454 resultados para Synthetic aperture imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This review describes the advances in malaria antigen discovery and vaccine development using the long synthetic peptide platforms that have been made available during the past 5 years. The most recent technical developments regarding peptide synthesis with the optimized production of large synthetic fragments are discussed. Clinical trials of long synthetic peptides are also reviewed. These trials demonstrated that long synthetic peptides are safe and immunogenic when formulated with various adjuvants. In addition, long synthetic peptides can elicit an antibody response in humans and have demonstrated inhibitory activity against parasite growth in vitro. Finally, new approaches to exploit the abundance of genomic data and the flexibility and speed of peptide synthesis are proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postmortem imaging, including postmortem computed tomography angiography, has become an integral tool in forensic investigation in recent years. A relatively new technique, multiphase postmortem computed tomography angiography, allows detailed visualization of the vascular system and makes it possible to evaluate the dynamic perfusion of aortic branches, including the coronary arteries. Here, we report a case of aortic dissection involving the ascending aorta (type A) with coronary and carotid malperfusion. This case illustrates the complementary use of many of the diagnostic tools that are now available in forensic practice, from imaging to conventional autopsy to pathologic techniques such as immunohistochemistry.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumor Endothelial Marker-1 (TEM1/CD248) is a tumor vascular marker with high therapeutic and diagnostic potentials. Immuno-imaging with TEM1-specific antibodies can help to detect cancerous lesions, monitor tumor responses, and select patients that are most likely to benefit from TEM1-targeted therapies. In particular, near infrared(NIR) optical imaging with biomarker-specific antibodies can provide real-time, tomographic information without exposing the subjects to radioactivity. To maximize the theranostic potential of TEM1, we developed a panel of all human, multivalent Fc-fusion proteins based on a previously identified single chain antibody (scFv78) that recognizes both human and mouse TEM1. By characterizing avidity, stability, and pharmacokinectics, we identified one fusion protein, 78Fc, with desirable characteristics for immuno-imaging applications. The biodistribution of radiolabeled 78Fc showed that this antibody had minimal binding to normal organs, which have low expression of TEM1. Next, we developed a 78Fc-based tracer and tested its performance in different TEM1-expressing mouse models. The NIR imaging and tomography results suggest that the 78Fc-NIR tracer performs well in distinguishing mouse- or human-TEM1 expressing tumor grafts from normal organs and control grafts in vivo. From these results we conclude that further development and optimization of 78Fc as a TEM1-targeted imaging agent for use in clinical settings is warranted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 41-year-old male presented with severe frostbite that was monitored clinically and with a new laser Doppler imaging (LDI) camera that records arbitrary microcirculatory perfusion units (1-256 arbitrary perfusion units (APU's)). LDI monitoring detected perfusion differences in hand and foot not seen visually. On day 4-5 after injury, LDI showed that while fingers did not experience any significant perfusion change (average of 31±25 APUs on day 5), the patient's left big toe did (from 17±29 APUs day 4 to 103±55 APUs day 5). These changes in regional perfusion were not detectable by visual examination. On day 53 postinjury, all fingers with reduced perfusion by LDI were amputated, while the toe could be salvaged. This case clearly demonstrates that insufficient microcirculatory perfusion can be identified using LDI in ways which visual examination alone does not permit, allowing prognosis of clinical outcomes. Such information may also be used to develop improved treatment approaches.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AbstractFor a wide range of environmental, hydrological, and engineering applications there is a fast growing need for high-resolution imaging. In this context, waveform tomographic imaging of crosshole georadar data is a powerful method able to provide images of pertinent electrical properties in near-surface environments with unprecedented spatial resolution. In contrast, conventional ray-based tomographic methods, which consider only a very limited part of the recorded signal (first-arrival traveltimes and maximum first-cycle amplitudes), suffer from inherent limitations in resolution and may prove to be inadequate in complex environments. For a typical crosshole georadar survey the potential improvement in resolution when using waveform-based approaches instead of ray-based approaches is in the range of one order-of- magnitude. Moreover, the spatial resolution of waveform-based inversions is comparable to that of common logging methods. While in exploration seismology waveform tomographic imaging has become well established over the past two decades, it is comparably still underdeveloped in the georadar domain despite corresponding needs. Recently, different groups have presented finite-difference time-domain waveform inversion schemes for crosshole georadar data, which are adaptations and extensions of Tarantola's seminal nonlinear generalized least-squares approach developed for the seismic case. First applications of these new crosshole georadar waveform inversion schemes on synthetic and field data have shown promising results. However, there is little known about the limits and performance of such schemes in complex environments. To this end, the general motivation of my thesis is the evaluation of the robustness and limitations of waveform inversion algorithms for crosshole georadar data in order to apply such schemes to a wide range of real world problems.One crucial issue to making applicable and effective any waveform scheme to real-world crosshole georadar problems is the accurate estimation of the source wavelet, which is unknown in reality. Waveform inversion schemes for crosshole georadar data require forward simulations of the wavefield in order to iteratively solve the inverse problem. Therefore, accurate knowledge of the source wavelet is critically important for successful application of such schemes. Relatively small differences in the estimated source wavelet shape can lead to large differences in the resulting tomograms. In the first part of my thesis, I explore the viability and robustness of a relatively simple iterative deconvolution technique that incorporates the estimation of the source wavelet into the waveform inversion procedure rather than adding additional model parameters into the inversion problem. Extensive tests indicate that this source wavelet estimation technique is simple yet effective, and is able to provide remarkably accurate and robust estimates of the source wavelet in the presence of strong heterogeneity in both the dielectric permittivity and electrical conductivity as well as significant ambient noise in the recorded data. Furthermore, our tests also indicate that the approach is insensitive to the phase characteristics of the starting wavelet, which is not the case when directly incorporating the wavelet estimation into the inverse problem.Another critical issue with crosshole georadar waveform inversion schemes which clearly needs to be investigated is the consequence of the common assumption of frequency- independent electromagnetic constitutive parameters. This is crucial since in reality, these parameters are known to be frequency-dependent and complex and thus recorded georadar data may show significant dispersive behaviour. In particular, in the presence of water, there is a wide body of evidence showing that the dielectric permittivity can be significantly frequency dependent over the GPR frequency range, due to a variety of relaxation processes. The second part of my thesis is therefore dedicated to the evaluation of the reconstruction limits of a non-dispersive crosshole georadar waveform inversion scheme in the presence of varying degrees of dielectric dispersion. I show that the inversion algorithm, combined with the iterative deconvolution-based source wavelet estimation procedure that is partially able to account for the frequency-dependent effects through an "effective" wavelet, performs remarkably well in weakly to moderately dispersive environments and has the ability to provide adequate tomographic reconstructions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new method for oxidative folding of synthetic polypeptides assembled by stepwise solid phase synthesis is introduced. Folding is obtained in excellent yields by reacting S-tert-butylthiolated polypeptides with a 100-fold molar excess of cysteine at 37 degrees C in a slightly alkaline buffer containing chaotropic salts, and in the presence of air-oxygen. This novel protocol has been applied to the folding of S-tert-butylthiolated human thymus and activation-regulated chemokine (hu-TARC) derivatives as well as to larger segments of Plasmodium falciparum and Plasmodium berghei circumsporozoite proteins. Folded P. falciparum polypeptides have been used as substrates of endoproteinase Glu-C (Glu-C) and endoproteinase Asp-N (Asp-N) in an attempt to identify their disulfide connectivities. Particular practical advantages of the present method are (i) easy purification and storage of the S-protected peptide derivatives, (ii) elimination of the risk of cysteine alkylation during the acidolytic cleavage deprotection and resin cleavage steps, (iii) possibility to precisely evaluate the extent of folding and disulfide bond formation by mass spectrometry, and (iv) facile recovery of the final folded product.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: To determine the long-term prognostic value of SPECT myocardial perfusion imaging (MPI) for the occurrence of cardiovascular events in diabetic patients. PATIENTS, METHODS: SPECT MPI of 210 consecutive Caucasian diabetic patients were analysed using Kaplan-Meier event-free survival curves and independent predictors were determined by Cox multivariate analyses. RESULTS: Follow-up was complete in 200 (95%) patients with a median period of 3.0 years (0.8-5.0). The population was composed of 114 (57%) men, age 65 +/- 10 years, 181 (90.5%) type 2 diabetes mellitus, 50 (25%) with a history of coronary artery disease (CAD) and 98 (49%) presenting chest pain prior to MPI. The prevalence of abnormal MPI was 58%. Patients with a normal MPI had neither cardiac death, nor myocardial infarction, independently of a history of coronary artery disease or chest pain. Among the independent predictors of cardiac death and myocardial infarction, the strongest was abnormal MPI (p < 0.0001), followed by history of CAD (Hazard Ratio (HR) = 15.9; p = 0.0001), diabetic retinopathy (HR = 10.0; p = 0.001) and inability to exercise (HR = 7.7; p = 0.02). Patients with normal MPI had a low revascularisation rate of 2.4% during the follow-up period. Compared to normal MPI, cardiovascular events increased 5.2 fold for reversible defects, 8.5 fold for fixed defects and 20.1 fold for the association of both defects. CONCLUSION: Diabetic patients with normal MPI had an excellent prognosis independently of history of CAD. On the opposite, an abnormal MPI led to a >5-fold increase in cardiovascular events. This emphasizes the value of SPECT MPI in predicting and risk-stratifying cardiovascular events in diabetic patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the assessment of medical malpractice imaging methods can be used for the documentation of crucial morphological findings which are indicative for or against an iatrogenically caused injury. The clarification of deaths in this context can be usefully supported by postmortem imaging (primarily native computed tomography, angiography, magnetic resonance imaging). Postmortem imaging offers significant additional information compared to an autopsy in the detection of iatrogenic air embolisms and documentation of misplaced medical aids before dissection with an inherent danger of relocation. Additional information is supplied by postmortem imaging in the search for sources of bleeding as well as the documentation of perfusion after cardiovascular surgery. Key criteria for the decision to perform postmortem imaging can be obtained from the necessary preliminary inspection of clinical documentation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of RGD-based antagonist of αvβ3 integrin receptor has enhanced the interest in PET probes to image this receptor for the early detection of cancer, to monitor the disease progression and the response to therapy. In this work, a novel prosthetic group (N-(4-fluorophenyl)pent-4-ynamide or FPPA) for the (18)F-labeling of an αvβ3 selective RGD-peptide was successfully prepared. [(18)F]FPPA was obtained in three steps with a radiochemical yield of 44% (decay corrected). Conjugation to c(RGDfK(N3)) by the Cu(II) catalyzed Huisgen azido alkyne cycloaddition provided the [(18)F]FPPA-c(RGDfK) with a radiochemical yield of 29% (decay corrected), in an overall synthesis time of 140min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Papez circuit is one of the major pathways of the limbic system, and it is involved in the control of memory and emotion. Structural and functional alterations have been reported in psychiatric, neurodegenerative, and epileptic diseases. Despite the clinical interest, however, in-vivo imaging of the entire circuit remains a technological challenge. We used magnetic resonance diffusion spectrum imaging to comprehensively picture the Papez circuit in healthy humans: (i) the hippocampus-mammillary body pathway, (ii) the connections between the lateral subiculum and the cingulate cortex, and (iii) the mammillo-thalamic tract. The diagnostic and therapeutic implications of these results are discussed in the context of recent findings reporting the involvement of the Papez circuit in neurological and psychiatric diseases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The circumsporozoite (CS) protein is a major malaria sporozoite surface antigen currently being considered as vaccine candidate. Plasmodium vivax CS (PvCS) protein comprises a dimorphic central repeat fragment flanked by conserved regions that contain functional domains involved in parasite invasion of host cells. The protein amino (N-terminal) flank has a cleavage region (region I), essential for proteolytic processing prior to parasite invasion of liver cells. METHODS: We have developed a 131-mer long synthetic polypeptide (LSP) named PvNR1R2 that includes the N-terminal flank and the two natural repeat variant regions known as VK210 and VK247. We studied the natural immune response to this region in human sera from different malaria-endemic areas and its immunogenicity in mice. RESULTS: PvNR1R2 was more frequently recognized by sera from Papua New Guinea (PNG) (83%) than by samples from Colombia (24%) when tested by ELISA. The polypeptide formulated in Montanide ISA51 adjuvant elicited strong antibody responses in both C3H and CB6F1 mice strains. Antibodies from immunized mice as well as affinity-purified human IgG reacted with native protein by IFA test. Moreover, mouse immune sera induced strong (90%) in vitro inhibition of sporozoite invasion (ISI) of hepatoma cell lines. CONCLUSIONS: These results encourage further studies in non-human primates to confirm the elicitation of sporozoite invasion blocking antibodies, to assess cell mediated immune responses and the protective efficacy of this polypeptide.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis of idiopathic Parkinson's disease (IPD) is entirely clinical. The fact that neuronal damage begins 5-10 years before occurrence of sub-clinical signs, underlines the importance of preclinical diagnosis. A new approach for in-vivo pathophysiological assessment of IPD-related neurodegeneration was implemented based on recently developed neuroimaging methods. It is based on non- invasive magnetic resonance data sensitive to brain tissue property changes that precede macroscopic atrophy in the early stages of IPD. This research aims to determine the brain tissue property changes induced by neurodegeneration that can be linked to clinical phenotypes which will allow us to create a predictive model for early diagnosis in IPD. We hypothesized that the degree of disease progression in IPD patients will have a differential and specific impact on brain tissue properties used to create a predictive model of motor and non-motor impairment in IPD. We studied the potential of in-vivo quantitative imaging sensitive to neurodegeneration- related brain tissue characteristics to detect changes in patients with IPD. We carried out methodological work within the well established SPM8 framework to estimate the sensitivity of tissue probability maps for automated tissue classification for detection of early IPD. We performed whole-brain multi parameter mapping at high resolution followed by voxel-based morphometric (VBM) analysis and voxel-based quantification (VBQ) comparing healthy subjects to IPD patients. We found a trend demonstrating non-significant tissue property changes in the olfactory bulb area using the MT and R1 parameter with p<0.001. Comparing to the IPD patients, the healthy group presented a bilateral higher MT and R1 intensity in this specific functional region. These results did not correlate with age, severity or duration of disease. We failed to demonstrate any changes with the R2* parameter. We interpreted our findings as demyelination of the olfactory tract, which is clinically represented as anosmia. However, the lack of correlation with duration or severity complicates its implications in the creation of a predictive model of impairment in IPD.