254 resultados para Image promotion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Remote sensing image processing is nowadays a mature research area. The techniques developed in the field allow many real-life applications with great societal value. For instance, urban monitoring, fire detection or flood prediction can have a great impact on economical and environmental issues. To attain such objectives, the remote sensing community has turned into a multidisciplinary field of science that embraces physics, signal theory, computer science, electronics, and communications. From a machine learning and signal/image processing point of view, all the applications are tackled under specific formalisms, such as classification and clustering, regression and function approximation, image coding, restoration and enhancement, source unmixing, data fusion or feature selection and extraction. This paper serves as a survey of methods and applications, and reviews the last methodological advances in remote sensing image processing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO(TM) is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. OBJECTIVE: To evaluate the potential of VEO(TM) on diagnostic image quality and dose reduction in pediatric chest CT examinations. MATERIALS AND METHODS: Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDIvol 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. RESULTS: At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. CONCLUSIONS: At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The so-called < Sandwich Generation > (SG) is characterized by concurrent and competing professional, familial, and informal caregiving workloads. These stressors pose potential health risks. However, the current knowledge about SG characteristics and perceived state of health are insufficient to allow occupational health nurses to develop evidence-based interventions designed for health promotion. We aimed to describe this population and examine the relationships between these coexisting workloads and their perceived health. This study is based on a descriptive, correlational design. Employees of a Swiss public administration completed an electronic questionnaire. Of 844 respondents, 23 % are SG members. Ages of frailed parents or parents-in-law, co-residence with the latters, children still living at home predict that employees could be members of the SG. Perceived physical health status of SG members is rated better than mental health status. The heterogeneity of SG is reflected in three clusters. Finally, physical health score is the only that differs from the other health scores adjusting for clusters and sex. This study provides a foundation for developing preventive interventions targeting the SG.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We assessed the impact of a multicomponent worksite health promotion program for0 reducing cardiovascular risk factors (CVRF) with short intervention, adjusting for regression towards the mean (RTM) affecting such nonexperimental study without control group. METHODS: A cohort of 4,198 workers (aged 42 +/- 10 years, range 16-76 years, 27% women) were analyzed at 3.7-year interval and stratified by each CVRF risk category (low/medium/high blood pressure [BP], total cholesterol [TC], body mass index [BMI], and smoking) with RTM and secular trend adjustments. Intervention consisted of 15 min CVRF screening and individualized counseling by health professionals to medium- and high-risk individuals, with eventual physician referral. RESULTS: High-risk groups participants improved diastolic BP (-3.4 mm Hg [95%CI: -5.1, -1.7]) in 190 hypertensive patients, TC (-0.58 mmol/l [-0.71, -0.44]) in 693 hypercholesterolemic patients, and smoking (-3.1 cig/day [-3.9, -2.3]) in 808 smokers, while systolic BP changes reflected RTM. Low-risk individuals without counseling deteriorated TC and BMI. Body weight increased uniformly in all risk groups (+0.35 kg/year). CONCLUSIONS: In real-world conditions, short intervention program participants in high-risk groups for diastolic BP, TC, and smoking improved their CVRF, whereas low-risk TC and BMI groups deteriorated. Future programs may include specific advises to low-risk groups to maintain a favorable CVRF profile.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: We assessed expectations to improve cardiovascular disease risk factors (CVD-RF) in participants to a health promotion program. PARTICIPANTS AND METHODS: Blood pressure (BP), blood glucose (BG), blood total cholesterol (TC), body mass index (BMI), and self-reported smoking were assessed in 1,598 volunteers from the general public (men: 40%; mean age: 56.7 +/- 12.7 years) participating in a mobile health promotion program in the Vaud canton, Switzerland. Participants were asked about their expectation to have their CVD-RF improved at a next visit scheduled 2-3 years later. RESULTS: Expectation for improved control was found in 90% of participants with elevated BP, 91% with elevated BG, 45% with elevated TC, 44% who were overweight, and 35% who were smoking. Expectation for TC improvement was reported more often by men, persons with high level of TC, and persons who had consulted a doctor in the past 12 months. Expectations to lose weight and to quit smoking were found more often in younger persons than the older ones. CONCLUSION: Volunteers from the general population participating in a health promotion program expected improved control more often for hypertension and dysglycemia than for dyslipidemia, overweight and smoking.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Current 2D black blood coronary vessel wall imaging suffers from a relatively limited coverage of the coronary artery tree. Hence, a 3D approach facilitating more extensive coverage would be desirable. The straightforward combination of a 3D-acquisition technique together with a dual inversion prepulse can decrease the effectiveness of the black blood preparation. To minimize artifacts from insufficiently suppressed blood signal of the nearby blood pools, and to reduce residual respiratory motion artifacts from the chest wall, a novel local inversion technique was implemented. The combination of a nonselective inversion prepulse with a 2D selective local inversion prepulse allowed for suppression of unwanted signal outside a user-defined region of interest. Among 10 subjects evaluated using a 3D-spiral readout, the local inversion pulse effectively suppressed signal from ventricular blood, myocardium, and chest wall tissue in all cases. The coronary vessel wall could be visualized within the entire imaging volume.