218 resultados para safety monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Applications of genetic constructs with multiple promoters, which are fused with reporter genes and simultaneous monitoring of various events in cells, have gained special attention in recent years. Lentiviral vectors, with their distinctive characteristics, have been considered to monitor the developmental changes of cells in vitro. In this study, we constructed a novel lentiviral vector (FUM-M), containing two germ cell-specific promoters (Stra8 and c-kit), fused with ZsGreen and DsRed2 reporter genes, and evaluated its efficiency in different cells following treatments with retinoic acid and DMSO. Several cell lines (P19, GC-1 spg and HEK293T) were transduced with this vector, and functional capabilities of the promoters were verified by flow cytometry and quantitative RT-PCR. Our results indicate that FUM-M shows dynamic behavior in the presence and absence of extrinsic factors. A correlation was also observed between the function of promoters, present in the lentiviral construct and the endogenous level of the Stra8 and c-kit mRNAs in the cells. In conclusion, we recommend this strategy, which needs further optimization of the constructs, as a beneficial and practical way to screen chemical inducers involved in cellular differentiation toward germ-like cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hemoglobin concentration is one of the principal factors of aerobic power and, consequently, of performance in many types of physical activities. The use of recombinant human erythropoietin is, therefore, particularly powerful for improving the physical performances of patients, and, more generally, improving their quality of life. This article discusses procedures for monitoring recombinant erythropoietin and its analogues in doping for athletic performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simultaneous recording of scalp electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) can provide unique insights into the dynamics of human brain function, and the increased functional sensitivity offered by ultra-high field fMRI opens exciting perspectives for the future of this multimodal approach. However, simultaneous recordings are susceptible to various types of artifacts, many of which scale with magnetic field strength and can seriously compromise both EEG and fMRI data quality in recordings above 3T. The aim of the present study was to implement and characterize an optimized setup for simultaneous EEG-fMRI in humans at 7T. The effects of EEG cable length and geometry for signal transmission between the cap and amplifiers were assessed in a phantom model, with specific attention to noise contributions from the MR scanner coldheads. Cable shortening (down to 12cm from cap to amplifiers) and bundling effectively reduced environment noise by up to 84% in average power and 91% in inter-channel power variability. Subject safety was assessed and confirmed via numerical simulations of RF power distribution and temperature measurements on a phantom model, building on the limited existing literature at ultra-high field. MRI data degradation effects due to the EEG system were characterized via B0 and B1(+) field mapping on a human volunteer, demonstrating important, although not prohibitive, B1 disruption effects. With the optimized setup, simultaneous EEG-fMRI acquisitions were performed on 5 healthy volunteers undergoing two visual paradigms: an eyes-open/eyes-closed task, and a visual evoked potential (VEP) paradigm using reversing-checkerboard stimulation. EEG data exhibited clear occipital alpha modulation and average VEPs, respectively, with concomitant BOLD signal changes. On a single-trial level, alpha power variations could be observed with relative confidence on all trials; VEP detection was more limited, although statistically significant responses could be detected in more than 50% of trials for every subject. Overall, we conclude that the proposed setup is well suited for simultaneous EEG-fMRI at 7T.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Verbal auditory hallucinations can have a strong impact on the social and professional functioning of individuals diagnosed with schizophrenia. The safety-seeking behaviours used to reduce the threat associated with voices play a significant role in explaining the functional consequences of auditory hallucinations. Nevertheless, these safety-seeking behaviours have been little studied. Twenty-eight patients with schizophrenia and verbal auditory hallucinations were recruited for this study. Hallucinations were evaluated using the Psychotic Symptom Rating Scale and the Belief About Voice Questionnaire and safety behaviours using a modified version of the Safety Behaviour Questionnaire. Our results show that the vast majority of patients relies on safety behaviours to reduce the threat associated with voices. This reliance on safety behaviours is mostly explained by beliefs about origin of voices the omnipotence attributed to hallucinations and the behavioural and emotional reactions to the voices. Safety-seeking behaviours play an important role in maintaining dysfunctional beliefs with respect to voices. They should be better targeted within the cognitive and behavioural therapies for auditory hallucinations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Therapeutic drug monitoring (TDM), i.e., the quantification of serum or plasma concentrations of medications for dose optimization, has proven a valuable tool for the patient-matched psychopharmacotherapy. Uncertain drug adherence, suboptimal tolerability, non-response at therapeutic doses, or pharmacokinetic drug-drug interactions are typical situations when measurement of medication concentrations is helpful. Patient populations that may predominantly benefit from TDM in psychiatry are children, pregnant women, elderly patients, individuals with intelligence disabilities, forensic patients, patients with known or suspected genetically determined pharmacokinetic abnormalities or individuals with pharmacokinetically relevant comorbidities. However, the potential benefits of TDM for optimization of pharmacotherapy can only be obtained if the method is adequately integrated into the clinical treatment process. To promote an appropriate use of TDM, the TDM expert group of the Arbeitsgemeinschaft für Neuropsychopharmakologie und Pharmakopsychiatrie (AGNP) issued guidelines for TDM in psychiatry in 2004. Since then, knowledge has advanced significantly, and new psychopharmacologic agents have been introduced that are also candidates for TDM. Therefore the TDM consensus guidelines were updated and extended to 128 neuropsychiatric drugs. 4 levels of recommendation for using TDM were defined ranging from "strongly recommended" to "potentially useful". Evidence-based "therapeutic reference ranges" and "dose related reference ranges" were elaborated after an extensive literature search and a structured internal review process. A "laboratory alert level" was introduced, i.e., a plasma level at or above which the laboratory should immediately inform the treating physician. Supportive information such as cytochrome P450 substrateand inhibitor properties of medications, normal ranges of ratios of concentrations of drug metabolite to parent drug and recommendations for the interpretative services are given. Recommendations when to combine TDM with pharmacogenetic tests are also provided. Following the guidelines will help to improve the outcomes of psychopharmacotherapy of many patients especially in case of pharmacokinetic problems. Thereby, one should never forget that TDM is an interdisciplinary task that sometimes requires the respectful discussion of apparently discrepant data so that, ultimately, the patient can profit from such a joint effort.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To ensure successful treatment, HIV patients must maintain a high degree of medication adherence over time. Since August 2004, patients who are (or are at risk of) experiencing problems with their HIV antiretroviral therapy (ART) have been referred by their physicians to an interdisciplinary HIV-adherence program. The program consists of a multifactorial intervention along with electronic drug monitoring (MEMS(TM)). The pharmacists organize individualized semi-structured motivational interviews based on cognitive, emotional, behavioral, and social issues. At the end of each session, the patient brings an adherence report to the physician. This enables the physician to use the adherence results to evaluate the treatment plan. The aim of this study was to retrospectively analyze this on-going interdisciplinary HIV-adherence program. All patients who were included between August 2004 and the end of April 2008 were analyzed. One hundred and four patients were included (59% women, median age 39 (31.0, 46.0) years, 42% black ethnicity). Eighty (77%) patients were ART-experienced patients and 59% had a protease inhibitor-based treatment. The retention rate was high (92%) in the program. Patient inclusion in this HIV-adherence program was determined by patient issues for naive patients and by nonadherence or suboptimal clinical outcomes for ART-experienced patients. The median time spent by a subject at the pharmacy was 35 (25.0, 48.0) minutes, half for the medication handling and half for the interview. The adherence results showed a persistence of 87% and an execution of 88%. Proportion of undetectable subjects increased during study. In conclusion, retention and persistence rates were high in this highly selected problematic population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Monitoring of internal exposure for nuclear medicine workers requires frequent measurements due to the short physical half-lives of most radionuclides used in this field. The aim of this study was to develop screening measurements performed at the workplace by local staff using standard laboratory instrumentation, to detect whether potential intake has occurred. Such measurements do not enable to determine the committed effective dose, but are adequate to verify that a given threshold is not exceeded. For radioiodine, i.e. (123)I, (124)I, (125)I and (131)I, a calibrated surface contamination monitor is placed in front of the thyroid to detect whether the activity threshold has been exceeded. For radionuclides with very short physical half-lives (≤6 h), such as (99m)Tc and those used in positron emission tomography  imaging, i.e. (11)C, (15)O, (18)F and (68)Ga, screening procedures consist in performing daily measurements of the ambient dose rate in front of the abdomen. Other gamma emitters used for imaging, i.e. (67)Ga, (111)In and (201)Tl, are measured with a scintillation detector located in front of the thorax. For pure beta emitters, i.e. (90)Y and (169)Er, as well as beta emitters with low-intensity gamma rays, i.e. (153)Sm, (177)Lu, (186)Re and (188)Re, the procedure consists in measuring hand contamination immediately after use. In Switzerland, screening procedures have been adopted by most nuclear medicine services since such measurements enable an acceptable monitoring while taking into account practical and economic considerations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objectives In humans, circulating CD4(+)CD25(high) T cells contain mainly regulatory T cells (Treg; FoxP3(+)IL-7R alpha(low)), but a small subset is represented by activated effector T cells (Tact; FoxP3(-)IL-7R alpha(high)). The balance between Tact and Treg may be important after transplantation. The aim of this study was first to analyze and correlate CD4(+)CD25(high) Tact and Treg with the clinical status of kidney transplant recipients and second to study prospectively the effect of two immunosuppressive regimens on Tact/Treg during the first year after transplantation.Design, setting, participants, & measurements CD4(+)CD25(high) Tact and Treg were analyzed by flow cytometry, either retrospectively in 90 patients greater than 1 year after kidney transplantation (cross-sectional analysis) or prospectively in 35 patients receiving two immunosuppressive regimens after kidney transplantation (prospective analysis).Results A higher proportion of Tact and a lower proportion of Treg were found in the majority of kidney recipients. In chronic Immoral rejection, a strikingly higher proportion of Tact was present. A subgroup of stable recipients receiving calcineurin inhibitor-free immunosuppression (mycophenolate mofetil, azathioprine, or sirolimus) had Tact values that were similar to healthy individuals. In the prospective analysis, the proportion of Tact significantly increased in both immunosuppression groups during the first year after transplantation.Conclusions These data highlight distinct patterns in the proportion of circulating Tact depending on the clinical status of kidney recipients. Moreover, the prospective analysis demonstrated an increase in the proportion of Tact, regardless of the immunosuppressive regimen. The measurement of Tact, in addition to Treg, may become a useful immune monitoring tool after kidney transplantation. Clin J Am Soc Nephrol 6: 2025-2033, 2011. doi: 10.2215/CJN.09611010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: European Surveillance of Congenital Anomalies (EUROCAT) is a network of population-based congenital anomaly registries in Europe surveying more than 1 million births per year, or 25% of the births in the European Union. This paper describes the potential of the EUROCAT collaboration for pharmacoepidemiology and drug safety surveillance. METHODS: The 34 full members and 6 associate members of the EUROCAT network were sent a questionnaire about their data sources on drug exposure and on drug coding. Available data on drug exposure during the first trimester available in the central EUROCAT database for the years 1996-2000 was summarised for 15 out of 25 responding full members. RESULTS: Of the 40 registries, 29 returned questionnaires (25 full and 4 associate members). Four of these registries do not collect data on maternal drug use. Of the full members, 15 registries use the EUROCAT drug code, 4 use the international ATC drug code, 3 registries use another coding system and 7 use a combination of these coding systems. Obstetric records are the most frequently used sources of drug information for the registries, followed by interviews with the mother. Only one registry uses pharmacy data. Percentages of cases with drug exposure (excluding vitamins/minerals) varied from 4.4% to 26.0% among different registries. The categories of drugs recorded varied widely between registries. CONCLUSIONS: Practices vary widely between registries regarding recording drug exposure information. EUROCAT has the potential to be an effective collaborative framework to contribute to post-marketing drug surveillance in relation to teratogenic effects, but work is needed to implement ATC drug coding more widely, and to diversify the sources of information used to determine drug exposure in each registry.