271 resultados para isotope technique
Resumo:
INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.
Resumo:
Identification and relative quantification of hundreds to thousands of proteins within complex biological samples have become realistic with the emergence of stable isotope labeling in combination with high throughput mass spectrometry. However, all current chemical approaches target a single amino acid functionality (most often lysine or cysteine) despite the fact that addressing two or more amino acid side chains would drastically increase quantifiable information as shown by in silico analysis in this study. Although the combination of existing approaches, e.g. ICAT with isotope-coded protein labeling, is analytically feasible, it implies high costs, and the combined application of two different chemistries (kits) may not be straightforward. Therefore, we describe here the development and validation of a new stable isotope-based quantitative proteomics approach, termed aniline benzoic acid labeling (ANIBAL), using a twin chemistry approach targeting two frequent amino acid functionalities, the carboxylic and amino groups. Two simple and inexpensive reagents, aniline and benzoic acid, in their (12)C and (13)C form with convenient mass peak spacing (6 Da) and without chromatographic discrimination or modification in fragmentation behavior, are used to modify carboxylic and amino groups at the protein level, resulting in an identical peptide bond-linked benzoyl modification for both reactions. The ANIBAL chemistry is simple and straightforward and is the first method that uses a (13)C-reagent for a general stable isotope labeling approach of carboxylic groups. In silico as well as in vitro analyses clearly revealed the increase in available quantifiable information using such a twin approach. ANIBAL was validated by means of model peptides and proteins with regard to the quality of the chemistry as well as the ionization behavior of the derivatized peptides. A milk fraction was used for dynamic range assessment of protein quantification, and a bacterial lysate was used for the evaluation of relative protein quantification in a complex sample in two different biological states
Resumo:
Objectifs: Evaluer la faisabilité, les résultats préliminaires à court et long terme du vissage percutané de vissage trans -isthmique sous anesthésie locale et contrôle scannerdes lyses isthmiques de bas grades.Matériels et méthodes: Etude prospective monocentrique réalisée sur 10 patients ayant une lyse isthmique grade 1 et 2 résistant au traitement médical conventionnel. Une évaluationclinique était réalisée à un mois, 3 mois, 6 mois et un an post-opératoire par un évaluateur indépendant. L'indication est posée en concertation avec le service dechirurgie orthopédique.Résultats: Les lyses isthmiques étaient situées en L5-S1 avec 6 grades 1 et 4 grades 2. L'échelle analogique de la douleur (VAS) variait de 6 a 9 avec une moyenne de 7,8.L'indication opératoire chirurgicale était posée pour tous les patients par arthrodèse postérieure lombo -sacree. Pour chaque patient 2 vis étaient positionnées soitun total de 20 vis. Un suivi clinique était réalisé de 28 a 36 mois. L'EVA et ODI diminuaient de 7,8 +/- 1,7 à 1,9 +/- 1,2 et de 62,3 +/- 17,2 à 15,1 +/- 6,0respectivement. L'ensemble des résultats était stable dans le temps en particulier à long terme.Conclusion: La fixation précise de la lyse isthmique améliore la symptomatologie et probablement évite un glissement vertébral plus important , un suivi à plus long terme surune serie de patients plus importante devrait confirmer cette hypothèse.
Resumo:
INTRODUCTION: The arteries of bifurcation aneurysms are sometimes so angulated or tortuous that an exchange maneuver is necessary to catheterize them with a balloon or stent delivery catheter. Because of the risk of distal wire perforation associated with exchange maneuvers, we sought to find an alternative technique. METHODS: Our experience shows that a microcatheter tends to preferentially follow a previously placed microcatheter, even if the initial catheterization might be challenging. Accessing an artery with two microcatheters simultaneously may thus be an alternative to an exchange maneuver. Because of this tendency for catheters to behave like sheep following one another, we named this method the sheeping technique (ST). The ST consists of (a) first placing a 1.7 French microcatheter into the division branch requiring balloon or stent protection to straighten the course of the arteries in order to facilitate and (b) positioning in the same artery of a larger and stiffer balloon or stent microcatheter. Once the second balloon or stent microcatheter is in place, the first microcatheter can be pulled back and used to coil the aneurysm. RESULTS: Between January 2009 and December 2012, The ST was successfully used in 208/246 procedures (85 %). Conversion to an exchange maneuver was necessary in 38/246 (15 %). There were no arterial perforations or ischemic events related to the handling of both microcatheters. CONCLUSION: The sheeping technique may improve safety by replacing the need for an exchange maneuver during difficult balloon- or stent-assisted coiling.
Resumo:
PURPOSE: To objectively characterize different heart tissues from functional and viability images provided by composite-strain-encoding (C-SENC) MRI. MATERIALS AND METHODS: C-SENC is a new MRI technique for simultaneously acquiring cardiac functional and viability images. In this work, an unsupervised multi-stage fuzzy clustering method is proposed to identify different heart tissues in the C-SENC images. The method is based on sequential application of the fuzzy c-means (FCM) and iterative self-organizing data (ISODATA) clustering algorithms. The proposed method is tested on simulated heart images and on images from nine patients with and without myocardial infarction (MI). The resulting clustered images are compared with MRI delayed-enhancement (DE) viability images for determining MI. Also, Bland-Altman analysis is conducted between the two methods. RESULTS: Normal myocardium, infarcted myocardium, and blood are correctly identified using the proposed method. The clustered images correctly identified 90 +/- 4% of the pixels defined as infarct in the DE images. In addition, 89 +/- 5% of the pixels defined as infarct in the clustered images were also defined as infarct in DE images. The Bland-Altman results show no bias between the two methods in identifying MI. CONCLUSION: The proposed technique allows for objectively identifying divergent heart tissues, which would be potentially important for clinical decision-making in patients with MI.
Hydrogen isotope fractionations between amphiboles, micas, and fluids in alkaline igneous intrusions
Resumo:
RÉSUMÉ DE LA THÈSE Les teneurs des amphiboles en éléments majeurs et en isotopes stables ont été analysées dans plusieurs complexes ignés alcalins et hyperalcalins, dans le but de déterminer l'importance des variations de composition des minéraux pour le fractionnement isotopique de l'hydrogène dans un système naturel minéral-magma-fluide. Cette étude se concentre principalement sur les syénites néphéliniques de complexes intrusifs alcalins bien connus mais à chimie variable, dont les amphiboles, ainsi que d'autres silicates hydratés tels que micas et eudialytes, lorsque cela était possible, ont été séparés. L'intérêt principal s'est porté sur le complexe alcalin d'Ilímaussaq de la Province du Gardar, au Sud du Groenland. Dans une optique de comparaison, nous avons collecté et analysé d'autres échantillons provenant du complexe de Tugtutôq (Sud Groenland), des complexes de Khibina et Lovozero (Péninsule de Kola, Russie), du Mont St-Hilaire et du Mont Royal (Canada) et de 6 autres du nord-ouest de la Namibie (Cape Cross, Okenyenya, Messum, Etaneno, Kalkfeld,et Okorusu). Les compositions isotopiques de l'hydrogène des amphiboles des ces différentes zones présentent de grandes variations (-227 à -700/00), ce qui est atypique pour des magmas d'origine mantellique. Les valeurs comprises entre -80 et -400/00 indiquent une provenance du manteau. Ces larges variations de compositions ainsi que l'extrême appauvrissement en isotope lourd de l'hydrogène (D), en comparaison avec d'autres roches ignées, semblent être propres.aux roches alcalines et hyperalcalines de ce type, ce qui indiquerait un processus commun. Les différents complexes alcalins choisis présentent un large intervalle de composition chimique des amphiboles. La caractérisation des amphiboles par microscopie électronique et par spectroscopie Mössbauer contribuent à observer le contrôle du Fe sur le fractionnement des isotopes de l'hydrogène. En effet, cela a mis en évidence un contrôle du Fe sur le fractionnement et même, dans le cas du complexe hyperalcalin d'Ilímaussaq, une relation entre le rapport Fei3+/FeT et les variations du rapport D/H. Les complexes étudiés diffèrent de par leur index agpaïtique (Na+K/Al) et également de par leur contenu en fer. Les plus hautes valeurs en Fe (27-35 wt%) et en éléments alcalins dans les amphiboles, ainsi que les teneurs de D/H les plus basses et leur grande variation, sont celles du complexe d'Ilímaussaq. Les amphiboles de la Péninsule de Kola et du Canada sont similaires, mais toutefois moins appauvries en D. En ce qui concerne les amphiboles des complexes du NO de la Namibie, elles présentent des compositions isotopiques de l'hydrogène magmatiques normales (-73 à -100 0/00), contiennent moins de Fe (15-17 wt%) et sont fortement enrichies en Ca et moins en Na. Dans ce cas, l'alcalinité est moins importante en comparaison des autres complexes étudiés. En dehors des teneurs en éléments alcalins des amphiboles, l'alcalinité des fluides s'avère également un facteur important, ce qui est cohérent avec certaines suggestions à partir de systèmes expérimentaux. Afin de mieux contraindre ce facteur, des expériences d'échanges hydrothermaux entre les amphiboles et les fluides de salinité différente ont été effectuées en simulant des conditions naturelles. L'approximation d'amphiboles naturelles de complexes ignés alcalins, couplée aux expériences d'échange, aide à préciser les facteurs contrôlant le fractionnement des isotopes de l'hydrogène dans les roches alcalines. Les valeurs extrêmement basses de 3D des amphiboles de ces complexes alcalins peuvent être dues à une combinaison de différents facteurs, telles qu'une haute alcalinité, une haute teneur en Fe et une faible profondeur d'intrusion. Les grandes variations ainsi que les faibles valeurs de SD des amphiboles étudiées peuvent résulter d'un processus magmatique interne et il est peu probable que de l'eau météorique soit impliquée et/ou que le dégazage magmatique ait joué un rôle. THESIS ABSTRACT Major element and stable isotope compositions of amphiboles were analyzed from a number of alkaline and peralkaline igneous complexes in order to determine the importance of compositional variations in minerals to hydrogen isotope fractionations in natural mineral-melt-fluid systems. The thesis mainly focuses on nepheline syenites of well-studied, but chemically variable alkaline intrusive rocks, from which amphiboles and, if possible, other hydrous silicates such as micas and eudialytes were separated. The system of primary interest was the alkaline Ilímaussaq Complex of the Gardar Province of South Greenland. For the purpose of comparison additional samples were collected and examined from the Tugtutôq Complex (South Greenland), the Khibina and Lovozero Complexes (Kola Peninsular, Russia), Mount St-Hilaire and Mount Royal (Canada) and six further complexes from NW Namibia (Cape Cross, Okenyenya, Messum, Etaneno, Kalkfeld, and Okorusu). The hydrogen isotope compositions of amphiboles from the localities studied differ greatly, which is atypical for amphiboles from mantle, range between - 227 and - 700/00 (latter compatible with a simple mantle origin). As this wide range in compositions and the extreme depletion in the heavy hydrogen isotope (D) content relative to other igneous rocks appear to be unique to alkaline to peralkaline rocks of this type, a common process is indicated. The different alkaline complexes chosen cover a wide range of amphibole chemical compositions. Detailed chemical characterization of amphiboles by electron microprobe and Mössbauer spectroscopy analyses helped to constrain the control of Fe on the H-isotope fractionations. Complete characterization of the chemical compositions of the amphiboles support Fe-control on fractionations and at least for the peralkaline Ilímaussaq complex a relationship between Fe3+/FeT ratios and variations in D/H. The studied complexes differ in their agpaitic index (Na+K/Al) and also in their Fe-content. The most iron (27-35 wt. %) and alkaline element rich amphiboles, with the lowermost D/H ratio, as well with very wide range, are the ones from Ilímaussaq complex. Similar, but less D depleted amphiboles are from the Kola Peninsula and the Canadian localities. The complexes described from NW Namibia have amphiboles with normal magmatic hydrogen isotope composition (-730/00 to -1000/00), and have less Fe-content (15-17 wt. %), and are more Ca-and less Na-rich. In this case alkalinity is not that important in comparison to the other studied complexes. Beside the alkaline element contents in the amphiboles, the alkalinity of the fluids has been found to be an important factor, in conjunction with earlier suggestions from experimental systems. To further constrain this factor, hydrothermal exchange experiments between amphiboles and fluids of different salinity simulating natural conditions were performed. The approach of examining natural amphiboles from alkaline igneous complexes in parallel to performing exchange experiments - helped to further constrain the factors controlling the H-isotope fractionations in alkaline rocks. The observed changes between the hydrogen and oxygen isotope compositions of amphiboles and fluids before and after the experiments suggest that another phase was produced during the experiments, which influenced the final hydrogen isotope composition of the system. This presumably hydrous phase has also influenced the Fe3 +/Fe2+ ratio of the amphiboles, which became more oxidized. The extremely low SD values of amphiboles in these alkaline complexes may be due to a combination of different factors such as high alkalinity, high Fe-content, and shallow intrusion depths. This wide range and the low SD values of the amphiboles studied might be a result of internal, magmatic processes and it is unlikely that meteoric water was involved and/or magmatic degassing played an important role. RÉSUMÉ DE LA THÈSE (pour le grand public) Fractionnement isotopique de l'hydrogène entre amphiboles, micas et fluides dans des intrusions alcalines Zsófia Wáczek Directeur de thèse, Prof. Torsten W. Vennemann Institut de Minéralogie et Géochimie, Université de Lausanne Les roches alcalines et celles qui leurs sont associées sont des sources importantes de nombreux minéraux et minerais, tels l'apatite, le niobium, le diamant et autres pierres précieuses. Cette étude se concentre sur des complexes alcalins localisés dans le sud du Groenland, au Canada, dans la péninsule de Kola en Russie et au nord-ouest de la Namibie. Ces complexes sont composés de roches ayant cristallisé à partir de magmas et de fluides très enrichis en alcalins. Cet enrichissement permet la précipitation de minéraux inhabituels riches en potassium et/ou sodium, telles les amphiboles sodiques, également enrichies en fer. Les amphiboles étudiées ont des compositions calciques, sodi-calciques et sodiques, qui reflètent leurs différents environnements de formation. Des études précédentes ont révélé une large gamme de rapports isotopiques de l'hydrogène dans les amphiboles de roches hyperalcalines, dont certains extrêmement bas. Cette variation importante est très intrigante, sachant que des valeurs entre -40 et -800/00 correspondent à des silicates ignés hydratés et non altérés, alors que des valeurs descendant jusqu'a -1500/00 nécessiteraient une altération par de l'eau météorique et/ou une contamination par les roches environnantes ou des sédiments riches en matière organique. Dans lé cas précis du complexe d'Ilímaussaq (sud du Groenland), aucune de ces explications n'a pu être démontrée et des valeurs encore plus faibles ont été trouvées. Le complexe d'Ilímaussaq présente des valeurs de rapport isotopique de l'hydrogène entre -227 et -500/00 dans les amphiboles. Une origine mantellique permet d'expliquer les valeurs élevées, mais d'autres processus doivent entrer en jeu pour engendrer les valeurs les plus négatives. C'est à l'identification de ces processus que nous nous sommes attachés dans ce travail. Les grandes variations observées dans les teneurs en fer et dans le rapport Fe3+/FeT des roches et des minéraux de ces complexes sont corrélées avec d'autres paramètres chimiques, tels que la composition isotopique de l'hydrogène dans les amphiboles. Nous avons dès lors abordé les questions suivantes: quelle est la relation entre la teneur en fer des amphiboles et leur composition isotopique? Que nous apprennent les changements de la teneur en fer et les changements dans le rapport Fe3+/FeT sur les processus pétrologiques dans ces roches? Pour répondre à ces questions, nous avons analysé les compositions isotopiques de l'oxygène et de l'hydrogène dans les amphiboles et d'autres silicates hydratés. La composition chimique et le rapport Fe3+/FeT des amphiboles ont également été déterminés. Des expériences hydrothermales simulant des conditions naturelles ont été entreprises afin de mieux comprendre les processus de fractionnement isotopiques dans ces systèmes très alcalins. Nos conclusions sont les suivantes: (1) Les valeurs extrêmement faibles ainsi que les larges variations des rapports isotopiques de l'hydrogène des amphiboles de ces complexes alcalins sont dues à une combinaison de facteurs tels que la forte alcalinité, la haute teneur en fer et la profondeur très faible de l'intrusion. (2) Ces valeurs sont probablement le résultat de processus magmatiques internes. (3) Il est peu probable que les eaux météoriques et/ou le dégazage magmatique aient joué un rôle lors de la formation de ces amphiboles. (4) Certaines corrélations, en accord avec les études précédentes, ont pu être trouvées au niveau des concentrations en fer. (5) Dans le cas du complexe d'Ilímaussaq exclusivement, une relation a été trouvée entre le rapport Fe3+/FeT et la composition isotopique de l'hydrogène des amphiboles.
Resumo:
Two methods of differential isotopic coding of carboxylic groups have been developed to date. The first approach uses d0- or d3-methanol to convert carboxyl groups into the corresponding methyl esters. The second relies on the incorporation of two 18O atoms into the C-terminal carboxylic group during tryptic digestion of proteins in H(2)18O. However, both methods have limitations such as chromatographic separation of 1H and 2H derivatives or overlap of isotopic distributions of light and heavy forms due to small mass shifts. Here we present a new tagging approach based on the specific incorporation of sulfanilic acid into carboxylic groups. The reagent was synthesized in a heavy form (13C phenyl ring), showing no chromatographic shift and an optimal isotopic separation with a 6 Da mass shift. Moreover, sulfanilic acid allows for simplified fragmentation in matrix-assisted laser desorption/ionization (MALDI) due the charge fixation of the sulfonate group at the C-terminus of the peptide. The derivatization is simple, specific and minimizes the number of sample treatment steps that can strongly alter the sample composition. The quantification is reproducible within an order of magnitude and can be analyzed either by electrospray ionization (ESI) or MALDI. Finally, the method is able to specifically identify the C-terminal peptide of a protein by using GluC as the proteolytic enzyme.
Resumo:
Many studies in continental areas have successfully used the oxygen isotope composition of fossil ostracod valves to reconstruct past hydrological conditions associated with large changes in climate. Yet, ostracods are known to crystallise their valves out of isotopic equilibrium for oxygen and they generally have higher 18O contents compared to inorganic calcite grown at equilibrium under the same condi- tions. A review of vital offsets determined for continental ostracods indicates that vital offsets might change from site to site, questioning a potential influence of environmental conditions on oxygen isotope fractionation in ostracods. Results from the literature suggest that pH has no influence on ostracod vital offset. A re-evaluation of results from Li and Liu (J Paleolimnol 43:111-120, 2010) suggests that salin- ity may influence oxygen isotope fractionation in ostracods, with lower vital offsets for higher salinities. Such a relationship was also observed for the vital offsets determined by Chivas et al. (The ostracoda- applications in quaternary research. American Geo- physical Union, Washington, DC, 2002). Yet, when results of all studies are compiled, the correlation between vital offsets and salinity is low while the correlation between vital offsets and host water Mg/Ca is higher, suggesting that ionic composition of water and/or relative abundance of major ions may also control oxygen isotope fractionation in ostracods. Lack of data on host water ionic composition for the different studies precludes more detailed examination at this stage. Further studies such as natural or laboratory cultures done under strictly controlled conditions are needed to better understand the potential influence of varying environmental condi- tions on oxygen isotope compositions of ostracod valves.
Resumo:
The plutonic rocks of the Basal Complex of La Gomera, Canary Islands, Spain, were studied by means of major and trace element contents and by H-O-Sr-Nd isotope compositions in order to distinguish primary magmatic characteristics and late-stage alteration products. Deciphering the effects of alteration allowed us to determine primary, plume-related compositions that indicated D- and (18)O-depletion relative to normal upper mantle, supporting the conclusions of earlier studies on the plutonic rocks of Fuerteventura and La Palma. Late-stage alteration took place during the formation of the intrusive series induced by interaction with meteoric water. Inferred isotopic compositions of the meteoric water indicate that the water infiltrated into the rock edifice at a height of about 1500 m above sea level, suggesting the existence of a subaerial volcano which was active during the intrusive activity and that it has been either distroyed or remain buried by later volcanic and landslide events.
Resumo:
Superior vena cava (SVC) clamping can be required during thoracic surgery for SVC replacement or repair. In such cases, bypass techniques can be necessary to avoid hemodynamic instability, cerebral venous hypertension and hypoperfusion. Here, we report a novel and simple SVC bypass technique which does not require full systemic heparinization, specialized cannulation techniques or pumping devices and which can be applied percutaneously in the preoperative phase or intraoperatively. The preoperative shunt consisted in two Swan-Ganz catheters inserted in the jugular and femoral veins and connected by perfusion tubing with a three way stopcock. The intraoperative shunt consisted of a Pruitt(®)-catheter inserted in the left innominate vein and connected to a femoral Swan-Ganz catheter by perfusion tubing. We validated our system in seven patients undergoing SVC reconstruction. We monitored the systemic arterial blood pressures, the heart rate and vasoactive peptide requirements throughout the procedure. We also determined the neurological status and the in-hospital morbidity and mortality for each patient. Using this bypass, SVC clamping caused no hemodynamic instability, no neurological impairments and no in-hospital complications or deaths. This simple temporary SVC bypass procedure is safe and avoids hemodynamic instability and cerebral venous hypertension.
Resumo:
Profiles of carbon isotopes were studied in marine limestones of Late Permian and Early Triassic age of the Tethyan region from 20 sections in Yugoslavia, Greece, Turkey, Armenian SSR, Iran, Pakistan, India, Nepal, and China. The Upper Permian sections continue the high positive values of 13C previously found in Upper Permian basins in NW Europe and western USA. In the more complete sections of Tethys it can now be demonstrated that the values of 13C drop from the Murgabian to the Dzhulfian Stages of the Upper Permian, then sharply to values near zero during the last two biozones of the Dorashamian. These levels of 13C sample the Tethys Sea and the world ocean, and equal values from deep-water sediments at Salamis Greece indicate that they apply to the whole water column. We hypothesize that the high values of 13C are a consequence of Late Paleozoic storage of organic carbon, and that the declines represent an episodic cessation of this organic deposition, and partial oxidation of the organic reservoir, extending over a period of several million years. The carbon isotope profile may reflect parallel complexity in the pattern of mass extinction in Late Permian time. Des profils isotopiques du carbone ont été établis dans des calcaires marins d'âge tardi-permien à éo-triasique répartis dans 20 endroits du domaine téthysien: Yougoslavie, Grèce, Turquie, République d'Arménie, Iran, Pakistan, Inde, Népal et Chine. Les profils établis dans le Permien supérieur montrent les mêmes valeurs positives de 13C observées antérieurement dans des bassins de même âge en Europe occidentale et dans l'ouest des USA. Dans les profils les plus complets de la Téthys, il est maintenant établi que les valeurs de 13C décroissent depuis le Murgabien jusqu'au Dzhulfien (Permien supérieur) pour devenir proches de zéro dans les deux dernières biozones du Dorasharmen. Ces valeurs de 13C sont caractéristiques de la Téthys et de l'Océan mondial; elles s'appliquent à toutes les profondeurs d'eau, comme en témoignent les valeurs fournies par des sédiments de mer profonde à Salamis (Grèce). Nous formulons l'hypothèse que les hautes valeurs de 13C sont la conséquence du stockage du carbone organique au Paléozoïque supérieur et que leur décroissance traduit un arrêt épisodique de cette sédimentation organique, accompagné d'une oxydation partielle de la matière organique s'étendant sur une période de plusieurs Ma. L'influence parallèle des phénomènes d'extinction massive à le fin du Permien se refléterait également dans les profils isotopiques du carbone.