235 resultados para Satisfaction measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Ankle sprains affect 200'000 persons/year in Switzerland. Most incidences are successfully treated by conservative measures but 20% require reconstruction for symptomatic chronic lateral ankle instability. This study evaluates the functional outcome after a modified Broström-Gould technique as measured by different clinical scores and compares the functional outcome of this technique with other surgical treatments of ankle instability. Methods: This retrospective cohort study evaluates 47 patients who underwent a modified Broström-Gould procedure using suture anchors to refix the lateral ankle capsuloligamentary structures at our institution from 2005 to 2009 with a minimum follow-up of one year (13-72 Mo). All patients were operated by one single surgeon and evaluated by an independent examiner. The function was assessed using 4 scores including: the AOFAS (American Orthopaedic Foot and Ankle Society's Score) hindfoot score; the FAAM (Foot and Ankle Ability Measurement); the CAIT (Cumberland Ankle Instability Tool); the CAIS (Chronic Ankle Instability Scale). Results: Six patients were excluded leaving 41 patients for examination. 34 patients (83%) thought that their ankle was more stable after the surgery, 7 (17%) did not feel any difference. 27 patients were very satisfied, 11 satisfied and 3 not satisfied. Reasons for non satisfaction included persistent instability and pain. Ankle mobility returned to normal in 93% of patients. Five patients had transcient hypoesthesy in the area of the superficial peroneal nerve. One patient suffered from a superficial infection treated successfully by local measures. 80% had the perception of a normal ankle, 20% thought to be below normal. At follow-up the AOFAS was 89/100 (37-100), the FAAM 85/100% (35-100%), the CAIT 20/30 (5-30), and the CAIS 74/100% (27-100%). Conclusions: The modified Broström-Gould procedure, which belongs to the anatomic ankle stabilizations is relatively simple and offers good outcome that satisfied 93% of the patients in the present study. No active stabilisator is sacrificed. Preservation of the ankle mobility is better and the complication rate is lower than after non-anatomical procedures described in the literature. The CAIT appeared as the most severe score compared to the other scales used in our study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this work is to study the influence of several analytical parameters on the variability of Raman spectra of paint samples. In the present study, microtome thin section and direct (no preparation) analysis are considered as sample preparation. In order to evaluate their influence on the measures, an experimental design such as 'fractional full factorial' with seven factors (including the sampling process) is applied, for a total of 32 experiments representing 160 measures. Once the influence of sample preparation highlighted, a depth profile of a paint sample is carried out by changing the focusing plane in order to measure the colored layer under a clearcoat. This is undertaken in order to avoid sample preparation such a microtome sectioning. Finally, chemometric treatments such as principal component analysis are applied to the resulting spectra. The findings of this study indicate the importance of sample preparation, or more specifically, the surface roughness, on the variability of the measurements on a same sample. Moreover, the depth profile experiment highlights the influence of the refractive index of the upper layer (clearcoat) when measuring through a transparent layer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Ulnar nerve decompression at the elbow traditionally requires regional or general anesthesia. We wished to assess the feasibility of performing ulnar nerve decompression and transposition at the elbow under local anesthesia. Methods We examined retrospectively the charts of 50 consecutive patients having undergone ulnar nerve entrapment surgery either under general or local anesthesia. Patients were asked to estimate pain on postoperative days 1 and 7 and satisfaction was assessed at 1 year. Results On day 1, pain was comparable among all groups. On day 7, pain scores were twice as high when transposition was performed under general anesthesia when compared with local anesthesia. Patient satisfaction was slightly increased in the local anesthesia group. These patients were significantly more willing to repeat the surgery. Conclusion Ulnar nerve decompression and transposition at the elbow can be performed under local anesthesia without added morbidity when compared with general anesthesia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this communication we introduce a low or reduced coherence interferometry technique that can be used to retrieve surface topology on samples with high roughness. Moreover, we will show that the approach enables surface topology measurement also at the interface of so-called turbid media, where multiple scattering inside tissues can be a major issue, preventing accurate measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Endothelin-1 is an endothelium-derived potent vasoconstrictor peptide of 21 amino acids. To establish reference values in different models of hypertension and in human subjects an assay for plasma immunoreactive endothelin-1 (ET-1) was optimized. METHODS: ET-1 is extracted by acetone from 1 mL of plasma and subjected to a sensitive enzyme-linked immunosorbent assay. RESULTS: The detection limit for plasma ET-1 is 0.05 fmol/mL. Mean recoveries of the 1, 2, 5, and 10 fmol of ET-1 added to 1 mL of plasma were 66%, 75%, 85%, and 92%, respectively. Within- and between-assay coefficients of variation were < or =12% and < or =10%, respectively. Assay accuracy was demonstrated by consistent recoveries of added ET-1 over the entire physiologic range of plasma concentrations and by the linearity of ET-1 concentrations measured in serially diluted plasma extracts (r = 0.99). No ET-1 was detected when albumin buffer was extracted instead of plasma. Using this method, we found increased ET-1 levels in plasma of three experimental rat models of hypertension: stroke prone spontaneously hypertensive rats (SP-SHR), deoxycorticosterone acetate-salt hypertensive rats, and one kidney-one clip hypertensive rats. In contrast, plasma ET-1 levels of SHR were half those of normotensive Wistar rats. In two kidney-one clip hypertensive rats, plasma ET-1 concentrations were not different from those found in sham-operated control rats. Plasma ET-1 concentrations of 37 healthy men were 0.85 +/- 0.26 fmol/ml (mean +/- SD). CONCLUSIONS: The present assay reliably measures ET-1 levels in rat and human plasma. It allows to discriminate between different forms of hypertension with high or low circulating levels of ET-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of our study was to provide an innovative HS-GC/MS method applicable to the routine determination of butane concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature concerning butane measurement was the absence of a specific butane internal standard necessary to perform quantification. Because no stable isotope of butane is commercially available, it is essential to develop a new approach by an in situ generation of standards. To avoid the manipulation of a stable isotope-labelled gas, we have chosen to generate in situ an internal labelled standard gas (C(4)H(9)D) following the basis of the stoichiometric formation of butane by the reaction of deuterated water (D(2)O) with Grignard reagent butylmagnesium chloride (C(4)H(9)MgCl). This method allows a precise measurement of butane concentration and therefore, a full validation by accuracy profile was presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ambulatory blood pressure monitoring (ABPM) has become indispensable for the diagnosis and control of hypertension. However, no consensus exists on how daytime and nighttime periods should be defined. OBJECTIVE: To compare daytime and nighttime blood pressure (BP) defined by an actigraph and by body position with BP resulting from arbitrary daytime and nighttime periods. PATIENTS AND METHOD: ABPM, sleeping periods and body position were recorded simultaneously using an actigraph (SenseWear Armband(®)) in patients referred for ABPM. BP results obtained with the actigraph (sleep and position) were compared to the results obtained with fixed daytime (7a.m.-10p.m.) and nighttime (10p.m.-7a.m.) periods. RESULTS: Data from 103 participants were available. More than half of them were taking antihypertensive drugs. Nocturnal BP was lower (systolic BP: 2.08±4.50mmHg; diastolic BP: 1.84±2.99mmHg, P<0.05) and dipping was more marked (systolic BP: 1.54±3.76%; diastolic BP: 2.27±3.48%, P<0.05) when nighttime was defined with the actigraph. Standing BP was higher (systolic BP 1.07±2.81mmHg; diastolic BP: 1.34±2.50mmHg) than daytime BP defined by a fixed period. CONCLUSION: Diurnal BP, nocturnal BP and dipping are influenced by the definition of daytime and nighttime periods. Studies evaluating the prognostic value of each method are needed to clarify which definition should be used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the application of a real-time quantitative PCR assay, previously developed to measure relative telomere length in humans and mice, to two bird species, the zebra finch Taeniopygia guttata and the Alpine swift Apus melba. This technique is based on the PCR amplification of telomeric (TTAGGG)(n) sequences using specific oligonucleotide primers. Relative telomere length is expressed as the ratio (T/S) of telomere repeat copy number (T) to control single gene copy number (S). This method is particularly useful for comparisons of individuals within species, or where the same individuals are followed longitudinally. We used glyceraldehyde-3-phosphate dehydrogenase (GAPDH) as a single control gene. In both species, we validated our PCR measurements of relative telomere length against absolute measurements of telomere length determined by the conventional method of quantifying telomere terminal restriction fragment (TRF) lengths using both the traditional Southern blot analysis (Alpine swifts) and in gel hybridization (zebra finches). As found in humans and mice, telomere lengths in the same sample measured by TRF and PCR were well correlated in both the Alpine swift and the zebra finch.. Hence, this PCR assay for measurement of bird telomeres, which is fast and requires only small amounts of genomic DNA, should open new avenues in the study of environmental factors influencing variation in telomere length, and how this variation translates into variation in cellular and whole organism senescence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Self-measurement of blood pressure at home is increasingly used in the diagnostic and therapeutic approach of hypertension. This technique allows multiple measurements of blood pressure away from the clinical setting, making it possible to improve the evaluation of cardiovascular risk. Recently new guidelines on the use of self-measured blood pressure have been made available by the European Society of Hypertension, as summarized in the present paper.