181 resultados para ventricular assist device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

An implantable cardiac defibrillator (ICD) is a cardiac implantable electronic device that is capable of identifying and treating ventricular arrhythmias. Consideration about the type of ICD to select for a given patient include whether the patient has bradycardia requiring pacing support, has associated atrial tachyarrhythmias, or would benefit from cardiac resynchronization therapy. The ICD functions by continuously monitoring the patient's cardiac rate and delivering therapies (anti-tachycardia pacing, shocks) when the rate exceeds the programmed rate "cutoff". Secondary prevention trials have demonstrated that ICDs reduce the incidence of arrhythmic death and total mortality in patients presenting with a cardiac arrest. ICDs are also indicated for primary prevention of sudden cardiac death in specific high-risk subgroups of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In cases of transjugular liver biopsies, the venous angle formed between the chosen hepatic vein and the vena cava main axis in a frontal plane can be large, leading to technical difficulties. In a prospective study including 139 consecutive patients who underwent transjugular liver biopsy using the Quick-Core biopsy set, the mean venous angle was equal to 49.6 degrees. For 21.1% of the patients, two attempts at hepatic venous catheterization failed because the venous angle was too large, with a mean of 69.7 degrees. In all of these patients, manual reshaping of the distal curvature of the stiffening metallic cannula, by forming a new mean angle equal to 48 degrees , allowed successful completion of the procedure in less than 10 min.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Recent data suggest that beta-blockers can be beneficial in subgroups of patients with chronic heart failure (CHF). For metoprolol and carvedilol, an increase in ejection fraction has been shown and favorable effects on the myocardial remodeling process have been reported in some studies. We examined the effects of bisoprolol fumarate on exercise capacity and left ventricular volume with magnetic resonance imaging (MRI) and applied a novel high-resolution MRI tagging technique to determine myocardial rotation and relaxation velocity. METHODS: Twenty-eight patients (mean age, 57 +/- 11 years; mean ejection fraction, 26 +/- 6%) were randomized to bisoprolol fumarate (n = 13) or to placebo therapy (n = 15). The dosage of the drugs was titrated to match that of the the Cardiac Insufficiency Bisoprolol Study protocol. Hemodynamic and gas exchange responses to exercise, MRI measurements of left ventricular end-systolic and end-diastolic volumes and ejection fraction, and left ventricular rotation and relaxation velocities were measured before the administration of the drug and 6 and 12 months later. RESULTS: After 1 year, heart rate was reduced in the bisoprolol fumarate group both at rest (81 +/- 12 before therapy versus 61 +/- 11 after therapy; P <.01) and peak exercise (144 +/- 20 before therapy versus 127 +/- 17 after therapy; P <.01), which indicated a reduction in sympathetic drive. No differences were observed in heart rate responses in the placebo group. No differences were observed within or between groups in peak oxygen uptake, although work rate achieved was higher (117.9 +/- 36 watts versus 146.1 +/- 33 watts; P <.05) and exercise time tended to be higher (9.1 +/- 1.7 minutes versus 11.4 +/- 2.8 minutes; P =.06) in the bisoprolol fumarate group. A trend for a reduction in left ventricular end-diastolic volume (-54 mL) and left ventricular end-systolic volume (-62 mL) in the bisoprolol fumarate group occurred after 1 year. Ejection fraction was higher in the bisoprolol fumarate group (25.0 +/- 7 versus 36.2 +/- 9%; P <.05), and the placebo group remained unchanged. Most changes in volume and ejection fraction occurred during the latter 6 months of treatment. With myocardial tagging, insignificant reductions in left ventricular rotation velocity were observed in both groups, whereas relaxation velocity was reduced only after bisoprolol fumarate therapy (by 39%; P <.05). CONCLUSION: One year of bisoprolol fumarate therapy resulted in an improvement in exercise capacity, showed trends for reductions in end-diastolic and end-systolic volumes, increased ejection fraction, and significantly reduced relaxation velocity. Although these results generally confirm the beneficial effects of beta-blockade in patients with chronic heart failure, they show differential effects on systolic and diastolic function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Osteoporosis (OP) is a systemic skeletal disease characterized by a low bone mineral density (BMD) and a micro-architectural (MA) deterioration. Clinical risk factors (CRF) are often used as a MA approximation. MA is yet evaluable in daily practice by the trabecular bone score (TBS) measure. TBS is very simple to obtain, by reanalyzing a lumbar DXA-scan. TBS has proven to have diagnosis and prognosis values, partially independent of CRF and BMD. The aim of the OsteoLaus cohort is to combine in daily practice the CRF and the information given by DXA (BMD, TBS and vertebral fracture assessment (VFA)) to better identify women at high fracture risk. The OsteoLaus cohort (1400 women 50 to 80 years living in Lausanne, Switzerland) started in 2010. This study is derived from the cohort COLAUS who started in Lausanne in 2003. The main goal of COLAUS is to obtain information on the epidemiology and genetic determinants of cardiovascular risk in 6700 men and women. CRF for OP, bone ultrasound of the heel, lumbar spine and hip BMD, VFA by DXA and MA evaluation by TBS are recorded in OsteoLaus. Preliminary results are reported. We included 631 women: mean age 67.4 ± 6.7 years, BMI 26.1 ± 4.6, mean lumbar spine BMD 0.943 ± 0.168 (T-score − 1.4 SD), and TBS 1.271 ± 0.103. As expected, correlation between BMD and site matched TBS is low (r2 = 0.16). Prevalence of VFx grade 2/3, major OP Fx and all OP Fx is 8.4%, 17.0% and 26.0% respectively. Age- and BMI-adjusted ORs (per SD decrease) are 1.8 (1.2-2.5), 1.6 (1.2-2.1), and 1.3 (1.1-1.6) for BMD for the different categories of fractures and 2.0 (1.4-3.0), 1.9 (1.4-2.5), and 1.4 (1.1-1.7) for TBS respectively. Only 32 to 37% of women with OP Fx have a BMD < − 2.5 SD or a TBS < 1.200. If we combine a BMD < − 2.5 SD or a TBS < 1.200, 54 to 60% of women with an osteoporotic Fx are identified. As in the already published studies, these preliminary results confirm the partial independence between BMD and TBS. More importantly, a combination of TBS subsequent to BMD increases significantly the identification of women with prevalent OP Fx which would have been misclassified by BMD alone. For the first time we are able to have complementary information about fracture (VFA), density (BMD), micro- and macro architecture (TBS and HAS) from a simple, low ionizing radiation and cheap device: DXA. Such complementary information is very useful for the patient in the daily practice and moreover will likely have an impact on cost effectiveness analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zebrafish and Xenopus have become popular model organisms for studying vertebrate development of many organ systems, including the heart. However, it is not clear whether the single ventricular hearts of these species possess any equivalent of the specialized ventricular conduction system found in higher vertebrates. Isolated hearts of adult zebrafish (Danio rerio) and African toads (Xenopus laevis) were stained with voltage-sensitive dye and optically mapped in spontaneous and paced rhythms followed by histological examination focusing on myocardial continuity between the atrium and the ventricle. Spread of the excitation wave through the atria was uniform with average activation times of 20 +/- 2 and 50 +/- 2 ms for zebrafish and Xenopus toads, respectively. After a delay of 47 +/- 8 and 414 +/- 16 ms, the ventricle became activated first in the apical region. Ectopic ventricular activation was propagated significantly more slowly (total ventricular activation times: 24 +/- 3 vs. 14 +/- 2 ms in zebrafish and 74 +/- 14 vs. 35 +/- 9 ms in Xenopus). Although we did not observe any histologically defined tracts of specialized conduction cells within the ventricle, there were trabecular bands with prominent polysialic acid-neural cell adhesion molecule staining forming direct myocardial continuity between the atrioventricular canal and the apex of the ventricle; i.e., the site of the epicardial breakthrough. We thus conclude that these hearts are able to achieve the apex-to-base ventricular activation pattern observed in higher vertebrates in the apparent absence of differentiated conduction fascicles, suggesting that the ventricular trabeculae serve as a functional equivalent of the His-Purkinje system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : La prise en charge des patients critiques nécessite dans la majorité des situations l'obtention rapide d'un accès vasculaire, afin d'administrer des médicaments, des solutés de remplissage, ou des produits sanguins. La mise en place d'un accès vasculaire peut s'avérer difficile chez ces patients. En cas d'échec de pose d'une voie veineuse périphérique, des abords vasculaires alternatifs existent. Il s'agit essentiellement de la pose d'une voie veineuse centrale, la réalisation d'une dénudation veineuse, ou la pose d'une voie intra-osseuse. Depuis le développement de dispositifs d'insertion « semi-automatique » à la fin des années 90, la voie intra-osseuse, traditionnellement réservée aux cas pédiatriques, est de plus en plus fréquemment utilisée chez les patients adultes. Le Service des Urgences du CHUV a introduit en 2009 les dispositifs d'insertion d'aiguilles intra-osseuses de type EZ-IO® (perceuse électrique), en salle de réanimation des urgences vitales (déchoquage), ainsi qu'au sein du secteur préhospitalier pour les interventions du SMUR de Lausanne et de l'hélicoptère REGA de la base de Lausanne. Par cette étude, nous voulions mettre en évidence les aspects épidémiologiques des patients ayant dû être perfusés par cet abord dans un contexte préhospitalier, ainsi que les circonstances cliniques ayant justifié un tel usage, le taux de succès, les éventuelles complications, les médicaments perfusés et la mortalité des patients ayant bénéficié de ce dispositif. Méthode: Chaque patient ayant bénéficié de la mise en place d'une voie intra-osseuse par EZ-IO® du 1er janvier 2009 au 31 décembre 2011 a été inclus. Les données récoltées étaient l'âge, le sexe, l'indication à la mise en place de l'intra-osseuse, la localisation, le taux de succès, les médicaments et fluides administrés, les complications, la mortalité à 48 heures et à la sortie de l'hôpital. Tous les articles mentionnant l'utilisation de ΙΈΖ-ΙΟ® dans des situations cliniques ont également été analysés par une revue de littérature structurée exhaustive, afin de comparer nos résultats avec les données de la littérature. Résultats : Cinquante-huit patients, représentant 60 intra-osseuses EZ-IO®, ont été inclus. Leur âge moyen (47 ans), le taux de succès (90%), les indications, la localisation de l'aiguille (98% au niveau du tibia proximal) et le taux de complications (0%) correspondent aux valeurs trouvées dans la littérature. Le taux de survie de nos patients est de 38% à 48 heures et de 29% à la sortie de l'hôpital. De nombreux médicaments ou solutés de perfusion ont été administrés; l'adrénaline restant le médicament le plus fréquemment administré par cette voie. Dans 7 cas, les patients ont bénéficié d'une induction d'anesthésie par voie intra-osseuse. La revue de littérature a permis de compiler 30 études distinctes, représentant un total de 1603 accès vasculaires de type EZ-IO®. Conclusion : La voie intra-osseuse s'avère fiable et rapide pour obtenir un accès vasculaire, avec un taux de complications très faible et permet l'administration d'un grand nombre de substances. D'autres études sont nécessaires pour évaluer l'impact de la voie intra osseuse, notamment en termes de mortalité, de complications tardives, ainsi que d'analyse coût/bénéfice de ce matériel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Current indications for therapeutic hypothermia (TH) are restricted to comatose patients with cardiac arrest (CA) due to ventricular fibrillation (VF) and without circulatory shock. Additional studies are needed to evaluate the benefit of this treatment in more heterogeneous groups of patients, including those with non-VF rhythms and/or shock and to identify early predictors of outcome in this setting. DESIGN: Prospective study, from December 2004 to October 2006. SETTING: 32-bed medico-surgical intensive care unit, university hospital. PATIENTS: Comatose patients with out-of-hospital CA. INTERVENTIONS: TH to 33 +/- 1 degrees C (external cooling, 24 hrs) was administered to patients resuscitated from CA due to VF and non-VF (including asystole or pulseless electrical activity), independently from the presence of shock. MEASUREMENTS AND MAIN RESULTS: We hypothesized that simple clinical criteria available on hospital admission (initial arrest rhythm, duration of CA, and presence of shock) might help to identify patients who eventually survive and might most benefit from TH. For this purpose, outcome was related to these predefined variables. Seventy-four patients (VF 38, non-VF 36) were included; 46% had circulatory shock. Median duration of CA (time from collapse to return of spontaneous circulation [ROSC]) was 25 mins. Overall survival was 39.2%. However, only 3.1% of patients with time to ROSC > 25 mins survived, as compared to 65.7% with time to ROSC < or = 25 mins. Using a logistic regression analysis, time from collapse to ROSC, but not initial arrest rhythm or presence of shock, independently predicted survival at hospital discharge. CONCLUSIONS: Time from collapse to ROSC is strongly associated with outcome following VF and non-VF cardiac arrest treated with therapeutic hypothermia and could therefore be helpful to identify patients who benefit most from active induced cooling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of electronic control devices has expanded worldwide during the last few years, the most widely used model being the Taser. However, the scientific knowledge about electronic control devices remains limited. We reviewed the medical literature to examine the potential implications of electronic devices in terms of morbidity and mortality, and to identify and evaluate all the existing experimental human studies. A single exposure of an electronic control device on healthy individuals can be assumed to be generally safe, according to 23 prospective human experimental studies and numerous volunteer exposures. In case series, however, electronic control devices could have deleterious effects when used in the field, in particular if persons receive multiple exposures, are intoxicated, show signs of "excited delirium," or present with medical comorbidities. As the use of electronic control devices continues to increase, the controversy about its safety, notably in potentially high-risk individuals, is still a matter of debate. The complications of electronic control device exposure are numerous but often recognizable, usually resulting from barbed dart injuries or from falls. Persons exposed to electronic control devices should therefore be fully examined, and traumatic lesions must be ruled out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Proper and rapid diagnosis of orthopedic device-related infection is important for successful treatment. Sonication has been shown to improve the diagnostic performance. We hypothesized that the combination of sonication with a novel method called microcalorimetry will further improve and accelerate the diagnosis of implant infection. We prospectively included 39 consecutive patients (mean age 59 years, 62% males) at our institution from whom 29 orthopedic prostheses and 10 osteosynthesis material were explanted. The explanted device was sonicated. The resulting sonication fluid was analyzed using microcalorimetry. Using standardized criteria to define orthopedic device-related infection, 12 cases (31%) were defined as infected. In all, positive periprosthetic tissue cultures were found. The sensitivity and specificity of microcalorimetry of sonication fluid were 100% and 97%, respectively. Mean time to detection, defined as time to reach a rising heat flow signal of 20 µW measured after equilibiration needed to get accurate measurement, was 10.9 h. In summary, microcalorimetry of sonication fluid is a reliable and a fast method in detecting the presence of microorganisms in orthopedic device-related infection. © 2013 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 31:1700-1703, 2013.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: To document the prevalence of asynchrony events during noninvasive ventilation in pressure support in infants and in children and to compare the results with neurally adjusted ventilatory assist. DESIGN: Prospective randomized cross-over study in children undergoing noninvasive ventilation. SETTING: The study was performed in a PICU. PATIENTS: From 4 weeks to 5 years. INTERVENTIONS: Two consecutive ventilation periods (pressure support and neurally adjusted ventilatory assist) were applied in random order. During pressure support (PS), three levels of expiratory trigger (ETS) setting were compared: initial ETS (PSinit), and ETS value decreased and increased by 15%. Of the three sessions, the period allowing for the lowest number of asynchrony events was defined as PSbest. Neurally adjusted ventilator assist level was adjusted to match the maximum airway pressure during PSinit. Positive end-expiratory pressure was the same during pressure support and neurally adjusted ventilator assist. Asynchrony events, trigger delay, and cycling-off delay were quantified for each period. RESULTS: Six infants and children were studied. Trigger delay was lower with neurally adjusted ventilator assist versus PSinit and PSbest (61 ms [56-79] vs 149 ms [134-180] and 146 ms [101-162]; p = 0.001 and 0.02, respectively). Inspiratory time in excess showed a trend to be shorter during pressure support versus neurally adjusted ventilator assist. Main asynchrony events during PSinit were autotriggering (4.8/min [1.7-12]), ineffective efforts (9.9/min [1.7-18]), and premature cycling (6.3/min [3.2-18.7]). Premature cycling (3.4/min [1.1-7.7]) was less frequent during PSbest versus PSinit (p = 0.059). The asynchrony index was significantly lower during PSbest versus PSinit (40% [28-65] vs 65.5% [42-76], p < 0.001). With neurally adjusted ventilator assist, all types of asynchronies except double triggering were reduced. The asynchrony index was lower with neurally adjusted ventilator assist (2.3% [0.7-5] vs PSinit and PSbest, p < 0.05 for both comparisons). CONCLUSION: Asynchrony events are frequent during noninvasive ventilation with pressure support in infants and in children despite adjusting the cycling-off criterion. Compared with pressure support, neurally adjusted ventilator assist allows improving patient-ventilator synchrony by reducing trigger delay and the number of asynchrony events. Further studies should determine the clinical impact of these findings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Forty-six consecutive patients with pulmonary embolism (PE) who underwent pulmonary angiography, helical computed tomography (CT), and echocardiography in the investigators' emergency department were studied. It was determined that the CT right ventricular (RV)/left ventricular (LV) end-diastolic area ratio was correlated with PE obstruction and echocardiography. A CT RV/LV area ratio &gt;1 had a sensitivity of 88% and a specificity of 88% in diagnosing significant PE. The present study suggests that helical CT may be used as a triage tool in acute PE for selecting high-risk patients, using calculation of the RV/LV area ratio to detect RV dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The production and use of false identity and travel documents in organized crime represent a serious and evolving threat. However, a case-by-case perspective, thus suffering from linkage blindness and a limited analysis capacity, essentially drives the present-day fight against this criminal problem. To assist in overcoming these limitations, a process model was developed using a forensic perspective. It guides the systematic analysis and management of seized false documents to generate forensic intelligence that supports strategic and tactical decision-making in an intelligence-led policing approach. The model is articulated on a three-level architecture that aims to assist in detecting and following-up on general trends, production methods and links between cases or series. Using analyses of a large dataset of counterfeit and forged identity and travel documents, it is possible to illustrate the model, its three levels and their contribution. Examples will point out how the proposed approach assists in detecting emerging trends, in evaluating the black market's degree of structure, in uncovering criminal networks, in monitoring the quality of false documents, and in identifying their weaknesses to orient the conception of more secured travel and identity documents. The process model proposed is thought to have a general application in forensic science and can readily be transposed to other fields of study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Résumé: La qualité de l'implantation d'une prothèse totale du genou est un facteur essentiel déterminant le résultat clinique à long terme. L'alignement postopératoire des membres inférieurs est considéré comme le facteur influençant le plus la survie à long terme d'une arthroplastie du genou. Au vu du haut degré de corrélation entre les complications post-opératoires et les malpositionnements prothétiques, les chirurgiens ont tenté de développer durant ces deux dernières décennies des instruments chirurgicaux améliorant la précision d'implantation. Depuis le début des années 90, de nouvelles instrumentations assistées par ordinateur ont été proposées. Actuellement, en chirurgie prothétique du genou, la plus utilisée de ces techniques est le système de navigation OrthoPilot® qui permet, grâce à une station de navigation et des émetteurs infrarouges, de contrôler en continu pendant l'opération, l'axe mécanique du membre inférieur et de vérifier la précision des coupes osseuses. Le but de cette étude de cohorte appareillée rétrospective est de comparer les résultats clinique et radiologiques de deux collectifs de patients (32 patients dans chaque groupe) comparables (âge, sexe, BMI, degré d'arthrose, recul postopératoire), opérés avec le même type de prothèse (prothèse à glissement tricompartimental postérieurement stabilisée), soit avec le système de navigation Orthopilot®, soit à l'aide de l'instrumentation ancillaire mécanique classique. Les résultats obtenus montrent que la technique chirurgicale supportée par le système de navigation Orthopilot® est fiable et aisément reproductible. Par rapport à l'instrumentation manuelle, l'instrumentation assistée améliore significativement la précision de pose du composant tibial dans le plan frontal. Cependant entre des mains expérimentées, la technique d'alignement mécanique classique, plus simple, reste performante (coût modique, temps opératoire plus court et sans risque de défaillance technique).