer. MATERIALS AND METHODS: The study included 41 patients with thyroid malignancy who underwent surgical excision of cervical lymph nodes and had preoperative MR imaging ≤4weeks prior to surgery. Three head and neck neuroradiologists independently evaluated all the MR images. Using the pathology results as reference, the sensitivity, specificity and interobserver agreement of each MR imaging characteristic were calculated. RESULTS: On multivariate analysis, no single imaging feature was significantly correlated with metastasis. In general, imaging features demonstrated high specificity, but poor sensitivity and moderate interobserver agreement at best. CONCLUSIONS: Commonly used MR imaging features have limited sensitivity at correctly identifying cervical lymph node metastases in patients with thyroid cancer. A negative neck MR scan should not dissuade a surgeon from performing a neck dissection in patients with thyroid carcinomas.
Resumo:
The advent of multiparametric MRI has made it possible to change the way in which prostate biopsy is done, allowing to direct biopsies to suspicious lesions rather than randomly. The subject of this review relates to a computer-assisted strategy, the MRI/US fusion software-based targeted biopsy, and to its performance compared to the other sampling methods. Different devices with different methods to register MR images to live TRUS are currently in use to allow software-based targeted biopsy. Main clinical indications of MRI/US fusion software-based targeted biopsy are re-biopsy in men with persistent suspicious of prostate cancer after first negative standard biopsy and the follow-up of patients under active surveillance. Some studies have compared MRI/US fusion software-based targeted versus standard biopsy. In men at risk with MRI-suspicious lesion, targeted biopsy consistently detects more men with clinically significant disease as compared to standard biopsy; some studies have also shown decreased detection of insignificant disease. Only two studies directly compared MRI/US fusion software-based targeted biopsy with MRI/US fusion visual targeted biopsy, and the diagnostic ability seems to be in favor of the software approach. To date, no study comparing software-based targeted biopsy against in-bore MRI biopsy is available. The new software-based targeted approach seems to have the characteristics to be added in the standard pathway for achieving accurate risk stratification. Once reproducibility and cost-effectiveness will be verified, the actual issue will be to determine whether MRI/TRUS fusion software-based targeted biopsy represents anadd-on test or a replacement to standard TRUS biopsy.
Resumo:
Introduction: Gamma Knife surgery (GKS) is a noninvasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes the targeting of the ventrointermediate nucleus of the thalamus (e.g., Vim) for tremor. Objective: To enhance anatomic imaging for Vim GKS using high-field (7 T) MRI and Diffusion Weighted Imaging (DWI). Methods: Five young healthy subjects and two patients were scanned both on 3 and 7 T MRI. The protocol was the same in all cases, and included: T1-weighted (T1w) and DWI at 3T; susceptibility weighted images (SWI) at 7T for the visualization of thalamic subparts. SWI was further integrated into the Gamma Plan Software® (LGP, Elekta Instruments, AB, Sweden) and co-registered with 3T images. A simulation of targeting of the Vim was done using the quadrilatere of Guyot. Furthermore, a correlation with the position of the found target on SWI and also on DWI (after clustering of the different thalamic nuclei) was performed. Results: For the 5 healthy subjects, there was a good correlation between the position of the Vim on SWI, DWI and the GKS targeting. For the patients, on the pretherapeutic acquisitions, SWI helped in positioning the target. For posttherapeutic sequences, SWI supposed position of the Vim matched the corresponding contrast enhancement seen at follow-up MRI. Additionally, on the patient's follow-up T1w images, we could observe a small area of contrast-enhancement corresponding to the target used in GKS (e.g., Vim), which belongs to the Ventral-Lateral-Ventral (VLV) nuclei group. Our clustering method resulted in seven thalamic groups. Conclusion: The use of SWI provided us with a superior resolution and an improved image contrast within the central gray matter, enabling us to directly visualize the Vim. We additionally propose a novel robust method for segmenting the thalamus in seven anatomical groups based on DWI. The localization of the GKS target on the follow-up T1w images, as well as the position of the Vim on 7 T, have been used as a gold standard for the validation of VLV cluster's emplacement. The contrast enhancement corresponding to the targeted area was always localized inside the expected cluster, providing strong evidence of the VLV segmentation accuracy. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T (e.g., quadrilatere of Guyot, histological atlases, DWI) seems to show a very good anatomical matching.
Resumo:
Whole-body coverage using MRI was developed almost 2 decades ago. The first applications focused on the investigation of the skeleton to detect neoplastic disease, mainly metastases from solid cancers, and involvement by multiple myeloma and lymphoma. But the extensive coverage of the whole musculoskeletal system, combined with the exquisite sensitivity of MRI to tissue alteration in relation to different pathologic conditions, mainly inflammation, has led to the identification of a growing number of indications outside oncology. Seronegative rheumatisms, systemic sclerosis, inflammatory diseases involving muscles or fascias, and multifocal osseous, vascular, or neurologic diseases represent currently validated or emerging indications of whole-body MRI (WB-MRI). We first illustrate the most valuable indications of WB-MRI in seronegative rheumatisms that include providing significant diagnostic information in patients with negative or ambiguous MRI of the sacroiliac joints and the lumbar spine, assessing disease activity in advanced (ankylosed) central disease, and evaluating the peripherally dominant forms of spondyloarthropathy. Then we review the increasing indications of WB-MRI in other rheumatologic and nonneoplastic disorders, underline the clinical needs, and illustrate the role of WB-MRI in the positive diagnosis and evaluation of disease burden, therapeutic decisions, and treatment monitoring.
Resumo:
Fetal MRI reconstruction aims at finding a high-resolution image given a small set of low-resolution images. It is usually modeled as an inverse problem where the regularization term plays a central role in the reconstruction quality. Literature has considered several regularization terms s.a. Dirichlet/Laplacian energy [1], Total Variation (TV)based energies [2,3] and more recently non-local means [4]. Although TV energies are quite attractive because of their ability in edge preservation, standard explicit steepest gradient techniques have been applied to optimize fetal-based TV energies. The main contribution of this work lies in the introduction of a well-posed TV algorithm from the point of view of convex optimization. Specifically, our proposed TV optimization algorithm for fetal reconstruction is optimal w.r.t. the asymptotic and iterative convergence speeds O(1/n(2)) and O(1/root epsilon), while existing techniques are in O(1/n) and O(1/epsilon). We apply our algorithm to (1) clinical newborn data, considered as ground truth, and (2) clinical fetal acquisitions. Our algorithm compares favorably with the literature in terms of speed and accuracy.
Resumo:
We consider the problem of multiple correlated sparse signals reconstruction and propose a new implementation of structured sparsity through a reweighting scheme. We present a particular application for diffusion Magnetic Resonance Imaging data and show how this procedure can be used for fibre orientation reconstruction in the white matter of the brain. In that framework, our structured sparsity prior can be used to exploit the fundamental coherence between fibre directions in neighbour voxels. Our method approaches the ℓ0 minimisation through a reweighted ℓ1-minimisation scheme. The weights are here defined in such a way to promote correlated sparsity between neighbour signals.
Resumo:
In diffusion MRI, traditional tractography algorithms do not recover truly quantitative tractograms and the structural connectivity has to be estimated indirectly by counting the number of fiber tracts or averaging scalar maps along them. Recently, global and efficient methods have emerged to estimate more quantitative tractograms by combining tractography with local models for the diffusion signal, like the Convex Optimization Modeling for Microstructure Informed Tractography (COMMIT) framework. In this abstract, we show the importance of using both (i) proper multi-compartment diffusion models and (ii) adequate multi-shell acquisitions, in order to evaluate the accuracy and the biological plausibility of the tractograms.
Resumo:
PURPOSE: Prostate cancer (PCa) diagnosis relies on clinical suspicion leading to systematic transrectal ultrasound-guided biopsy (TRUSGB). Multiparametric magnetic resonance imaging (mpMRI) allows for targeted biopsy of suspicious areas of the prostate instead of random 12-core biopsy. This method has been shown to be more accurate in detecting significant PCa. However, the precise spatial accuracy of cognitive targeting is unknown. METHODS: Consecutive patients undergoing mpMRI-targeted TRUSGB with cognitive registration (MRTB-COG) followed by robot-assisted radical prostatectomy were included in the present analysis. The regions of interest (ROIs) involved by the index lesion reported on mpMRI were subsequently targeted by two experienced urologists using the cognitive approach. The 27 ROIs were used as spatial reference. Mapping on radical prostatectomy specimen was used as reference to determine true-positive mpMRI findings. Per core correlation analysis was performed. RESULTS: Forty patients were included. Overall, 40 index lesions involving 137 ROIs (mean ROIs per index lesion 3.43) were identified on MRI. After correlating these findings with final pathology, 117 ROIs (85 %) were considered as true-positive lesions. A total of 102 biopsy cores directed toward such true-positive ROIs were available for final analysis. Cognitive targeted biopsy hit the target in 82 % of the cases (84/102). The only identified risk factor for missing the target was an anterior situated ROI (p = 0.01). CONCLUSION: In experienced hands, cognitive MRTB-COG allows for an accuracy of 82 % in hitting the correct target, given that it is a true-positive lesion. Anterior tumors are less likely to be successfully targeted.
Resumo:
Connectivity analysis on diffusion MRI data of the whole- brain suffers from distortions caused by the standard echo- planar imaging acquisition strategies. These images show characteristic geometrical deformations and signal destruction that are an important drawback limiting the success of tractography algorithms. Several retrospective correction techniques are readily available. In this work, we use a digital phantom designed for the evaluation of connectivity pipelines. We subject the phantom to a âeurooetheoretically correctâeuro and plausible deformation that resembles the artifact under investigation. We correct data back, with three standard methodologies (namely fieldmap-based, reversed encoding-based, and registration- based). Finally, we rank the methods based on their geometrical accuracy, the dropout compensation, and their impact on the resulting connectivity matrices.
Resumo:
In fetal brain MRI, most of the high-resolution reconstruction algorithms rely on brain segmentation as a preprocessing step. Manual brain segmentation is however highly time-consuming and therefore not a realistic solution. In this work, we assess on a large dataset the performance of Multiple Atlas Fusion (MAF) strategies to automatically address this problem. Firstly, we show that MAF significantly increase the accuracy of brain segmentation as regards single-atlas strategy. Secondly, we show that MAF compares favorably with the most recent approach (Dice above 0.90). Finally, we show that MAF could in turn provide an enhancement in terms of reconstruction quality.