194 resultados para Detector direct reading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the technical feasibility of multi-detector row computed tomographic (CT) angiography in the assessment of peripheral arterial bypass grafts and to evaluate its accuracy and reliability in the detection of graft-related complications, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. MATERIALS AND METHODS: Four-channel multi-detector row CT angiography was performed in 65 consecutive patients with 85 peripheral arterial bypass grafts. Each bypass graft was divided into three segments (proximal anastomosis, course of the graft body, and distal anastomosis), resulting in 255 segments. Two readers evaluated all CT angiograms with regard to image quality and the presence of bypass graft-related abnormalities, including graft stenosis, aneurysmal changes, and arteriovenous fistulas. The results were compared with McNemar test with Bonferroni correction. CT attenuation values were recorded at five different locations from the inflow artery to the outflow artery of the bypass graft. These findings were compared with the findings at duplex ultrasonography (US) in 65 patients and the findings at conventional digital subtraction angiography (DSA) in 27. RESULTS: Image quality was rated as good or excellent in 250 (98%) and in 252 (99%) of 255 bypass segments, respectively. There was excellent agreement both between readers and between CT angiography and duplex US in the detection of graft stenosis, aneurysmal changes, and arteriovenous fistulas (kappa = 0.86-0.99). CT angiography and duplex US were compared with conventional DSA, and there was no statistically significant difference (P >.25) in sensitivity or specificity between CT angiography and duplex US for both readers for detection of hemodynamically significant bypass stenosis or occlusion, aneurysmal changes, or arteriovenous fistulas. Mean CT attenuation values ranged from 232 HU in the inflow artery to 281 HU in the outflow artery of the bypass graft. CONCLUSION: Multi-detector row CT angiography may be an accurate and reliable technique after duplex US in the assessment of peripheral arterial bypass grafts and detection of graft-related complications, including stenosis, aneurysmal changes, and arteriovenous fistulas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: More than five hundred million direct dental restorations are placed each year worldwide. In about 55% of the cases, resin composites or compomers are used, and in 45% amalgam. The longevity of posterior resin restorations is well documented. However, data on resin composites that are placed without enamel/dentin conditioning and resin composites placed with self-etching adhesive systems are missing. Material and Methods: The database SCOPUS was searched for clinical trials on posterior resin composites without restricting the search to the year of publication. The inclusion criteria were: (1) prospective clinical trial with at least 2 years of observation; (2) minimum number of restorations at last recall = 20; (3) report on dropout rate; (4) report of operative technique and materials used; (5) utilization of Ryge or modified Ryge evaluation criteria. For amalgam, only those studies were included that directly compared composite resin restorations with amalgam. For the statistical analysis, a linear mixed model was used with random effects to account for the heterogeneity between the studies. P-values under 0.05 were considered significant. Results: Of the 373 clinical trials, 59 studies met the inclusion criteria. In 70% of the studies, Class II and Class I restorations had been placed. The overall success rate of composite resin restorations was about 90% after 10 years, which was not different from that of amalgam. Restorations with compomers had a significantly lower longevity. The main reason for replacement were bulk fractures and caries adjacent to restorations. Both of these incidents were infrequent in most studies and accounted only for about 6% of all replaced restorations after 10 years. Restorations with macrofilled composites and compomer suffered significantly more loss of anatomical form than restorations with other types of material. Restorations that were placed without enamel acid etching and a dentin bonding agent showed significantly more marginal staining and detectable margins compared to those restorations placed using the enamel-etch or etch-and-rinse technique; restorations with self-etching systems were between the other groups. Restorations with compomer suffered significantly more chippings (repairable fracture) than restorations with other materials, which did not statistically differ among each other. Restorations that were placed with a rubber-dam showed significantly fewer material fractures that needed replacement, and this also had a significant effect on the overall longevity. Conclusion: Restorations with hybrid and microfilled composites that were placed with the enamel-etching technique and rubber-dam showed the best overall performance; the longevity of these restorations was similar to amalgam restorations. Compomer restorations, restorations placed with macrofilled composites, and resin restorations with no-etching or self-etching adhesives demonstrated significant shortcomings and shorter longevity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucose metabolism is difficult to image with cellular resolution in mammalian brain tissue, particularly with (18) fluorodeoxy-D-glucose (FDG) positron emission tomography (PET). To this end, we explored the potential of synchrotron-based low-energy X-ray fluorescence (LEXRF) to image the stable isotope of fluorine (F) in phosphorylated FDG (DG-6P) at 1 μm(2) spatial resolution in 3-μm-thick brain slices. The excitation-dependent fluorescence F signal at 676 eV varied linearly with FDG concentration between 0.5 and 10 mM, whereas the endogenous background F signal was undetectable in brain. To validate LEXRF mapping of fluorine, FDG was administered in vitro and in vivo, and the fluorine LEXRF signal from intracellular trapped FDG-6P over selected brain areas rich in radial glia was spectrally quantitated at 1 μm(2) resolution. The subsequent generation of spatial LEXRF maps of F reproduced the expected localization and gradients of glucose metabolism in retinal Müller glia. In addition, FDG uptake was localized to periventricular hypothalamic tanycytes, whose morphological features were imaged simultaneously by X-ray absorption. We conclude that the high specificity of photon emission from F and its spatial mapping at ≤1 μm resolution demonstrates the ability to identify glucose uptake at subcellular resolution and holds remarkable potential for imaging glucose metabolism in biological tissue. © 2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Glucocorticoids (GCs) are routinely administered systemically or injected into the eye when treating numerous ocular diseases; however, their toxicity on the retinal microvasculature has not been previously investigated. In this article, the effects of hydrocortisone (Hydro), dexamethasone, dexamethasone-phosphate and triamcinolone acetonide (TA) were evaluated in vitro on human skin microcirculation cells and, bovine endothelial retinal cells, ex-vivo, on flat mounted rat retinas. The degree of GCs induced endothelial cell death varied according to the endothelial cell type and GCs chemical properties. GCs toxicity was higher in skin microvascular endothelial cells and for hydrophobic GC formulations. The mechanism of cell death differed between GCs, Hydro and TA activated the leukocyte elastase inhibitor/L-DNase II pathways but did not activate caspases. The mechanisms of cell death observed in cell cultures were similar to those observed in rat retinal explants. Taken together these results indicate that particular attention should be paid to the potential vascular side effects when administrating GCs clinically and in particular when developing sustained-release intraocular devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dose kernel convolution (DK) methods have been proposed to speed up absorbed dose calculations in molecular radionuclide therapy. Our aim was to evaluate the impact of tissue density heterogeneities (TDH) on dosimetry when using a DK method and to propose a simple density-correction method. METHODS: This study has been conducted on 3 clinical cases: case 1, non-Hodgkin lymphoma treated with (131)I-tositumomab; case 2, a neuroendocrine tumor treatment simulated with (177)Lu-peptides; and case 3, hepatocellular carcinoma treated with (90)Y-microspheres. Absorbed dose calculations were performed using a direct Monte Carlo approach accounting for TDH (3D-RD), and a DK approach (VoxelDose, or VD). For each individual voxel, the VD absorbed dose, D(VD), calculated assuming uniform density, was corrected for density, giving D(VDd). The average 3D-RD absorbed dose values, D(3DRD), were compared with D(VD) and D(VDd), using the relative difference Δ(VD/3DRD). At the voxel level, density-binned Δ(VD/3DRD) and Δ(VDd/3DRD) were plotted against ρ and fitted with a linear regression. RESULTS: The D(VD) calculations showed a good agreement with D(3DRD). Δ(VD/3DRD) was less than 3.5%, except for the tumor of case 1 (5.9%) and the renal cortex of case 2 (5.6%). At the voxel level, the Δ(VD/3DRD) range was 0%-14% for cases 1 and 2, and -3% to 7% for case 3. All 3 cases showed a linear relationship between voxel bin-averaged Δ(VD/3DRD) and density, ρ: case 1 (Δ = -0.56ρ + 0.62, R(2) = 0.93), case 2 (Δ = -0.91ρ + 0.96, R(2) = 0.99), and case 3 (Δ = -0.69ρ + 0.72, R(2) = 0.91). The density correction improved the agreement of the DK method with the Monte Carlo approach (Δ(VDd/3DRD) < 1.1%), but with a lesser extent for the tumor of case 1 (3.1%). At the voxel level, the Δ(VDd/3DRD) range decreased for the 3 clinical cases (case 1, -1% to 4%; case 2, -0.5% to 1.5%, and -1.5% to 2%). No more linear regression existed for cases 2 and 3, contrary to case 1 (Δ = 0.41ρ - 0.38, R(2) = 0.88) although the slope in case 1 was less pronounced. CONCLUSION: This study shows a small influence of TDH in the abdominal region for 3 representative clinical cases. A simple density-correction method was proposed and improved the comparison in the absorbed dose calculations when using our voxel S value implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Professional cleaning is a basic service occupation with a wide variety of tasks carried out in all kind of different sectors and workplaces by a large workforce. One important risk for cleaning workers is the exposure to chemical substances that are present in cleaning products.Monoethanolamine was found to be often present in cleaning products such as general purpose cleaners, bathroom cleaners, floor cleaners and kitchen cleaners. Monoethanolamine can injure the skin, and exposure to monoethanolamine was associated to asthma even when the air concentrations were low. It is a strong irritant and known to be involved in sensitizing mechanisms. It is very likely that the use of cleaning products containing monoethanolamine gives rise to respiratory and dermal exposures. Therefore there is a need to further investigate the exposures to monoethanolamine for both, respiratory and dermal exposure.The determination of monoethanolamine has traditionally been difficult and analytical methods available are little adapted for occupational exposure assessments. For monoethanolamine air concentrations, a sampling and analytical method was already available and could be used. However, a method to analyses samples for skin exposure assessments as well as samples of skin permeation experiments was missing. Therefore one main objective of this master thesis was to search an already developed and described analytical method for the measurement of monoethanolamine in water solutions, and to set it up in the laboratory. Monoethanolamine was analyzed after a derivatisation reaction with o-pthtaldialdehyde. The derivated fluorescing monoethanolamine was then separated with high performance liquid chromatography and detection took place with a fluorescent detector. The method was found to be suitable for qualitative and quantitative analysis of monoethanolamine. An exposure assessment was conducted in the cleaning sector to measure the respiratory and dermal exposures to monoethanolamine during floor cleaning. Stationary air samples (n=36) were collected in 8 companies and samples for dermal exposures (n=12) were collected in two companies. Air concentrations (Mean = 0.18 mg/m3, Standard Deviation = 0.23 mg/m3, geometric Mean = 0.09 mg/m3, Geometric Standard Deviation = 3.50) detected were mostly below 1/10 of the Swiss 8h time weighted average occupational exposure limit. Factors that influenced the measured monoethanolamine air concentrations were room size, ventilation system and the concentration of monoethanolamine in the cleaning product and amount of monoethanolamine used. Measured skin exposures ranged from 0.6 to 128.4 mg/sample. Some cleaning workers that participated in the skin exposure assessment did not use gloves and had direct contact with the solutions containing the cleaning product and monoethanolamine. During the entire sampling campaign, cleaning workers mostly did not use gloves. Cleaning workers are at risk to be regularly exposed to low air concentrations of monoethanolamine. This exposure may be problematic if a worker suffers from allergic reactions (e.g. Asthma). In that case a substitution of the cleaning product may be a good prevention measure as several different cleaning products are available for similar cleaning tasks. Currently there are no occupational exposure limits to compare the skin exposures that were found. To prevent skin exposures, adaptations of the cleaning techniques and the use of gloves should be considered. The simultaneous skin and airborne exposures might accelerate adverse health effects. Overall the risks caused by exposures to monoethanolamine are considered as low to moderate when the cleaning products are used correctly. Whenever possible, skin exposures should be avoided. Further research should consider especially the dermal exposure routes, as very high exposures might occur by skin contact with cleaning products. Dermatitis but also sensitization might be caused by skin exposures. In addition, new biomedical insights are needed to better understand the risks of the dermal exposure. Therefore skin permeability experiments should be considered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Direct MR arthrography has a better diagnostic accuracy than MR imaging alone. However, contrast material is not always homogeneously distributed in the articular space. Lesions of cartilage surfaces or intra-articular soft tissues can thus be misdiagnosed. Concomitant application of axial traction during MR arthrography leads to articular distraction. This enables better distribution of contrast material in the joint and better delineation of intra-articular structures. Therefore, this technique improves detection of cartilage lesions. Moreover, the axial stress applied on articular structures may reveal lesions invisible on MR images without traction. Based on our clinical experience, we believe that this relatively unknown technique is promising and should be further developed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Medical and pharmacological direct costs of cigarette smoking cessation programmes are not covered by health insurance in several countries despite documented cost-effectiveness. Design: prospective cost identification study of a 9-week programme in Switzerland. Methods: A total of 481 smokers were followed-up for 9 weeks. Socio-demographic characteristics, number of outpatient visits, dosage and frequency of use of nicotine replacement therapy (NRT) as well as date of relapse were prospectively collected. Individual cost of care until relapse or programme end as well as cost per week of follow-up were computed. Comparisons were carried out between the groups with or without relapse at the end of the programme. Results: Of the 209 men and 272 women included, 347 patients (72%) finished the programme. Among them, 240 patients (70%) succeeded in quitting and 107 patients (30%) relapsed. As compared with the group relapsing by the end of the programme, the group succeeding in quitting was more often living in a couple (68% vs. 55%, p = 0.029). Their mean weekly costs of visits were higher (CHF 81.2 ± 6.1 vs. 78.4 ± 7.6, p = 0.001), while their mean weekly costs for NRT were similar (CHF 24.2 ± 12.6 vs. 25.4 ± 15.9, p = 0.711). Mean total costs per week were similar (CHF 105.4 ± 15.4 vs. 103.8 ± 19.4, p = 0.252). More intensive NRT at week 4 increased the probability not to relapse at the end of the programme. Conclusions: Over 9 weeks, medical and pharmacological costs of stopping smoking are low. Good medical and social support as well as adequate NRT seem to play a role in successful quitting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Summary Background  The dose-response between ultraviolet (UV) exposure patterns and skin cancer occurrence is not fully understood. Sun-protection messages often focus on acute exposure, implicitly assuming that direct UV radiation is the key contributor to the overall UV exposure. However, little is known about the relative contribution of the direct, diffuse and reflected radiation components. Objective  To investigate solar UV exposure patterns at different body sites with respect to the relative contribution of the direct, diffuse and reflected radiation. Methods  A three-dimensional numerical model was used to assess exposure doses for various body parts and exposure scenarios of a standing individual (static and dynamic postures). The model was fed with erythemally weighted ground irradiance data for the year 2009 in Payerne, Switzerland. A year-round daily exposure (08:00-17:00 h) without protection was assumed. Results  For most anatomical sites, mean daily doses were high (typically 6·2-14·6 standard erythemal doses) and exceeded the recommended exposure values. Direct exposure was important during specific periods (e.g. midday during summer), but contributed moderately to the annual dose, ranging from 15% to 24% for vertical and horizontal body parts, respectively. Diffuse irradiation explained about 80% of the cumulative annual exposure dose. Acute diffuse exposures were also observed during cloudy summer days. Conclusions  The importance of diffuse UV radiation should not be underestimated when advocating preventive measures. Messages focused on avoiding acute direct exposures may be of limited efficiency to prevent skin cancers associated with chronic exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumour localisation and tumour to normal tissue ratios of a chimeric anti-carcinoembryonic antigen (CEA) monoclonal antibody (MAb), in intact form and as an F(ab')2 fragment labelled with 125I and 131I, were compared in groups of nude mice bearing four different colon cancer xenografts, T380, Co112 or LoVo, of human origin, or a rat colon cancer transfected with human CEA cDNA, called '3G7'. For each tumour, three to four mice per time point were analysed 6, 12, 24, 48 and 96 h after MAb injection. In the different tumours, maximal localisation of intact MAb was obtained at 24 to 48 h, and of F(ab')2 fragment 12 to 24 h after injection. Among the different tumours, localisation was highest with colon cancer T380, with 64% of the injected dose per gram (% ID/g) for the intact MAb and 57% for its F(ab')2 fragment, while in the three other tumours, maximal localisation ranged from 14 to 22% ID g-1 for the intact MAb and was about 11% for the F(ab')2. Tumour to normal tissue ratios of intact MAb increased rapidly until 24 h after injection and remained stable or showed only a minor increase thereafter. In contrast, for the F(ab')2 fragment, the tumour to normal tissue ratios increased steadily up to 4 days after injection reaching markedly higher values than those obtained with intact MAb. For the four different xenografts, tumour to blood ratios of F(ab')2 were about 2, 3 and 5 to 16 times higher than those of intact antibodies at 12, 24 and 96 h after injection, respectively.