142 resultados para Ten commandments (Motion picture : 1956)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intravoxel incoherent motion (IVIM) MRI is a method to extract microvascular blood flow information out of diffusion-weighted images acquired at multiple b-values. We hypothesized that IVIM can identify the muscles selectively involved in a specific task, by measuring changes in activity-induced local muscular perfusion after exercise. We tested this hypothesis using a widely used clinical maneuver, the lift-off test, which is known to assess specifically the subscapularis muscle functional integrity. Twelve shoulders from six healthy male volunteers were imaged at 3 T, at rest, as well as after a lift-off test hold against resistance for 30 s, 1 and 2 min respectively, in three independent sessions. IVIM parameters, consisting of perfusion fraction (f), diffusion coefficient (D), pseudo-diffusion coefficient D* and blood flow-related fD*, were estimated within outlined muscles of the rotator cuff and the deltoid bundles. The mean values at rest and after the lift-off tests were compared in each muscle using a one-way ANOVA. A statistically significant increase in fD* was measured in the subscapularis, after a lift-off test of any duration, as well as in D. A fD* increase was the most marked (30 s, +103%; 1 min, +130%; 2 min, +156%) and was gradual with the duration of the test (in 10(-3) mm(2) /s: rest, 1.41 ± 0.50; 30 s, 2.86 ± 1.17; 1 min, 3.23 ± 1.22; 2 min, 3.60 ± 1.21). A significant increase in fD* and D was also visible in the posterior bundle of the deltoid. No significant change was consistently visible in the other investigated muscles of the rotator cuff and the other bundles of the deltoid. In conclusion, IVIM fD* allows the demonstration of a task-related microvascular perfusion increase after a specific task and suggests a direct relationship between microvascular perfusion and the duration of the effort. It is a promising method to investigate non-invasively skeletal muscle physiology and clinical perfusion-related muscular disorders.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estimation of human oxygen uptake (V˙o2) during exercise is often used as an alternative when its direct measurement is not feasible. The American College of Sports Medicine (ACSM) suggests estimating human V˙o2 during exercise on a cycle ergometer through an equation that considers individual's body mass and external work rate, but not pedaling rate (PR). We hypothesized that including PR in the ACSM equation would improve its V˙o2 prediction accuracy. Ten healthy male participants' (age 19-48 years) were recruited and their steady-state V˙o2 was recorded on a cycle ergometer for 16 combinations of external work rates (0, 50, 100, and 150 W) and PR (50, 70, 90, and 110 revolutions per minute). V˙o2 was calculated by means of a new equation, and by the ACSM equation for comparison. Kinematic data were collected by means of an infrared 3-D motion analysis system in order to explore the mechanical determinants of V˙o2. Including PR in the ACSM equation improved the accuracy for prediction of sub-maximal V˙o2 during exercise (mean bias 1.9 vs. 3.3 mL O2 kg(-1) min(-1)) but it did not affect the accuracy for prediction of maximal V˙o2 (P > 0.05). Confirming the validity of this new equation, the results were replicated for data reported in the literature in 51 participants. We conclude that PR is an important determinant of human V˙o2 during cycling exercise, and it should be considered when predicting oxygen consumption.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The kinematics of the anatomical shoulder are analysed and modelled as a parallel mechanism similar to a Stewart platform. A new method is proposed to describe the shoulder kinematics with minimal coordinates and solve the indeterminacy. The minimal coordinates are defined from bony landmarks and the scapulothoracic kinematic constraints. Independent from one another, they uniquely characterise the shoulder motion. A humanoid mechanism is then proposed with identical kinematic properties. It is then shown how minimal coordinates can be obtained for this mechanism and how the coordinates simplify both the motion-planning task and trajectory-tracking control. Lastly, the coordinates are also shown to have an application in the field of biomechanics where they can be used to model the scapulohumeral rhythm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, we propose a method for prospective motion correction in MRI using a novel image navigator module, which is triggered by a free induction decay (FID) navigator. Only when motion occurs, the image navigator is run and new positional information is obtained through image registration. The image navigator was specifically designed to match the impact on the magnetization and the acoustic noise of the host sequence. This detection-correction scheme was implemented for an MP-RAGE sequence and 5 healthy volunteers were scanned at 3T while performing various head movements. The correction performance was demonstrated through automated brain segmentation and an image quality index whose results are sensitive to motion artifacts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: Compensation for respiratory motion is needed while administering radiotherapy (RT) to tumors that are moving with respiration to reduce the amount of irradiated normal tissues and potentially decrease radiation-induced collateral damages. The purpose of this study was to test a new ventilation system designed to induce apnea-like suppression of respiratory motion and allow long enough breath hold durations to deliver complex RT. MATERIAL AND METHODS: The High Frequency Percussive Ventilation system was initially tested in a series of 10 volunteers and found to be well tolerated, allowing a median breath hold duration of 11.6min (range 3.9-16.5min). An evaluation of this system was subsequently performed in 4 patients eligible for adjuvant breast 3D conformal RT, for lung stereotactic body RT (SBRT), lung volumetric modulated arc therapy (VMAT), and VMAT for palliative pleural metastases. RESULTS: When compared to free breathing (FB) and maximal inspiration (MI) gating, this Percussion Assisted RT (PART) offered favorable dose distribution profiles in 3 out of the 4 patients tested. PART was applied in these 3 patients with good tolerance, without breaks during the "beam on time period" throughout the overall courses of RT. The mean duration of the apnea-like breath hold that was necessary for delivering all the RT fractions was 7.61min (SD=2.3). CONCLUSIONS: This first clinical implementation of PART was found to be feasible, tolerable and offers new opportunities in the field of RT for suppressing respiratory motion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 10-year experience of our automated molecular diagnostic platform that carries out 91 different real-time PCR is described. Progresses and future perspectives in molecular diagnostic microbiology are reviewed: why automation is important; how our platform was implemented; how homemade PCRs were developed; the advantages/disadvantages of homemade PCRs, including the critical aspects of troubleshooting and the need to further reduce the turnaround time for specific samples, at least for defined clinical settings such as emergencies. The future of molecular diagnosis depends on automation, and in a novel perspective, it is time now to fully acknowledge the true contribution of molecular diagnostic and to reconsider the indication for PCR, by also using these tests as first-line assays.