187 resultados para Aortic rupture
Resumo:
OBJECTIVES Guidelines proposed bioprosthesis implantation for aortic valve disease if the patients were at least 65 years old at the time of surgery, with a trend towards even younger patients in recent years. Considering the adverse effects of lifetime anticoagulation, new biological valves (less prone to degeneration) and new technologies may lead patients and surgeons to different choices. Therefore, it is interesting to analyse the results of aortic bioprosthetic valve replacement in patients aged <65 years at the time of surgery. METHODS From January 2000 to December 2010, 84 patients aged <65 years at the time of surgery had undergone an aortic bio-prosthetic valve replacement. A mid-term follow-up [(FU) mean FU time: 54.4 ± 39.2 months] was done in August 2011 in all patients (FU completeness: 100%). Results were compared with patients who had a mechanical prosthetic aortic valve replacement during the same period. RESULTS The reoperation rate for structural valve degeneration (SVD) of bioprostheses was 6% and occurred exclusively among patients <56 years. Contraindications for anticoagulation determined the choice of a bioprosthesis among 83% of these patients. The personal preference to avoid anticoagulation was the leading cause in 68% of the older patients (56-65 years). Neurological complications occurred more frequently in the mechanical control group. CONCLUSIONS Reoperations for SVD after bioprosthesis implantation occurred exclusively among younger patients (<56 years), not suitable for systemic anticoagulation. Previous studies, together with our experience, are in favour of an age limit between 56 and 60 years, taking into consideration alternative transcatheter approaches to SVD treatment.
Resumo:
BACKGROUND/OBJECTIVES: The most recent ACC/AHA guidelines recommend high-intensity statin therapy in ischemic stroke patients of presumably atherosclerotic origin. On the contrary, there is no specific recommendation for the use of statin in patients with non-atherosclerotic stroke, e.g. strokes related to atrial fibrillation (AF). We investigated whether statin treatment in patients with AF-related stroke is associated with improved survival and reduced risk for stroke recurrence and future cardiovascular events. METHODS: All consecutive patients registered in the Athens Stroke Registry with AF-related stroke and no history of coronary artery disease nor clinically manifest peripheral artery disease were included in the analysis and categorized in two groups depending on whether statin was prescribed at discharge. The primary outcome was overall mortality; the secondary outcomes were stroke recurrence and a composite cardiovascular endpoint comprising of recurrent stroke, myocardial infarction, aortic aneurysm rupture or sudden cardiac death during the 5-year follow-up. RESULTS: Among 1602 stroke patients, 404 (25.2%) with AF-related stroke were included in the analysis, of whom 102 (25.2%) were discharged on statin. On multivariate Cox-proportional-hazards model, statin treatment was independently associated with a lower mortality (hazard-ratio (HR): 0.49, 95%CI:0.26-0.92) and lower risk for the composite cardiovascular endpoint during the median 22months follow-up (HR: 0.44, 95%CI:0.22-0.88), but not with stroke recurrence (HR: 0.47, 95%CI:0.22-1.01, p: 0.053). CONCLUSIONS: In this long-term registry of patients with AF-related stroke, statin treatment was associated with improved survival and reduced risk for future cardiovascular events.
Resumo:
Cardiovascular complications of cocaine abuse include myocardial ischemia and infarction, dysrhythmias, cardiomyopathies and aortic dissection. The case in point pertains to a 26-year-old, Caucasian male, substance abuser who suffered a thoracic aortic dissection following the use of crack cocaine. The autopsy and histological findings showed a connective tissue abnormality including a focal microcystic medial necrosis and a fragmentation of the elastic fibers in the arterial walls. Blood concentrations of cocaine and benzoylecgonine, taken individually, were considered to be within a potentially toxic range. Blood concentrations of methadone also indicated use of this drug at the same time. The small amounts of morphine found in the blood and urine were compatible with heroine or morphine use more than 24 h before death.
Resumo:
OBJECTIVE: The cause precipitating intracranial aneurysm rupture remains unknown in many cases. It has been observed that aneurysm ruptures are clustered in time, but the trigger mechanism remains obscure. Because solar activity has been associated with cardiovascular mortality and morbidity, we decided to study its association to aneurysm rupture in the Swiss population. METHODS: Patient data were extracted from the Swiss SOS database, at time of analysis covering 918 consecutive patients with angiography-proven aneurysmal subarachnoid hemorrhage treated at 7 Swiss neurovascular centers between January 1, 2009, and December 31, 2011. The daily rupture frequency (RF) was correlated to the absolute amount and the change in various parameters of interest representing continuous measurements of solar activity (radioflux [F10.7 index], solar proton flux, solar flare occurrence, planetary K-index/planetary A-index, Space Environment Services Center [SESC] sunspot number and sunspot area) using Poisson regression analysis. RESULTS: During the period of interest, there were 517 days without recorded aneurysm rupture. There were 398, 139, 27, 12, 1, and 1 days with 1, 2, 3, 4, 5, and 6 ruptures per day. Poisson regression analysis demonstrated a significant correlation of F10.7 index and RF (incidence rate ratio [IRR] = 1.006303; standard error (SE) 0.0013201; 95% confidence interval (CI) 1.003719-1.008894; P < 0.001), according to which every 1-unit increase of the F10.7 index increased the count for an aneurysm to rupture by 0.63%. A likewise statistically significant relationship of both the SESC sunspot number (IRR 1.003413; SE 0.0007913; 95% CI 1.001864-1.004965; P < 0.001) and the sunspot area (IRR 1.000419; SE 0.0000866; 95% CI 1.000249-1.000589; P < 0.001) emerged. All other variables analyzed showed no significant correlation with RF. CONCLUSIONS: We found greater radioflux, SESC sunspot number, and sunspot area to be associated with an increased count of aneurysm rupture. The clinical meaningfulness of this statistical association must be interpreted carefully and future studies are warranted to rule out a type-1 error.
Resumo:
Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.