311 resultados para mapping technique
Resumo:
PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.
Resumo:
The corpus callosum (CC) plays a crucial role in interhemispheric communication. It has been shown that CC formation relies on the guidepost cells located in the midline region that include glutamatergic and GABAergic neurons as well as glial cells. However, the origin of these guidepost GABAergic neurons and their precise function in callosal axon pathfinding remain to be investigated. Here, we show that two distinct GABAergic neuronal subpopulations converge toward the midline prior to the arrival of callosal axons. Using in vivo and ex vivo fate mapping we show that CC GABAergic neurons originate in the caudal and medial ganglionic eminences (CGE and MGE) but not in the lateral ganglionic eminence (LGE). Time lapse imaging on organotypic slices and in vivo analyses further revealed that CC GABAergic neurons contribute to the normal navigation of callosal axons. The use of Nkx2.1 knockout (KO) mice confirmed a role of these neurons in the maintenance of proper behavior of callosal axons while growing through the CC. Indeed, using in vitro transplantation assays, we demonstrated that both MGE- and CGE-derived GABAergic neurons exert an attractive activity on callosal axons. Furthermore, by combining a sensitive RT-PCR technique with in situ hybridization, we demonstrate that CC neurons express multiple short and long range guidance cues. This study strongly suggests that MGE- and CGE-derived interneurons may guide CC axons by multiple guidance mechanisms and signaling pathways. © 2013 Wiley Periodicals, Inc. Develop Neurobiol 73: 647-672, 2013.
Resumo:
L' évaluation quantitative des dangers et des expositions aux nanomatériaux se heurte à de nombreuses incertitudes qui ne seront levées qu'à mesure de la progression des connaissances scientifiques de leurs propriétés. L' une des conséquences de ces incertitudes est que les valeurs limites d'exposition professionnelle définies actuellement pour les poussières ne sont pas nécessairement pertinentes aux nanomatériaux. En l'absence de référentiel quantitatif et, à la demande de la DGS pour éclairer les réflexions de l' AFNOR et de l'ISO sur le sujet, une démarche de gestion graduée des risques (control banding) a été élaborée au sein de l' Anses. Ce développement a été réalisé à l'aide d'un groupe d'experts rapporteurs rattaché au Comité d'experts spécialisés évaluation des risques liés aux agents physiques, aux nouvelles technologies et aux grands aménagements. La mise en oeuvre de la démarche de gestion graduée des risques proposée repose sur quatre grandes étapes: 1. Le recueil des informations. Cette étape consiste à réunir les informations disponibles sur les dangers du nanomatériau manufacturé considéré ; ainsi que sur l'exposition potentielle des personnes aux postes de travail (observation sur le terrain, mesures, etc.). 2. L'attribution d'une bande de danger. Le danger potentiel du nanomatériau manufacturé présent, qu'il soit brut où incorporé dans une matrice (liquide ou solide) est évalué dans cette étape. La bande danger attribuée tient compte de la dangerosité du produit bulk ou de sa substance analogue à l'échelle non-nanométrique, de la bio-persistance du matériau (pour les matériaux fibreux), de sa solubilité et de son éventuelle réactivité. 3. Attribution d'une bande d'exposition. La bande d'exposition du nanomatériau manufacturé considéré ou du produit en contenant est définie par le niveau de potentiel d'émission du produit. Elle tient compte de sa forme physique (solide, liquide, poudre aérosol), de sa pulvérulence et de sa volatilité. Le nombre de travailleurs, la fréquence, la durée d'exposition ainsi que la quantité mise en oeuvre ne sont pas pris en compte, contrairement à une évaluation classique des risques chimiques. 4. Obtention d'une bande de maîtrise des risques. Le croisement des bandes de dangers et d'exposition préalablement attribuées permet de défi nir le niveau de maîtrise du risque. Il fait correspondre les moyens techniques et organisationnels à mettre en oeuvre pour maintenir le risque au niveau le plus faible possible. Un plan d'action est ensuite défi ni pour garantir l'effi cacité de la prévention recommandée par le niveau de maîtrise déterminé. Il tient compte des mesures de prévention déjà existantes et les renforce si nécessaire. Si les mesures indiquées par le niveau de maîtrise de risque ne sont pas réalisables, par exemple, pour des raisons techniques ou budgétaires, une évaluation de risque approfondie devra être réalisée par un expert. La gestion graduée des risques est une méthode alternative pour réaliser une évaluation qualitative de risques et mettre en place des moyens de prévention sans recourir à une évaluation quantitative des risques. Son utilisation semble particulièrement adaptée au contexte des nanomatériaux manufacturés, pour lequel les choix de valeurs de référence (Valeurs limites d'exposition en milieu professionnel) et des techniques de mesurage appropriées souffrent d'une grande incertitude. La démarche proposée repose sur des critères simples, accessibles dans la littérature scientifi que ou via les données techniques relatives aux produits utilisés. Pour autant, sa mise en oeuvre requiert des compétences minimales dans les domaines de la prévention des risques chimiques (chimie, toxicologie, etc.), des nanosciences et des nanotechnologies.
Resumo:
The phosphatidylinositol 3-kinase-mammalian target of rapamycin (PI3K-mTOR) pathway plays pivotal roles in cell survival, growth, and proliferation downstream of growth factors. Its perturbations are associated with cancer progression, type 2 diabetes, and neurological disorders. To better understand the mechanisms of action and regulation of this pathway, we initiated a large scale yeast two-hybrid screen for 33 components of the PI3K-mTOR pathway. Identification of 67 new interactions was followed by validation by co-affinity purification and exhaustive literature curation of existing information. We provide a nearly complete, functionally annotated interactome of 802 interactions for the PI3K-mTOR pathway. Our screen revealed a predominant place for glycogen synthase kinase-3 (GSK3) A and B and the AMP-activated protein kinase. In particular, we identified the deformed epidermal autoregulatory factor-1 (DEAF1) transcription factor as an interactor and in vitro substrate of GSK3A and GSK3B. Moreover, GSK3 inhibitors increased DEAF1 transcriptional activity on the 5-HT1A serotonin receptor promoter. We propose that DEAF1 may represent a therapeutic target of lithium and other GSK3 inhibitors used in bipolar disease and depression.
Resumo:
INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.
Hazard mapping for the eastern face of Turtle Mountain, adjacent to the Frank Slide, Alberta, Canada
Resumo:
OBJECTIVES: Lesion detection and characterization in multiple sclerosis (MS) are an essential part of its clinical diagnosis and an important research field. In this pilot study, we applied the recently introduced two inversion-contrast magnetization-prepared rapid gradient echo sequence (MP2RAGE) to patients with early-stage MS.¦MATERIALS AND METHODS: The MP2RAGE is a 3-dimensional (3D) magnetization-prepared rapid gradient echo derivative providing homogeneous T1 weighting and simultaneous T1 mapping. The MP2RAGE performance was compared with that of 2 clinical routine sequences (2D fluid-attenuated inversion recovery [FLAIR] and 3D magnetization-prepared rapid gradient echo [MP-RAGE]) and 2 state-of-the art clinical research sequences (the 3D FLAIR-SPACE [sampling perfection with application-optimized contrasts by using different flip-angle evolutions], a fluid-attenuated variable flip-angle fast spin echo technique, and the 3D double-inversion recovery SPACE). A cohort of 10 early-stage female MS patients (age, 31.6 ± 4.7 years; disease duration, 3.8 ± 1.9 years; median expanded disability status scale score, 1.75) and 10 age- and gender-matched controls were enrolled after approval of the local institutional review board was obtained. Multiple sclerosis lesions were identified and assigned to brain locations and tissue types by two experienced physicians in all 5 contrasts. Subsequently, lesions were manually delineated for comparison and statistical analysis of lesion count, volume and quantitative measures.¦RESULTS AND CONCLUSIONS: The results show that the 3D T1-weighted high-resolution MP2RAGE contrast provides a sensitive means for MS lesion assessment. The additional quantitative T1 relaxation time maps obtained with the MP2RAGE provide further potential diagnostic and prognostic information that could help (a) to better discriminate lesion subtypes and (b) to stage and predict the activity and the evolution of MS. Results also indicate that the T2-weighted double-inversion recovery and FLAIR-SPACE contrasts are attractive complements to the MP2RAGE for lesion detection.
Resumo:
The paper deals with the development and application of the generic methodology for automatic processing (mapping and classification) of environmental data. General Regression Neural Network (GRNN) is considered in detail and is proposed as an efficient tool to solve the problem of spatial data mapping (regression). The Probabilistic Neural Network (PNN) is considered as an automatic tool for spatial classifications. The automatic tuning of isotropic and anisotropic GRNN/PNN models using cross-validation procedure is presented. Results are compared with the k-Nearest-Neighbours (k-NN) interpolation algorithm using independent validation data set. Real case studies are based on decision-oriented mapping and classification of radioactively contaminated territories.
Resumo:
Objective: Sentinel lymph node biopsy (SLNB) is a validated staging technique for breast carcinoma. Some women are exposed to have a second SLNB due to breast cancer recurrence or a second neoplasia (breast or other). Due to modi- fied anatomy, it has been claimed that previous axillary surgery represents a contra-indication to SLNB. Our objective was to analyse the literature to assess if a second SLNB is to be recommended or not. Methods: For the present study, we performed a review of all published data during the last 10 years on patients with previous axilla surgery and second SLNB. Results: Our analysis shows that second SLNB is feasible in 70%. Extra-axillary SNs rate (31%) was higher after radical lymph node dissection (ALND) (60% - 84%) than after SLNB alone (14% - 65%). Follow-up and com- plementary ALND following negative and positive second SLNB shows that it is a reliable procedure. Conclusion: The review of literature confirms that SLNB is feasible after previous axillary dissection. Triple technique for SN mapping is the best examination to highlight modified lymphatic anatomy and shows definitively where SLNB must be per- formed. Surgery may be more demanding as patients may have more frequently extra-axillary SN only, like internal mammary nodes. ALND can be avoided when second SLNB harvests negative SNs. These conclusions should however be taken with caution because of the heterogeneity of publications regarding SLNB and surgical technique.
Resumo:
From birth to early adulthood the brain undergoes dramatic modifications resulting in network development and optimization. In the present study we investigate the development of the human connectome but measuring myelination trajectories of individual connections over the entire brain structural network using high b-value diffusion imaging and tractography. We found significant changes in several network measures that support increased integration and efficiency. We also observe that the network doesn't myelinate at a uniform rate but with different myelination speeds dependant on the type of cortex.