300 resultados para Pressure range
Resumo:
OBJECTIVE: An inverse relationship between blood pressure (BP) and cognitive function has been found in adults, but limited data are available in adolescents and young adults. We examined the prospective relation between BP and cognitive function in adolescence. METHODS: We examined the association between BP measured at the ages of 12-15 years in school surveys and cognitive endpoints measured in the Seychelles Child Development Study at ages 17 (n = 407) and 19 (n = 429) years, respectively. We evaluated multiple domains of cognition based on subtests of the Cambridge Neurological Test Automated Battery (CANTAB), the Woodcock Johnson Test of Scholastic Achievement (WJTA), the Finger Tapping test (FT) and the Kaufman Brief Intelligence Test (K-BIT). We used age, sex and height-specific z-scores of SBP, DBP and mean arterial pressure (MAP). RESULTS: Six out of the 21 cognitive endpoints tested were associated with BP. However, none of these associations were found to hold for both males and females or for different subtests within the same neurodevelopmental domain or for both SBP and DBP. Most of these associations disappeared when analyses were adjusted for selected potential confounding factors such as socio-economic status, birth weight, gestational age, BMI, alcohol consumption, blood glucose, and total n-3 and n-6 polyunsaturated fats. CONCLUSIONS: Our findings do not support a consistent association between BP and subsequent performance on tests assessing various cognitive domains in adolescents.
Resumo:
BACKGROUND: Peer pressure is regarded as an important determinant of substance use, sexual behavior and juvenile delinquency. However, few peer pressure scales are validated, especially in French or German. Little is known about the factor structure of such scales or the kind of scale needed: some scales takes into account both peer pressure to do and peer pressure not to do, while others consider only peer pressure to do. The aim of the present study was to adapt French and German versions of the Peer Pressure Inventory, which is one of the most widely used scales in this field. We considered its factor structure and concurrent validity. METHODS: Five thousand eight hundred and sixty-seven young Swiss men filled in a questionnaire on peer pressure, substance use, and other variables (conformity, involvement) in a cohort study. RESULTS: We identified a four-factor structure, with the three factors of the initial Peer Pressure Inventory (involvement, conformity, misconduct) and adding a new one (relationship with girls). A non-valued scale (from no peer pressure to peer pressure to do only) showed stronger psychometric qualities than a valued scale (from peer pressure not to do to peer pressure to do). Concurrent validity was also good. Each behavior or attitude was significantly associated with peer pressure. CONCLUSION: Peer pressure seems to be a multidimensional concept. In this study, peer pressure to do showed the strongest influence on participants. Indeed, peer pressure not to do did not add anything useful. Only peer pressure to do affected young Swiss men's behaviors and attitudes and was reliable.
Resumo:
Introduction: Nasal continuous positive airways pressure (n-CPAP) is an effective treatment in premature infants with respiratory distress. The cardio-pulmonary interactions secondary to n-CPAP are well studied in adults, but less well described in premature infants. We postulated that there could be important interactions with regard to the patent ductus arteriosus (PDA). Methods: Prospective study, approved by the local ethic committee. Premature infants less than 32 weeks gestation, _7 days-old, needing n-CPAP for respiratory distress, but without the need of additional oxygen were included in the study. Every patient had a first echocardiography with n-CPAP and then n-CPAP was retrieved. 3 hours later the echocardiography was repeated by the same investigator and then the patient replaced on n-CPAP. Results: 14 premature newborn were included, mean gestational age of 28 _ 2 weeks, mean weight 1.1 _ 0.3 Kg and height 39 _ 3 cm. Echocardiographic measurements are depicted in Table 1. Significant finding were observed between measurement on n- CPAP or without n-CPAP: on end diastolic left ventricular diameter (12.8 _ 1.6 mm vs. 13.5 _ 2 mm), on end systolic left ventricular diameter (8.4 _ 1.3 mm vs. 9.1 _ 1.5 mm), left atrium diameter (8.9 _ 2.2 mm vs. 10.4 _ 2.5 mm), maximal velocity on tricuspid valve (46 _ 10 cm/s vs. 51 _ 9 cm/s), calculated Qp (3.7 _ 0.8 L/min/m2 vs. 4.3 _ 0.8 L/min/m2). Only three patients have demonstrated a PDA during the study. Conclusion: Positive end expiratory pressure (Peep) has hemodynamic effects which are: reduction of systemic and pulmonary venous return as shown by the changes on tricuspid valve inflow,on the calculated Qp and finally on the diameter of the left atrium and left ventricle.We found in premature infants the same hemodynamic effects than those described in adults but with lower Peep values. This could be due to the particular elasticity and weakness of the thoracic wall of premature infants. Interestingly the flow through a PDA seems also to be diminished with Peep, but the number of patients is insufficient to conclude. Further investigation will be needed to better understand these interactions. Table 1. Echocardiographic measurement (mean (SD)). With n-CPAP Without n-CPAP p value RV ED diameter (mm) 6.3 (1.7) 6.04 (1.1) NS LV ED diameter (mm) 12.8 (1.6) 13.5 (2.0) _0.05 LV ES diameter (mm) 8.4 (1.3) 9.1 (1.5) _0.05 SF (%) 34 (5) 33 (6) NS Ao valve diameter (mm) 7.4 (1.3) 7.4 (1.2) NS LA diameter (mm) 8.9 (2.2) 10.4 (2.5) _0.05 Vmax Ao (cm/s) 70 (16) 71 (18) NS Vmax PV (cm/s) 69 (15) 72 (16) NS Vmax TV (cm/s) 46 (10) 51 (9) _0.05 Vmax MV (cm/s) 53 (17) 54 (18) NS Qp (L/min/m2) 3.7 (0.8) 4.3 (0.8) _0.05 Qs (L/min/m2) 4.0 (0.8) 4.0 (0.7) NS Qp/Qs 0.92 (0.14) 1.09 (0.23) _0.05 RV: right ventricle, LV: left ventricle, ED: end diastolic, ES: end systolic, SF: shortening fraction,Ao: aortic valve, LA: left atrium,Vmax: maximum Doppler Velocity, Qp: pulmonary output, Qs: systemic output, NS: non significant.
Resumo:
Exposure to fine particles and noise has been linked to cardiovascular diseases and elevated cardiovascular mortality affecting the worldwide population. Residence and/or work in proximity to emission sources as for example road traffic leads to an elevated exposure and a higher risk for adverse health effects. Highway maintenance workers spend most of their work time in traffic and are exposed regularly to particles and noise. The aims of this thesis were to provide a better understanding of the workers' mixed exposure to particles and noise and to assess cardiopulmonary short term health effects in relation to this exposure. Exposure and health data were collected in collaboration with 8 maintenance centers of the Swiss Road Maintenance Services located in the cantons Bern, Fribourg and Vaud in western Switzerland. Repeated measurements with 18 subjects were conducted during 50 non-consecutive work shifts between Mai 2010 and February 2012, equally distributed over all seasons. In the first part of this thesis we tested and validated measurements of ultrafine particles with a miniature diffusion size classifier (miniDiSC) - a novel particle counting device that was used for the exposure assessment during highway maintenance work. We found that particle numbers and average particle size measured by the miniDiSC were highly correlated with data from the P-TRAK, a condensation particle counter (CPC), as well as from a scanning mobility particle sizer (SMPS). However, the miniDiSC measured significantly more particles than the P-TRAK and significantly less than the SMPS in its full size range. Our data suggests that the instrument specific cutoffs were the main reason for the different particle counts. The first main objective of this thesis was to investigate the exposure of highway maintenance workers to air pollutants and noise, in relation to the different maintenance activities. We have seen that the workers are regularly exposed to high particle and noise levels. This was a consequence of close proximity to highway traffic and the use of motorized working equipment such as brush cutters, chain saws, generators and pneumatic hammers during which the highest exposure levels occurred. Although exposure to air pollutants were not critical if compared to occupational exposure limits, the elevated exposure to particles and noise may lead to a higher risk for cardiovascular diseases in this worker population. The second main objective was to investigate cardiopulmonary short-term health effects in relation to the particle and noise exposure during highway maintenance work. We observed a PM2.5 related increase of the acute-phase inflammation markers C-reactive protein and serum amyloid A and a decrease of TNFa. Heart rate variability increased as a consequence of particle as well as noise exposure. Increased high frequency power indicated a stronger parasympathetic influence on the heart. Elevated noise levels during recreational time, after work, were related to increased blood pressure. Our data confirmed that highway maintenance workers are exposed to elevated levels of particles and noise as compared to the average population. This exposure poses a cardiovascular health risk and it is therefore important to make efforts to better protect the workers health. The use of cleaner machines during maintenance work would be a major step to improve the workers' situation. Furthermore, regulatory policies with the aim of reducing combustion and non-combustion emissions from road traffic are important for the protection of workers in traffic environments and the entire population.
Resumo:
We estimated the heritability of ambulatory systolic blood pressure (SBP), diastolic blood pressure (DBP), and pulse pressure (PP) in east African families with at least 2 hypertensive siblings and living in the Seychelles islands (Indian Ocean). The sample consisted of 314 individuals (147 men and 167 women), both normotensive and hypertensive, from 76 pedigrees (mean+/-SD of 4.1+/-2.8 persons per pedigree). After a 2-week off-treatment period, daytime and nighttime ambulatory blood pressure (BP) was monitored. Office BP was measured with a standard mercury sphygmomanometer. We estimated by maximum likelihood the age- and sex-adjusted heritabilities from the additive polygenic component of the variance of the traits allowing for the presence of other familial correlations. We also adjusted for ascertainment (ie, for the fact that 2 siblings had to be hypertensive) and examined the effect of adjusting for body mass index, 24-hour urinary excretion of sodium and potassium, plasma renin activity, and plasma aldosterone concentration. Heritability estimates (+/-SE) for ambulatory SBP, DBP, and PP were, respectively, 0.37+/-0.12/0.24+/-0.12/0.54+/-0.12 for daytime and 0.34+/-0.13/ 0.37+/-0.15/0.47+/-0.12 for nighttime measurements (P<0.05 for all estimates). Heritability estimates for office SBP, DBP, and PP were, respectively, 0.20+/-0.11, 0.05+/-0.09, and 0.37+/-0.12. Heritability estimates for SBP varied markedly according to whether participants were treated for hypertension at baseline. The present data show that ambulatory BP and PP have a high heritability in families of African descent. They also demonstrate that antihypertensive treatment and the number of BP measurements have a major influence on the heritability estimates.
Resumo:
The distribution range of Lactuca serriola, a species native to the summer-dry mediterranean climate, has expanded northwards during the last 250 years. This paper assesses the influence of climate on the range expansion of this species and highlights the importance of anthropogenic disturbance to its spread. Location Central and Northern Europe. Methods Data on the geographic distribution of L. serriola were assembled through a literature search as well as through floristic and herbarium surveys. Maps of the spread of L. serriola in Central and Northern Europe were prepared based on herbarium data. The spread was assessed more precisely in Germany, Austria and Great Britain by pooling herbarium and literature data. We modelled the bioclimatic niche of the species using occurrence and climatic data covering the last century to generate projections of suitable habitats under the climatic conditions of five time periods. We tested whether the observed distribution of L. serriola could be explained for each time period, assuming that the climatic niche of the species was conserved across time. Results The species has spread northwards since the beginning of the 19th century. We show that climate warming in Europe increased the number of sites suitable for the species at northern latitudes. Until the late 1970s, the distribution of the species corresponded to the climatically suitable sites available. For the last two decades, however, we could not show any significant relationship between the increase in suitable sites and the distributional range change of L. serriola. However, we highlight potential areas the species could spread to in the future (Great Britain, southern Scandinavia and the Swedish coast). It is predominantly non-climatic influences of global change that have contributed to its rapid spread. Main conclusions The observation that colonizing species are not filling their climatically suitable range might imply that, potentially, other ruderal species could expand far beyond their current range. Our work highlights the importance of historical floristic and herbarium data for understanding the expansion of a species. Such historical distributional data can provide valuable information for those planning the management of contemporary environmental problems, such as species responses to environmental change.
Resumo:
Although platelet cytosolic calcium has been shown to decrease during pharmacological treatment of hypertension, there is no evidence that cytosolic calcium also falls during a nonpharmacological reduction in blood pressure. To provide such evidence, we examined prospectively the relation between platelet cytosolic calcium and ambulatory blood pressure during weight reduction in moderately overweight (body mass index [BMI] greater than 25), mildly hypertensive individuals. The experimental group (responders: BMI reduction greater than 5%) consisted of 19 patients who lost 8.5 +/- 2.9 kg (mean +/- SD, p less than 0.05) during a 10-week hypocaloric diet, whereas the control group (nonresponders: BMI reduction less than 5%) consisted of 12 patients who showed no relevant change in body weight (-2.0 +/- 1.3 kg) during the same period of time. The moderate weight loss of the responders decreased blood pressure by 14/5 mm Hg (p less than 0.05), as measured by ambulatory monitoring, which renders a placebo effect unlikely. This nonpharmacological reduction in blood pressure was accompanied by a proportional 11% decrease (p less than 0.05) in platelet cytosolic calcium and also by significant (p less than 0.05) decreases in plasma catecholamines and serum cholesterol. These findings establish the concept of a nonpharmacological reduction in free cytosolic platelet calcium in humans and add further evidence suggesting a link between intracellular calcium homeostasis and blood pressure regulation.
Resumo:
Blood pressure is lowered for a few hours after aerobic exercise, but also after resistance exercise, although for a shorter period of time. An exercise program can significantly lower resting and ambulatory BP measurements. Multiple mechanisms interact for the BP lowering effect, such as decreased total peripheral resistance, enhanced endothelial function, diminished sympathetic or rennin plasmatic activity, structural vascular modifications and baroreceptor reflex modulation. New exercises like eccentric or isometric (handgrip) contractions are promising. Resistance activities have long been considered dangerous for blood vessels because of increased arterial stiffness, but if the intensity remains moderate and aerobic exercises are integrated, then the effects are altogether beneficial.
Resumo:
OBJECTIVE: Previous research suggested that proper blood pressure (BP) management in acute stroke may need to take into account the underlying etiology. METHODS: All patients with acute ischemic stroke registered in the ASTRAL registry between 2003 and 2009 were analyzed. Unfavorable outcome was defined as modified Rankin Scale score >2. A local polynomial surface algorithm was used to assess the effect of baseline and 24- to 48-hour systolic BP (SBP) and mean arterial pressure (MAP) on outcome in patients with lacunar, atherosclerotic, and cardioembolic stroke. RESULTS: A total of 791 patients were included in the analysis. For lacunar and atherosclerotic strokes, there was no difference in the predicted probability of unfavorable outcome between patients with an admission BP of <140 mm Hg, 140-160 mm Hg, or >160 mm Hg (15.3 vs 12.1% vs 20.8%, respectively, for lacunar, p = 015; 41.0% vs 41.5% vs 45.5%, respectively, for atherosclerotic, p = 075), or between patients with BP increase vs decrease at 24-48 hours (18.7% vs 18.0%, respectively, for lacunar, p = 0.84; 43.4% vs 43.6%, respectively, for atherosclerotic, p = 0.88). For cardioembolic strokes, increase of BP at 24-48 hours was associated with higher probability of unfavorable outcome compared to BP reduction (53.4% vs 42.2%, respectively, p = 0.037). Also, the predicted probability of unfavorable outcome was significantly different between patients with an admission BP of <140 mm Hg, 140-160 mm Hg, and >160 mm Hg (34.8% vs 42.3% vs 52.4%, respectively, p < 0.01). CONCLUSIONS: This study provides evidence to support that BP management in acute stroke may have to be tailored with respect to the underlying etiopathogenetic mechanism.
Resumo:
Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.