342 resultados para image reconstruction
Resumo:
Recent studies at high magnetic fields using the phase of gradient-echo MR images have shown the ability to unveil cortical substructure in the human brain. To investigate the contrast mechanisms in phase imaging, this study extends, for the first time, phase imaging to the rodent brain. Using a 14.1 T horizontal bore animal MRI scanner for in vivo micro-imaging, images with an in-plane resolution of 33 microm were acquired. Phase images revealed, often more clearly than the corresponding magnitude images, hippocampal fields, cortical layers (e.g. layer 4), cerebellar layers (molecular and granule cell layers) and small white matter structures present in the striatum and septal nucleus. The contrast of the phase images depended in part on the orientation of anatomical structures relative to the magnetic field, consistent with bulk susceptibility variations between tissues. This was found not only for vessels, but also for white matter structures, such as the anterior commissure, and cortical layers in the cerebellum. Such susceptibility changes could result from variable blood volume. However, when the deoxyhemoglobin content was reduced by increasing cerebral blood flow (CBF) with a carbogen breathing challenge, contrast between white and gray matter and cortical layers was not affected, suggesting that tissue cerebral blood volume (and therefore deoxyhemoglobin) is not a major source of the tissue phase contrast. We conclude that phase variations in gradient-echo images are likely due to susceptibility shifts of non-vascular origin.
Resumo:
PURPOSE: To compare examination time with radiologist time and to measure radiation dose of computed tomographic (CT) fluoroscopy, conventional CT, and conventional fluoroscopy as guiding modalities for shoulder CT arthrography. MATERIALS AND METHODS: Glenohumeral injection of contrast material for CT arthrography was performed in 64 consecutive patients (mean age, 32 years; age range, 16-74 years) and was guided with CT fluoroscopy (n = 28), conventional CT (n = 14), or conventional fluoroscopy (n = 22). Room times (arthrography, room change, CT, and total examination times) and radiologist times (time the radiologist spent in the fluoroscopy or CT room) were measured. One-way analysis of variance and Bonferroni-Dunn posthoc tests were performed for comparison of mean times. Mean effective radiation dose was calculated for each method with examination data, phantom measurements, and standard software. RESULTS: Mean total examination time was 28.0 minutes for CT fluoroscopy, 28.6 minutes for conventional CT, and 29.4 minutes for conventional fluoroscopy; mean radiologist time was 9.9 minutes, 10.5 minutes, and 9.0 minutes, respectively. These differences were not statistically significant. Mean effective radiation dose was 0.0015 mSv for conventional fluoroscopy (mean, nine sections), 0.22 mSv for CT fluoroscopy (120 kV; 50 mA; mean, 15 sections), and 0.96 mSv for conventional CT (140 kV; 240 mA; mean, six sections). Effective radiation dose can be reduced to 0.18 mSv for conventional CT by changing imaging parameters to 120 kV and 100 mA. Mean effective radiation dose of the diagnostic CT arthrographic examination (140 kV; 240 mA; mean, 25 sections) was 2.4 mSv. CONCLUSION: CT fluoroscopy and conventional CT are valuable alternative modalities for glenohumeral CT arthrography, as examination and radiologist times are not significantly different. CT guidance requires a greater radiation dose than does conventional fluoroscopy, but with adequate parameters CT guidance constitutes approximately 8% of the radiation dose.
Resumo:
The aim of this study was to compare the diagnostic efficiency of plain film and spiral CT examinations with 3D reconstructions of 42 tibial plateau fractures and to assess the accuracy of these two techniques in the pre-operative surgical plan in 22 cases. Forty-two tibial plateau fractures were examined with plain film (anteroposterior, lateral, two obliques) and spiral CT with surface-shaded-display 3D reconstructions. The Swiss AO-ASIF classification system of bone fracture from Muller was used. In 22 cases the surgical plans and the sequence of reconstruction of the fragments were prospectively determined with both techniques, successively, and then correlated with the surgical reports and post-operative plain film. The fractures were underestimated with plain film in 18 of 42 cases (43%). Due to the spiral CT 3D reconstructions, and precise pre-operative information, the surgical plans based on plain film were modified and adjusted in 13 cases among 22 (59%). Spiral CT 3D reconstructions give a better and more accurate demonstration of the tibial plateau fracture and allows a more precise pre-operative surgical plan.
Resumo:
Computed tomography (CT) is used increasingly to measure liver volume in patients undergoing evaluation for transplantation or resection. This study is designed to determine a formula predicting total liver volume (TLV) based on body surface area (BSA) or body weight in Western adults. TLV was measured in 292 patients from four Western centers. Liver volumes were calculated from helical computed tomographic scans obtained for conditions unrelated to the hepatobiliary system. BSA was calculated based on height and weight. Each center used a different established method of three-dimensional volume reconstruction. Using regression analysis, measurements were compared, and formulas correlating BSA or body weight to TLV were established. A linear regression formula to estimate TLV based on BSA was obtained: TLV = -794.41 + 1,267.28 x BSA (square meters; r(2) = 0.46; P <.0001). A formula based on patient weight also was derived: TLV = 191.80 + 18.51 x weight (kilograms; r(2) = 0.49; P <.0001). The newly derived TLV formula based on BSA was compared with previously reported formulas. The application of a formula obtained from healthy Japanese individuals underestimated TLV. Two formulas derived from autopsy data for Western populations were similar to the newly derived BSA formula, with a slight overestimation of TLV. In conclusion, hepatic three-dimensional volume reconstruction based on helical CT predicts TLV based on BSA or body weight. The new formulas derived from this correlation should contribute to the estimation of TLV before liver transplantation or major hepatic resection.
Resumo:
One of the standard tools used to understand the processes shaping trait evolution along the branches of a phylogenetic tree is the reconstruction of ancestral states (Pagel 1999). The purpose is to estimate the values of the trait of interest for every internal node of a phylogenetic tree based on the trait values of the extant species, a topology and, depending on the method used, branch lengths and a model of trait evolution (Ronquist 2004). This approach has been used in a variety of contexts such as biogeography (e.g., Nepokroeff et al. 2003, Blackburn 2008), ecological niche evolution (e.g., Smith and Beaulieu 2009, Evans et al. 2009) and metabolic pathway evolution (e.g., Gabaldón 2003, Christin et al. 2008). Investigations of the factors affecting the accuracy with which ancestral character states can be reconstructed have focused in particular on the choice of statistical framework (Ekman et al. 2008) and the selection of the best model of evolution (Cunningham et al. 1998, Mooers et al. 1999). However, other potential biases affecting these methods, such as the effect of tree shape (Mooers 2004), taxon sampling (Salisbury and Kim 2001) as well as reconstructing traits involved in species diversification (Goldberg and Igić 2008), have also received specific attention. Most of these studies conclude that ancestral character states reconstruction is still not perfect, and that further developments are necessary to improve its accuracy (e.g., Christin et al. 2010). Here, we examine how different estimations of branch lengths affect the accuracy of ancestral character state reconstruction. In particular, we tested the effect of using time-calibrated versus molecular branch lengths and provide guidelines to select the most appropriate branch lengths to reconstruct the ancestral state of a trait.
Resumo:
The trabecular bone score (TBS) is a gray-level textural metric that can be extracted from the two-dimensional lumbar spine dual-energy X-ray absorptiometry (DXA) image. TBS is related to bone microarchitecture and provides skeletal information that is not captured from the standard bone mineral density (BMD) measurement. Based on experimental variograms of the projected DXA image, TBS has the potential to discern differences between DXA scans that show similar BMD measurements. An elevated TBS value correlates with better skeletal microstructure; a low TBS value correlates with weaker skeletal microstructure. Lumbar spine TBS has been evaluated in cross-sectional and longitudinal studies. The following conclusions are based upon publications reviewed in this article: 1) TBS gives lower values in postmenopausal women and in men with previous fragility fractures than their nonfractured counterparts; 2) TBS is complementary to data available by lumbar spine DXA measurements; 3) TBS results are lower in women who have sustained a fragility fracture but in whom DXA does not indicate osteoporosis or even osteopenia; 4) TBS predicts fracture risk as well as lumbar spine BMD measurements in postmenopausal women; 5) efficacious therapies for osteoporosis differ in the extent to which they influence the TBS; 6) TBS is associated with fracture risk in individuals with conditions related to reduced bone mass or bone quality. Based on these data, lumbar spine TBS holds promise as an emerging technology that could well become a valuable clinical tool in the diagnosis of osteoporosis and in fracture risk assessment.
Resumo:
L'Observance est le premier mouvement de réforme avant la Contre-réforme promu par l'Eglise elle-même, dès la fin du XlVème siècle. Visant à restaurer une plus grande observance de la Règle au sein des Ordres religieux, par l'importance accordée à la vie commune, à la formation intellectuelle de ses membres et à l'oraison mentale, elle joue un rôle de premier plan dans la vie des cités au XVème siècle. Tantôt instrument du pouvoir civil tantôt de la papauté, elle est un acteur fondamental dans le panorama urbain, aspirant à contrôler la vie religieuse des laïcs, grâce à ses prédicateurs et son intense activité pastorale, fondée sur l'édition de traités dévotionnels et de manuels pour la prière. L'objet de cette thèse est l'étude des relations entre ce mouvement de réforme religieuse et la production artistique, afin de comprendre la contribution de l'Observance aux transformations importantes que l'image de culte tant publique que privée connaît entre le XVème et le XVIème siècle. Elle montre que l'Observance et les formes de dévotion qu'elle promeut participent non seulement des choix iconographiques mais également formels, et pose la question de l'existence et de la définition d'une esthétique observante. L'analyse se concentre sur la ville de Venise et les Dominicains à partir de 1391, date de l'introduction de l'Observance dans la cité, jusqu'en 1545, qui marque le début du Concile de Trente. La perspective diachronique adoptée a permis de révéler une véritable politique artistique de l'Observance dominicaine, qui fait un usage réfléchi et conscient des images. Celles-ci permettent, d'une part de décliner l'identité de l'Ordre de diverses manières en fonction de la situation religieuse et historique et des destinataires, d'autre part de contrôler et informer la dévotion du fidèle. La perspective diachronique éclaire également comment l'Observance dominicaine a fait face à des mouvements religieux importants, qui promeuvent des pratiques dévotionnelles christocentriques, fondées sur un rapport direct et individuel avec le divin. Il s'agit au XVème siècle de la Devotio moderna, puis au XVIème siècle de la Réforme protestante, mais aussi des divers mouvements de spiritualité évangélique dont Venise est un centre de diffusion. Pour un Ordre voué à la défense de la papauté et de l'Eglise, ces formes de dévotion individuelles constituaient des menaces auxquelles il fallait opposer des formes de dévotion individuelles contrôlées. A cette fin, l'utilisation des images s'est révélée un instrument puissant. Après une première partie historique qui offre une reconstruction de certaines églises dominicaines détruites et établit un corpus d'oeuvres, les rapports de l'Observance et des oeuvres d'art sont analysés selon trois angles d'approche. Le premier se concentre sur la question des femmes, et aborde le problème de l'utilisation des images dans la direction spirituelle des nonnes ainsi que dans la construction d'une identité féminine dominicaine. Le deuxième prend en considération l'utilisation des images dans la dévotion privée des frères eux-mêmes. Le troisième et dernier angle d'approche concerne l'utilisation des images pour définir l'identité de l'Ordre face aux représentants des autorités politiques et religieuses, mais aussi des fidèles.
Resumo:
The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.
Resumo:
Since 1998 the highly polluted Havana Bay ecosystem has been the subject of a mitigation program. In order to determine whether pollution-reduction strategies were effective, we have evaluated the historical trends of pollution recorded in sediments of the Bay. A sediment core was dated radiometrically using natural and artificial fallout radionuclides. An irregularity in the (210)Pb record was caused by an episode of accelerated sedimentation. This episode was dated to occur in 1982, a year coincident with the heaviest rains reported in Havana over the XX century. Peaks of mass accumulation rates (MAR) were associated with hurricanes and intensive rains. In the past 60 years, these maxima are related to strong El Niño periods, which are known to increase rainfall in the north Caribbean region. We observed a steady increase of pollution (mainly Pb, Zn, Sn, and Hg) since the beginning of the century to the mid 90s, with enrichment factors as high as 6. MAR and pollution decreased rapidly after the mid 90s, although some trace metal levels remain high. This reduction was due to the integrated coastal zone management program introduced in the late 90s, which dismissed catchment erosion and pollution.