147 resultados para balloon dilatation
Resumo:
BACKGROUND: Left atrial (LA) dilatation is associated with a large variety of cardiac diseases. Current cardiovascular magnetic resonance (CMR) strategies to measure LA volumes are based on multi-breath-hold multi-slice acquisitions, which are time-consuming and susceptible to misregistration. AIM: To develop a time-efficient single breath-hold 3D CMR acquisition and reconstruction method to precisely measure LA volumes and function. METHODS: A highly accelerated compressed-sensing multi-slice cine sequence (CS-cineCMR) was combined with a non-model-based 3D reconstruction method to measure LA volumes with high temporal and spatial resolution during a single breath-hold. This approach was validated in LA phantoms of different shapes and applied in 3 patients. In addition, the influence of slice orientations on accuracy was evaluated in the LA phantoms for the new approach in comparison with a conventional model-based biplane area-length reconstruction. As a reference in patients, a self-navigated high-resolution whole-heart 3D dataset (3D-HR-CMR) was acquired during mid-diastole to yield accurate LA volumes. RESULTS: Phantom studies. LA volumes were accurately measured by CS-cineCMR with a mean difference of -4.73 ± 1.75 ml (-8.67 ± 3.54%, r2 = 0.94). For the new method the calculated volumes were not significantly different when different orientations of the CS-cineCMR slices were applied to cover the LA phantoms. Long-axis "aligned" vs "not aligned" with the phantom long-axis yielded similar differences vs the reference volume (-4.87 ± 1.73 ml vs. -4.45 ± 1.97 ml, p = 0.67) and short-axis "perpendicular" vs. "not-perpendicular" with the LA long-axis (-4.72 ± 1.66 ml vs. -4.75 ± 2.13 ml; p = 0.98). The conventional bi-plane area-length method was susceptible for slice orientations (p = 0.0085 for the interaction of "slice orientation" and "reconstruction technique", 2-way ANOVA for repeated measures). To use the 3D-HR-CMR as the reference for LA volumes in patients, it was validated in the LA phantoms (mean difference: -1.37 ± 1.35 ml, -2.38 ± 2.44%, r2 = 0.97). Patient study: The CS-cineCMR LA volumes of the mid-diastolic frame matched closely with the reference LA volume (measured by 3D-HR-CMR) with a difference of -2.66 ± 6.5 ml (3.0% underestimation; true LA volumes: 63 ml, 62 ml, and 395 ml). Finally, a high intra- and inter-observer agreement for maximal and minimal LA volume measurement is also shown. CONCLUSIONS: The proposed method combines a highly accelerated single-breathhold compressed-sensing multi-slice CMR technique with a non-model-based 3D reconstruction to accurately and reproducibly measure LA volumes and function.
Resumo:
BACKGROUND: Remodeling of quiescent vessels with increases in permeability, vasodilatation, and edema are hallmarks of inflammatory disorders. Factors involved in this type of remodeling represent potential therapeutic targets. OBJECTIVES: We investigated whether the nuclear hormone receptor peroxisome proliferator-activated receptor (PPAR) β/δ, a regulator of metabolism, fibrosis, and skin homeostasis, is involved in regulation of this type of remodeling. METHODS: Wild-type and various Pparb/d mutant mice were used to monitor dermal acute vascular hyperpermeability (AVH) and passive systemic anaphylaxis-induced hypothermia and edema. PPARβ/δ-dependent kinase activation and remodeling of endothelial cell-cell junctions were addressed by using human endothelial cells. RESULTS: AVH and dilatation of dermal microvessels stimulated by vascular endothelial growth factor A, histamine, and thrombin are severely compromised in PPARβ/δ-deficient mice. Selective deletion of the Pparb/d-encoding gene in endothelial cells in vivo similarly limits dermal AVH and vasodilatation, providing evidence that endothelial PPARβ/δ is the major player in regulating acute dermal microvessel remodeling. Furthermore, endothelial PPARβ/δ regulatory functions are not restricted to the skin vasculature because its deletion in the endothelium, but not in smooth muscle cells, also leads to reduced systemic anaphylaxis, the most severe form of allergic reaction, in which an acute vascular response plays a key role. PPARβ/δ-dependent AVH activation likely involves the activation of mitogen-activated protein kinase and Akt pathways and leads to downstream destabilization of endothelial cell-cell junctions. CONCLUSION: These results unveil not only a novel function of PPARβ/δ as a direct regulator of acute vessel permeability and dilatation but also provide evidence that antagonizing PPARβ/δ represents an important strategy to consider for moderating diseases with altered endothelial integrity, such as acute inflammatory and allergic disorders.
Resumo:
BACKGROUND AND OBJECTIVE: Gastroschisis is a congenital anomaly with increasing incidence, easy prenatal diagnosis and extremely variable postnatal outcomes. Our objective was to systematically review the evidence regarding the association between prenatal ultrasound signs (intraabdominal bowel dilatation [IABD], extraabdominal bowel dilatation, gastric dilatation [GD], bowel wall thickness, polyhydramnios, and small for gestational age) and perinatal outcomes in gastroschisis (bowel atresia, intra uterine death, neonatal death, time to full enteral feeding, length of total parenteral nutrition and length of in hospital stay). METHODS: Medline, Embase, and Cochrane databases were searched electronically. Studies exploring the association between antenatal ultrasound signs and outcomes in gastroschisis were considered suitable for inclusion. Two reviewers independently extracted relevant data regarding study characteristics and pregnancy outcome. All meta-analyses were computed using individual data random-effect logistic regression, with single study as the cluster unit. RESULTS: Twenty-six studies, including 2023 fetuses, were included. We found significant positive associations between IABD and bowel atresia (odds ratio [OR]: 5.48, 95% confidence interval [CI] 3.1-9.8), polyhydramnios and bowel atresia (OR: 3.76, 95% CI 1.7-8.3), and GD and neonatal death (OR: 5.58, 95% CI 1.3-24.1). No other ultrasound sign was significantly related to any other outcome. CONCLUSIONS: IABD, polyhydramnios, and GD can be used to an extent to identify a subgroup of neonates with a prenatal diagnosis of gastroschisis at higher risk to develop postnatal complications. Data are still inconclusive on the predictive ability of several signs combined, and large prospective studies are needed to improve the quality of prenatal counseling and the neonatal care for this condition.
Resumo:
PURPOSE: A surgical gastrostomy is mandatory in cases where a PEG is not feasible. Various minimally invasive techniques have been described, but many involve unusable materials in small children and/or have risk of disunion. We describe a technique for true Stamm gastrostomy performed by laparoscopy (LSG) with a purse string suture and four points of attachment onto the wall. METHOD: We reviewed 20 children who underwent an LSG from 2010 to 2013. After incision of the skin at the location planned for the gastrostomy, using three 3-5mm ports the stomach is fixed to the wall by three suspension stitches, which are entered and then emerged subcutaneously. A fourth stitch of attachment is used to make an award on the stomach and tie around the gastrostomy tube. RESULTS: Mean age was 4.2years, with 70% aged <2years. All children were malnourished, most often severely. All but two underwent a concomitant fundoplication. Feeding through the gastrostomy started on D0 or D1. Total feeding by gastrostomy was achieved in a mean duration of 2.9day. Mean hospital stay was 4.5days. There was no perioperative complication. Mean follow-up was 14months. Once, the balloon was accidently deflated and reinflated in the wall leading to its necrosis. Five peristomial granulomas were noticed. It was always possible to replace the tube by a gastrostomy device at least 6weeks after surgery. CONCLUSION: This new technique for true Stamm gastrostomy by laparoscopy reproduces exactly the one done by laparotomy, without special equipment. It can be made since the neonatal period, in all the circumstances when a laparoscopy is possible.
Resumo:
Case: A 11 yo girl with Marfan syndrome was referred to cardiac MR (CMR) to measure the size of her thoracic aorta. She had a typical phenotype with arachnodactyly, abnormally long arms, and was tall and slim (156 cm, 28 kg, body mass index 11,5 kg/m2). She complained of no symptoms. Cardiac auscultation revealed a prominent mid-systolic click and an end-systolic murmur at the apex. A recent echocardiogram showed a moderately dilated left ventricle with normal function and a mitral valve prolapse with moderate mitral valve regurgitation. CMR showed a dilatation of the aortic root (38 mm, Z-score 8.9) and a severe prolapse of the mitral valve with regurgitation. The ventricular cavity was moderately dilated (116 ml/m2) and its contraction was hyperdynamic (stroke volume (SV): 97 ml; LVEF 72%, with the LV volumes measured by modified Simpson method from the apex to the mitral annulus). In this patient however, the mitral prolapse was characterized by a severe backward movement of the valve toward the left atrium (LA) in systole and the dyskinetic movement of the atrioventricular plane caused a ventricularisation of a part of the LA in systole (Figure). This resulted in a significant reduction of LVEF: more than ¼ of the apparent SV was displaced backwards into the ventricularized LA volume, reducing the effective LVEF to 51% (effective SV 69ml). Moreover, by flow measurement, the SV across the ascending aorta was 30 ml (cardiac index 2.0 l/min/m2) allowing the calculation of a regurgitant fraction across the mitral valve of 56%, which was diagnostic for a severe mitral valve insufficiency. Conclusion: This case illustrates the phenomenon of a ventricularisation of the LA where the severe prolapse gives the illusion of a higher attachement of the mitral leaflets within the atrial wall. Besides the severe mitral regurgitation, this paradoxical backwards movement of the valve causes an intraventricular unloading during systole reducing the apparent LVEF of 72% to an effective LVEF of only 51%. In addition, forward flow fraction is only 22% after accounting for the regurgitant volume, as well. This combined involvement of the mitral valve could explain the discrepancy between a low output state and an apparently hyperdynamic LV contraction. Due to its ability to precisely measure flows and volumes, CMR is particularly suited to detect this phenomenon and to quantify its impact on the LV pump function.
Resumo:
BACKGROUND: New generation transcatheter heart valves (THV) may improve clinical outcomes of transcatheter aortic valve implantation. METHODS AND RESULTS: In a nationwide, prospective, multicenter cohort study (Swiss Transcatheter Aortic Valve Implantation Registry, NCT01368250), outcomes of consecutive transfemoral transcatheter aortic valve implantation patients treated with the Sapien 3 THV (S3) versus the Sapien XT THV (XT) were investigated. An overall of 153 consecutive S3 patients were compared with 445 consecutive XT patients. Postprocedural mean transprosthetic gradient (6.5±3.0 versus 7.8±6.3 mm Hg, P=0.17) did not differ between S3 and XT patients, respectively. The rate of more than mild paravalvular regurgitation (1.3% versus 5.3%, P=0.04) and of vascular (5.3% versus 16.9%, P<0.01) complications were significantly lower in S3 patients. A higher rate of new permanent pacemaker implantations was observed in patients receiving the S3 valve (17.0% versus 11.0%, P=0.01). There were no significant differences for disabling stroke (S3 1.3% versus XT 3.1%, P=0.29) and all-cause mortality (S3 3.3% versus XT 4.5%, P=0.27). CONCLUSIONS: The use of the new generation S3 balloon-expandable THV reduced the risk of more than mild paravalvular regurgitation and vascular complications but was associated with an increased permanent pacemaker rate compared with the XT. Transcatheter aortic valve implantation using the newest generation balloon-expandable THV is associated with a low risk of stroke and favorable clinical outcomes. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT01368250.
Resumo:
Aortic root (AoR) components provide synchronous and precise 3D deformation of the aortic root during the cardiac cycle in order to ensure closure and opening of the three leaflets over a lifetime. Any deviation from the natural 3D morphology, such as with AoR annulus dilatation, enlarged sinuses and/or dilatation of the sinotubular junction, as in the case of ascending aortic dilatation, may result in disruption of the natural AoR function. Surgical treatment of AoR pathology has two modalities: the replacement of the aortic valve by artificial prosthesis or by preservation of the three leaflets and reconstruction of the aortic root components. Currently, there are two basic aortic root reconstruction procedures: aortic root sparing and aortic valve reimplantation techniques. Regardless of the technique used, the restoration of adequate cusp coaptation, is from a technical point of view, the most important element to consider. To achieve this, there are two requirements that need to be met: (i) the valve coaptation should be superior to the level of the aortic root base by at least 8 mm and (ii) the coaptation height per se has to be ≥5 mm. Successful restoration of the aortic root requires adequate technical skills, detailed knowledge of aortic root anatomy and topography, and also knowledge of the spatial pattern of AoR elements. Recently, there has been growing interest in aortic root reconstructive procedures as well their modifications. As such, the aim of this review is to analyse aortic root topography and 3D anatomy from a surgical point of view. The review also focuses on potential risk regions that one should be aware of before the surgical journey into the 'deep waters area' of the AoR begins.
Improving coronary artery bypass graft durability: use of the external saphenous vein graft support.
Resumo:
Coronary bypass grafting remains the best option for patients suffering from multivessel coronary artery disease, and the saphenous vein is used as an additional conduit for multiple complete revascularizations. However, the long-term vein graft durability is poor, with almost 75% of occluded grafts after 10 years. To improve the durability, the concept of an external supportive structure was successfully developed during the last years: the eSVS Mesh device (Kips Bay Medical) is an external support for vein graft made of weft-knitted nitinol wire into a tubular form with an approximate length of 24 cm and available in three diameters (3.5, 4.0 and 4.5 mm). The device is placed over the outer wall of the vein and carefully deployed to cover the full length of the graft. The mesh is flexible for full adaptability to the heart anatomy and is intended to prevent kinking and dilatation of the vein in addition to suppressing the intima hyperplasia induced by the systemic blood pressure. The device is designed to reduce the vein diameter of about 15-20% at most to prevent the vein radial expansion induced by the arterial blood pressure, and the intima hyperplasia leading to the graft failure. We describe the surgical technique for preparing the vein graft with the external saphenous vein graft support (eSVS Mesh) and we share our preliminary clinical results.
Resumo:
Cette étude consiste à comparer les coûts de deux procédures de dilatation artérielle coronaire (angioplastie par ballonet et angioplastie avec pose de stent) uniquement lors de la phase de cathérisation (et non pas de l'ensemble des coûts du séjour hospitalier). La première partie traite de l'importance de la maladie coronarienne, de ses traitements et des objectifs de l'étude. La deuxième partie explique les éléments et la méthode qui composent le calcul des coûts, illustre les résultats et compare les résultats des deux procédures. La troisième partie analyse les résultats en identifiant quels types de coûts sont à l'origine de la différence du coût total et en explicitant les limites et les compléments nécessaires à l'étude.
Resumo:
Introduction La stratégie de reperfusion coronarienne par voie percutanée (PCI: percutaneous coronary intervention) est considérée comme étant la méthode de choix dans la prise en charge urgente des STEMI(H). Actuellement, les deux accès artériels principaux pour les PCI sont l'artère fémorale et l'artère radiale. La voie radiale est préconisée en première intention par les guidelines actuelles car elle serait associée à moins de complications hémorragiques. Objectif L'objectif de cette étude était de comparer la voie d'abord radiale à la voie fémorale, chez les patients admis pour un STEMI, en analysant le succès de la procédure de revascularisation, l'évolution clinique et les complications. Méthode Il s'agit d'une étude observationnelle, comprenant 268 patients admis au CHUV entre le 1er janvier et le 31 décembre 2013, avec le diagnostic de STEMI. Le choix de la voie d'accès artériel (fémorale ou radiale) était laissé au cardiologue interventionnel, sans randomisation. Les patients ont été séparés en 2 groupes, selon la voie d'abord vasculaire choisie au début de la procédure de revascularisation (intention to treat). Les endpoints primaires étaient les saignements majeurs (≥ 3 selon BARC)(A), et le door to balloon time(B). Les endpoints secondaires étaient les MACE(C), les saignements mineurs(A), le taux succès des procédures(D), le temps de fluoroscopie, la quantité de produit de contraste, et le taux de crossover(E) Résultats 268 patients en STEMI ont été inclus dans cette étude, pour un geste de revascularisation en urgence. La moyenne d'âge était de 64.3 ans, avec 73.1% d'hommes. 3 cas de saignements majeurs(A) ont lieu avec la voie radiale (3.4%), et 10 avec la voie fémorale (5.6%), p=0.44. Le door to balloon time ne diffère pas de manière significative selon la voie d'accès employée : 42 min (34-57) pour le groupe radial, et 48 min (31-61) pour le groupe fémoral, p=0.09. Les taux de MACE étaient de 8.0% avec la voie radiale, et de 6.7% avec la voie fémorale, p=0.7. Le taux de crossover était de 4.5% avec la voie radiale, et 0.6% avec la voie fémorale, p=0.02. Le temps de fluoroscopie était de 7min 28sec (5min 9 sec - 12min 25) pour la voie fémorale, contre 12min 22sec (9min 30 sec - 16min 19sec) pour la voie radiale, p < 0.05. La quantité de produit de contraste nécessaire était de 120 ml (100-160) pour le groupe fémoral, et de 170 ml (140-210) pour le groupe radial, p < 0.05. Le taux de succès était comparable entres les 2 groupes : 97.7% pour le groupe radial et 96.0% pour le groupe fémoral, p=0.47. 5.7% des patients du groupe radial sont décédés, contre 5.7% du groupe fémoral, p=0.97. Conclusion Notre étude démontre que la prise en charge d'un STEMI par voie radiale est possible, puisqu'elle n'allonge pas le « door to balloon time », qu'elle n'augmente pas le taux de MACE ni les saignements majeurs, que soit au point de ponction ou non. Par contre la voie radiale augmente la quantité de produit de contraste nécessaire, et allonge le temps de fluoroscopie de manière non négligeable. De futures études permettront peut-être de mieux définir les groupes de patients qui pourraient bénéficier le plus d'une approche radiale.