411 resultados para Colon (Anatomy)--Surgery


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND & AIMS: A fast-track program is a multimodal approach for patients undergoing colonic surgery that combines stringent regimens of perioperative care (fluid restriction, optimized analgesia, forced mobilization, and early oral feeding) to reduce perioperative morbidity, hospital stay, and cost. We investigated the impact of a fast-track protocol on postoperative morbidity in patients after open colonic surgery. METHODS: A randomized trial of patients in 4 teaching hospitals in Switzerland included 156 patients undergoing elective open colonic surgery who were assigned to either a fast-track program or standard care. The primary end point was the 30-day complication rate. Secondary end points were severity of complications, hospital stay, and compliance with the fast-track protocol. RESULTS: The fast-track protocol significantly decreased the number of complications (16 of 76 in the fast-track group vs 37 of 75 in the standard care group; P = .0014), resulting in shorter hospital stays (median, 5 days; range, 2-30 vs 9 days, respectively; range, 6-30; P < .0001). There was a trend toward less severe complications in the fast-track group. A multiple logistic regression analysis revealed fluid administration greater than the restriction limits (odds ratio, 4.198; 95% confidence interval, 1.7-10.366; P = .002) and a nonfunctioning epidural analgesia (odds ratio, 3.365; 95% confidence interval, 1.367-8.283; P = .008) as independent predictors of postoperative complications. CONCLUSIONS: The fast-track program reduces the rate of postoperative complications and length of hospital stay and should be considered as standard care. Fluid restriction and an effective epidural analgesia are the key factors that determine outcome of the fast-track program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The inflammatory prostaglandin E2 (PGE2) cytokine plays a key role in the development of colon cancer. Several studies have shown that PGE2 directly induces the growth of colon cancer cells and furthermore promotes tumor angiogenesis by increasing the production of the vascular endothelial growth factor (VEGF). The signaling intermediaries implicated in these processes have however not been fully characterized. In this report, we show that the mechanistic target of rapamycin complex 1 (mTORC1) plays an important role in PGE2-induced colon cancer cell responses. Indeed, stimulation of LS174T cells with PGE2 increased mTORC1 activity as observed by the augmentation of S6 ribosomal protein phosphorylation, a downstream effector of mTORC1. The PGE2 EP4 receptor was responsible for transducing the signal to mTORC1. Moreover, PGE2 increased colon cancer cell proliferation as well as the growth of colon cancer cell colonies grown in matrigel and blocking mTORC1 by rapamycin or ATP-competitive inhibitors of mTOR abrogated these effects. Similarly, the inhibition of mTORC1 by downregulation of its component raptor using RNA interference blocked PGE2-induced LS174T cell growth. Finally, stimulation of LS174T cells with PGE2 increased VEGF production which was also prevented by mTORC1 inhibition. Taken together, these results show that mTORC1 is an important signaling intermediary in PGE2 mediated colon cancer cell growth and VEGF production. They further support a role for mTORC1 in inflammation induced tumor growth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an ever-growing trend towards less-invasive procedures in all fields of medicine. We designed an animal study to prove the concept that trans-apical aortic valve replacement from an incision within the umbilicus through a single channel for instruments is feasible, which would be a major leap towards no-scar cardiac surgery. In three adult pigs, after creating a single 3-cm incision at a place where the human umbilicus would be, we introduced a 30F sheath through a tunnel created by an endoscopic vein-harvesting device up to the cardiac apex, through it and up to the left ventricle simulating the approach for trans-apical aortic valve replacement. We used a standard Amplatz nitinol occluder to seal the defect in ventricle wall later. The animals were followed up for 1h. Blood loss was minimal, and no tamponade occurred in any of the animals. In addition, we performed a test with water column static pressure to evaluate the impact of preclotting on the sealing properties of the occluders: 1 min flow-through was 2860+/-176 ml for the standard occluders and 348+/-56 ml for preclotted occluders (p<0.001).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Fish oil (FO) may attenuate the inflammatory response after major surgery such as abdominal aortic aneurysm (AAA) surgery. We aimed at evaluating the clinical impact and safety aspects of a FO containing parenteral nutrition (PN) after AAA surgery. METHODS: Intervention consisted in 4 days of either standard (STD: Lipofundin medium-chain triglyceride (MCT): long-chain triglyceride (LCT)50%-MCT50%) or FO containing PN (FO: Lipoplus: LCT40%-MCT50%-FO10%). Energy target were set at 1.3 times the preoperative resting energy expenditure by indirect calorimetry. Blood sampling on days 0, 2, 3 and 4. Glucose turnover by the (2)H(2)-glucose method. Muscle microdialysis. Clinical data: maximal daily T degrees, intensive care unit (ICU) and hospital stay. RESULTS: Both solutions were clinically well tolerated, without any differences in laboratory safety parameters, inflammatory, metabolic data, or in organ failures. Plasma tocopherol increased similarly; with FO, docosahexaenoic and eicosapentaenoic acid increased significantly by day 4 versus baseline or STD. To increased postoperatively, with a trend to lower values in FO group (P=0.09). After FO, a trend toward shorter ICU stay (1.6+/-0.4 versus 2.3+/-0.4), and hospital stay (9.9+/-2.4 versus 11.3+/-2.7 days: P=0.19) was observed. CONCLUSIONS: Both lipid emulsions were well tolerated. FO-PN enhanced the plasma n-3 polyunsaturated fatty acid content, and was associated with trends to lower body temperature and shorter length of stay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: IOL centration and stability after cataract surgery is of high interest for cataract surgeons and IOL-producing companies. We present a new imaging software to evaluate the centration of the rhexis and the centration of the IOL after cataract surgery.Methods: We developed, in collaboration with the Biomedical Imaging Group (BIG), EPFL, Lausanne, a new working tool in order to assess precisely outcomes after IOL-implantation, such as ideal capsulorhexis and IOL-centration. The software is a plug-in of ImageJ, a general-purpose image processing and image-analysis package. The specifications of this software are: evaluation of the rhexis-centration and evaluation the position of the IOL in the posterior chamber. The end points are to analyze the quality of the centration of a rhexis after cataract surgery, the deformation of the rhexis with capsular bag retraction and the centration of the IOL after implantation.Results: This software delivers tools to interactively measure the distances between limbus, IOL and capsulorhexis and its changes over time. The user is invited to adjust nodes of three radial curves for the limbus, rhexis and the optic of the IOL. The radial distances of the curves are computed to evaluate the IOL implantation. The user is also able to define patterns for ideal capsulorhexis and optimal IOL-centration. We are going to present examples of calculations after cataract surgery.Conclusions: Evaluation of the centration of the rhexis and of the IOL after cataract surgery is an important end point for optimal IOL implantation after cataract surgery. Especially multifocal or accommodative lenses need a precise position in the bag with a good stability over time. This software is able to evaluate these parameters just after the surgery but also its changes over time. The results of these evaluations can lead to an optimizing of surgical procedures and materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A bioresorbable membrane made of sodium hyaluronate and carboxymethycellulose, has been reported to prevent peritoneal adhesion. This study was designed to test its efficiency in the prevention of pericardial adhesions. Two groups of six pigs (mean weight 72 +/- 8 kg) were chosen for the experiment. The heart was exposed through a left thoracotomy and a wide patch of pericardium was excised. In the test group (n = 6), the left ventricular area without pericardium was divided into two areas: area A where six stitches of Prolene were performed, and area B which was left intact. The membrane was applied on the both areas as well as on the adjacent area covered with pericardium (area C). In the control group (n = 6), the same protocol was performed except for the membrane application. The animals were sacrificed one month later. The adhesion status as well as the visibility of the coronary anatomy was assessed according to severity scores ranging from 0 to 3 for the adhesions and from 0 to 2 for the visibility. The difference between groups was considered significant when p < 0.05. The adhesion score of the area A was 1.7 +/- 0.5 in the test group versus 2.5 +/- 0.5 in the control group (p = 0.02) and the visibility score was 1.3 +/- 0.8 and 2 +/- 0 respectively (p = 0.07). In the area B, the adhesion score was 1 +/- 0 in the test group versus 2 +/- 0.6 in the control group (p = 0.03) and the visibility score was 0.7 +/- 0.5 and 2 +/- 0 respectively (p = 0.001). Lastly, in the area C, the adhesion score was 1 +/- 0 in both groups (n.s.) and the visibility score was 0.7 +/- 0.4 in the test group versus 0.5 +/- 0.5 in the control group (n.s.). In this animal model, the role of the bioresorbable membrane in the prevention of pericardial adhesions is limited to the areas without pericardial cover and without foreign material. The presence of foreign material neutralizes its effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wear of polyethylene is associated with aseptic loosening of orthopaedic implants and has been observed in hip and knee prostheses and anatomical implants for the shoulder. The reversed shoulder prostheses have not been assessed as yet. We investigated the volumetric polyethylene wear of the reversed and anatomical Aequalis shoulder prostheses using a mathematical musculoskeletal model. Movement and joint stability were achieved by EMG-controlled activation of the muscles. A non-constant wear factor was considered. Simulated activities of daily living were estimated from in vivo recorded data. After one year of use, the volumetric wear was 8.4 mm(3) for the anatomical prosthesis, but 44.6 mm(3) for the reversed version. For the anatomical prosthesis the predictions for contact pressure and wear were consistent with biomechanical and clinical data. The abrasive wear of the polyethylene in reversed prostheses should not be underestimated, and further analysis, both experimental and clinical, is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cataract surgery is the most frequent surgery performed in the world. Modernization of cataract surgery is a continuous process and recent technological progress have enlarged the spectrum of treatable refractive errors, improved safety of surgery, speed of visual recovery and reduction of complications rate. Thus, during the last years, refractive intraocular lenses such as toric and multifocal IOLS have been introduced in practice, as well as torsional phacoemulsification and corneal microincision. For endophthalmitis prophylaxis, modern management includes intracameral injection of antibiotics. The future of cataract surgery is probably to replace phacoemulsification surgery by laser surgery, which is safer and more reproducible.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To comprehensively assess pre-, intra-, and postoperative delirium risk factors as potential targets for intervention. BACKGROUND: Delirium after cardiac surgery is associated with longer intensive care unit (ICU) stay, and poorer functional and cognitive outcomes. Reports on delirium risk factors so far did not cover the full range of patients' presurgical conditions, intraoperative factors, and postoperative course. METHODS: After written informed consent, 221 consecutive patients ≥ 50 years scheduled for cardiac surgery were assessed for preoperative cognitive performance, and functional and physical status. Clinical and biochemical data were systematically recorded perioperatively. RESULTS: Of the 215 patients remaining for analysis, 31% developed delirium in the intensive care unit. Using logistic regression models, older age [73.3 (71.2-75.4) vs 68.5 (67.0-70.0); P = 0.016], higher Charlson's comorbidity index [3.0 (1.5-4.0) vs 2.0 (1.0-3.0) points; P = 0.009], lower Mini-Mental State Examination (MMSE) score (MMSE, [27 (23-29) vs 28 (27-30) points; P = 0.021], length of cardiopulmonary bypass (CPB) [CPB; 133 (112-163) vs 119 (99-143) min; P = 0.004], and systemic inflammatory response syndrome in the intensive care unit [25 (36.2%) vs 13 (8.9%); P = 0.001] were independently associated with delirium. Combining age, MMSE score, Charlson's comorbidity index, and length of CPB in a regression equation allowed for a prediction of postoperative delirium with a sensitivity of 71.19% and a specificity of 76.26% (receiver operating analysis, area under the curve: 0.791; 95% confidence interval: 0.727-0.845). CONCLUSIONS: Further research will evaluate if modification of these risk factors prevents delirium and improves outcomes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fat embolism syndrome is a rare complication that develops after extended soft tissue disruption by liposuction, in particular if combined with time consuming, multiple procedures. Early signs are non-specific and often not considered, so that diagnosis and correct management may be delayed. We report a case in which liposuction combined with other aesthetic surgical procedures caused a fat embolism syndrome in a 46-year-old woman, which was followed by multiple organ failure and the development of sepsis with perimammary abscesses. Extended liposuction of the abdomen and thighs, bilateral augmentation mammaplasty, and stripping of both greater saphenous veins were combined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Whereas gastrointestinal symptoms such as vomiting, diarrhea and abdominal pain are common in children suffering from the so-called post-diarrheal form (D+) of hemolytic uremic syndrome (HUS), more serious gastrointestinal complications are rare. We tried to define factors predictive of the severity of gastrointestinal complications post D+ HUS. METHODS: We reviewed the files of all children admitted to our hospital for D+ HUS between 1988 and 2000. We retained those cases with gastrointestinal complications and analyzed the consequences of these complications on the evolution of the children's conditions. RESULTS: Sixty-five children with D+ HUS were admitted to our hospital during this period. Sixteen children developed gastrointestinal complications involving one or more digestive organs: necrosis of the colon or ileum, hemorrhagic colitis, pancreatitis, transient diabetes, hepatic cytolysis and cholestasis, peritonitis and prolapse of the rectum. One child died. CONCLUSION: Gastrointestinal complications of D+ HUS are rare, but they can be lethal, and early surgery may sometimes prove necessary. However, we were not able to demonstrate a correlation between the severity of the gastrointestinal manifestations and the clinical or biological signs accompanying D+ HUS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We aimed to analyze the changes in isokinetic internal (IR) and external (ER) rotator muscles fatigue (a) in patients with non-operated recurrent anterior instability, and (b) before and after shoulder surgical stabilization with the Bristow-Latarjet procedure. Thirty-seven patients with non-operated unilateral recurrent anterior post-traumatic instability (NG) were compared with 12 healthy subjects [control group (CG)]. Twenty patients with operated recurrent anterior instability group (OG) underwent isokinetic evaluation before and 3, 6, and 21 months after Bristow-Latarjet surgery. IR and ER muscles strength was evaluated with Con-Trex® dynamometer, with subjects seated and at a 45° shoulder abduction angle in scapular plane. IR and ER muscle fatigue was determined after 10 concentric repetitions at 180° · s(-1) through the fatigue index, the percent decrease in performance (DP), and the slope of peak torque decrease. There were no differences in rotator muscles fatigue between NG and CG. In OG, 3 months post-surgery, IR DP of operated shoulder was significantly (P < 0.001) higher than presurgery and 6 and 21 months post-surgery. Rotator muscles fatigability was not associated with recurrent anterior instability. After surgical stabilization, there was a significantly higher IR fatigability in the operated shoulder 3 months post-surgery, followed by recovery evidenced 6 months post-surgery and long-term maintenance over 21 months.