166 resultados para accelerometri magnetometri scanner 3D Kinect


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In order to compare coronary magnetic resonance angiography (MRA) data obtained with different scanning methodologies, adequate visualization and presentation of the coronary MRA data need to be ensured. Furthermore, an objective quantitative comparison between images acquired with different scanning methods is desirable. To address this need, a software tool ("Soap-Bubble") that facilitates visualization and quantitative comparison of 3D volume targeted coronary MRA data was developed. In the present implementation, the user interactively specifies a curved subvolume (enclosed in the 3D coronary MRA data set) that closely encompasses the coronary arterial segments. With a 3D Delaunay triangulation and a parallel projection, this enables the simultaneous display of multiple coronary segments in one 2D representation. For objective quantitative analysis, frequently explored quantitative parameters such as signal-to-noise ratio (SNR); contrast-to-noise ratio (CNR); and vessel length, sharpness, and diameter can be assessed. The present tool supports visualization and objective, quantitative comparisons of coronary MRA data obtained with different scanning methods. The first results obtained in healthy adults and in patients with coronary artery disease are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectifs pédagogiques :Savoir comment s'effectue un angio-scanner post-mortem multi-phases.Connaître les compétences du manipulateur forensique.Identifier les nouvelles technologies développées pour cette nouvelle méthode.Connaître les avantages et les limitations de cette technique.Apprendre les difficultés d'interprétation radiologiques des images obtenues.Messages à retenir :L'angio-scanner post-mortem permet de visualiser des pathologies qui ne sont pas visibles lors de l'autopsie , telles que la source exacte d'une hémorragie.L'angio-scanner post-mortem est indiqué pour les cas de mort subite d'origine cardiaque, des décès d'origine traumatique et des décès suites aux interventions médicales.Une nouvelle machine à injection dédiée à cette technique a été développée, qui permet aussi de sauvegarder toutes les données de la perfusion, telles que les différentes courbes de pression et les informations des corps examinés.Grâce à la formation spécifique de manipulateurs forensiques, qui sont capables d'effectuer l'examen de manière autonome, la technique peut être utilisée de façon routinière en médecine légale. L'interprétation radiologique nécessite la connaissance des artéfacts post-mortem pour éviter des interprétations erronées.Résumé :L'angio-scanner combiné à l'autopsie conventionnelle permet d'augmenter la qualité de l'examen post-mortem. L'examen est dirigé par le manipulateurforensique qui gère la machine à perfusion, la préparation du corps et la technique multi-phase. En cours de cette année, une machine à perfusion spécialisée a été développée. L'avantage de cette technique est notamment sa sensibilité supérieure à celle de l'autopsie pour la détection des lésions vasculaires . Les limitations s'expliquent par des artéfacts qui rendent difficile voire impossible l'interprétation de certaines pathologies telles que l'occlusion d'un vaisseau par un thrombus qui est imité par un caillot de sang post-mortem.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Breathing-induced bulk motion of the myocardium during data acquisition may cause severe image artifacts in coronary magnetic resonance angiography (MRA). Current motion compensation strategies include breath-holding or free-breathing MR navigator gating and tracking techniques. Navigator-based techniques have been further refined by the applications of sophisticated 2D k-space reordering techniques. A further improvement in image quality and a reduction of relative scanning duration may be expected from a 3D k-space reordering scheme. Therefore, a 3D k-space reordered acquisition scheme including a 3D navigator gated and corrected segmented k-space gradient echo imaging sequence for coronary MRA was implemented. This new zonal motion-adapted acquisition and reordering technique (ZMART) was developed on the basis of a numerical simulation of the Bloch equations. The technique was implemented on a commercial 1.5T MR system, and first phantom and in vivo experiments were performed. Consistent with the results of the theoretical findings, the results obtained in the phantom studies demonstrate a significant reduction of motion artifacts when compared to conventional (non-k-space reordered) gating techniques. Preliminary in vivo findings also compare favorably with the phantom experiments and theoretical considerations. Magn Reson Med 45:645-652, 2001.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Un système efficace de sismique tridimensionnelle (3-D) haute-résolution adapté à des cibles lacustres de petite échelle a été développé. Dans le Lac Léman, près de la ville de Lausanne, en Suisse, des investigations récentes en deux dimension (2-D) ont mis en évidence une zone de faille complexe qui a été choisie pour tester notre système. Les structures observées incluent une couche mince (<40 m) de sédiments quaternaires sub-horizontaux, discordants sur des couches tertiaires de molasse pentées vers le sud-est. On observe aussi la zone de faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau de la Molasse Subalpine. Deux campagnes 3-D complètes, d?environ d?un kilomètre carré, ont été réalisées sur ce site de test. La campagne pilote (campagne I), effectuée en 1999 pendant 8 jours, a couvert 80 profils en utilisant une seule flûte. Pendant la campagne II (9 jours en 2001), le nouveau système trois-flûtes, bien paramétrés pour notre objectif, a permis l?acquisition de données de très haute qualité sur 180 lignes CMP. Les améliorations principales incluent un système de navigation et de déclenchement de tirs grâce à un nouveau logiciel. Celui-ci comprend un contrôle qualité de la navigation du bateau en temps réel utilisant un GPS différentiel (dGPS) à bord et une station de référence près du bord du lac. De cette façon, les tirs peuvent être déclenchés tous les 5 mètres avec une erreur maximale non-cumulative de 25 centimètres. Tandis que pour la campagne I la position des récepteurs de la flûte 48-traces a dû être déduite à partir des positions du bateau, pour la campagne II elle ont pu être calculées précisément (erreur <20 cm) grâce aux trois antennes dGPS supplémentaires placées sur des flotteurs attachés à l?extrémité de chaque flûte 24-traces. Il est maintenant possible de déterminer la dérive éventuelle de l?extrémité des flûtes (75 m) causée par des courants latéraux ou de petites variations de trajet du bateau. De plus, la construction de deux bras télescopiques maintenant les trois flûtes à une distance de 7.5 m les uns des autres, qui est la même distance que celle entre les lignes naviguées de la campagne II. En combinaison avec un espacement de récepteurs de 2.5 m, la dimension de chaque «bin» de données 3-D de la campagne II est de 1.25 m en ligne et 3.75 m latéralement. L?espacement plus grand en direction « in-line » par rapport à la direction «cross-line» est justifié par l?orientation structurale de la zone de faille perpendiculaire à la direction «in-line». L?incertitude sur la navigation et le positionnement pendant la campagne I et le «binning» imprécis qui en résulte, se retrouve dans les données sous forme d?une certaine discontinuité des réflecteurs. L?utilisation d?un canon à air à doublechambre (qui permet d?atténuer l?effet bulle) a pu réduire l?aliasing observé dans les sections migrées en 3-D. Celui-ci était dû à la combinaison du contenu relativement haute fréquence (<2000 Hz) du canon à eau (utilisé à 140 bars et à 0.3 m de profondeur) et d?un pas d?échantillonnage latéral insuffisant. Le Mini G.I 15/15 a été utilisé à 80 bars et à 1 m de profondeur, est mieux adapté à la complexité de la cible, une zone faillée ayant des réflecteurs pentés jusqu?à 30°. Bien que ses fréquences ne dépassent pas les 650 Hz, cette source combine une pénétration du signal non-aliasé jusqu?à 300 m dans le sol (par rapport au 145 m pour le canon à eau) pour une résolution verticale maximale de 1.1 m. Tandis que la campagne I a été acquise par groupes de plusieurs lignes de directions alternées, l?optimisation du temps d?acquisition du nouveau système à trois flûtes permet l?acquisition en géométrie parallèle, ce qui est préférable lorsqu?on utilise une configuration asymétrique (une source et un dispositif de récepteurs). Si on ne procède pas ainsi, les stacks sont différents selon la direction. Toutefois, la configuration de flûtes, plus courtes que pour la compagne I, a réduit la couverture nominale, la ramenant de 12 à 6. Une séquence classique de traitement 3-D a été adaptée à l?échantillonnage à haute fréquence et elle a été complétée par deux programmes qui transforment le format non-conventionnel de nos données de navigation en un format standard de l?industrie. Dans l?ordre, le traitement comprend l?incorporation de la géométrie, suivi de l?édition des traces, de l?harmonisation des «bins» (pour compenser l?inhomogénéité de la couverture due à la dérive du bateau et de la flûte), de la correction de la divergence sphérique, du filtrage passe-bande, de l?analyse de vitesse, de la correction DMO en 3-D, du stack et enfin de la migration 3-D en temps. D?analyses de vitesse détaillées ont été effectuées sur les données de couverture 12, une ligne sur deux et tous les 50 CMP, soit un nombre total de 600 spectres de semblance. Selon cette analyse, les vitesses d?intervalles varient de 1450-1650 m/s dans les sédiments non-consolidés et de 1650-3000 m/s dans les sédiments consolidés. Le fait que l?on puisse interpréter plusieurs horizons et surfaces de faille dans le cube, montre le potentiel de cette technique pour une interprétation tectonique et géologique à petite échelle en trois dimensions. On distingue cinq faciès sismiques principaux et leurs géométries 3-D détaillées sur des sections verticales et horizontales: les sédiments lacustres (Holocène), les sédiments glacio-lacustres (Pléistocène), la Molasse du Plateau, la Molasse Subalpine de la zone de faille (chevauchement) et la Molasse Subalpine au sud de cette zone. Les couches de la Molasse du Plateau et de la Molasse Subalpine ont respectivement un pendage de ~8° et ~20°. La zone de faille comprend de nombreuses structures très déformées de pendage d?environ 30°. Des tests préliminaires avec un algorithme de migration 3-D en profondeur avant sommation et à amplitudes préservées démontrent que la qualité excellente des données de la campagne II permet l?application de telles techniques à des campagnes haute-résolution. La méthode de sismique marine 3-D était utilisée jusqu?à présent quasi-exclusivement par l?industrie pétrolière. Son adaptation à une échelle plus petite géographiquement mais aussi financièrement a ouvert la voie d?appliquer cette technique à des objectifs d?environnement et du génie civil.<br/><br/>An efficient high-resolution three-dimensional (3-D) seismic reflection system for small-scale targets in lacustrine settings was developed. In Lake Geneva, near the city of Lausanne, Switzerland, past high-resolution two-dimensional (2-D) investigations revealed a complex fault zone (the Paudèze thrust zone), which was subsequently chosen for testing our system. Observed structures include a thin (<40 m) layer of subhorizontal Quaternary sediments that unconformably overlie southeast-dipping Tertiary Molasse beds and the Paudèze thrust zone, which separates Plateau and Subalpine Molasse units. Two complete 3-D surveys have been conducted over this same test site, covering an area of about 1 km2. In 1999, a pilot survey (Survey I), comprising 80 profiles, was carried out in 8 days with a single-streamer configuration. In 2001, a second survey (Survey II) used a newly developed three-streamer system with optimized design parameters, which provided an exceptionally high-quality data set of 180 common midpoint (CMP) lines in 9 days. The main improvements include a navigation and shot-triggering system with in-house navigation software that automatically fires the gun in combination with real-time control on navigation quality using differential GPS (dGPS) onboard and a reference base near the lake shore. Shots were triggered at 5-m intervals with a maximum non-cumulative error of 25 cm. Whereas the single 48-channel streamer system of Survey I requires extrapolation of receiver positions from the boat position, for Survey II they could be accurately calculated (error <20 cm) with the aid of three additional dGPS antennas mounted on rafts attached to the end of each of the 24- channel streamers. Towed at a distance of 75 m behind the vessel, they allow the determination of feathering due to cross-line currents or small course variations. Furthermore, two retractable booms hold the three streamers at a distance of 7.5 m from each other, which is the same distance as the sail line interval for Survey I. With a receiver spacing of 2.5 m, the bin dimension of the 3-D data of Survey II is 1.25 m in in-line direction and 3.75 m in cross-line direction. The greater cross-line versus in-line spacing is justified by the known structural trend of the fault zone perpendicular to the in-line direction. The data from Survey I showed some reflection discontinuity as a result of insufficiently accurate navigation and positioning and subsequent binning errors. Observed aliasing in the 3-D migration was due to insufficient lateral sampling combined with the relatively high frequency (<2000 Hz) content of the water gun source (operated at 140 bars and 0.3 m depth). These results motivated the use of a double-chamber bubble-canceling air gun for Survey II. A 15 / 15 Mini G.I air gun operated at 80 bars and 1 m depth, proved to be better adapted for imaging the complexly faulted target area, which has reflectors dipping up to 30°. Although its frequencies do not exceed 650 Hz, this air gun combines a penetration of non-aliased signal to depths of 300 m below the water bottom (versus 145 m for the water gun) with a maximum vertical resolution of 1.1 m. While Survey I was shot in patches of alternating directions, the optimized surveying time of the new threestreamer system allowed acquisition in parallel geometry, which is preferable when using an asymmetric configuration (single source and receiver array). Otherwise, resulting stacks are different for the opposite directions. However, the shorter streamer configuration of Survey II reduced the nominal fold from 12 to 6. A 3-D conventional processing flow was adapted to the high sampling rates and was complemented by two computer programs that format the unconventional navigation data to industry standards. Processing included trace editing, geometry assignment, bin harmonization (to compensate for uneven fold due to boat/streamer drift), spherical divergence correction, bandpass filtering, velocity analysis, 3-D DMO correction, stack and 3-D time migration. A detailed semblance velocity analysis was performed on the 12-fold data set for every second in-line and every 50th CMP, i.e. on a total of 600 spectra. According to this velocity analysis, interval velocities range from 1450-1650 m/s for the unconsolidated sediments and from 1650-3000 m/s for the consolidated sediments. Delineation of several horizons and fault surfaces reveal the potential for small-scale geologic and tectonic interpretation in three dimensions. Five major seismic facies and their detailed 3-D geometries can be distinguished in vertical and horizontal sections: lacustrine sediments (Holocene) , glaciolacustrine sediments (Pleistocene), Plateau Molasse, Subalpine Molasse and its thrust fault zone. Dips of beds within Plateau and Subalpine Molasse are ~8° and ~20°, respectively. Within the fault zone, many highly deformed structures with dips around 30° are visible. Preliminary tests with 3-D preserved-amplitude prestack depth migration demonstrate that the excellent data quality of Survey II allows application of such sophisticated techniques even to high-resolution seismic surveys. In general, the adaptation of the 3-D marine seismic reflection method, which to date has almost exclusively been used by the oil exploration industry, to a smaller geographical as well as financial scale has helped pave the way for applying this technique to environmental and engineering purposes.<br/><br/>La sismique réflexion est une méthode d?investigation du sous-sol avec un très grand pouvoir de résolution. Elle consiste à envoyer des vibrations dans le sol et à recueillir les ondes qui se réfléchissent sur les discontinuités géologiques à différentes profondeurs et remontent ensuite à la surface où elles sont enregistrées. Les signaux ainsi recueillis donnent non seulement des informations sur la nature des couches en présence et leur géométrie, mais ils permettent aussi de faire une interprétation géologique du sous-sol. Par exemple, dans le cas de roches sédimentaires, les profils de sismique réflexion permettent de déterminer leur mode de dépôt, leurs éventuelles déformations ou cassures et donc leur histoire tectonique. La sismique réflexion est la méthode principale de l?exploration pétrolière. Pendant longtemps on a réalisé des profils de sismique réflexion le long de profils qui fournissent une image du sous-sol en deux dimensions. Les images ainsi obtenues ne sont que partiellement exactes, puisqu?elles ne tiennent pas compte de l?aspect tridimensionnel des structures géologiques. Depuis quelques dizaines d?années, la sismique en trois dimensions (3-D) a apporté un souffle nouveau à l?étude du sous-sol. Si elle est aujourd?hui parfaitement maîtrisée pour l?imagerie des grandes structures géologiques tant dans le domaine terrestre que le domaine océanique, son adaptation à l?échelle lacustre ou fluviale n?a encore fait l?objet que de rares études. Ce travail de thèse a consisté à développer un système d?acquisition sismique similaire à celui utilisé pour la prospection pétrolière en mer, mais adapté aux lacs. Il est donc de dimension moindre, de mise en oeuvre plus légère et surtout d?une résolution des images finales beaucoup plus élevée. Alors que l?industrie pétrolière se limite souvent à une résolution de l?ordre de la dizaine de mètres, l?instrument qui a été mis au point dans le cadre de ce travail permet de voir des détails de l?ordre du mètre. Le nouveau système repose sur la possibilité d?enregistrer simultanément les réflexions sismiques sur trois câbles sismiques (ou flûtes) de 24 traces chacun. Pour obtenir des données 3-D, il est essentiel de positionner les instruments sur l?eau (source et récepteurs des ondes sismiques) avec une grande précision. Un logiciel a été spécialement développé pour le contrôle de la navigation et le déclenchement des tirs de la source sismique en utilisant des récepteurs GPS différentiel (dGPS) sur le bateau et à l?extrémité de chaque flûte. Ceci permet de positionner les instruments avec une précision de l?ordre de 20 cm. Pour tester notre système, nous avons choisi une zone sur le Lac Léman, près de la ville de Lausanne, où passe la faille de « La Paudèze » qui sépare les unités de la Molasse du Plateau et de la Molasse Subalpine. Deux campagnes de mesures de sismique 3-D y ont été réalisées sur une zone d?environ 1 km2. Les enregistrements sismiques ont ensuite été traités pour les transformer en images interprétables. Nous avons appliqué une séquence de traitement 3-D spécialement adaptée à nos données, notamment en ce qui concerne le positionnement. Après traitement, les données font apparaître différents faciès sismiques principaux correspondant notamment aux sédiments lacustres (Holocène), aux sédiments glacio-lacustres (Pléistocène), à la Molasse du Plateau, à la Molasse Subalpine de la zone de faille et la Molasse Subalpine au sud de cette zone. La géométrie 3-D détaillée des failles est visible sur les sections sismiques verticales et horizontales. L?excellente qualité des données et l?interprétation de plusieurs horizons et surfaces de faille montrent le potentiel de cette technique pour les investigations à petite échelle en trois dimensions ce qui ouvre des voies à son application dans les domaines de l?environnement et du génie civil.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We evaluated the performance of an optical camera based prospective motion correction (PMC) system in improving the quality of 3D echo-planar imaging functional MRI data. An optical camera and external marker were used to dynamically track the head movement of subjects during fMRI scanning. PMC was performed by using the motion information to dynamically update the sequence's RF excitation and gradient waveforms such that the field-of-view was realigned to match the subject's head movement. Task-free fMRI experiments on five healthy volunteers followed a 2×2×3 factorial design with the following factors: PMC on or off; 3.0mm or 1.5mm isotropic resolution; and no, slow, or fast head movements. Visual and motor fMRI experiments were additionally performed on one of the volunteers at 1.5mm resolution comparing PMC on vs PMC off for no and slow head movements. Metrics were developed to quantify the amount of motion as it occurred relative to k-space data acquisition. The motion quantification metric collapsed the very rich camera tracking data into one scalar value for each image volume that was strongly predictive of motion-induced artifacts. The PMC system did not introduce extraneous artifacts for the no motion conditions and improved the time series temporal signal-to-noise by 30% to 40% for all combinations of low/high resolution and slow/fast head movement relative to the standard acquisition with no prospective correction. The numbers of activated voxels (p<0.001, uncorrected) in both task-based experiments were comparable for the no motion cases and increased by 78% and 330%, respectively, for PMC on versus PMC off in the slow motion cases. The PMC system is a robust solution to decrease the motion sensitivity of multi-shot 3D EPI sequences and thereby overcome one of the main roadblocks to their widespread use in fMRI studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS AND BACKGROUND: The standard treatment of anal canal cancer (ACC) is combined chemotherapy and radiation therapy (RT), which is complex because of the shape of the target volumes and the need to minimize the irradiation of normal pelvic structures. In this study we compared the dosimetric results of helical tomotherapy (HT) plans with traditional 3D conformal RT (3DRT) plans for the treatment of ACC. METHODS AND STUDY DESIGN: Twelve patients (median age 57 years, range 38-83; F/M 8/4) treated with HT and concurrent chemotherapy for locally advanced ACC were selected. All had histologically confirmed squamous-cell carcinoma. A clinical target volume including the tumor and pelvic and inguinal lymph nodes was treated with HT to a total dose of 36 Gy in 1.8-Gy daily fractions. Then a sequential boost of 23.4 Gy in 1.8-Gy daily fractions (total dose 59.4 Gy) was delivered to the tumor and involved nodes. For all 12 patients, 3DRT plans were generated for comparison. Treatment plans were evaluated by means of standard dose-volume histograms. Dose coverage of the planning target volumes (PTVs), homogeneity index (HI), and mean doses to organs at risk (OARs) were compared. RESULTS: The coverage of PTV was comparable between the two treatment plans. HI was better in the HT vs. 3DRT plans (1.25 and 3.57, respectively; p<0.0001). HT plans resulted in better sparing of OARs (p<0.0001). CONCLUSIONS: HT showed superior target dose conformality and significant sparing of pelvic structures compared with 3DRT. Further investigation should determine if these dosimetric improvements will improve clinical outcomes regarding locoregional control, survival, and treatment-related acute and late morbidity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to investigate the performance of 3D synchrotron differential phase contrast (DPC) imaging for the visualization of both macroscopic and microscopic aspects of atherosclerosis in the mouse vasculature ex vivo. The hearts and aortas of 2 atherosclerotic and 2 wild-type control mice were scanned with DPC imaging with an isotropic resolution of 15 μm. The coronary artery vessel walls were segmented in the DPC datasets to assess their thickness, and histological staining was performed at the level of atherosclerotic plaques. The DPC imaging allowed for the visualization of complex structures such as the coronary arteries and their branches, the thin fibrous cap of atherosclerotic plaques as well as the chordae tendineae. The coronary vessel wall thickness ranged from 37.4 ± 5.6 μm in proximal coronary arteries to 13.6 ± 3.3 μm in distal branches. No consistent differences in coronary vessel wall thickness were detected between the wild-type and atherosclerotic hearts in this proof-of-concept study, although the standard deviation in the atherosclerotic mice was higher in most segments, consistent with the observation of occasional focal vessel wall thickening. Overall, DPC imaging of the cardiovascular system of the mice allowed for a simultaneous detailed 3D morphological assessment of both large structures and microscopic details.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: For free-breathing cardiovascular magnetic resonance (CMR), the self-navigation technique recently emerged, which is expected to deliver high-quality data with a high success rate. The purpose of this study was to test the hypothesis that self-navigated 3D-CMR enables the reliable assessment of cardiovascular anatomy in patients with congenital heart disease (CHD) and to define factors that affect image quality. METHODS: CHD patients ≥2 years-old and referred for CMR for initial assessment or for a follow-up study were included to undergo a free-breathing self-navigated 3D CMR at 1.5T. Performance criteria were: correct description of cardiac segmental anatomy, overall image quality, coronary artery visibility, and reproducibility of great vessels diameter measurements. Factors associated with insufficient image quality were identified using multivariate logistic regression. RESULTS: Self-navigated CMR was performed in 105 patients (55% male, 23 ± 12y). Correct segmental description was achieved in 93% and 96% for observer 1 and 2, respectively. Diagnostic quality was obtained in 90% of examinations, and it increased to 94% if contrast-enhanced. Left anterior descending, circumflex, and right coronary arteries were visualized in 93%, 87% and 98%, respectively. Younger age, higher heart rate, lower ejection fraction, and lack of contrast medium were independently associated with reduced image quality. However, a similar rate of diagnostic image quality was obtained in children and adults. CONCLUSION: In patients with CHD, self-navigated free-breathing CMR provides high-resolution 3D visualization of the heart and great vessels with excellent robustness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Characterizing the geological features and structures in three dimensions over inaccessible rock cliffs is needed to assess natural hazards such as rockfalls and rockslides and also to perform investigations aimed at mapping geological contacts and building stratigraphy and fold models. Indeed, the detailed 3D data, such as LiDAR point clouds, allow to study accurately the hazard processes and the structure of geologic features, in particular in vertical and overhanging rock slopes. Thus, 3D geological models have a great potential of being applied to a wide range of geological investigations both in research and applied geology projects, such as mines, tunnels and reservoirs. Recent development of ground-based remote sensing techniques (LiDAR, photogrammetry and multispectral / hyperspectral images) are revolutionizing the acquisition of morphological and geological information. As a consequence, there is a great potential for improving the modeling of geological bodies as well as failure mechanisms and stability conditions by integrating detailed remote data. During the past ten years several large rockfall events occurred along important transportation corridors where millions of people travel every year (Switzerland: Gotthard motorway and railway; Canada: Sea to sky highway between Vancouver and Whistler). These events show that there is still a lack of knowledge concerning the detection of potential rockfalls, making mountain residential settlements and roads highly risky. It is necessary to understand the main factors that destabilize rocky outcrops even if inventories are lacking and if no clear morphological evidences of rockfall activity are observed. In order to increase the possibilities of forecasting potential future landslides, it is crucial to understand the evolution of rock slope stability. Defining the areas theoretically most prone to rockfalls can be particularly useful to simulate trajectory profiles and to generate hazard maps, which are the basis for land use planning in mountainous regions. The most important questions to address in order to assess rockfall hazard are: Where are the most probable sources for future rockfalls located? What are the frequencies of occurrence of these rockfalls? I characterized the fracturing patterns in the field and with LiDAR point clouds. Afterwards, I developed a model to compute the failure mechanisms on terrestrial point clouds in order to assess the susceptibility to rockfalls at the cliff scale. Similar procedures were already available to evaluate the susceptibility to rockfalls based on aerial digital elevation models. This new model gives the possibility to detect the most susceptible rockfall sources with unprecented detail in the vertical and overhanging areas. The results of the computation of the most probable rockfall source areas in granitic cliffs of Yosemite Valley and Mont-Blanc massif were then compared to the inventoried rockfall events to validate the calculation methods. Yosemite Valley was chosen as a test area because it has a particularly strong rockfall activity (about one rockfall every week) which leads to a high rockfall hazard. The west face of the Dru was also chosen for the relevant rockfall activity and especially because it was affected by some of the largest rockfalls that occurred in the Alps during the last 10 years. Moreover, both areas were suitable because of their huge vertical and overhanging cliffs that are difficult to study with classical methods. Limit equilibrium models have been applied to several case studies to evaluate the effects of different parameters on the stability of rockslope areas. The impact of the degradation of rockbridges on the stability of large compartments in the west face of the Dru was assessed using finite element modeling. In particular I conducted a back-analysis of the large rockfall event of 2005 (265'000 m3) by integrating field observations of joint conditions, characteristics of fracturing pattern and results of geomechanical tests on the intact rock. These analyses improved our understanding of the factors that influence the stability of rock compartments and were used to define the most probable future rockfall volumes at the Dru. Terrestrial laser scanning point clouds were also successfully employed to perform geological mapping in 3D, using the intensity of the backscattered signal. Another technique to obtain vertical geological maps is combining triangulated TLS mesh with 2D geological maps. At El Capitan (Yosemite Valley) we built a georeferenced vertical map of the main plutonio rocks that was used to investigate the reasons for preferential rockwall retreat rate. Additional efforts to characterize the erosion rate were made at Monte Generoso (Ticino, southern Switzerland) where I attempted to improve the estimation of long term erosion by taking into account also the volumes of the unstable rock compartments. Eventually, the following points summarize the main out puts of my research: The new model to compute the failure mechanisms and the rockfall susceptibility with 3D point clouds allows to define accurately the most probable rockfall source areas at the cliff scale. The analysis of the rockbridges at the Dru shows the potential of integrating detailed measurements of the fractures in geomechanical models of rockmass stability. The correction of the LiDAR intensity signal gives the possibility to classify a point cloud according to the rock type and then use this information to model complex geologic structures. The integration of these results, on rockmass fracturing and composition, with existing methods can improve rockfall hazard assessments and enhance the interpretation of the evolution of steep rockslopes. -- La caractérisation de la géologie en 3D pour des parois rocheuses inaccessibles est une étape nécessaire pour évaluer les dangers naturels tels que chutes de blocs et glissements rocheux, mais aussi pour réaliser des modèles stratigraphiques ou de structures plissées. Les modèles géologiques 3D ont un grand potentiel pour être appliqués dans une vaste gamme de travaux géologiques dans le domaine de la recherche, mais aussi dans des projets appliqués comme les mines, les tunnels ou les réservoirs. Les développements récents des outils de télédétection terrestre (LiDAR, photogrammétrie et imagerie multispectrale / hyperspectrale) sont en train de révolutionner l'acquisition d'informations géomorphologiques et géologiques. Par conséquence, il y a un grand potentiel d'amélioration pour la modélisation d'objets géologiques, ainsi que des mécanismes de rupture et des conditions de stabilité, en intégrant des données détaillées acquises à distance. Pour augmenter les possibilités de prévoir les éboulements futurs, il est fondamental de comprendre l'évolution actuelle de la stabilité des parois rocheuses. Définir les zones qui sont théoriquement plus propices aux chutes de blocs peut être très utile pour simuler les trajectoires de propagation des blocs et pour réaliser des cartes de danger, qui constituent la base de l'aménagement du territoire dans les régions de montagne. Les questions plus importantes à résoudre pour estimer le danger de chutes de blocs sont : Où se situent les sources plus probables pour les chutes de blocs et éboulement futurs ? Avec quelle fréquence vont se produire ces événements ? Donc, j'ai caractérisé les réseaux de fractures sur le terrain et avec des nuages de points LiDAR. Ensuite, j'ai développé un modèle pour calculer les mécanismes de rupture directement sur les nuages de points pour pouvoir évaluer la susceptibilité au déclenchement de chutes de blocs à l'échelle de la paroi. Les zones sources de chutes de blocs les plus probables dans les parois granitiques de la vallée de Yosemite et du massif du Mont-Blanc ont été calculées et ensuite comparés aux inventaires des événements pour vérifier les méthodes. Des modèles d'équilibre limite ont été appliqués à plusieurs cas d'études pour évaluer les effets de différents paramètres sur la stabilité des parois. L'impact de la dégradation des ponts rocheux sur la stabilité de grands compartiments de roche dans la paroi ouest du Petit Dru a été évalué en utilisant la modélisation par éléments finis. En particulier j'ai analysé le grand éboulement de 2005 (265'000 m3), qui a emporté l'entier du pilier sud-ouest. Dans le modèle j'ai intégré des observations des conditions des joints, les caractéristiques du réseau de fractures et les résultats de tests géoméchaniques sur la roche intacte. Ces analyses ont amélioré l'estimation des paramètres qui influencent la stabilité des compartiments rocheux et ont servi pour définir des volumes probables pour des éboulements futurs. Les nuages de points obtenus avec le scanner laser terrestre ont été utilisés avec succès aussi pour produire des cartes géologiques en 3D, en utilisant l'intensité du signal réfléchi. Une autre technique pour obtenir des cartes géologiques des zones verticales consiste à combiner un maillage LiDAR avec une carte géologique en 2D. A El Capitan (Yosemite Valley) nous avons pu géoréferencer une carte verticale des principales roches plutoniques que j'ai utilisé ensuite pour étudier les raisons d'une érosion préférentielle de certaines zones de la paroi. D'autres efforts pour quantifier le taux d'érosion ont été effectués au Monte Generoso (Ticino, Suisse) où j'ai essayé d'améliorer l'estimation de l'érosion au long terme en prenant en compte les volumes des compartiments rocheux instables. L'intégration de ces résultats, sur la fracturation et la composition de l'amas rocheux, avec les méthodes existantes permet d'améliorer la prise en compte de l'aléa chute de pierres et éboulements et augmente les possibilités d'interprétation de l'évolution des parois rocheuses.