282 resultados para DOSE LIMITS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fas-deficient mice (Fas(lpr/lpr)) and humans have profoundly dysregulated T lymphocyte homeostasis, which manifests as an accumulation of CD4(+) and CD8(+) T cells as well as an unusual population of CD4(-)CD8(-)TCRαβ(+) T cells. To date, no unifying model has explained both the increased T-cell numbers and the origin of the CD4(-)CD8(-)TCRαβ(+) T cells. As Fas(lpr/lpr) mice raised in a germ-free environment still manifest lymphadenopathy, we considered that this process is primarily driven by recurrent low-avidity TCR signaling in response to self-peptide/MHC as occurs during homeostatic proliferation. In these studies, we developed two independent systems to decrease the number of self-peptide/MHC contacts. First, expression of MHC class I was reduced in OT-I TCR transgenic mice. Although OT-I Fas(lpr/lpr) mice did not develop lymphadenopathy characteristic of Fas(lpr/lpr) mice, in the absence of MHC class I, OT-I Fas(lpr/lpr) T cells accumulated as both CD8(+) and CD4(-)CD8(-) T cells. In the second system, re-expression of β(2)m limited to thymic cortical epithelial cells of Fas(lpr/lpr) β(2)m-deficient mice yielded a model in which polyclonal CD8(+) thymocytes entered a peripheral environment devoid of MHC class I. These mice accumulated significantly greater numbers of CD4(-)CD8(-)TCRαβ(+) T cells than conventional Fas(lpr/lpr) mice. Thus, Fas shapes the peripheral T-cell repertoire by regulating the survival of a subset of T cells proliferating in response to limited self-peptide/MHC contacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Exercise improves insulin resistance and is a first line for the prevention and treatment of type 2 diabetes. The extent, however, to which these responses are dose dependent is not known. The purpose of this study was to examine whether exercise dose was associated with improvements in insulin sensitivity after 4 months of exercise training in previously sedentary adults. METHODS: Fifty-five healthy volunteers participated in a 16-wk supervised endurance exercise intervention with a pre/postintervention design. Insulin sensitivity was assessed by euglycemic hyperinsulinemic clamp, peak oxygen uptake by a graded exercise test, and body composition by dual-energy x-ray absorptiometry. The exercise intervention consisted of three to five sessions per week with a minimum of three sessions supervised. A ramped exercise prescription protocol was used to achieve 75% of peak HR for 45 min per session. Exercise dose, expressed as average kilocalories expended per week, was computed as the product of exercise intensity, duration and frequency. RESULTS: Improved insulin sensitivity was significantly related to exercise dose in a graded dose-response relationship. No evidence of threshold or maximal dose-response effect was observed. Age and gender did not influence this dose-response relationship. Exercise intensity was also significantly related to improvements in insulin sensitivity, whereas frequency was not. CONCLUSIONS: This study identifies a graded dose-response relationship between exercise dose and improvements in insulin sensitivity. The implication of this observation is of importance for the adaptation of exercise prescription in clinical situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: BK virus associated nephropathy occurs in 1-10% of kidney transplant recipients and may be a cause of graft loss. This infection is difficult to manage because of the absence of specific therapy. Cidofovir, a DNA polymerase inhibitor approved for the treatment of CMV retinitis, has shown in vitro activity against BK virus and some clinical efficacy when used at low-dose in uncontrolled series. Objective: To assess the efficacy of low-dose Cidofovir in the treatment of BK virus associated nephropathy. Method: Two adult kidney transplant recipients with biopsy-proven BK nephropathy and persistent high viremia (>10,000 copies/ml) despite 3-month reduction of immunosuppressive therapy were treated by Cidofovir 0.5 mg/kg fortnightly for a total of 16 weeks (8 doses). Clinical response was assessed by following BK viremia. Results: No decrease in BK viremia was observed at any point during cidofovir therapy (see figure). Creatinine clearance remained stable during therapy and no side-effects of Cidofovir were observed. Conclusions: Low-dose Cidofovir therapy was not associated with a clearance or with a significant decrease of BK viremia. This pilot study does not confirm previous reports suggesting clinical efficacy of Cidofovir for BK virus associated nephropathy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

3D dose reconstruction is a verification of the delivered absorbed dose. Our aim was to describe and evaluate a 3D dose reconstruction method applied to phantoms in the context of narrow beams. A solid water phantom and a phantom containing a bone-equivalent material were irradiated on a 6 MV linac. The transmitted dose was measured by using one array of a 2D ion chamber detector. The dose reconstruction was obtained by an iterative algorithm. A phantom set-up error and organ interfraction motion were simulated to test the algorithm sensitivity. In all configurations convergence was obtained within three iterations. A local reconstructed dose agreement of at least 3% / 3mm with respect to the planned dose was obtained, except in a few points of the penumbra. The reconstructed primary fluences were consistent with the planned ones, which validates the whole reconstruction process. The results validate our method in a simple geometry and for narrow beams. The method is sensitive to a set-up error of a heterogeneous phantom and interfraction heterogeneous organ motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract We report here the long-term outcome of autologous stem cell transplant in peripheral T-cell lymphoma (PTCL). Forty-three consecutive patients with PTCL diagnosed between 2000 and 2011 were treated with high-dose chemotherapy (HDCT) and autologous stem cell transplant (ASCT) in our center. Diagnoses included PTCL-not otherwise specified (n = 19), anaplastic large cell lymphoma (n = 11), angioimmunoblastic T-cell lymphoma (n = 5), enteropathy-associated T-cell lymphoma (n = 5) and other rare subtypes (n = 3). Thirty-six patients with a median age of 50 years (range 22-65) were transplanted in first response and seven after relapse. After a median follow-up of 63 months, estimated overall survival at 12 years was 40%, progression-free survival at 12 years was 34% and event-free survival at 12 years was 30%. On univariate analysis, age less than 50 years and no B symptoms at diagnosis were significantly associated with prolonged overall and progression-free-survival. HDCT/ASCT for peripheral T-cell lymphoma can lead to long-term survival for patients responding to induction chemotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Efavirenz dosage adjustment in several patients with high EFV levels and presenting CNS toxicity have been successfully achieved in Switerland over the past seven years but many others have not beneficiated from dosage reduction owing to the lack of prospective studies evaluating the safety and clinical benefit of reduced dosage regimens.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Optimal valganciclovir (VGC) dosage and duration for cytomegalovirus (CMV) prophylaxis in kidney transplant recipients remains controversial. This study aimed to determine GCV blood levels and efficacy/safety observed under low-dose oral VGC in kidney transplant recipients. Secondly, to quantify the variability of GCV blood levels, and its potential clinical impact. Methods: In this prospective study, each patient at risk for CMV undergoing kidney transplantation received low-dose VGC (450 mg qd) prophylaxis for 3 months, unless GFR was below 40 mL/min, in which case the dose was adapted to 450 mg every other day. GCV levels, at trough (Ctrough) and at peak (C3h) were measured monthly and CMV viremia was assessed during and after prophylaxis using real time quantitative Polymerase Chain Reaction. Adverse effects were recorded on each GCV sampling. Patients were followed up to one year after transplantation. Results: 38 kidney recipients (19 D+/R+, 11 D+/R-, 8 D-/R+) received 3-month VGC prophylaxis. Most patients (mean GFR of 59 mL/min) received 450 mg qd but the dose was reduced to 450 mg every other day in 6 patients with mean GFR of 22 mL/min. Average GCV C3h and Ctrough (regressed at 24h or 48h) were 3.9 mg/L (CV 33%, range: 1.3-8.2) and 0.4 mg/L (CV 111%, range 0.1-3.3). Population pharmacokinetic analysis showed a fair dispersion of the parameters mainly influenced by renal function. Despite this variability, patients remained aviremic during VGC prophylaxis. Neutropenia and thrombocytopenia (grade 2-4) were reported in 4% and 3% of patients respectively. During follow-up, asymptomatic CMV viremia was reported in 25% patients. One year after transplantation, 12% patients (all D+/R-) had developed a CMV disease, which was treated with a therapeutic 6-week course of oral VGC. Conclusion: Average GCV blood levels after oral administration of low-dose VGC in kidney transplant recipients were comparable to those previously reported with oral GCV prophylaxis, efficacious and well tolerated. Thus, a 3-month course of low-dose VGC is appropriate for the renal function of most kidney transplant recipients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dans la prise en charge des maladies oncologiques, la priorité est évidemment d'assurer le contrôle de la maladie (soit le taux de récidive local et la survie globale), surtout lorsque celle-ci est diagnostiquée tôt, à un stade précoce. Cependant, lorsque la maladie est plus avancée et que ce contrôle ne peut être assuré de façon raisonnable, l'accent de la prise en charge est surtout axé sur le confort du patient. Le principe est de fournir à celui-ci, dans la mesure du possible, une qualité de vie acceptable, avec notamment des douleurs bien contrôlées.Dans le cadre de ce travail de thèse, nous nous sommes intéressés à la prise en charge palliative des lymphomes non hodgkiniens (LNH) de bas grade. La survie de ces patients peut être relativement longue (de 5 à 10 ans selon les séries), cependant, le traitement est rarement à visée curative, contrairement aux lymphomes de haut grade, dont la survie est bien moindre, mais avec une chance de guérison après un traitement intensif.Plusieurs études cliniques, à la fois prospectives et rétrospectives, ont démontré l'intérêt d'une irradiation à faible dose {2x2 Gy) lors d'atteintes tymphomateuses à l'origine de symptômes gênants (douleurs, compression par une masse, dyspnée, entre autres). Etant donné la facilité d'administration de ce traitement (seulement 2 séances de radiothérapie sont nécessaires), et sa quasi absence de survenue d'effets secondaires avec cette faible dose totale (4 Gy), nous avons voulu y apporter une contribution suisse.Notre étude rétrospective a permis d'inclure 43 patients entre le CHUV et les HUG. Les résultats que nous avons obtenus sont également dans la ligne des autres études parues, avec un excellent contrôle local, soit un soulagement rapide et durable des symptômes dans la majorité des cas.Nous espérons que ce travail de thèse, publié sous forme d'un article dans « International Journal of Radiation Oncology, Biology, Physics », permettra une prise en charge plus optimale des ces patients en leur apportant un traitement facile à administrer, efficace, sans effets secondaires dans la majorité des cas, et pouvant être répété un grand nombre de fois si nécessaire.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé La responsabilité d'un expert chargé d'apprécier la capacité érectile d'un prévenu est importante, car la peine infligée par le tribunal peut dépendre de ses conclusions. Sa tâche est en plus ardue car les procédés d'investigations de la fonction érectile ont tous des limites. Malgré toutes ces limites qui sont décrites dans cet article, l'expert peut aider à la recherche de la vérité comme les auteurs le démontrent. Summary The responsability of the expert in charge to appreciate the erectile capacity of an accused is considerable, as the sentence inflicted by the Tribunal could depend directly on his conclusions. His duty is harder as all the investigation procedures of the erectile functions have limits. Despite these limits, described in this article, the expert can help to discover the truth, as demonstrated by the authors.