404 resultados para Predictive Monitoring
Resumo:
Immunotherapy of melanoma is aimed to mobilize cytolytic CD8+ T cells playing a central role in protective immunity. Despite numerous clinical vaccine trials, only few patients exhibited strong antigen-specific T-cell activation, stressing the need to improve vaccine strategies. For a rational development, we propose to focus on molecularly defined vaccine components, and evaluate their immunogenicity with highly reproducible and standardized methods for ex vivo immune monitoring. Careful immunogenicity comparison of vaccine formulations in phase I/II studies allow to select optimized vaccines for subsequent clinical efficacy testing in large scale phase III trials.
Resumo:
OBJECTIVE: Routine prenatal screening for Down syndrome challenges professional non-directiveness and patient autonomy in daily clinical practices. This paper aims to describe how professionals negotiate their role when a pregnant woman asks them to become involved in the decision-making process implied by screening. METHODS: Forty-one semi-structured interviews were conducted with gynaecologists-obstetricians (n=26) and midwives (n=15) in a large Swiss city. RESULTS: Three professional profiles were constructed along a continuum that defines the relative distance or proximity towards patients' demands for professional involvement in the decision-making process. The first profile insists on enforcing patient responsibility, wherein the healthcare provider avoids any form of professional participation. A second profile defends the idea of a shared decision making between patients and professionals. The third highlights the intervening factors that justify professionals' involvement in decisions. CONCLUSIONS: These results illustrate various applications of the principle of autonomy and highlight the complexity of the doctor-patient relationship amidst medical decisions today.
Resumo:
A liquid chromatography method coupled to mass spectrometry was developed for the quantification of bupropion, its metabolite hydroxy-bupropion, moclobemide, reboxetine and trazodone in human plasma. The validation of the analytical procedure was assessed according to Société Française des Sciences et Techniques Pharmaceutiques and the latest Food and Drug Administration guidelines. The sample preparation was performed with 0.5mL of plasma extracted on a cation-exchange solid phase 96-well plate. The separation was achieved in 14min on a C18 XBridge column (2.1mm×100mm, 3.5μm) using a 50mM ammonium acetate pH 9/acetonitrile mobile phase in gradient mode. The compounds of interest were analysed in the single ion monitoring mode on a single quadrupole mass spectrometer working in positive electrospray ionisation mode. Two ions were selected per molecule to increase the number of identification points and to avoid as much as possible any false positives. Since selectivity is always a critical point for routine therapeutic drug monitoring, more than sixty common comedications for the psychiatric population were tested. For each analyte, the analytical procedure was validated to cover the common range of concentrations measured in plasma samples: 1-400ng/mL for reboxetine and bupropion, 2-2000ng/mL for hydroxy-bupropion, moclobemide, and trazodone. For all investigated compounds, reliable performance in terms of accuracy, precision, trueness, recovery, selectivity and stability was obtained. One year after its implementation in a routine process, this method demonstrated a high robustness with accurate values over the wide concentration range commonly observed among a psychiatric population.
Resumo:
IMPLICATIONS: A new combined ear sensor was tested for accuracy in 20 critically ill children. It provides noninvasive and continuous monitoring of arterial oxygen saturation, arterial carbon dioxide tension, and pulse rate. The sensor proved to be clinically accurate in the tested range.
Resumo:
Background: Age is frequently discussed as negative host factor to achieve a sustained virological response (SVR) to antiviral hepatitis C therapy. However, elderly patients often show relevant fibrosis or cirrhosis which is a known negative predictive factor, making it difficult to interpret age as an independent predictive factor. Methods: From the framework of the Swiss hepatitis C cohort (SCCS), we collected data from 545 antiviral hepatitis C therapies, including data from 67 hepatitis C patients ≥ 60 y who had been treated with PEG-interferon and ribavirin. We analyzed host factors (age, gender, fibrosis, haemoglobin, depression, earlier hepatitis C treatment), viral factors (genotype, viral load) and treatment course (early virological response, end of treatment response, SVR). Generalised estimating equations (GEE) regression modelling was used for the primary end point (SVR), with age ≥ 60 y and < 60 y as independent variable and gender, presence of cirrhosis, genotype, earlier treatment and viral load as confounders. SVR was analysed in young and elderly patients after matching for these confounders. Additionally, classification tree analysis was done in elderly patients using these confounders. Results: SVR analyzed in 545 patients was 55%. In genotype 1/4, SVR was 42.9% in 259 patients < 60 y and 26.1% in 46 patients ≥ 60 y. In genotype 2/3, SVR was 74.4% in 215 patients < 60 y and 84% in 25 patients ≥ 60 y. However, GEE model showed that age had no influence on achieving SVR (Odds ratio 0.91). Confounders influenced SVR as known from previous studies (cirrhosis, genotype 1/4, previous treatment and viral load >600'000 IE/ml as negative predictive factors). When young and elderly patients were matched (analysis in 59 elderly patients), SVR was not different in these patient groups (54.2% and 55.9%, resp.; p=0.795 in binomial test). The classification tree-derived best criterion for SVR in elderly patients was genotype, with no further criteria relevant for predicting SVR in genotype 2/3. In patients with genotype 1/4, further criteria were presence of cirrhosis and low viral load <600'000 IE/ml in non-cirrhotic patients. Conclusions: Age is not a relevant predictive factor for achieving SVR, when confounders were taken into account. In terms of effectiveness of antiviral therapy, age does not play a major role and should not be regarded as relevant negative predictive factor. Since life expectancy in Switzerland at age 60 is more than 22 y, hepatitis C therapy is reasonable in elderly patients with known relevant fibrosis or cirrhosis, because interferon-based hepatitis C therapy improves survival and reduces carcinogenesis.
Resumo:
A selective and sensitive method was developed for the simultaneous quantification of seven typical antipsychotic drugs (cis-chlorprothixene, flupentixol, haloperidol, levomepromazine, pipamperone, promazine and zuclopenthixol) in human plasma. Ultra-high performance liquid chromatography (UHPLC) was used for complete separation of the compounds in less than 4.5min on an Acquity UPLC BEH C18 column (2.1mm×50mm; 1.7μm), with a gradient elution of ammonium formate buffer pH 4.0 and acetonitrile at a flow rate of 400μl/min. Detection was performed on a tandem quadrupole mass spectrometer (MS/MS) equipped with an electrospray ionization interface. A simple protein precipitation procedure with acetonitrile was used for sample preparation. Thanks to the use of stable isotope-labeled internal standards for all analytes, internal standard-normalized matrix effects were in the range of 92-108%. The method was fully validated to cover large concentration ranges of 0.2-90ng/ml for haloperidol, 0.5-90ng/ml for flupentixol, 1-450ng/ml for levomepromazine, promazine and zuclopenthixol and 2-900ng/ml for cis-chlorprothixene and pipamperone. Trueness (89.1-114.8%), repeatability (1.8-9.9%), intermediate precision (1.9-16.3%) and accuracy profiles (<30%) were in accordance with the latest international recommendations. The method was successfully used in our laboratory for routine quantification of more than 500 patient plasma samples for therapeutic drug monitoring. To the best of our knowledge, this is the first UHPLC-MS/MS method for the quantification of the studied drugs with a sample preparation based on protein precipitation.
Resumo:
In the last issue of Blood Pressure Monitoring, (James K, Dolan E, O'Brien E. Making ambulatory blood pressure monitoring accessible in pharmacies. Blood Press Monit 2014;19:134-139) elegantly reported for the first time the characteristics of patients attending pharmacies for ambulatory blood pressure measurement (ABPM) and showed that they were similar to those undergoing ABPM through primary care practices. The authors concluded that pharmacies could be a valuable resource to perform ABPM. In the continuity of this study, we would like to emphasize the results of recent studies as well as recommenda-tions of pharmacist involvement in the management of hypertension, more specifically in a team approach.
Resumo:
This paper proposes a novel approach for the analysis of illicit tablets based on their visual characteristics. In particular, the paper concentrates on the problem of ecstasy pill seizure profiling and monitoring. The presented method extracts the visual information from pill images and builds a representation of it, i.e. it builds a pill profile based on the pill visual appearance. Different visual features are used to build different image similarity measures, which are the basis for a pill monitoring strategy based on both discriminative and clustering models. The discriminative model permits to infer whether two pills come from the same seizure, while the clustering models groups of pills that share similar visual characteristics. The resulting clustering structure allows to perform a visual identification of the relationships between different seizures. The proposed approach was evaluated using a data set of 621 Ecstasy pill pictures. The results demonstrate that this is a feasible and cost effective method for performing pill profiling and monitoring.
Resumo:
A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.
Resumo:
BACKGROUND: Infantile haemangiomas (IHs) are very common vascular tumours. Propranolol is at present the first-line treatment for problematic and complicated haemangioma. In accordance with a Swiss protocol, children are monitored for 2 days at the start of the treatment to detect possible side effects of this drug. Our study advocates a simplification of the pretreatment monitoring process. METHODS: All children with a problematic and complicated haemangioma treated with propranolol between September 2009 and September 2012 were included in the study. All patients were hospitalised under constant nurse supervision for 48 hours at the start of the treatment and subjected to cardiac and blood measurements. The dosage of propranolol was 1 mg/kg/day on the first day and 2 mg/kg/day from the second day. Demographic data, clinical features, treatment outcome and complications were analysed. RESULTS: Twenty-nine infants were included in our study. Of these, 86.2% responded immediately to the treatment. There were no severe adverse reactions. Six patients presented transient side effects such as bradycardia, hypotension after the first dose and hypoglycaemia later. No side effects occurred after the second dose. Treatment was never interrupted. CONCLUSION: Propranolol (a β-blocker) is a safe treatment for problematic IH. Side effects may occur after the first dose. A strict 48 hour monitoring in hospital is expensive and may be unnecessary as long as the contraindications for the drug are respected.
Resumo:
Long-range Terrestrial Laser Scanning (TLS) is widely used in studies on rock slope instabilities. TLS point clouds allow the creation of high-resolution digital elevation models for detailed mapping of landslide morphologies and the measurement of the orientation of main discontinuities. Multi-temporal TLS datasets enable the quantification of slope displacements and rockfall volumes. We present three case studies using TLS for the investigation and monitoring of rock slope instabilities in Norway: 1) the analysis of 3D displacement of the Oksfjellet rock slope failure (Troms, northern Norway); 2) the detection and quantification of rockfalls along the sliding surfaces and at the front of the Kvitfjellet rock slope instability (Møre og Romsdal, western Norway); 3) the analysis of discontinuities and rotational movements of an unstable block at Stampa (Sogn og Fjordane, western Norway). These case studies highlight the possibilities but also limitations of TLS in investigating and monitoring unstable rock slopes.
Resumo:
Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) without significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.