178 resultados para Aortic aneurism


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new, investigational, parenteral form of sparfloxacin was compared with ceftriaxone in the treatment of experimental endocarditis caused by either of three penicillin-susceptible streptococci or one penicillin-resistant streptococcus. Both drugs have prolonged half-lives in serum, allowing single daily administration to humans. Sparfloxacin had relatively low MICs (0.25 to 0.5 mg/liter) for all four organisms and was also greater than or equal to eight times more effective than the other quinolones against 21 additional streptococcal isolates recovered from patients with bacteremia. Ceftriaxone MICs were 0.032 to 0.064 mg/liter for the penicillin-susceptible strains and 2 mg/liter for the resistant isolate. Both antibiotics resulted in moderate bacterial killing in vitro. Rats with catheter-induced aortic vegetations were inoculated with 10(7) CFU of the test organisms. Antibiotic treatment was started 48 h later and lasted either 3 or 5 days. The drugs were injected at doses which mimicked the kinetics in human serum produced by one intravenous injection of 400 mg of sparfloxacin (i.e., the daily dose expected to be given to human adults) and 2 g of ceftriaxone. Both antibiotics significantly decreased the bacterial densities in the vegetations. However, sparfloxacin was slower than ceftriaxone in its ability to eradicate valvular infection caused by penicillin-susceptible bacteria. While this difference was quite marked after 3 days of therapy, it tended to vanish when treatment was prolonged to 5 days. In contrast, sparfloxacin was very effective against the penicillin-resistant isolate, an organism against which ceftriaxone therapy failed in vivo. No sparfloxacin-resistant mutant was selected during therapy. Thus, in the present experimental setting, this new, investigational, parenteral form of sparfloxacin was effective against severe infections caused by both penicillin-susceptible and penicillin-resistant streptococci.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Acute treatment of ischemic stroke patients presenting more than eight-hours after symptom onset remains limited and largely unproven. Partial aortic occlusion using the NeuroFlo catheter can augment cerebral perfusion in animals. We investigated the safety and feasibility of employing this novel catheter to treat ischemic stroke patients eight-hours to 24 h following symptom onset. METHODS: A multicenter, single-arm trial enrolled ischemic stroke patients at nine international academic medical centers. Eligibility included age 18-85 years old, National Institutes of Health stroke scale (NIHSS) score between four and 20, within eight-hours to 24 h after symptom onset, and perfusion-diffusion mismatch confirmed by magnetic resonance imaging. The primary outcome was all adverse events occurring from baseline to 30 days posttreatment. Secondary outcomes included stroke severity on neurological indices through 90 days. This study is registered with ClinicalTrials.gov, number NCT00436592. RESULTS: A total of 26 patients were enrolled. Of these, 25 received treatment (one excluded due to aortic morphology); five (20%) died. Favorable neurological outcome at 90 days (modified Rankin score 0-2 vs. 3-6) was associated with lower baseline NIHSS (P < 0·001) and with longer duration from symptom discovery to treatment. There were no symptomatic intracranial hemorrhages or parenchymal hematomas. Asymptomatic intracranial hemorrhage was visible on computed tomography in 32% and only on microbleed in another 20%. CONCLUSIONS: Partial aortic occlusion using the NeuroFlo catheter, a novel collateral therapeutic strategy, appears safe and feasible in stroke patients eight-hours to 24 h after symptom onset.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The aim of this investigation was to improve the hemodynamics during venoarterial bypass by remote decompression of the left ventricle (LV). METHODS: Venoarterial bypass was established in 5 bovine experiments (69+/-10 kg) by the transjugular insertion of a self-expanding cannula (smartcanula) with return through a carotid artery. Cardiogenic shock was simulated with ventricular fibrillation induced by an external stimulator. Left ventricular decompression was achieved by switching to transfemoral drainage of the pulmonary artery (PA) with a long self-expanding cannula. RESULTS: Initial pump flow was 4.7+/-0.9 l/min and the aortic pressure accounted for 75+/-21 mmHg. After induction of ventricular fibrillation, the pump flow dropped after 11+/-8 min to 2.5+/-0.1 l/min. Transfemoral decompression increased the pump flow to 5.6+/-0.7 l/min, while the RV pressure decreased from 27+/-9 to 3+/-5 mmHg, the PA pressure decreased from 29+/-7 to 5+/-4 mmHg, the LV pressure decreased from 29+/-6 to 7+/-2 mmHg, and the aortic pressure increased from 31+/-3 to 47+/-11 mmHg. CONCLUSIONS: Remote drainage of the pulmonary artery during venoarterial bypass allows for effective decompression of the left ventricle and provides superior hemodynamics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conventional coronary magnetic resonance angiography (MRA) techniques display the coronary blood-pool along with the surrounding structures, including the myocardium, the ventricular and atrial blood-pool, and the great vessels. This representation of the coronary lumen is not directly analogous to the information provided by x-ray coronary angiography, in which the coronary lumen displayed by iodinated contrast agent is seen. Analogous "luminographic" data may be obtained using MR arterial spin tagging (projection coronary MRA) techniques. Such an approach was implemented using a 2D selective "pencil" excitation for aortic spin tagging in concert with a 3D interleaved segmented spiral imaging sequence with free-breathing, and real-time navigator technology. This technique allows for selective 3D visualization of the coronary lumen blood-pool, while signal from the surrounding structures is suppressed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rapport de synthèse : Mesures de l'aorte ascendante par scanner synchronisé au rythme cardiaque: une étude pilote pour établir des valeurs normatives dans le cadre des futures thérapies par transcathéter. Objectif : L'objectif de cette étude est d'établir les valeurs morphométriques normatives de l'aorte ascendante à l'aide de l'angiographie par scanner synchronisé au rythme cardiaque, afin d'aider au développement des futurs traitements par transcathéter. Matériels et méthodes : Chez soixante-dix-sept patients (âgé de 22 à 83 ans, âge moyen: 54,7 ans), une angiographie par scanner synchronisé au rythme cardiaque a été réalisée pour évaluation des vaisseaux coronaires. Les examens ont été revus afin d'étudier l'anatomie de la chambre de chasse du ventricule gauche jusqu'au tronc brachio-céphalique droit. A l'aide de programmes de reconstructions multiplanaires et de segmentation automatique, différents diamètres et longueurs considérés comme importants pour les futurs traitements par transcathéter ont été mesurés. Les valeurs sont exprimées en moyennes, médianes, maximums, minimums, écart-types et en coefficients de variation. Les variations de diamètre de l'aorte ascendante durant le cycle cardiaque ont été aussi considérées. Résultats : Le diamètre moyen de la chambre de chasse du ventricule gauche était de 20.3+/-3.4 mm. Au niveau du sinus coronaire de l'aorte, il était de 34.2+/-4.1 mm et au niveau de la jonction sinotubulaire il était de 29.7+/-3.4 mm. Le diamètre moyen de l'aorte ascendante était de 32.7+/-3.8 mm. Le coefficient de variation de ces mesures variait de 12 à 17%. La distance moyenne entre l'insertion proximale des valvules aortiques et le départ du tronc brachio-céphalique droit était de 92.6+/-11.8 mm. La distance moyenne entre l'insertion proximale des valvules aortiques et l'origine de l'artère coronaire proximale était de 12.1+/-3.7 mm avec un coefficient de variation de 31%. La distance moyenne entre les deux ostia coronaires était de 7.2+/-3.1 mm avec un coefficient de variation de 43%. La longueur moyenne du petit arc de l'aorte ascendante entre l'artère coronaire gauche et le tronc brachio-céphalique droit était de 52.9+/-9.5 mm. La longueur moyenne de la continuité fibreuse entre la valve aortique et la valvule mitrale antérieure était de 14.6+/-3.3 mm avec un coefficient de variation de 23%. L'aire moyenne de la valve aortique était de 582.0+/-131.9 mm2. La variation du diamètre antéro-postérieur et transverse de l'aorte ascendante était respectivement de 8.4% et de 7.3%. Conclusion Il existe d'importantes variations inter-individuelles dans les mesures de l'aorte ascendante avec cependant des variations intra-individuelles faibles durant le cycle cardiaque. De ce fait, une approche personnalisée pour chaque patient est recommandée dans la confection des futures endoprothèses de l'aorte ascendante. Le scanner synchronisé au rythme cardiaque jouera un rôle prépondérant dans le bilan préthérapeutique. Abstract : The aim of this study was to provide an insight into normative values of the ascending aorta in regards to novel endovascular procedures using ECG-gated multi-detector CT angiography. Seventy-seven adult patients without ascending aortic abnormalities were evaluated. Measurements at relevant levels of the aortic root and ascending aorta were obtained. Diameter variations of the ascending aorta during cardiac cycle were also considered. Mean diameters (mm) were as follows: LV outflow tract 20.3+/-3.4, coronary sinus 34.2+/-4.1, sinotubular junction 29.7+-3.4 and mid ascending aorta 32.7+/-3.8 with coefficients of variation (CV) ranging from 12 to 17%. Mean distances (mm) were: from the plane passing through the proximal insertions of the aortic valve cusps to the right brachio-cephalic artery (BCA) 92.6111.8, from the plane passing through the proximal insertions of the aortic valve cusps to the proximal coronary ostium 12.1+/-3.7, and between both coronary ostia 7.2+/-3.1, minimal arc of the ascending aorta from left coronary ostium to right BCA 52.9 X9.5, and the fibrous continuity between the aortic valve and the anterior leaflet of the mitral valve 14.óf3.3, CV 13-43%. Mean aortic valve area was 582+-131.9 mm2. The variations of the antero-posterior and transverse diameters of the ascending aorta during the cardiac cycle were 8.4% and 7.3%, respectively. Results showed large inter-individual variations in diameters and distances but with limited intra-individual variations during the cardiac cycle. A personalized approach for planning endovascular devices must be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

1. In some tissues, a decrease in the number of cell surface receptors and alterations of the receptor coupling have been proposed as possible mechanisms mediating the deleterious effects of bacterial endotoxin in septic shock. 2. The effects of bacterial lipopolysaccharide (Escherichia coli 0111-B4; LPS) on vascular angiotensin II and vasopressin receptors have been examined in cultured aortic smooth muscle cells (SMC) of the rat by use of radioligand binding techniques. 3. In vascular SMC exposed to 1 micrograms ml-1 endotoxin for 24 h, a significant increase in angiotensin II binding was found. The change in [125I]-angiotensin II binding corresponded to an increase in the number of receptors whereas the affinity of the receptors was not affected by LPS. In contrast, no change in [3H]-vasopressin binding was observed. 4. The pharmacological characterization of angiotensin II binding sites in control and LPS-exposed cells demonstrated that LPS induced an increase in the AT1 subtype of the angiotensin II receptors. Receptor coupling as evaluated by measuring total inositol phosphates was not impaired by LPS. 5. The effect of LPS on the angiotensin II receptor was dose-, time- and protein-synthesis dependent and was associated with an increased expression of the receptor gene. 6. The ability of LPS to increase angiotensin II binding in cultured vascular SMC was independent of the endotoxin induction of NO-synthase. 7. These results suggest that, besides inducing factors such as cytokines and NO-synthase, endotoxin may enhance the expression of cell surface receptors. The surprising increase in angiotensin II binding in LPS exposed VSM cells may represent an attempt by the cells to compensate for the decreased vascular responsiveness. It may also result from a non-specific LPS-related induction of genes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Decompensated heart failure, either acute (cardiogenic shock) or chronic (terminal heart failure) may become refractory to conventional therapy, then requiring mechanical assistance of the failing heart to improve hemodynamics. In the acute setting, aortic balloon counterpulsation is used as first line therapy. In case of failure, other techniques include the extracorporal membrane oxygenator or a percutaneous left ventricular assist device, such as the TandemHeart or the Impella. In chronic heart failure, long-term left ventricular assist devices can be surgically implanted. The continuous flow devices give here the best results. The aim of the present review article is to present with some details the various methods of mechanical left ventricle assistance to which the intensivist may be confronted in his daily practice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Immunoglobulin G4 (IgG4)-related fibroinflammatory systemic disease accounts for 7% of all noninfectious aneurysms of the thoracic aorta. A patient was admitted with a symptomatic ascending aortic aneurysm and thickened aortic wall (outer/inner diameter 55/45 mm), which was replaced. Probes revealed IgG4-related aortitis associated with a primary tuberculosis infection. Corticosteroid and antituberculosis therapies were used, and the patient's clinical evolution was favorable. The optimal treatment strategy of IgG4-related aortitis, a new entity, remains vague. Inner aortic diameter alone does not justify aortic replacement, but wall thickening may mimic intramural hematoma. In this particular case of IgG4-related aortitis, immunosuppressive treatment alone, as an alternative to a surgical procedure, may be debatable.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The development of new medical devices, such as aortic valves, requires numerous preliminary studies on animals and training of personnel on cadavers before the devices can be used in patients. Postmortem circulation, a technique used for postmortem angiography, allows the vascular system to be reperfused in a way similar to that in living persons. This technique is used for postmortem investigations to visualize the human vascular system and to make vascular diagnoses. Specific material for reperfusing a human body was developed recently. Our aim was to investigate whether postmortem circulation that imitates in vivo conditions allows for the testing of medical materials on cadavers. We did this by delivering an aortic valve using minimally invasive methods. Postmortem circulation was established in eight corpses to recreate an environment as close as possible to in vivo conditions. Mobile fluoroscopy and a percutaneous catheterization technique were used to deliver the material to the correct place. Once the valve was implanted, the heart and primary vessels were extracted to confirm its position. Postmortem circulation proved to be essential in several of the cadavers because it helped the clinicians to deliver the material and improve their implantation techniques. Due to the intravascular circulation, sites with substantial arteriosclerotic stenosis could be bypassed, which would have been impossible without perfusion. Although originally developed for postmortem investigations, this reperfusion technique could be useful for testing new medical devices intended for living patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Infected lateral cervical cysts in newborn are rare. We present the case of a baby born at 41 weeks of gestation. At day 3, persistent cyanosis was noted, and a mass appeared in the left cervical region next to the sternocleidomastoid muscle. No cutaneous sinus was visible. Ultrasound imaging showed no sign of blood flow within the mass and no septae. The mass extended down to the aortic arch and pushed the trachea to the right. A cervical lymphangioma was first suspected. Puncture of the mass evacuated 80 mL of pus, and a drain was put in place. Opacification through the drain showed a tract originating from the left pyriform fossa. Preoperative laryngoscopy and catheterization of the fistula tract confirmed the diagnosis. The cyst was totally excised up to the sinus with the assistance of a guidewire inserted orally through a rigid laryngoscope. This is a rare case of an infected pyriform sinus cyst in the neonatal period.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Current applications of cardiac magnetic resonance (CMR) imaging offer a wide spectrum of indications in the setting of acute cardiac care. In particular, CMR is helpful for the differential diagnosis of chest pain by detection of myocarditis and pericarditis. Also, takotsubo cardiomyopathy and acute aortic diseases can be evaluated by CMR and are important differential diagnoses in patients with acute chest pain. In patients with restricted windows for echocardiography, CMR is the method of choice to evaluate complications of acute myocardial infarction (AMI). In AMI, CMR allows for a unique characterization of myocardial damage by quantifying necrosis, microvascular obstruction, oedema (=area at risk), and haemorrhage. These capabilities will help us to understand better the pathophysiological events during infarction and will also allow to assess new treatment strategies in AMI. To what extent the information on tissue damage will guide patient management is not yet clear and further research in this field is warranted. In the near future, CMR will certainly become more routine in acute cardiac care units, as manufacturers are now focusing strongly on this aspect of user-friendliness. Finally, in the next decade or so, MRI of other nuclei such as fluorine and carbon might become a clinical reality, which would allow for metabolic and targeted molecular imaging with excellent sensitivity and specificity

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The observation concerns a patient who was professionally exposed to silica dust. Radiologically he presented a diffuse interstitial infiltrate and clinically an obstructive syndrome with emphysem. The diagnosis of silicosis was made. The development was followed during 12 years without important modification of the X-ray or the respiratory functions. The patient died of a ruptured aortic aneurysm. At the autopsy the examination of the lungs permitted to exclude the initial diagnosis of silicosis and to conclude to an histiocytosis X. This diagnostic mistake allows to get on some radiological, clinical and epidemiological aspects, characteristic or these both pathologies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Several markers of atherosclerosis and of inflammation have been shown to predict coronary heart disease (CHD) individually. However, the utility of markers of atherosclerosis and of inflammation on prediction of CHD over traditional risk factors has not been well established, especially in the elderly. Methods: We studied 2202 men and women, aged 70-79, without baseline cardiovascular disease over 6-year follow-up to assess the risk of incident CHD associated with baseline noninvasive measures of atherosclerosis (ankle-arm index [AAI], aortic pulse wave velocity [aPWV]) and inflammatory markers (interleukin-6 [IL-6], C-reactive protein [CRP], tumor necrosis factor-a [TNF-a]). CHD events were studied as either nonfatal myocardial infarction or coronary death ("hard" events), and "hard" events plus hospitalization for angina, or the need for coronary-revascularization procedures (total CHD events). Results: During the 6-year follow-up, 283 participants had CHD events (including 136 "hard" events). IL-6, TNF-a and AAI independently predicted CHD events above Framingham Risk Score (FRS) with hazard ratios [HR] for the highest as compared with the lowest quartile for IL-6 of 1.95 (95%CI: 1.38-2.75, p for trend <0.001), TNF-a of 1.45 (95%CI: 1.04-2.02, p for trend 0.03), of 1.66 (95%CI: 1.19-2.31) for AAI 0.9, as compared to AAI 1.01-1.30. CRP and aPWV were not independently associated with CHD events. Results were similar for "hard" CHD events. Addition of IL-6 and AAI to traditional cardiovascular risk factors yielded the greatest improvement in the prediction of CHD; C-index for "hard"/total CHD events increased from 0.62/0.62 for traditional risk factors to 0.64/0.64 for IL-6 addition, 0.65/0.63 for AAI, and 0.66/0.64 for IL-6 combined with AAI. Being in the highest quartile of IL-6 combined with an AAI 0.90 or >1.40 yielded an HR of 2.51 (1.50-4.19) and 4.55 (1.65-12.50) above FRS, respectively. With use of CHD risk categories, risk prediction at 5 years was more accurate in models that included IL-6, AAI or both, with 8.0, 8.3 and 12.1% correctly reclassified, respectively. Conclusions: Among older adults, markers of atherosclerosis and of inflammation, particularly IL-6 and AAI, are independently associated with CHD. However, these markers only modestly improve cardiovascular risk prediction beyond traditional risk factors.