218 resultados para Scanline sampling technique
Resumo:
OBJECTIVE: Accuracy studies of Patient Safety Indicators (PSIs) are critical but limited by the large samples required due to low occurrence of most events. We tested a sampling design based on test results (verification-biased sampling [VBS]) that minimizes the number of subjects to be verified. METHODS: We considered 3 real PSIs, whose rates were calculated using 3 years of discharge data from a university hospital and a hypothetical screen of very rare events. Sample size estimates, based on the expected sensitivity and precision, were compared across 4 study designs: random and VBS, with and without constraints on the size of the population to be screened. RESULTS: Over sensitivities ranging from 0.3 to 0.7 and PSI prevalence levels ranging from 0.02 to 0.2, the optimal VBS strategy makes it possible to reduce sample size by up to 60% in comparison with simple random sampling. For PSI prevalence levels below 1%, the minimal sample size required was still over 5000. CONCLUSIONS: Verification-biased sampling permits substantial savings in the required sample size for PSI validation studies. However, sample sizes still need to be very large for many of the rarer PSIs.
Resumo:
We describe an improved multiple-locus variable-number tandem-repeat (VNTR) analysis (MLVA) scheme for genotyping Staphylococcus aureus. We compare its performance to those of multilocus sequence typing (MLST) and spa typing in a survey of 309 strains. This collection includes 87 epidemic methicillin-resistant S. aureus (MRSA) strains of the Harmony collection, 75 clinical strains representing the major MLST clonal complexes (CCs) (50 methicillin-sensitive S. aureus [MSSA] and 25 MRSA), 135 nasal carriage strains (133 MSSA and 2 MRSA), and 13 published S. aureus genome sequences. The results show excellent concordance between the techniques' results and demonstrate that the discriminatory power of MLVA is higher than those of both MLST and spa typing. Two hundred forty-two genotypes are discriminated with 14 VNTR loci (diversity index, 0.9965; 95% confidence interval, 0.9947 to 0.9984). Using a cutoff value of 45%, 21 clusters are observed, corresponding to the CCs previously defined by MLST. The variability of the different tandem repeats allows epidemiological studies, as well as follow-up of the evolution of CCs and the identification of potential ancestors. The 14 loci can conveniently be analyzed in two steps, based upon a first-line simplified assay comprising a subset of 10 loci (panel 1) and a second subset of 4 loci (panel 2) that provides higher resolution when needed. In conclusion, the MLVA scheme proposed here, in combination with available on-line genotyping databases (including http://mlva.u-psud.fr/), multiplexing, and automatic sizing, can provide a basis for almost-real-time large-scale population monitoring of S. aureus.
MRI of coronary vessel walls using radial k-space sampling and steady-state free precession imaging.
Resumo:
OBJECTIVE: The objective of our study was to investigate the impact of radial k-space sampling and steady-state free precession (SSFP) imaging on image quality in MRI of coronary vessel walls. SUBJECTS AND METHODS: Eleven subjects were examined on a 1.5-T MR system using three high-resolution navigator-gated and cardiac-triggered 3D black blood sequences (cartesian gradient-echo [GRE], radial GRE, and radial SSFP) with identical spatial resolution (0.9 x 0.9 x 2.4 mm3). The signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel wall sharpness, and motion artifacts were analyzed. RESULTS: The mean SNR and CNR of the coronary vessel wall were improved using radial imaging and were best using radial k-space sampling combined with SSFP imaging. Vessel border definition was similar for all three sequences. Radial k-space sampling was found to be less sensitive to motion. Consistently good image quality was seen with the radial GRE sequence. CONCLUSION: Radial k-space sampling in MRI of coronary vessel walls resulted in fewer motion artifacts and improved SNR and CNR. The use of SSFP imaging, however, did not result in improved coronary vessel wall visualization.
Resumo:
Prior the middle of the 90', interviewing participants in protest events was quiet rare. INdividual SUrveys in RAllies (INSURA) did enter the social researcher's usual toolkit only in the following decade after Favre, Fillieule and Mayer (1997) conducted such a survey with as a primary ambition to build a solid methodological framework that could be subsequently applied by other researchers. After some years of intensive use of INSURA, one is entitled to wonder whether that technique has fulfilled social researchers' hopes or not. In that paper, results of a collective work on alter-global rallies in Evian and Saint- Denis are used to answer three interrelated questions. Firstly, some basic methodological questions about how to collect data on crowds are adressed. What are the specific constraints of interviewing people at the very moment they are "expressing" a political opinion? What specific constraints result from the morphology of the covered events, that is to say, how to build a valid sampling frame? The authors then turn to a more general point about the questions that can be solved, or not, using that technique. Secondly it is the strenghts and weaknesses of INSURA in exploring the transnational dimension of alter global protests that is adressed. The authors show that INSURA is certainly well suited to explore the demographics of alter-global events, as well as relational networks of individuals and multiple belongings. On the contrary, it is assumed that organization networks and movement's boundaries are far more difficult to explore through that method, a fact that seriously limits international cross comparisons of events and movements based on that tool.
Resumo:
Identifying the geographic distribution of populations is a basic, yet crucial step in many fundamental and applied ecological projects, as it provides key information on which many subsequent analyses depend. However, this task is often costly and time consuming, especially where rare species are concerned and where most sampling designs generally prove inefficient. At the same time, rare species are those for which distribution data are most needed for their conservation to be effective. To enhance fieldwork sampling, model-based sampling (MBS) uses predictions from species distribution models: when looking for the species in areas of high habitat suitability, chances should be higher to find them. We thoroughly tested the efficiency of MBS by conducting an important survey in the Swiss Alps, assessing the detection rate of three rare and five common plant species. For each species, habitat suitability maps were produced following an ensemble modeling framework combining two spatial resolutions and two modeling techniques. We tested the efficiency of MBS and the accuracy of our models by sampling 240 sites in the field (30 sitesx8 species). Across all species, the MBS approach proved to be effective. In particular, the MBS design strictly led to the discovery of six sites of presence of one rare plant, increasing chances to find this species from 0 to 50%. For common species, MBS doubled the new population discovery rates as compared to random sampling. Habitat suitability maps coming from the combination of four individual modeling methods predicted well the species' distribution and more accurately than the individual models. As a conclusion, using MBS for fieldwork could efficiently help in increasing our knowledge of rare species distribution. More generally, we recommend using habitat suitability models to support conservation plans.
Resumo:
BACKGROUND: Sclerotherapy of telangiectasias and reticular leg veins can be unpleasant and painful for some patients. OBJECTIVE: To determine pain level with two different sclerotherapy techniques in a prospective randomized trial. METHODS: Patients with symmetrical telangiectasias and reticular veins on both legs (C(1A) or (S)E(P)A(S)P(N1) were randomized to the standard (successive injections of chromated glycerin mixed with one-third lidocaine-epinephrine 1%) or two-step technique (first treating only reticular veins with a single injection at the base of each cluster of telangiectasias and then successively injecting all remaining telangiectasias a few minutes later. Pain was assessed using a 100-point visual analogue scale (0 = no pain, 100 = maximum pain). RESULTS: Data from 53 consecutive patients could be evaluated. The two-step technique was significantly less painful (28.2) than the standard technique (40.6, p < .001). CONCLUSION: The two-step technique with chromated glycerin mixed with one-third lidocaine-epinephrine 1% significantly reduces sclerotherapy pain. This may be a useful technique for patients who are particularly sensitive or afraid of sclerotherapy.
Resumo:
Multi-phase postmortem CT angiography (MPMCTA) is recognized as a valuable tool to explore the vascular system, with higher sensitivity than conventional autopsy. However, a limitation is the impossibility to diagnose pulmonary embolism (PE) due to post-mortem blood clots situated in pulmonary arteries. The purpose of this study was to explore an eventual possibility to distinguish between real PE and artefacts mimicking PE. Our study included 416 medico-legal cases. All of them underwent MPMCTA, conventional autopsy and histological examination. We selected cases presenting arterial luminal filling defects in the pulmonary arteries. Their radiological interpretation was confronted to the one of autopsy and histological examination. We also investigated an eventual correlation between artefacts in pulmonary arteries and those in other parts of the vascular system. In 123 cases, filling defects of pulmonary arteries were described during MPMCTA. In 57 cases, this was interpreted as artefact and in 4 cases as suspected PE. In 62 cases only a differential diagnosis was made. Autopsy and histology could clearly identify the artefacts as such. Only one case of real PE was radiologically misinterpreted as artefact. In 6 of the 62 cases with no interpretation a PE was diagnosed. In 3 out of 4 suspected cases, PE was confirmed. We found out that filling defects in pulmonary arteries are nearly always associated to other vascular artefacts. Therefore, we suggest following some rules for radiological interpretation in order to allow a reliable diagnosis of pulmonary embolism after MPMCTA.
Resumo:
BACKGROUND: Gastric banding still represents one of the most widely used bariatric procedures. It provides acceptable weight loss in many patients, but has frequent long-term complications. Because different types of bands may lead to different results, we designed a randomized study to compare the Lapband® with the SAGB®. We hereby report on the long-term results. METHODS: Between December 1998 and June 2002, 180 morbidly obese patients were randomized between Lapband® or SAGB®. Weight loss, long-term morbidity, and need for reoperation were evaluated. RESULTS: Long-term weight loss did not differ between the two bands. Patients who maintained their band had an acceptable long-term weight loss of between 50 and 60 % EBMIL. In both groups, about half the patients developed long-term complications, with about 50 % requiring major redo surgery. There was no difference in the overall rates of long-term complications or failures between the two groups, but patients who had a Lapband® were significantly more prone to develop band slippage/pouch dilatation (13.3 versus 0 %, p < 0,001). CONCLUSIONS: Although in the absence of complication, gastric banding leads to acceptable weight loss; the long-term complication and major reoperation rates are very high independently from the type of band used or on the operative technique. Gastric banding leads to relatively poor overall long-term results and therefore should not be considered the procedure of choice for the treatment of morbid obesity. Patients should be informed of the limited overall weight loss and the very high complication rates.
Resumo:
Ce travail de recherche a été réalisé dans le laboratoire de pharmacologie clinique, au Centre Hospitalier Universitaire Sainte-Justine, à Montréal. C'est une étude rétrospective basée sur le suivi thérapeutique du Tacrolimus prescrit chez les enfants après transplantation hépatique. Ce suivi est nécessaire car le Tacrolimus possède une importante variabilité pharmacocinétique inter et intra-individuelle ainsi qu'un index thérapeutique très étroit. Actuellement, l'individualisation des doses prescrites est basée sur la mesure de la concentration de base - du médicament dans le sang (C0), mais des études récentes montrent que cette mesure ne reflète pas précisément l'exposition du Tacrolimus dans l'organisme chez les enfants. Le meilleur reflet de cette exposition est la mesure de l'aire sous la courbe (AUC). Cependant, cette dernière implique la mesure de multiples concentrations tout au long de l'intervalle entre 2 doses de médicament (Tacrolimus: 12 heures) ce qui est long, cher et impraticable en ambulatoire. De nouvelles méthodes utilisant un nombre limité de prélèvements ont donc été développées pour prédire au mieux cette AUC. Ce sont les "Limited sampling strategies" ou LSS. La plupart de ces LSS pour le Tacrolimus ont été développées et validées chez des patients transplantés adultes et leur application directe chez les transplantés pédiatriques n'est pas possible en raison de différences importantes au niveau des paramètres pharmacocinétiques du médicament entre ces deux populations. Aussi, le but de ce travail était de développer et valider, pour la première fois, des LSS chez les enfants transplantés hépatiques. Pour cela, une analyse de 36 profils pharmacocinétiques de 28 patients transplantés hépatiques âgés de 0.4- 18.5 ans a été effectuée. Tous les profils ont été réalisés au Centre Hospitalier Universitaire Sainte-Justine entre janvier 2007 et janvier 2009. Les LSS comportant au maximum 4 mesures de concentration ont été développées en utilisant une analyse de régression multiple. Parmi tous les modèles obtenus, cinq ont été sélectionnés sur la base de critères précis puis validés selon la méthode décrite par Sheiner et Beal.¦Les résultats montrent que ces cinq modèles peuvent prédire l'AUC du Tacrolimus avec une précision cliniquement acceptable de ± 15% alors que la C0 présente la plus faible corrélation avec l'AUC.¦En conclusion, cette étude confirme que la C0 ne permet pas de prédire de manière efficace l'exposition du Tacrolimus dans l'organisme dans notre population de patients pédiatriques contrairement aux LSS analysées qui offrent une méthode pratique et fiable. Par ailleurs, en permettant d'obtenir une estimation précise et simplifiée de l'AUC complète du Tacrolimus chez les patients, ces LSS ouvrent la porte à de futures études prospectives visant à mieux définir l'AUC cible du médicament et à déterminer si le suivi basé sur la mesure de l'AUC est plus efficace et plus sûr que celui basé sur la mesure de la C0.
Resumo:
U-Pb dating of zircons by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is a widely used analytical technique in Earth Sciences. For U-Pb ages below 1 billion years (1 Ga), Pb-206/U-238 dates are usually used, showing the least bias by external parameters such as the presence of initial lead and its isotopic composition in the analysed mineral. Precision and accuracy of the Pb/U ratio are thus of highest importance in LA-ICPMS geochronology. We consider the evaluation of the statistical distribution of the sweep intensities based on goodness-of-fit tests in order to find a model probability distribution fitting the data to apply an appropriate formulation for the standard deviation. We then discuss three main methods to calculate the Pb/U intensity ratio and its uncertainty in the LA-ICPMS: (1) ratio-of-the-mean intensities method, (2) mean-of-the-intensity-ratios method and (3) intercept method. These methods apply different functions to the same raw intensity vs. time data to calculate the mean Pb/U intensity ratio. Thus, the calculated intensity ratio and its uncertainty depend on the method applied. We demonstrate that the accuracy and, conditionally, the precision of the ratio-of-the-mean intensities method are invariant to the intensity fluctuations and averaging related to the dwell time selection and off-line data transformation (averaging of several sweeps); we present a statistical approach how to calculate the uncertainty of this method for transient signals. We also show that the accuracy of methods (2) and (3) is influenced by the intensity fluctuations and averaging, and the extent of this influence can amount to tens of percentage points; we show that the uncertainty of these methods also depends on how the signal is averaged. Each of the above methods imposes requirements to the instrumentation. The ratio-of-the-mean intensities method is sufficiently accurate provided the laser induced fractionation between the beginning and the end of the signal is kept low and linear. We show, based on a comprehensive series of analyses with different ablation pit sizes, energy densities and repetition rates for a 193 nm ns-ablation system that such a fractionation behaviour requires using a low ablation speed (low energy density and low repetition rate). Overall, we conclude that the ratio-of-the-mean intensities method combined with low sampling rates is the most mathematically accurate among the existing data treatment methods for U-Pb zircon dating by sensitive sector field ICPMS.
Resumo:
Background and objective: Asthma is one of the most frequent chronic diseases affecting children and adolescents. Good compliance is indispensable for effective treatment since a suboptimal use of inhalation devices can result in decreased therapeutic efficacy and increased morbidity. The objective of this work was to evaluate the inhalation technique of paediatric patients visiting a specialized consultation clinic of a university hospital. Design: Observational prospective study during a 3-month period. Setting Specialized consultation clinic of a university hospital. Main outcome measures: This study involved 40 outpatient infants, children and adolescents visiting alone or with their parent(s). Patients' data (age, sex, weight, diagnostic, reason for consulting, previous consultations) and their medicines were compiled using an ad hoc form. Filmed sequences of the inhalation procedure used by each child were reviewed independently by members of an interdisciplinary team consisting in a physician, a pharmacist, a nurse and a physiotherapist. A score of 1 was assigned to each correct step in the procedure, and a score of 0 to an incorrect step. A perfect procedure implied 12 correct steps. Results: Thirty patients were treated with a metered-dose inhaler and an inhalation chamber (Babyhaler or AeroChamber Plus); ten other patients were treated with a dry powder inhaler (Diskus or Turbuhaler). The agreement between the members of the interdisciplinary team was considered satisfactory. Nine patients (22.5%) reached an average score lower than 7, 18 patients (45%) a score between 7 and 10 and 13 (32.5%) a score equal to or better than 10. No patient reached the maximum score of 12. Users of the metered-dose inhalers (average score = 9.2) showed a better technique than users of the dry powder inhalers (average score = 7.4). Disappointingly, the score was not improved during a second consultation or following regular consultations. Conclusions: Video recording is a simple method to evaluate the degree of mastery of an inhalation procedure in paediatric patients. The method allows a convenient and efficient identification of suboptimal procedure steps by the hospital staff, and opens the way to patient-specific teaching. In two-thirds of juvenile patients, their inhalation technique was suboptimal despite initial training. This study shows conclusively that the inhalation technique in paediatric patients must be monitored during each examination, and teaching measures taken to improve it when necessary.
Resumo:
Objectifs: Evaluer la technique de reconstruction itérative VEO en tomodensitométrie (TDM) du thorax chez l'enfant. Matériels et méthodes: Etude prospective, basée sur 20 patients (7-18 ans), suivis pour mucoviscidose et adressés pour TDM de suivi. Dix patients (groupe A) ont eu une acquisition basse-dose habituelle (BD). Dix patients (groupe B) ont eu une acquisition très-basse-dose (TBD) et ultra-basse-dose (UBD). Les acquisitions BD étaient reconstruites par rétroprojection filtrée (RPF), les acquisitions TBD et UBD étaient reconstruites par RPF et VEO. L'évaluation de VEO était basée sur la réduction de dose et la qualité des images (mesures de bruit et scores de visualisation des structures pulmonaires). Résultats: Une réduction de dose d'environ 50% était obtenue dans le groupe B. La réduction du bruit en VEO par rapport aux RPF était de 55% en TBD et de 75% en UBD. En VEO, une amélioration des scores de visualisation des structures pulmonaires était obtenue en TBD et UBD. Cependant, en VEO-UBD, la visualisation des structures distales demeuraient parfois insuffisante et celle des structures proximales était altérée par une modification de texture de l'image. Conclusion: Malgré une altération possible de la texture de l'image en UBD, la technique de reconstruction VEO est performante en réduction de dose et amélioration des images.
3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition.
Resumo:
Current 2D black blood coronary vessel wall imaging suffers from a relatively limited coverage of the coronary artery tree. Hence, a 3D approach facilitating more extensive coverage would be desirable. The straightforward combination of a 3D-acquisition technique together with a dual inversion prepulse can decrease the effectiveness of the black blood preparation. To minimize artifacts from insufficiently suppressed blood signal of the nearby blood pools, and to reduce residual respiratory motion artifacts from the chest wall, a novel local inversion technique was implemented. The combination of a nonselective inversion prepulse with a 2D selective local inversion prepulse allowed for suppression of unwanted signal outside a user-defined region of interest. Among 10 subjects evaluated using a 3D-spiral readout, the local inversion pulse effectively suppressed signal from ventricular blood, myocardium, and chest wall tissue in all cases. The coronary vessel wall could be visualized within the entire imaging volume.