224 resultados para PROCESSING TECHNIQUE
Resumo:
We investigated respiratory responses during film clip viewing and their relation to the affective dimensions of valence and arousal. Seventy-six subjects participated in a study using a between groups design. To begin with, all participants viewed an emotionally neutral film clip. Then, they were presented with one out of four emotional film clips: a positive high-arousal, a positive low-arousal, a negative high-arousal and a negative low-arousal clip. Respiration, skin conductance level, heart rate, corrugator activity and affective judgments were measured. Expiratory time was shorter and inspiratory duty cycle, mean expiratory flow and minute ventilation were larger during the high-arousal clips compared to the low-arousal clips. The pleasantness of the stimuli had no influence on any respiratory measure. These findings confirm the importance of arousal in respiratory responding but also evidence differences in comparison to previous studies using visual and auditory stimuli. [Authors]
Resumo:
Diffusion MRI is a well established imaging modality providing a powerful way to non-invasively probe the structure of the white matter. Despite the potential of the technique, the intrinsic long scan times of these sequences have hampered their use in clinical practice. For this reason, a wide variety of methods have been proposed to shorten acquisition times. [...] We here review a recent work where we propose to further exploit the versatility of compressed sensing and convex optimization with the aim to characterize the fiber orientation distribution sparsity more optimally. We re-formulate the spherical deconvolution problem as a constrained l0 minimization.
Resumo:
INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.
Resumo:
The respiratory behavior during affective states is not completely understood. We studied breathing pattern responses to picture series in 37 participants. We also measured end-tidal pCO2 (EtCO2) to determine if ventilation is in balance with metabolic demands and spontaneous eye-blinking to investigate the link between respiration and attention. Minute ventilation (MV) and inspiratory drive increased with self-rated arousal. These relationships reflected increases in inspiratory volume rather than shortening of the time parameters. EtCO2 covaried with pleasantness but not arousal. Eye-blink rate decreased with increasing unpleasantness in line with a negativity bias in attention. This study confirms that respiratory responses to affective stimuli are organized to a certain degree along the dimensions of valence and arousal. It shows, for the first time, that during picture viewing, ventilatory increases with increasing arousal are in balance with metabolic activity and that inspiratory volume is modulated by arousal. MV emerges as the most reliable respiratory index of self-perceived arousal
Resumo:
The eye is a complex organ, which provides one of our most important senses, sight. The retina is the neuronal component of the eye and represents the connection with the central nervous system for the transmission of the information that leads to image processing. Retinitis pigmentosa (RP) is one of the most common forms of inherited retinal degeneration, in which the primary death of rods, resulting in night blindness, is always followed by the loss of cones, which leads to legal blindness. Clinical and genetic heterogeneity in retinitis pigmentosa is not only due to different mutations in different genes, but also to different effects of the same mutation in different individuals, sometimes even within the same family. My thesis work has been mainly focused on an autosomal dominant form of RP linked to mutations in the PRPF31 gene, which often shows reduced penetrance. Our study has led to the identification of the major regulator of the penetrance of PRPF31 mutations, the CNOT3 protein, and to the characterization of its mechanism of action. Following the same rationale of investigating molecular mechanisms that are responsible for clinical and genetic heterogeneity of retinitis pigmentosa, we studied a recessive form of the disease associated with mutations in the recently-identified gene FAMI61 A, where mutations in the same gene give rise to variable clinical manifestations. Our data have increased the knowledge of the relationship between genotype and phenotype in this form of the disease. Whole genome sequencing technique was also tested as a strategy for disease gene identification in unrelated patients with recessive retinitis pigmentosa and proved to be effective in identifying disease-causing variants that might have otherwise failed to be detected with other screening methods. Finally, for the first time we reported a choroidal tumor among the clinical manifestations of PTEN hamartoma tumor syndrome, a genetic disorder caused by germline mutations of the tumor suppressor gene PTEN. Our study has highlighted the heterogeneity of this choroidal tumor, showing that genetic and/or epigenetic alterations in different genes may contribute to the tumor development and growth. - L'oeil est un organe complexe, à l'origine d'un de nos sens les plus importants, la vue. La rétine est la composante neuronale de l'oeil qui constitue la connexion avec le système nerveux central pour la transmission de l'information et qui conduit à la formation des images. La rétinite pigmentaire (RP) est une des formes les plus courantes de dégénérescence rétinienne héréditaire, dans laquelle la mort primaire de bâtonnets, entraînant la cécité nocturne, est toujours suivie par la perte de cônes qui conduit à la cécité complète. L'hétérogénéité clinique et génétique dans la rétinite pigmentaire n'est pas seulement due aux différentes mutations dans des gènes différents, mais aussi à des effets différents de la même mutation chez des individus différents, parfois même dans la même famille. Mon travail de thèse s'est principalement axé sur une forme autosomique dominante de RP liée à des mutations dans le gène PRPF31, associées souvent à une pénétrance réduite, me conduisant à l'identification et à la caractérisation du mécanisme d'action du régulateur principal de la pénétrance des mutations: la protéine CNOT3. Dans la même logique d'étude des mécanismes moléculaires responsables de l'hétérogénéité clinique et génétique de la RP, nous avons étudié une forme récessive de la maladie associée à des mutations dans le gène récemment identifié FAMI61 A, dont les mutations dans le même gène donnent lieu à des manifestations cliniques différentes. Nos données ont ainsi accru la connaissance de la relation entre le génotype et le phénotype dans cette forme de maladie. La technique de séquençage du génome entier a été ensuite testée en tant que stratégie pour l'identification du gène de la maladie chez les patients atteints de RP récessive. Cette approche a montré son efficacité dans l'identification de variantes pathologiques qui n'auraient pu être détectées avec d'autres méthodes de dépistage. Enfin, pour la première fois, nous avons identifié une tumeur choroïdienne parmi les manifestations cliniques du PTEN hamartoma tumor syndrome, une maladie génétique causée par des mutations germinales du gène suppresseur de tumeur PTEN. Notre étude a mis en évidence l'hétérogénéité de cette tumeur choroïdienne, montrant que les altérations génétiques et/ou épigénétiques dans les différents gènes peuvent contribuer au développement et à la croissance tumorale.
Resumo:
Recent findings suggest that the visuo-spatial sketchpad (VSSP) may be divided into two sub-components processing dynamic or static visual information. This model may be useful to elucidate the confusion of data concerning the functioning of the VSSP in schizophrenia. The present study examined patients with schizophrenia and matched controls in a new working memory paradigm involving dynamic (the Ball Flight Task - BFT) or static (the Static Pattern Task - SPT) visual stimuli. In the BFT, the responses of the patients were apparently based on the retention of the last set of segments of the perceived trajectory, whereas control subjects relied on a more global strategy. We assume that the patients' performances are the result of a reduced capacity in chunking visual information since they relied mainly on the retention of the last set of segments. This assumption is confirmed by the poor performance of the patients in the static task (SPT), which requires a combination of stimulus components into object representations. We assume that the static/dynamic distinction may help us to understand the VSSP deficits in schizophrenia. This distinction also raises questions about the hypothesis that visuo-spatial working memory can simply be dissociated into visual and spatial sub-components.
Resumo:
A cardiac-triggered free-breathing three-dimensional balanced fast field-echo projection magnetic resonance (MR) angiographic sequence with a two-dimensional pencil-beam aortic labeling pulse was developed for the renal arteries. For data acquisition during free breathing in eight healthy adults and seven consecutive patients with renal artery disease, real-time navigator technology was implemented. This technique allows high-spatial-resolution and high-contrast renal MR angiography and visualization of renal artery stenosis without exogenous contrast agent or breath hold. Initial promising results warrant larger clinical studies.
Resumo:
Despite myriad studies, neurophysiologic mechanisms mediating illusory contour (IC) sensitivity remain controversial. Among the competing models one favors feed-forward effects within lower-tier cortices (V1/V2). Another situates IC sensitivity first within higher-tier cortices, principally lateral-occipital cortices (LOC), with later feedback effects in V1/V2. Still others postulate that LOC are sensitive to salient regions demarcated by the inducing stimuli, whereas V1/V2 effects specifically support IC sensitivity. We resolved these discordances by using misaligned line gratings, oriented either horizontally or vertically, to induce ICs. Line orientation provides an established assay of V1/V2 modulations independently of IC presence, and gratings lack salient regions. Electrical neuroimaging analyses of visual evoked potentials (VEPs) disambiguated the relative timing and localization of IC sensitivity with respect to that for grating orientation. Millisecond-by-millisecond analyses of VEPs and distributed source estimations revealed a main effect of grating orientation beginning at 65 ms post-stimulus onset within the calcarine sulcus that was followed by a main effect of IC presence beginning at 85 ms post-stimulus onset within the LOC. There was no evidence for differential processing of ICs as a function of the orientation of the grating. These results support models wherein IC sensitivity occurs first within the LOC.
Resumo:
Two-dimensional (2D)-breath-hold coronary magnetic resonance angiography (MRA) has been shown to be a fast and reliable method to depict the proximal coronary arteries. Recent developments, however, allow for free-breathing navigator gated and navigator corrected three-dimensional (3D) coronary MRA. These 3D approaches have potential for improved signal-to-noise ratio (SNR) and allow for the acquisition of adjacent thin slices without the misregistration problems known from 2D approaches. Still, a major impediment of a 3D acquisition is the increased scan time. The purpose of this study was the implementation of a free-breathing navigator gated and corrected ultra-fast 3D coronary MRA technique, which allows for scan times of less than 5 minutes. Twelve healthy adult subjects were examined in the supine position using a navigator gated and corrected ECG triggered ultra-fast 3D interleaved gradient echo planar imaging sequence (TFE-EPI). A 3D slab, consisting of 20 slices with a reconstructed slice thickness of 1.5 mm, was acquired with free-breathing. The diastolic TFE-EPI acquisition block was preceded by a T2prep pre-pulse, a diaphragmatic navigator pulse, and a fat suppression pre-pulse. With a TR of 19 ms and an effective TE of 5.4 ms, the duration of the data acquisition window duration was 38 ms. The in-plane spatial resolution was 1.0-1.3 mm*1.5-1.9 mm. In all cases, the entire left main (LM) and extensive portions of the left anterior descending (LAD) and right coronary artery (RCA) could be visualized with an average scan time for the entire 3D-volume data set of 2:57 +/- 0:51 minutes. Average contiguous vessel length visualized was 53 +/- 11 mm (range: 42 to 75 mm) for the LAD and 84 +/- 14 mm (range: 62 to 112 mm) for the RCA. Contrast-to-noise between coronary blood and myocardium was 5.0 +/- 2.3 for the LM/LAD and 8.0 +/- 2.9 for the RCA, resulting in an excellent suppression of myocardium. We present a new approach for free-breathing 3D coronary MRA, which allows for scan times superior to corresponding 2D coronary MRA approaches, and which takes advantage of the enhanced SNR of 3D acquisitions and the post-processing benefits of thin adjacent slices. The robust image quality and the short average scanning time suggest that this approach may be useful for screening the major coronary arteries or identification of anomalous coronary arteries. J. Magn. Reson. Imaging 1999;10:821-825.
Resumo:
Objectifs: Evaluer la faisabilité, les résultats préliminaires à court et long terme du vissage percutané de vissage trans -isthmique sous anesthésie locale et contrôle scannerdes lyses isthmiques de bas grades.Matériels et méthodes: Etude prospective monocentrique réalisée sur 10 patients ayant une lyse isthmique grade 1 et 2 résistant au traitement médical conventionnel. Une évaluationclinique était réalisée à un mois, 3 mois, 6 mois et un an post-opératoire par un évaluateur indépendant. L'indication est posée en concertation avec le service dechirurgie orthopédique.Résultats: Les lyses isthmiques étaient situées en L5-S1 avec 6 grades 1 et 4 grades 2. L'échelle analogique de la douleur (VAS) variait de 6 a 9 avec une moyenne de 7,8.L'indication opératoire chirurgicale était posée pour tous les patients par arthrodèse postérieure lombo -sacree. Pour chaque patient 2 vis étaient positionnées soitun total de 20 vis. Un suivi clinique était réalisé de 28 a 36 mois. L'EVA et ODI diminuaient de 7,8 +/- 1,7 à 1,9 +/- 1,2 et de 62,3 +/- 17,2 à 15,1 +/- 6,0respectivement. L'ensemble des résultats était stable dans le temps en particulier à long terme.Conclusion: La fixation précise de la lyse isthmique améliore la symptomatologie et probablement évite un glissement vertébral plus important , un suivi à plus long terme surune serie de patients plus importante devrait confirmer cette hypothèse.
Resumo:
Visualization of the vascular systems of organs or of small animals is important for an assessment of basic physiological conditions, especially in studies that involve genetically manipulated mice. For a detailed morphological analysis of the vascular tree, it is necessary to demonstrate the system in its entirety. In this study, we present a new lipophilic contrast agent, Angiofil, for performing postmortem microangiography by using microcomputed tomography. The new contrast agent was tested in 10 wild-type mice. Imaging of the vascular system revealed vessels down to the caliber of capillaries, and the digital three-dimensional data obtained from the scans allowed for virtual cutting, amplification, and scaling without destroying the sample. By use of computer software, parameters such as vessel length and caliber could be quantified and remapped by color coding onto the surface of the vascular system. The liquid Angiofil is easy to handle and highly radio-opaque. Because of its lipophilic abilities, it is retained intravascularly, hence it facilitates virtual vessel segmentation, and yields an enduring signal which is advantageous during repetitive investigations, or if samples need to be transported from the site of preparation to the place of actual analysis, respectively. These characteristics make Angiofil a promising novel contrast agent; when combined with microcomputed tomography, it has the potential to turn into a powerful method for rapid vascular phenotyping.
Resumo:
Over the past few decades, Fourier transform infrared (FTIR) spectroscopy coupled to microscopy has been recognized as an emerging and potentially powerful tool in cancer research and diagnosis. For this purpose, histological analyses performed by pathologists are mostly carried out on biopsied tissue that undergoes the formalin-fixation and paraffin-embedding (FFPE) procedure. This processing method ensures an optimal and permanent preservation of the samples, making FFPE-archived tissue an extremely valuable source for retrospective studies. Nevertheless, as highlighted by previous studies, this fixation procedure significantly changes the principal constituents of cells, resulting in important effects on their infrared (IR) spectrum. Despite the chemical and spectral influence of FFPE processing, some studies demonstrate that FTIR imaging allows precise identification of the different cell types present in biopsied tissue, indicating that the FFPE process preserves spectral differences between distinct cell types. In this study, we investigated whether this is also the case for closely related cell lines. We analyzed spectra from 8 cancerous epithelial cell lines: 4 breast cancer cell lines and 4 melanoma cell lines. For each cell line, we harvested cells at subconfluence and divided them into two sets. We first tested the "original" capability of FTIR imaging to identify these closely related cell lines on cells just dried on BaF2 slides. We then repeated the test after submitting the cells to the FFPE procedure. Our results show that the IR spectra of FFPE processed cancerous cell lines undergo small but significant changes due to the treatment. The spectral modifications were interpreted as a potential decrease in the phospholipid content and protein denaturation, in line with the scientific literature on the topic. Nevertheless, unsupervised analyses showed that spectral proximities and distances between closely related cell lines were mostly, but not entirely, conserved after FFPE processing. Finally, PLS-DA statistical analyses highlighted that closely related cell lines are still successfully identified and efficiently distinguished by FTIR spectroscopy after FFPE treatment. This last result paves the way towards identification and characterization of cellular subtypes on FFPE tissue sections by FTIR imaging, indicating that this analysis technique could become a potential useful tool in cancer research.