162 resultados para measurement equipment
Resumo:
Purpose: To evaluate the reproducibility of Cirrus-SD OCT measurements and to compare central macular thickness (CMT) measurements between TD-Stratus and SD-Cirrus OCT in patients with active exudative AMD. Methods: Consecutive case series of patients with active exudative AMD seen in the Medical Retina Department. Patients underwent 1 scan with Stratus (macular thickness map protocol) and 5 scans with Cirrus (Macular Cube protocol) at the same visit by the same experienced examiner. To be included, patients best-corrected visual acuity (BCVA) had to be >20/200 while all scans had to be of sufficient quality, well-centered and at least one Cirrus scan with CMT >300 microns. The repeatability of the SD Cirrus was estimated by using all 5 CMT measurements and the mean of the Cirrus measurements was compared with the CMT obtained by TD Stratus. Results: Cirrus OCT demonstrated high intraobserver repeatability at the central foveal region (ICC 96%). The mean of the CMT measurements was 321microns for Stratus and 387 microns for Cirrus. The average difference was 65m (SD=30). The coefficient of concordance between Stratus and Cirrus CMT measurements was rho=0,749 with a high precision and a moderate accuracy. The equation of the line of regression between Stratus and meanCirrus is given by the following: M_stratus = 0,848 x m_cirrus - 4,496 (1).Conclusions: The Cirrus macular cube protocol allows reproducible CMT measurements in patients with active exudative AMD. In cases of upgrading from TD to SD use and vice versa, there is the possibility to predict the measurements by using the equation (1). These real life data and conclusions can help in improving our clinical management of patients with neovascular AMD.
Resumo:
Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 ?g/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 ?g/ml) ?cdr1 ?cdr2 ?flu ?mdr1 ?can constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 ?g/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 ?g/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.
Resumo:
Combining bacterial bioreporters with microfluidics systems holds great promise for in-field detection of chemical or toxicity targets. Recently we showed how Escherichia coli cells engineered to produce a variant of green fluorescent protein after contact to arsenite and arsenate can be encapsulated in agarose beads and incorporated into a microfluidic chip to create a device for in-field detection of arsenic, a contaminant of well known toxicity and carcinogenicity in potable water both in industrialized and developing countries. Cell-beads stored in the microfluidics chip at -20°C retained inducibility up to one month and we were able to reproducibly discriminate concentrations of 10 and 50 μg arsenite per L (the drinking water standards for European countries and the United States, and for the developing countries, respectively) from the blank in less than 200 minutes. We discuss here the reasons for decreasing bioreporter signal development upon increased storage of cell beads but also show how this decrease can be reduced, leading to a faster detection and a longer lifetime of the device.
Resumo:
Introduction: « Osteo-Mobile Vaud » is a mobile osteoporosis (OP) screening program. The women > 60 years living in the region Vaud will be offered OP screening with new equipment installed in a bus. The main goal is to evaluate the fracture risk with the combination of clinical risk factors (CRF) and informations extracted by a single DXA: bone mineral density (BMD), vertebral fracture assessment (VFA), and micro-architecture (MA) evaluation. MA is yet evaluable in daily practice by the Trabecular Bone Score (TBS) measure. TBS is a novel grey-level texture measurement reflecting bone MA based on the use of experimental variograms of 2D projection images. TBS is very simple to obtain, by reanalyzing a lumbar DXA-scan. TBS has proven to have diagnosis and prognosis value, partially independent of CRF and BMD. A 55-years follow- up is planned. Method: The Osteo-Mobile Vaud cohort (1500 women, > 60 years, living in the region Vaud) started in July 2010. CRF for OP, lumbar spine and hip BMD, VFA by DXA and MA evaluation by TBS are recorded. Preliminary results are reported. Results: In July 31th, we evaluated 510 women: mean age 67 years, BMI 26 kg/m². 72 women had one or more fragility fractures, 39 had vertebral fracture (VFx) grade 2/3. TBS decreases with age (-0.005 / year, p<0.001), and with BMI (-0.011 per kg/m², p<0.001). Correlation between BMD and site matched TBS is low (r=0.4, p<0.001). For the lowest T-score BMD, odds ratio (OR, 95% CI) for VFx grade 2/3 and clinical OP Fx are 1.8 (1.1-2.9) and 2.3 (1.5-3.4). For TBS, age-, BMI- and BMD adjusted ORs (per SD decrease) for VFx grade 2/3 and clinical OP Fx are 1.9 (1.2-3.0) and 1.8 (1.2-2.7). The TBS added value was independent of lumbar spine BMD or the lowest T-score (femoral neck, total hip or lumbar spine). Conclusion: As in the already published studies, these preliminary results confirm the partial independence between BMD and TBS. More importantly, a combination of TBS and BMD may increase significantly the identification of women with prevalent OP Fx. For the first time we are able to have complementary information about fracture (VFA), density (BMD), and micro-architecture (TBS) from a simple, low ionizing radiation and cheap device: DXA. The value of such informations in a screening program will be evaluated.
Resumo:
Résumé: Dans le contexte d'un climat de plus en plus chaud, la localisation du pergélisol dans les terrains sédimentaires à forte déclivité et l'évaluation des mouvements de terrain qui y ont cours s'avèrent primordiales. S'insérant dans cette problématique, ce travail de thèse s'articule autour de deux axes de recherche différents. D'un point de vue statique, cette recherche propose une étude de la distribution et des caractéristiques du pergélisol dans les éboulis de la zone périglaciaire alpine. D'un point de vue dynamique, une analyse de l'influence des caractéristiques du pergélisol (teneur en glace, température du pergélisol, etc.) et des variations des températures de l'air et du sol sur les vitesses de fluage des corps sédimentaires gelés est effectuée. Afin de répondre à ce double objectif, l'approche "terrain" a été privilégiée. Pour déterminer la répartition et les caractéristiques du pergélisol, les méthodes traditionnelles de prospection du pergélisol ont été utilisées, à savoir la mesure de la température du sol à la base du manteau neigeux (BTS), la mesure de la température du sol en continu ainsi que la méthode géoélectrique. Les mouvements de terrain ont pour leur part été mesurés à l'aide d'un GPS différentiel. L'étude de la distribution du pergélisol a été effectuée dans une quinzaine d'éboulis situés dans les régions du Mont Gelé (Verbier-Nendaz) et d'Arolla principalement. Dans la plupart des cas, un pergélisol a pu être mis en évidence dans la partie inférieure des accumulations sédimentaires, alors que la partie médiane des éboulis n'est, le plus souvent, pas gelée. Si cette absence de pergélisol se prolonge parfois dans les portions sommitales des pentes, les mesures réalisées montrent que dans d'autres cas des sédiments gelés y sont à nouveau présents. Les résistivités électriques mesurées dans les portions gelées des éboulis étudiés sont dans la plupart des cas nettement inférieures à celles mesurées sur les glaciers rocheux. Des études préalables ont montré que des circulations d'air internes sont responsables de l'anomalie thermique négative et, lorsqu'il existe, du pergélisol que l'on trouve dans la partie inférieure d'éboulis situés plus de 1000 m plus bas que la limite inférieure régionale du pergélisol discontinu. L'étude de quatre sites de basse altitude (1400-1900 m), et notamment l'équipement du site de Dreveneuse (Préalpes Valaisannes) avec deux forages, des capteurs de température de surface et un anémomètre a permis de vérifier et de préciser le mécanisme de ventilation actif au sein des éboulis froids de basse altitude. Ce mécanisme fonctionne de la manière suivante: en hiver, l'air contenu dans l'éboulis, plus chaud et plus léger que l'air extérieur, monte à l'intérieur de l'accumulation sédimentaire et est expulsé dans ses parties sommitales. Cet effet de cheminée provoque une aspiration d'air froid à l'intérieur de la partie inférieure de l'éboulis, causant ainsi un sur-refroidissement marqué du terrain. En été, le mécanisme s'inverse, l'éboulis étant plus froid que l'air environnant. De l'air froid est alors expulsé au bas de la pente. Une ventilation ascendante hivernale a pu être mise en évidence dans certains des éboulis de haute altitude étudiés. Elle est probablement en grande partie responsable de la configuration particulière des zones gelées observées. Même si l'existence d'un effet de cheminée n'a pu être démontrée dans tous les cas, du fait notamment de la glace interstitielle qui entrave le cheminement de l'air, des indices laissant présager son possible fonctionnement existent dans la quasi totalité des éboulis étudiés. L'absence de pergélisol à des altitudes qui lui sont favorables pourrait en tous les cas s'expliquer par un réchauffement du terrain lié à des expulsions d'air relativement chaud. L'étude des mouvements de terrain a été effectuée sur une dizaine de sites, principalement sur des glaciers rocheux, mais également sur une moraine de poussée et - II - Résumé ? abstract quelques éboulis. Plusieurs glaciers rocheux présentent des formes de déstabilisation récente (niches d'arrachement, blocs basculés, apparition de la matrice fine à la surface, etc.), ce qui témoigne d'une récente accélération des vitesses de déplacement. Ce phénomène, qui semble général à l'échelle alpine, est probablement à mettre sur le compte du réchauffement du pergélisol depuis une vingtaine d'années. Les vitesses mesurées sur ces formations sont souvent plus élevées que les valeurs habituellement proposées dans la littérature. On note par ailleurs une forte variabilité inter-annuelle des vitesses, qui semblent dépendre de la variation de la température moyenne annuelle de surface. Abstract: In the context of a warmer climate, the localisation of permafrost in steep sedimentary terrain and the measurement of terrain movements that occur in these areas is of great importance. With respect to these problems, this PhD thesis follows two different research axes. From a static point of view, the research presents a study of the permafrost distribution and characteristics in the talus slopes of the alpine periglacial belt. From a dynamic point of view, an analysis of the influence of the permafrost characteristics (ice content, permafrost temperature, etc.) and air and soil temperature variations on the creep velocities of frozen sedimentary bodies is carried out. In order to attain this double objective, the "field" approach was favoured. To determine the distribution and the characteristics of permafrost, the traditional methods of permafrost prospecting were used, i.e. ground surface temperature measurements at the base of the snow cover (BTS), year-round ground temperature measurements and DC-resistivity prospecting. The terrain movements were measured using a differential GPS. The permafrost distribution study was carried out on 15 talus slopes located mainly in the Mont Gelé (Verbier-Nendaz) and Arolla areas (Swiss Alps). In most cases, permafrost was found in the lower part of the talus slope, whereas the medium part was free of ice. In some cases, the upper part of the talus is also free of permafrost, whereas in other cases permafrost is present. Electrical resistivities measured in the frozen parts of the studied talus are in most cases clearly lower than those measured on rock glaciers. Former studies have shown that internal air circulation is responsible for the negative thermal anomaly and, when it exists, the permafrost present in the lower part of talus slopes located more than 1000 m below the regional lower limit of discontinuous permafrost. The study of four low-altitude talus slopes (1400-1900 m), and notably the equipment of Dreveneuse field site (Valais Prealps) with two boreholes, surface temperature sensors and an anemometer permitted to verify and to detail the ventilation mechanism active in low altitude talus slopes. This mechanism works in the following way: in winter, the air contained in the block accumulation is warmer and lighter than the surrounding air and therefore moves upward in the talus and is expelled in its upper part. This chimney effect induces an aspiration of cold air in the interior of the lower part of talus, that causes a strong overcooling of the ground. In summer, the mechanism is reversed because the talus slope is colder than the surrounding air. Cold air is then expelled in the lower part of the slope. Evidence of ascending ventilation in wintertime could also be found in some of the studied high-altitude talus slopes. It is probably mainly responsible for the particular configuration of the observed frozen areas. Even if the existence of a chimney effect could not be demonstrated in all cases, notably because of interstitial ice that obstructs Résumé ? abstract - III - the air circulation, indices of its presence exist in nearly all the studied talus. The absence of permafrost at altitudes favourable to its presence could be explained, for example, by the terrain warming caused by expulsion of relatively warm air. Terrain movements were measured at about ten sites, mainly on rock glaciers, but also on a push moraine and some talus slopes. Field observations reveal that many rock glaciers display recent destabilization features (landslide scars, tilted blocks, presence of fine grained sediments at the surface, etc.) that indicate a probable recent acceleration of the creep velocities. This phenomenon, which seems to be widespread at the alpine scale, is probably linked to the permafrost warming during the last decades. The measured velocities are often higher than values usually proposed in the literature. In addition, strong inter-annual variations of the velocities were observed, which seems to depend on the mean annual ground temperature variations.
Resumo:
The introduction of affordable, consumer-oriented 3-D printers is a milestone in the current "maker movement," which has been heralded as the next industrial revolution. Combined with free and open sharing of detailed design blueprints and accessible development tools, rapid prototypes of complex products can now be assembled in one's own garage--a game-changer reminiscent of the early days of personal computing. At the same time, 3-D printing has also allowed the scientific and engineering community to build the "little things" that help a lab get up and running much faster and easier than ever before.
Resumo:
Postmortem human chorionic gonadotrophin (HCG) blood assay can confirm postmortem diagnosis of pregnancy or document situations in which HCG levels are elevated. In some cases, however, blood sampling is not possible at autopsy. In this study, HCG was quantified by enzyme-linked fluorescent assay (ELFA) in the bile (n = 5), vitreous humor (n = 4), and postmortem blood (n = 4) of five pregnant women. There were no false negatives in the pregnant subjects (n = 5) or false positives in controls (n = 34), enabling this test to be recommended for routine use in forensic contexts in which the detection of elevated HCG levels could be of interest.
Resumo:
BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
Resumo:
Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.
Resumo:
Issue ownership means that some parties are considered by the public at large as being more able to deal with, or more attentive to, certain issues. The theory has been used to explain both party behaviour - parties are expected to focus on owned issues - and voter behaviour - when a voter considers a party to own an issue, this affects the odds of voting for that party. The purpose of this article is, first, to provide a look backward at the existing research through a literature review of the studies that were conducted in the past decade-and-a-half. Secondly, it takes stock of the current conceptualisation and argues that issue ownership is a multidimensional concept. Thereafter the article discusses how this multidimensionality affects both the role of issue ownership in voter and in party behaviour. Finally, the article outlines a number of shortcomings of the extant literature and discusses potential avenues for future research.
Resumo:
Reaching a consensus in terms of interchangeability and utility (i.e., disease detection/monitoring) of a medical device is the eventual aim of repeatability and agreement studies. The aim of the tolerance and relative utility indices described in this report is to provide a methodology to compare change in clinical measurement noise between different populations (repeatability) or measurement methods (agreement), so as to highlight problematic areas. No longitudinal data are required to calculate these indices. Both indices establish a metric of least to most effected across all parameters to facilitate comparison. If validated, these indices may prove useful tools when combining reports and forming the consensus required in the validation process for software updates and new medical devices.