155 resultados para direct digital radiograph


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this work is to develop a method to objectively compare the performance of a digital and a screen-film mammography system in terms of image quality. The method takes into account the dynamic range of the image detector, the detection of high and low contrast structures, the visualisation of the images and the observer response. A test object, designed to represent a compressed breast, was constructed from various tissue equivalent materials ranging from purely adipose to purely glandular composition. Different areas within the test object permitted the evaluation of low and high contrast detection, spatial resolution and image noise. All the images (digital and conventional) were captured using a CCD camera to include the visualisation process in the image quality assessment. A mathematical model observer (non-prewhitening matched filter), that calculates the detectability of high and low contrast structures using spatial resolution, noise and contrast, was used to compare the two technologies. Our results show that for a given patient dose, the detection of high and low contrast structures is significantly better for the digital system than for the conventional screen-film system studied. The method of using a test object with a large tissue composition range combined with a camera to compare conventional and digital imaging modalities can be applied to other radiological imaging techniques. In particular it could be used to optimise the process of radiographic reading of soft copy images.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Profiling microRNA (miRNA) expression is of widespread interest given the critical role of miRNAs in many cellular functions. Profiling can be achieved via hybridization-based (microarrays), sequencing-based, or amplification-based (quantitative reverse transcription-PCR, qPCR) technologies. Among these, microarrays face the significant challenge of accurately distinguishing between mature and immature miRNA forms, and different vendors have developed different methods to meet this challenge. Here we measure differential miRNA expression using the Affymetrix, Agilent, and Illumina microarray platforms, as well as qPCR (Applied Biosystems) and ultra high-throughput sequencing (Illumina). We show that the differential expression measurements are more divergent when the three types of microarrays are compared than when the Agilent microarray, qPCR, and sequencing technology measurements are compared, which exhibit a good overall concordance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Numerous studies have shown a negative association between birth weight (BW) and blood pressure (BP) later in life. To estimate the direct effect of BW on BP, it is conventional to condition on current weight (CW). However, such conditioning can induce collider stratification bias in the estimate of the direct effect. Objective: To bound the potential bias due to U, an unmeasured common cause of CW and BP, on the estimate of the (controlled) direct effect of BW on BP. Methods: Data from a school based study in Switzerland were used (N = 4,005; 2,010 B/1,995 G; mean age: 12.3 yr [range: 10.1-14.9]). Measured common causes of BW-BP (SES, smoking, body weight, and hypertension status of the mother) and CW-BP (breastfeeding and child's physical activity and diet) were identified with DAGs. Linear regression models were fitted to estimate the association between BW and BP. Sensitivity analyses were conducted to assess the potential effect of U on the association between BW and BP. U was assumed 1) to be a binary variable that affected BP by the same magnitude in low BWand in normal BW children and 2) to have a different prevalence in low BW children and in normal BW children for a given CW. Results: A small negative association was observed between BW and BP [beta: -0.3 mmHg/kg (95% CI: -0.9 to 0.3)]. The association was strengthened upon conditioning for CW [beta: -1.5 mmHg/kg (95% CI: -2.1 to -0.9)]. Upon further conditioning on common causes of BW-BP and CW-BP, the association did not change substantially [beta: -1.4 mmHg/kg (95% CI: -2.0 to -0.8)]. The negative association could be explained by U only if U was strongly associated with BP and if there was a large difference in the prevalence of U between low BWand normal BW children. Conclusion: The observed negative association between BW and BP upon adjustment for CW was not easily explained by an unmeasured common cause of CWand BP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Cervical foraminal injection performed with a direct foraminal approach may induce serious neurologic complications. We describe a technique of CT-guided cervical facet joint (CFJ) injection as an indirect foraminal injection, including feasibility and diffusion pathways of the contrast agent. Methods and materials: Retrospective study included 84 punctures in 65 consecutive patients presenting neck pain and/or radiculopathy related to osteoarthritis or soft disc herniation. CT images were obtained from C2 to T1 in supine position, with a metallic landmark on the skin. CFJ punctures were performed by MSK senior radiologists with a lateral approach. CT control of the CFJ opacification was performed after injections of contrast agent (1 ml), followed by slow-acting corticosteroid (25 mg). CFJ opacification was considered as successful when joint space and/or capsular recess opacification occurred. The diffusion of contrast agent in foraminal and epidural spaces was recorded. We assessed the epidural diffusion both on axial and sagittal images, with a classification in two groups (small diffusion or large diffusion). Results: CFJ opacification was successful in 82% (69/84). An epidural and/or foraminal opacification was obtained in 74% (51/69). A foraminal opacification occurred in 92% (47/51) and an epidural opacification in 63% (32/51), with small diffusion in 47% (15/32) and large diffusion in 53% (17/32). No complication occurred. Conclusion: CT- guided CFJ injection is easy to perform and safe. It is most often successful, with a frequent epidural and/or foraminal diffusion of the contrast agent. This technique could be an interesting and safe alternative to foraminal cervical injection.