196 resultados para Non-invasive ventilation


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Metabolic syndrome represents a grouping of risk factors closely linked to cardiovascular diseases and diabetes. At first, nuclear medicine has no direct application in cardiology at the level of primary prevention, but positron emission tomography is a non invasive imaging technique that can assess myocardial perfusion as well as the endothelium-dependent coronary vasomotion--a surrogate marker of cardiovascular event rate--thus finding an application in studying coronary physiopathology. As the prevalence of the metabolic syndrome is still unknown in Switzerland, we will estimate it from data available in the frame of a health promotion program. Based on the deleterious effect on the endothelium already observed with two components, we will estimate the number of persons at risk in Switzerland.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Questionnaire studies indicate that high-anxious musicians may suffer from hyperventilation symptoms before and/or during performance. Reported symptoms include amongst others shortness of breath, fast or deep breathing, dizziness and thumping heart. A self-report study by Widmer, Conway, Cohen and Davies (1997) shows that up to seventy percent of the tested highly anxious musicians are hyperventilators during performance. However, no study has yet tested if these self-reported symptoms reflect actual cardiorespiratory changes just before and during performance. Disturbances in breathing patterns and hyperventilation may negatively affect the performance quality in stressful performance situations. The main goal of this study is to determine if music performance anxiety is manifest physiologically in specific correlates of cardiorespiratory activity. We studied 74 professional music students of Swiss Music Universities divided into two groups (high- and lowanxious) based on their self-reported performance anxiety (State-Trait Anxiety Inventory by Spielberger). The students were tested in three distinct situations: baseline, performance without audience, performance with audience. We measured a) breathing patterns, end-tidal carbon dioxide, which is a good non-invasive estimator for hyperventilation, and cardiac activation and b) self-perceived emotions and self-perceived physiological activation. Analyses of heart rate, respiratory rate, self-perceived palpitations, self-perceived shortness of breath and self-perceived anxiety for the 15 most and the 15 least anxious musicians show that high-anxious and low-anxious music students have a comparable physiological activation during the different measurement periods. However, highanxious music students feel significantly more anxious and perceive significantly stronger palpitations and significantly stronger shortness of breath just before and during a public performance. The results indicate that low- and high-anxious music students a) do not differ in the considered physiological responses and b) differ in the considered self-perceived physiological symptoms and the selfreported anxiety before and/or during a public performance.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: In patients with Kawasaki disease, serial evaluation of the distribution and size of coronary artery aneurysms (CAA) is necessary for risk stratification and therapeutic management. Although transthoracic echocardiography is often sufficient for this purpose initially, visualization of the coronary arteries becomes progressively more difficult as children grow. We sought to prospectively compare coronary magnetic resonance angiography (MRA) and x-ray coronary angiography findings in patients with CAA caused by Kawasaki disease. METHODS AND RESULTS: Six subjects (age 10 to 25 years) with known CAA from Kawasaki disease underwent coronary MRA using a free-breathing T2-prepared 3D bright blood segmented k-space gradient echo sequence with navigator gating and tracking. All patients underwent x-ray coronary angiography within a median of 75 days (range, 1 to 359 days) of coronary MRA. There was complete agreement between MRA and x-ray angiography in the detection of CAA (n=11), coronary artery stenoses (n=2), and coronary occlusions (n=2). Excellent agreement was found between the 2 techniques for detection of CAA maximal diameter (mean difference=0.4 +/- 0.6 mm) and length (mean difference=1.4 +/- 1.6 mm). The 2 methods showed very similar results for proximal coronary artery diameter (mean difference=0.2 +/- 0.5 mm) and CAA distance from the ostia (mean difference=0.1 +/- 1.5 mm). CONCLUSION: Free-breathing 3D coronary MRA accurately defines CAA in patients with Kawasaki disease. This technique may provide a non-invasive alternative when transthoracic echocardiography image quality is insufficient, thereby reducing the need for serial x-ray coronary angiography in this patient group.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Detection rates for adenoma and early colorectal cancer (CRC) are unsatisfactory due to low compliance towards invasive screening procedures such as colonoscopy. There is a large unmet screening need calling for an accurate, non-invasive and cost-effective test to screen for early neoplastic and pre-neoplastic lesions. Our goal is to identify effective biomarker combinations to develop a screening test aimed at detecting precancerous lesions and early CRC stages, based on a multigene assay performed on peripheral blood mononuclear cells (PBMC).Methods: A pilot study was conducted on 92 subjects. Colonoscopy revealed 21 CRC, 30 adenomas larger than 1 cm and 41 healthy controls. A panel of 103 biomarkers was selected by two approaches: a candidate gene approach based on literature review and whole transcriptome analysis of a subset of this cohort by Illumina TAG profiling. Blood samples were taken from each patient and PBMC purified. Total RNA was extracted and the 103 biomarkers were tested by multiplex RT-qPCR on the cohort. Different univariate and multivariate statistical methods were applied on the PCR data and 60 biomarkers, with significant p-value (< 0.01) for most of the methods, were selected.Results: The 60 biomarkers are involved in several different biological functions, such as cell adhesion, cell motility, cell signaling, cell proliferation, development and cancer. Two distinct molecular signatures derived from the biomarker combinations were established based on penalized logistic regression to separate patients without lesion from those with CRC or adenoma. These signatures were validated using bootstrapping method, leading to a separation of patients without lesion from those with CRC (Se 67%, Sp 93%, AUC 0.87) and from those with adenoma larger than 1cm (Se 63%, Sp 83%, AUC 0.77). In addition, the organ and disease specificity of these signatures was confirmed by means of patients with other cancer types and inflammatory bowel diseases.Conclusions: The two defined biomarker combinations effectively detect the presence of CRC and adenomas larger than 1 cm with high sensitivity and specificity. A prospective, multicentric, pivotal study is underway in order to validate these results in a larger cohort.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Non-invasive ambulatory blood pressure monitoring has proved to be very useful in evaluating hypertensive patients. However, most previous studies were performed in specialised centres. Here the results of two trials are presented in which private physicians used ambulatory BP monitoring to assess the efficacy of antihypertensive drugs. The results were very similar to those observed previously in specialised clinics. In the individual patient, the level of ambulatory recorded pressure could not be predicted based on BP readings taken at the doctor's office. Also, the BP response to antihypertensive therapy was more reproducible when evaluated by ambulatory BP monitoring than by the doctor. Thus, the use of noninvasive ambulatory BP monitoring is also very appropriate in everyday practice for the management of hypertensive patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Proton NMR spectroscopy is emerging from translational and preclinical neuroscience research as an important tool for evidence based diagnosis and therapy monitoring. It provides biomarkers that offer fingerprints of neurological disorders even in cases where a lesion is not yet observed in MR images. The collection of molecules used as cerebral biomarkers that are detectable by (1)H NMR spectroscopy define the so-called "neurochemical profile". The non-invasive quality of this technique makes it suitable not only for diagnostic purposes but also for therapy monitoring paralleling an eventual neuroprotection. The application of (1)H NMR spectroscopy in basic and translational neuroscience research is discussed here.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mise en perspective Le rein est un organe vital dont la fonction dépend en grande partie d'une perfusion tissulaire adéquate. Les techniques actuellement utilisées pour étudier la microcirculation rénale sont soit invasives soit très dispendieuses. L'échographie de contraste est une nouvelle technologie, non invasive, facile à réaliser au lit du malade et pour laquelle certaines techniques récemment présentées semblent permettre de quantifier la perfusion d'un organe. Une telle technique pourrait avoir des applications dans l'étude de l'insuffisance rénale aiguë. Buts de l'étude Notre étude vise à tester le potentiel de l'échographie de contraste pour détecter des modifications de la perfusion rénale, corticale et médullaire chez l'être humain. Plan de l'étude Nous avons étudié la microcirculation rénale par échographie de contraste chez 12 sujets sains. Les mesures ont été réalisées en baseline puis sous perfusion de doses croissantes d'angiotensine II (un puissant et spécifique vasoconstricteur rénal) et enfin après la prise orale d'un comprimé de Captopril (un puissant vasodilatateur rénal). Les valeurs obtenues par échographie de contraste ont été comparées à la perfusion globale rénale évaluée par la clairance du PAH, qui constitue le gold standard en physiologie rénale. Résultats principaux Le protocole a pu être réalisé sans complication. Les perfusions vasoactives ainsi que les différentes administrations de Sonovue ont été parfaitement tolérées. Les séquences vidéos ont été analysées par deux lecteurs et une bonne concordance a été trouvée. Nous avons trouvé une diminution statistiquement significative et dose dépendante de l'index de perfusion rénale lors de la perfusion d'angiotensine II: -45% (p<0.02) entre baseline et Ang II faible dose et -65% (p<0.01) entre baseline et Ang II à haute dose. Enfin, nous avons observé une hausse significative de cet indice après administration orale de Captopril (+35%, p>0.2). Ces changements étaient parallèles aux changements de flux plasmatique rénal mesurés par calcul de la clairance du PAH. Une corrélation moyenne mais significative (r=0.57, p=0.002) a été observée entre ces deux mesures. Conclusions et perspectives L'échographie de contraste est capable de détecter des modifications dans la microcirculation rénale induites par une perfusion d'angiotensine et ou une administration de Captopril. Il s'agit d'une technique rapide sensible et fiable qui pourrait participer à l'évaluation des patients souffrant d'insuffisance rénale aiguë. D'autres études sont nécessaires pour démontrer son utilité dans un contexte clinique.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: Diastolic dysfunction with delayed relaxation and abnormal passive elastic properties has been described in patients with severe pressure overload hypertrophy. The purpose of this study was to evaluate the time course of rotational motion of the left ventricle in patients with aortic valve stenosis using myocardial tagging. METHODS: Myocardial tagging is a non-invasive method based on magnetic resonance which makes it possible to label ('tag') specific myocardial regions. From the motion of the tag's cardiac rotation, radial displacement and translational motion can be determined. In 12 controls and 13 patients with severe aortic valve stenosis systolic and diastolic wall motion was assessed in an apical and basal short axis plane. RESULTS: The normal left ventricle performs a systolic wringing motion around the ventricular long axis with clockwise rotation at the base (-4.4+/-1.6 degrees) and counter-clockwise rotation at the apex (+6.8+/-2.5 degrees) when viewed from the apex. During early diastole an untwisting motion can be observed which precedes diastolic filling. In patients with aortic valve stenosis systolic rotation is reduced at the base (-2.4+/-2.0 degrees; P<0.01) but increased at the apex (+12.0+/-6.0 degrees; P<0.05). Diastolic untwisting is delayed and prolonged with a decrease in normalized rotation velocity (-6.9+/-1.1 s(-1)) when compared to controls (-10.7+/-2.2 s(-1); P<0.001). Maximal systolic torsion is 8.0+/-2.1 degrees in controls and 14.1+/-6.4 degrees (P<0.01) in patients with aortic valve stenosis. CONCLUSIONS: Left ventricular pressure overload hypertrophy is associated with a reduction in basal and an increase in apical rotation resulting in increased torsion of the ventricle. Diastolic untwisting is delayed and prolonged. This may explain the occurrence of diastolic dysfunction in patients with severe pressure overload hypertrophy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Assessing the total energy expenditure (TEE) and the levels of physical activity in free-living conditions with non-invasive techniques remains a challenge. The purpose of the present study was to investigate the accuracy of a new uniaxial accelerometer for assessing TEE and physical-activity-related energy expenditure (PAEE) over a 24 h period in a respiratory chamber, and to establish activity levels based on the accelerometry ranges corresponding to the operationally defined metabolic equivalent (MET) categories. In study 1, measurement of the 24 h energy expenditure of seventy-nine Japanese subjects (40 (SD 12) years old) was performed in a large respiratory chamber. During the measurements, the subjects wore a uniaxial accelerometer (Lifecorder; Suzuken Co. Ltd, Nagoya, Japan) on their belt. Two moderate walking exercises of 30 min each were performed on a horizontal treadmill. In study 2, ten male subjects walked at six different speeds and ran at three different speeds on a treadmill for 4 min, with the same accelerometer. O2 consumption was measured during the last minute of each stage and was expressed in MET. The measured TEE was 8447 (SD 1337) kJ/d. The accelerometer significantly underestimated TEE and PAEE (91.9 (SD 5.4) and 92.7 (SD 17.8) % chamber value respectively); however, there was a significant correlation between the two values (r 0.928 and 0.564 respectively; P<0.001). There was a strong correlation between the activity levels and the measured MET while walking (r(2) 0.93; P<0.001). Although TEE and PAEE were systematically underestimated during the 24 h period, the accelerometer assessed energy expenditure well during both the exercise period and the non-structured activities. Individual calibration factors may help to improve the accuracy of TEE estimation, but the average calibration factor for the group is probably sufficient for epidemiological research. This method is also important for assessing the diurnal profile of physical activity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Descriptors: music performance anxiety, respiration, hyperventilation Surveys indicate that high-anxious musicians may suffer from hyperventilation (HV) before or during performance. Reported symptoms include shortness of breath, fast/ deep breathing and thumping heart. However, no study has yet tested if these selfreported symptoms reflect actual cardiorespiratory activity. Themain goal of this study was to determine if MPA is manifested physiologically in specific correlates of cardiorespiratory activity associated with HV.We studied 74 professional music students from Swiss Music Academies. In this study, we compared the most anxious students (highanxious; n 5 20) with the least anxious students (low-anxious; n 5 23) based on their self-reported performance anxiety. We measured cardiorespiratory patterns with the Lifeshirt system, end-tidal CO2 with a capnograph (EtCO2, a good non-invasive estimator of HV), self-perceived physiological activation and affective experience in three situations on different days: baseline, performance without audience, and performance with audience. Comparing measures for the private vs. the public concert, high- compared to low-anxious students showed a significant drop in EtCO2 before the public concert and reported larger increases in anxiety, tension, palpitations and breathing difficulties. In contrast, heart rate, respiratory rate and volume did not differ significantly between groups. The results of this study support the hypothesis thatMPA may be associated with a tendency to hyperventilate and, thus, point to a potential hyperventilation problem in high-anxious music students.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Owl pellets contain a good skeletal record of the small mammals consumed, and correspond to the undigested portions of prey which are regurgitated. These pellets are easy to find at the roosting site of owls. As it has been demonstrated that amplifiable DNA can be isolated from ancient bone remains, the possibility of using owl pellets as a source of DNA for small mammal genetics studies via the polymerase chain reaction has been investigated. The main uncertainties when isolating DNA from such a material are firstly the possibility that the extracted DNA would be too degraded during the digestion in the stomach of the owl, and secondly that extensive cross-contaminations could occur among the different prey consumed. The results obtained clearly demonstrate that cross-contamination does not occur, and that mitochondrial and nuclear DNA can be amplified using skulls of small mammals found in owl pellets as a source of DNA. The relative efficiency of two methods of DNA extraction is estimated and discussed. Thus, owl pellets represent a non-invasive sampling technique which provides a valuable source of DNA for studying population genetics of small mammals.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

MicroRNAs (miRNAs) are small non-coding RNAs that regulate a variety of biological processes. Cell-free miRNAs detected in blood plasma are used as specific and sensitive markers of physiological processes and some diseases. Circulating miRNAs are highly stable in body fluids, for example plasma. Therefore, profiles of circulating miRNAs have been investigated for potential use as novel, non-invasive anti-doping biomarkers. This review describes the biological mechanisms underlying the variation of circulating miRNAs, revealing that they have great potential as a new class of biomarker for detection of doping substances. The latest developments in extraction and profiling technology, and the technical design of experiments useful for anti-doping, are also discussed. Longitudinal measurements of circulating miRNAs in the context of the athlete biological passport are proposed as an efficient strategy for the use of these new markers. The review also emphasizes potential challenges for the translation of circulating miRNAs from research into practical anti-doping applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mise au point sur le hotter implantable (Reveal®). Connaissances actuelles et implications thérapeutiques. La syncope est un problème fréquent touchant environ un tiers des adultes durant leur vie. C'est un motif de consultation habituel aux urgences et ses causes sont souvent multiples et rendent son diagnostic difficile. Malgré des investigations extensives et coûteuses la cause syncopale reste dans environ 30% des cas d'étiologie indéterminée. Les progrès récents dans le monitoring cardiaque à long terme ont permis d'inclure dans le choix des tests diagnostiques un outil très intéressant dans l'investigation de la syncope d'étiologie indéterminée (SOI). Il s'agit du moniteur ECG implantable (MEI) ou Reveal®. Il y a un peu plus de 10 ans un prototype de MEI a été implanté dans un petit collectif de patients souffrants de SOI récidivantes et a permis d'établir un diagnostic chez la plupart d'entre eux. Dès lors le système s'est modernisé avec une diminution importante de la taille et du poids permettant actuellement d'enregistrer le rythme cardiaque sur une durée de 18 à 24 mois. Le système peut stocker dans sa mémoire un tracé ECG soit à l'aide d'un activateur externe déclenché par le patient, soit de façon spontanée en présence d'un rythme cardiaque lent ou rapide. Son implantation se fait en anesthésie locale, en position sous-cutanée pectorale gauche. Les complications et les problèmes infectieux sont rares. Plusieurs études récentes se sont intéressées à l'apport diagnostique du MEI dans la prise en charge de la SOI. La plus grande porte sur un collectif de 206 patients. L'apport diagnostique des différentes études varie de 40% à 64%. Cependant la plupart de ces études ne comportaient pas de prise en charge standardisée ou avaient des critères d'inclusion précis. Nous nous sommes intéressés aux résultats de notre prise en charge de la syncope au cours de ces 6 dernières années. Une consultation spécialisée de la syncope a été mise en place en 1999. La consultation offre l'accès à tout le plateau technique propre à l'investigation de syncopes à savoir un tilt-test avec mesure continue non invasive de la pression artérielle, examens échocardiographiques et test d'effort. Si nécessaire, le bilan peut être complété par une étude électrophysiologique (EEP) et/ou une coronarographie: Tous les patients bénéficient d'une anamnèse ciblée suivi d'un examen clinique et d'un électrocardiogramme. Une échocardiographie n'est effectuée qu'en cas de suspicion de cardiopathie sous-jacente. Un holter ou R-test ne sont réalisés qu'en présence de syncopes ou palpitations fréquentes. Les investigations se poursuivent par un tilt test suivi d'un massage du sinus carotidien en position debout et couchée. Un test d'hyperventilation n'est pratiqué que chez les patients avec traits phobiques, dépressifs ou troubles de type panique. L'EEP n'est pratiquée que chez les patients dont la syncope reste d'étiologie indéterminée après investigations initiales et chez ceux souffrant d'une cardiopathie sous jacente documentée ; elle est aussi indiquée chez ceux dont le coeur est normal mais chez qui la syncope est associée à des traumatismes ou à l'origine d'un accident de voiture. Le MEI est proposé lorsque toutes les investigations initiales restent négatives, généralement chez les sujets ayant souffert de plus d'une syncope ou de complications sérieuses. Notre expérience pratique d'une consultation de la syncope ouverte au tout venant nous montre qu'une prise en charge standardisée non invasive permet d'identifier une cause syncopale chez plus de 60% des patients. Chez les patients souffrant de syncopes récidivantes ou traumatiques d'étiologie indéterminée après investigations conventionnelles, l'apport diagnostique du MEI est élevé (64%) durant un suivi moyen de 9 mois, ce qui permet d'identifier certaines causes syncopales écartées précédemment par des tests ciblés. Parmi ces dernières, retenons plus particulièrement les tachycardies nodales et crises d'épilepsie.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Arterial Spin Labeling (ASL) is a method to measure perfusion using magnetically labeled blood water as an endogenous tracer. Being fully non-invasive, this technique is attractive for longitudinal studies of cerebral blood flow in healthy and diseased individuals, or as a surrogate marker of metabolism. So far, ASL has been restricted mostly to specialist centers due to a generally low SNR of the method and potential issues with user-dependent analysis needed to obtain quantitative measurement of cerebral blood flow (CBF). Here, we evaluated a particular implementation of ASL (called Quantitative STAR labeling of Arterial Regions or QUASAR), a method providing user independent quantification of CBF in a large test-retest study across sites from around the world, dubbed "The QUASAR reproducibility study". Altogether, 28 sites located in Asia, Europe and North America participated and a total of 284 healthy volunteers were scanned. Minimal operator dependence was assured by using an automatic planning tool and its accuracy and potential usefulness in multi-center trials was evaluated as well. Accurate repositioning between sessions was achieved with the automatic planning tool showing mean displacements of 1.87+/-0.95 mm and rotations of 1.56+/-0.66 degrees . Mean gray matter CBF was 47.4+/-7.5 [ml/100 g/min] with a between-subject standard variation SD(b)=5.5 [ml/100 g/min] and a within-subject standard deviation SD(w)=4.7 [ml/100 g/min]. The corresponding repeatability was 13.0 [ml/100 g/min] and was found to be within the range of previous studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

BACKGROUND: We investigated changes in biomarkers of liver disease in HIV-HCV-coinfected individuals during successful combination antiretroviral therapy (cART) compared to changes in biomarker levels during untreated HIV infection and to HIV-monoinfected individuals. METHODS: Non-invasive biomarkers of liver disease (hyaluronic acid [HYA], aspartate aminotransferase-to-platelet ratio index [APRI], Fibrosis-4 [FIB-4] index and cytokeratin-18 [CK-18]) were correlated with liver histology in 49 HIV-HCV-coinfected patients. Changes in biomarkers over time were then assessed longitudinally in HIV-HCV-coinfected patients during successful cART (n=58), during untreated HIV-infection (n=59), and in HIV-monoinfected individuals (n=17). The median follow-up time was 3.4 years on cART. All analyses were conducted before starting HCV treatment. RESULTS: Non-invasive biomarkers of liver disease correlated significantly with the histological METAVIR stage (P<0.002 for all comparisons). The mean ±sd area under the receiver operating characteristic (AUROC) curve values for advanced fibrosis (≥F3 METAVIR) for HYA, APRI, FIB-4 and CK-18 were 0.86 ±0.05, 0.84 ±0.08, 0.80 ±0.09 and 0.81 ±0.07, respectively. HYA, APRI and CK-18 levels were higher in HIV-HCV-coinfected compared to HIV-monoinfected patients (P<0.01). In the first year on cART, APRI and FIB-4 scores decreased (-35% and -33%, respectively; P=0.1), mainly due to the reversion of HIV-induced thrombocytopaenia, whereas HYA and CK-18 levels remained unchanged. During long-term cART, there were only small changes (<5%) in median biomarker levels. Median biomarker levels changed <3% during untreated HIV-infection. Overall, 3 patients died from end-stage liver disease, and 10 from other causes. CONCLUSIONS: Biomarkers of liver disease highly correlated with fibrosis in HIV-HCV-coinfected individuals and did not change significantly during successful cART. These findings suggest a slower than expected liver disease progression in many HIV-HCV-coinfected individuals, at least during successful cART.