217 resultados para Coordination technique
Resumo:
OBJECTIVES: To assess inter-observer variability of renal blood oxygenation level-dependent MRI (BOLD-MRI) using a new method of analysis, called the concentric objects (CO) technique, in comparison with the classical ROI (region of interest)-based technique. METHODS: MR imaging (3T) was performed before and after furosemide in 10 chronic kidney disease (CKD) patients (mean eGFR 43±24ml/min/1.73m(2)) and 10 healthy volunteers (eGFR 101±28ml/min1.73m(2)), and R2* maps were determined on four coronal slices. In the CO-technique, R2* values were based on a semi-automatic procedure that divided each kidney in six equal layers, whereas in the ROI-technique, all circles (ROIs) were placed manually in the cortex and medulla. The mean R2*values as assessed by two independent investigators were compared. RESULTS: With the CO-technique, inter-observer variability was 0.7%-1.9% across all layers in non-CKD, versus 1.6%-3.8% in CKD. With the ROI-technique, median variability for cortical and medullary R2* values was 3.6 and 6.8% in non-CKD, versus 4.7 and 12.5% in CKD; similar results were observed after furosemide. CONCLUSION: The CO-technique offers a new, investigator-independent, highly reproducible alternative to the ROI-based technique to estimate renal tissue oxygenation in CKD.
Resumo:
A single coronary artery can complicate the surgical technique of arterial switch operations, impairing early and late outcomes. We propose a new surgical approach, successfully applied in a 2.1 kg neonate, aimed at reducing the risk of early and late compression and/or distortion of the newly constructed coronary artery system.
Resumo:
OBJECTIVE: The aim of the current study was to investigate the biomechanical stability and fixation strength provided by a posterior approach reconstruction technique to realign the craniovertebral junction.¦METHODS: We tested seven human cadaver occipito-cervical spines (occiput-C4) by applying pure moments of ±1.5 Nm on a spine tester. Each specimen was tested in the following modes: 1) intact; 2) injured; 3) spacers alone at C1-C2 articulation (S); 4) spacers plus C1-C2 Posterior Instrumentation (S+PI); and 5) spacers plus C1-C2 posterior instrumentation plus midline wiring (S+PI+MLW). C1-C2 range of motion for each construct was obtained in flexion-extension, lateral bending, and axial rotation.¦RESULTS: In all the loading modes, S, S+PI, and S+PI+MLW constructs significantly reduced range of motion compared with the intact and injured condition (P < 0.05). There was no statistical difference between any of the three instrumentation constructs (P > 0.05).¦CONCLUSIONS: This study investigated the biomechanics of the posterior approach technique for realignment of the craniovertebral junction and also made comparisons with additional posterior fixations. The stand-alone spacers were stable in all three loading modes. Posterior instrumentation increased the stability as compared to stand-alone spacers. The third point of fixation, carried out by using midline wiring, increased the stability further. However, there was not much difference in the stability imparted with the midline wiring versus without. The present study highlights the biomechanics of this novel concept and reaffirms the view that distraction of the C1-C2 articular facets and direct articular joint atlantoaxial fixation would be an ideal method of management of basilar invagination.
Resumo:
Direct MR arthrography has a better diagnostic accuracy than MR imaging alone. However, contrast material is not always homogeneously distributed in the articular space. Lesions of cartilage surfaces or intra-articular soft tissues can thus be misdiagnosed. Concomitant application of axial traction during MR arthrography leads to articular distraction. This enables better distribution of contrast material in the joint and better delineation of intra-articular structures. Therefore, this technique improves detection of cartilage lesions. Moreover, the axial stress applied on articular structures may reveal lesions invisible on MR images without traction. Based on our clinical experience, we believe that this relatively unknown technique is promising and should be further developed.
Resumo:
Effective coordination is key to many situations that affect the well-being of two or more humans. Social coordination can be studied in coordination games between individuals located on networks of contacts. We study the behavior of humans in the laboratory when they play the Stag Hunt game - a game that has a risky but socially efficient equilibrium and an inefficient but safe equilibrium. We contrast behavior on a cliquish network to behavior on a random network. The cliquish network is highly clustered and resembles more closely to actual social networks than the random network. In contrast to simulations, we find that human players dynamics do not converge to the efficient outcome more often in the cliquish network than in the random network. Subjects do not use pure myopic best-reply as an individual update rule. Numerical simulations agree with laboratory results once we implement the actual individual updating rule that human subjects use in our laboratory experiments.
Resumo:
The objective of this study was to assess the efficiency of spiral CT (SCT) aortography for diagnosing acute aortic lesions in blunt thoracic trauma patients. Between October 1992 and June 1997, 487 SCT scans of the chest were performed on blunt thoracic trauma patients. To assess aortic injury, the following SCT criteria were considered: hemomediastinum, peri-aortic hematoma, irregular aspect of the aortic wall, aortic pseudodiverticulum, intimal flap and traumatic dissection. Aortic injury was diagnosed on 14 SCT examinations (2.9 %), five of the patients having had an additional digital aortography that confirmed the aortic trauma. Twelve subjects underwent surgical repair of the thoracic aorta, which in all but one case confirmed the aortic injury. Two patients died before surgery from severe brain lesions. The aortic blunt lesions were confirmed at autopsy. According to the follow-up of the other 473 patients, we are aware of no false-negative SCT examination. Our limited series shows a sensitivity of 100 % and specificity of 99.8 % of SCT aortography in the diagnosis of aortic injury. It is concluded that SCT aortagraphy is an accurate diagnostic method for the assessment of aortic injury in blunt thoracic trauma patients.
Resumo:
Nanotechnology is becoming part of our daily life in a wide range of products such as computers, bicycles, sunscreens or nanomedicines. While these applications already become reality, considerable work awaits scientists, engineers, and policy makers, who want such nanotechnological products to yield a maximum of benefit at a minimum of social, environmental, economic and (occupational) health cost. Considerable efforts for coordination and collaboration in research are needed if one wants to reach these goals in a reasonable time frame and an affordable price tag. This is recognized in Europe by the European Commission which funds not only research projects but also supports the coordination of research efforts. One of these coordination efforts is NanoImpactNet, a researcher-operated network, which started in 2008 promote scientific cross-talk across all disciplines on the health and environmental impact of nanomaterials. Stakeholders contribute to these activities, notably the definition of research and knowledge needs. Initial discussions in this domain focused on finding an agreement on common metrics, and which elements are needed for standardized approaches for hazard and exposure identification. There are many nanomaterial properties that may play a role. Hence, to gain the time needed to study this complex matter full of uncertainties, researchers and stakeholders unanimously called for simple, easy and fast risk assessment tools that can support decision making in this rapidly moving and growing domain. Today, several projects are starting or already running that will develop such assessment tools. At the same time, other projects investigate in depth which factors and material properties can lead to unwanted toxicity or exposure, what mechanisms are involved and how such responses can be predicted and modelled. A vision for the future is that once these factors, properties and mechanisms are understood, they can and will be accounted for in the development of new products and production processes following the idea of "Safety by Design". The promise of all these efforts is a future with nanomaterials where most of their risks are recognized and addressed before they even reach the market.
Resumo:
Metallic foreign bodies are rarely found in the maxillary sinus, and usually they have a dental origin.Potential complications related to foreign bodies include recurrent sinusitis, rhinolith formation, cutaneous fistula,chemical poisoning, facial neuralgic pain and even malignancies.Two main surgical approaches are currently used for the removal of foreign bodies in the maxillary sinus: the bone flap and the endoscopic sinus techniques. We are reporting two unusual cases of large high-velocity foreign bodies removed by a modified maxillary lateral antrotomy,with free bone flap repositioning and fixation with a titanium miniplate.
Resumo:
Controversy exists about the best method to achieve bone fusion in four-corner arthrodesis. Thirty-five patients who underwent this procedure by our technique were included in the study. Surgical indications were stage II-III SLAC wrist, stage II SNAC wrist and severe traumatic midcarpal joint injury. Mean follow-up was 4.6 years. Mean active flexion and extension were 34 degrees and 30 degrees respectively; grip strength recovery was 79%. Radiological consolidation was achieved in all cases. The mean DASH score was 23 and the postoperative pain improvement by visual analogue scale was statistically significant. Return to work was possible at 4 months for the average patient. Complications were a capitate fracture in one patient and the need for hardware removal in four cases. Four-corner bone wrist arthrodesis by dorsal rectangular plating achieves an acceptable preservation of range of motion with good pain relief, an excellent consolidation rate and minimal complications.