200 resultados para Respiration calorimeter.
Resumo:
The new Swiss Chronic Obstructive Pulmonary Disease (COPD) Guidelines are based on a previous version, which was published 10 years ago. The Swiss Respiratory Society felt the need to update the previous document due to new knowledge and novel therapeutic developments about this prevalent and important disease. The recommendations and statements are based on the available literature, on other national guidelines and, in particular, on the GOLD (Global Initiative for Chronic Obstructive Lung Disease) report. Our aim is to advise pulmonary physicians, general practitioners and other health care workers on the early detection and diagnosis, prevention, best symptomatic control, and avoidance of COPD as well as its complications and deterioration.
Resumo:
Abstract : The occupational health risk involved with handling nanoparticles is the probability that a worker will experience an adverse health effect: this is calculated as a function of the worker's exposure relative to the potential biological hazard of the material. Addressing the risks of nanoparticles requires therefore knowledge on occupational exposure and the release of nanoparticles into the environment as well as toxicological data. However, information on exposure is currently not systematically collected; therefore this risk assessment lacks quantitative data. This thesis aimed at, first creating the fundamental data necessary for a quantitative assessment and, second, evaluating methods to measure the occupational nanoparticle exposure. The first goal was to determine what is being used where in Swiss industries. This was followed by an evaluation of the adequacy of existing measurement methods to assess workplace nanopaiticle exposure to complex size distributions and concentration gradients. The study was conceived as a series of methodological evaluations aimed at better understanding nanoparticle measurement devices and methods. lt focused on inhalation exposure to airborne particles, as respiration is considered to be the most important entrance pathway for nanoparticles in the body in terms of risk. The targeted survey (pilot study) was conducted as a feasibility study for a later nationwide survey on the handling of nanoparticles and the applications of specific protection means in industry. The study consisted of targeted phone interviews with health and safety officers of Swiss companies that were believed to use or produce nanoparticles. This was followed by a representative survey on the level of nanoparticle usage in Switzerland. lt was designed based on the results of the pilot study. The study was conducted among a representative selection of clients of the Swiss National Accident Insurance Fund (SUVA), covering about 85% of Swiss production companies. The third part of this thesis focused on the methods to measure nanoparticles. Several pre- studies were conducted studying the limits of commonly used measurement devices in the presence of nanoparticle agglomerates, This focus was chosen, because several discussions with users and producers of the measurement devices raised questions about their accuracy measuring nanoparticle agglomerates and because, at the same time, the two survey studies revealed that such powders are frequently used in industry. The first preparatory experiment focused on the accuracy of the scanning mobility particle sizer (SMPS), which showed an improbable size distribution when measuring powders of nanoparticle agglomerates. Furthermore, the thesis includes a series of smaller experiments that took a closer look at problems encountered with other measurement devices in the presence of nanoparticle agglomerates: condensation particle counters (CPC), portable aerosol spectrometer (PAS) a device to estimate the aerodynamic diameter, as well as diffusion size classifiers. Some initial feasibility tests for the efficiency of filter based sampling and subsequent counting of carbon nanotubes (CNT) were conducted last. The pilot study provided a detailed picture of the types and amounts of nanoparticles used and the knowledge of the health and safety experts in the companies. Considerable maximal quantities (> l'000 kg/year per company) of Ag, Al-Ox, Fe-Ox, SiO2, TiO2, and ZnO (mainly first generation particles) were declared by the contacted Swiss companies, The median quantity of handled nanoparticles, however, was 100 kg/year. The representative survey was conducted by contacting by post mail a representative selection of l '626 SUVA-clients (Swiss Accident Insurance Fund). It allowed estimation of the number of companies and workers dealing with nanoparticles in Switzerland. The extrapolation from the surveyed companies to all companies of the Swiss production sector suggested that l'309 workers (95%-confidence interval l'073 to l'545) of the Swiss production sector are potentially exposed to nanoparticles in 586 companies (145 to l'027). These numbers correspond to 0.08% (0.06% to 0.09%) of all workers and to 0.6% (0.2% to 1.1%) of companies in the Swiss production sector. To measure airborne concentrations of sub micrometre-sized particles, a few well known methods exist. However, it was unclear how well the different instruments perform in the presence of the often quite large agglomerates of nanostructured materials. The evaluation of devices and methods focused on nanoparticle agglomerate powders. lt allowed the identification of the following potential sources of inaccurate measurements at workplaces with considerable high concentrations of airborne agglomerates: - A standard SMPS showed bi-modal particle size distributions when measuring large nanoparticle agglomerates. - Differences in the range of a factor of a thousand were shown between diffusion size classifiers and CPC/SMPS. - The comparison between CPC/SMPS and portable aerosol Spectrometer (PAS) was much better, but depending on the concentration, size or type of the powders measured, the differences were still of a high order of magnitude - Specific difficulties and uncertainties in the assessment of workplaces were identified: the background particles can interact with particles created by a process, which make the handling of background concentration difficult. - Electric motors produce high numbers of nanoparticles and confound the measurement of the process-related exposure. Conclusion: The surveys showed that nanoparticles applications exist in many industrial sectors in Switzerland and that some companies already use high quantities of them. The representative survey demonstrated a low prevalence of nanoparticle usage in most branches of the Swiss industry and led to the conclusion that the introduction of applications using nanoparticles (especially outside industrial chemistry) is only beginning. Even though the number of potentially exposed workers was reportedly rather small, it nevertheless underscores the need for exposure assessments. Understanding exposure and how to measure it correctly is very important because the potential health effects of nanornaterials are not yet fully understood. The evaluation showed that many devices and methods of measuring nanoparticles need to be validated for nanoparticles agglomerates before large exposure assessment studies can begin. Zusammenfassung : Das Gesundheitsrisiko von Nanopartikel am Arbeitsplatz ist die Wahrscheinlichkeit dass ein Arbeitnehmer einen möglichen Gesundheitsschaden erleidet wenn er diesem Stoff ausgesetzt ist: sie wird gewöhnlich als Produkt von Schaden mal Exposition gerechnet. Für eine gründliche Abklärung möglicher Risiken von Nanomaterialien müssen also auf der einen Seite Informationen über die Freisetzung von solchen Materialien in die Umwelt vorhanden sein und auf der anderen Seite solche über die Exposition von Arbeitnehmenden. Viele dieser Informationen werden heute noch nicht systematisch gesarnmelt und felilen daher für Risikoanalysen, Die Doktorarbeit hatte als Ziel, die Grundlagen zu schaffen für eine quantitative Schatzung der Exposition gegenüber Nanopartikel am Arbeitsplatz und die Methoden zu evaluieren die zur Messung einer solchen Exposition nötig sind. Die Studie sollte untersuchen, in welchem Ausmass Nanopartikel bereits in der Schweizer Industrie eingesetzt werden, wie viele Arbeitnehrner damit potentiel] in Kontakt komrrien ob die Messtechnologie für die nötigen Arbeitsplatzbelastungsmessungen bereits genügt, Die Studie folcussierte dabei auf Exposition gegenüber luftgetragenen Partikel, weil die Atmung als Haupteintrittspforte iïlr Partikel in den Körper angesehen wird. Die Doktorarbeit besteht baut auf drei Phasen auf eine qualitative Umfrage (Pilotstudie), eine repräsentative, schweizerische Umfrage und mehrere technische Stndien welche dem spezitischen Verständnis der Mëglichkeiten und Grenzen einzelner Messgeräte und - teclmikeri dienen. Die qualitative Telephonumfrage wurde durchgeführt als Vorstudie zu einer nationalen und repräsentativen Umfrage in der Schweizer Industrie. Sie zielte auf Informationen ab zum Vorkommen von Nanopartikeln, und den angewendeten Schutzmassnahmen. Die Studie bestand aus gezielten Telefoninterviews mit Arbeit- und Gesundheitsfachpersonen von Schweizer Unternehmen. Die Untemehmen wurden aufgrund von offentlich zugànglichen lnformationen ausgewählt die darauf hinwiesen, dass sie mit Nanopartikeln umgehen. Der zweite Teil der Dolctorarbeit war die repräsentative Studie zur Evalniernng der Verbreitnng von Nanopaitikelanwendungen in der Schweizer lndustrie. Die Studie baute auf lnformationen der Pilotstudie auf und wurde mit einer repräsentativen Selektion von Firmen der Schweizerischen Unfall Versicherungsanstalt (SUVA) durchgeüihxt. Die Mehrheit der Schweizerischen Unternehmen im lndustrieselctor wurde damit abgedeckt. Der dritte Teil der Doktorarbeit fokussierte auf die Methodik zur Messung von Nanopartikeln. Mehrere Vorstudien wurden dnrchgefîihrt, um die Grenzen von oft eingesetzten Nanopartikelmessgeräten auszuloten, wenn sie grösseren Mengen von Nanopartikel Agglomeraten ausgesetzt messen sollen. Dieser F okns wurde ans zwei Gründen gewählt: weil mehrere Dislcussionen rnit Anwendem und auch dem Produzent der Messgeràte dort eine Schwachstelle vermuten liessen, welche Zweifel an der Genauigkeit der Messgeräte aufkommen liessen und weil in den zwei Umfragestudien ein häufiges Vorkommen von solchen Nanopartikel-Agglomeraten aufgezeigt wurde. i Als erstes widmete sich eine Vorstndie der Genauigkeit des Scanning Mobility Particle Sizer (SMPS). Dieses Messgerät zeigte in Präsenz von Nanopartikel Agglorneraten unsinnige bimodale Partikelgrössenverteilung an. Eine Serie von kurzen Experimenten folgte, welche sich auf andere Messgeräte und deren Probleme beim Messen von Nanopartikel-Agglomeraten konzentrierten. Der Condensation Particle Counter (CPC), der portable aerosol spectrometer (PAS), ein Gerät zur Schàtzung des aerodynamischen Durchniessers von Teilchen, sowie der Diffusion Size Classifier wurden getestet. Einige erste Machbarkeitstests zur Ermittlnng der Effizienz von tilterbasierter Messung von luftgetragenen Carbon Nanotubes (CNT) wnrden als letztes durchgeiührt. Die Pilotstudie hat ein detailliiertes Bild der Typen und Mengen von genutzten Nanopartikel in Schweizer Unternehmen geliefert, und hat den Stand des Wissens der interviewten Gesundheitsschntz und Sicherheitsfachleute aufgezeigt. Folgende Typen von Nanopaitikeln wurden von den kontaktierten Firmen als Maximalmengen angegeben (> 1'000 kg pro Jahr / Unternehrnen): Ag, Al-Ox, Fe-Ox, SiO2, TiO2, und ZnO (hauptsächlich Nanopartikel der ersten Generation). Die Quantitäten von eingesetzten Nanopartikeln waren stark verschieden mit einem ein Median von 100 kg pro Jahr. ln der quantitativen Fragebogenstudie wurden l'626 Unternehmen brieflich kontaktiert; allesamt Klienten der Schweizerischen Unfallversicherringsanstalt (SUVA). Die Resultate der Umfrage erlaubten eine Abschätzung der Anzahl von Unternehmen und Arbeiter, welche Nanopartikel in der Schweiz anwenden. Die Hochrechnung auf den Schweizer lndnstriesektor hat folgendes Bild ergeben: ln 586 Unternehmen (95% Vertrauensintervallz 145 bis 1'027 Unternehmen) sind 1'309 Arbeiter potentiell gegenüber Nanopartikel exponiert (95%-Vl: l'073 bis l'545). Diese Zahlen stehen für 0.6% der Schweizer Unternehmen (95%-Vl: 0.2% bis 1.1%) und 0.08% der Arbeiternehmerschaft (95%-V1: 0.06% bis 0.09%). Es gibt einige gut etablierte Technologien um die Luftkonzentration von Submikrometerpartikel zu messen. Es besteht jedoch Zweifel daran, inwiefern sich diese Technologien auch für die Messurrg von künstlich hergestellten Nanopartikeln verwenden lassen. Aus diesem Grund folcussierten die vorbereitenden Studien für die Arbeitsplatzbeurteilnngen auf die Messung von Pulverri, welche Nan0partike1-Agg10merate enthalten. Sie erlaubten die ldentifikation folgender rnöglicher Quellen von fehlerhaften Messungen an Arbeitsplätzen mit erhöhter Luft-K0nzentrati0n von Nanopartikel Agglomeratenz - Ein Standard SMPS zeigte eine unglaubwürdige bimodale Partikelgrössenverteilung wenn er grössere Nan0par'til<e1Agg10merate gemessen hat. - Grosse Unterschiede im Bereich von Faktor tausend wurden festgestellt zwischen einem Diffusion Size Classiîier und einigen CPC (beziehungsweise dem SMPS). - Die Unterschiede zwischen CPC/SMPS und dem PAS waren geringer, aber abhängig von Grosse oder Typ des gemessenen Pulvers waren sie dennoch in der Grössenordnung von einer guten Grössenordnung. - Spezifische Schwierigkeiten und Unsicherheiten im Bereich von Arbeitsplatzmessungen wurden identitiziert: Hintergrundpartikel können mit Partikeln interagieren die während einem Arbeitsprozess freigesetzt werden. Solche Interaktionen erschweren eine korrekte Einbettung der Hintergrunds-Partikel-Konzentration in die Messdaten. - Elektromotoren produzieren grosse Mengen von Nanopartikeln und können so die Messung der prozessbezogenen Exposition stören. Fazit: Die Umfragen zeigten, dass Nanopartikel bereits Realitàt sind in der Schweizer Industrie und dass einige Unternehmen bereits grosse Mengen davon einsetzen. Die repräsentative Umfrage hat diese explosive Nachricht jedoch etwas moderiert, indem sie aufgezeigt hat, dass die Zahl der Unternehmen in der gesamtschweizerischen Industrie relativ gering ist. In den meisten Branchen (vor allem ausserhalb der Chemischen Industrie) wurden wenig oder keine Anwendungen gefunden, was schliessen last, dass die Einführung dieser neuen Technologie erst am Anfang einer Entwicklung steht. Auch wenn die Zahl der potentiell exponierten Arbeiter immer noch relativ gering ist, so unterstreicht die Studie dennoch die Notwendigkeit von Expositionsmessungen an diesen Arbeitsplätzen. Kenntnisse um die Exposition und das Wissen, wie solche Exposition korrekt zu messen, sind sehr wichtig, vor allem weil die möglichen Auswirkungen auf die Gesundheit noch nicht völlig verstanden sind. Die Evaluation einiger Geräte und Methoden zeigte jedoch, dass hier noch Nachholbedarf herrscht. Bevor grössere Mess-Studien durgefîihrt werden können, müssen die Geräte und Methodem für den Einsatz mit Nanopartikel-Agglomeraten validiert werden.
Resumo:
Oxygen consumption of collagenase-liberated rat adipocytes was measured by two different techniques: a microspectrophotometric method using hemoglobin as indicator of respiration and a technique using the oxygen electrode. These two completely different techniques gave similar values for oxygen consumption. With the spectrophotometric method, the oxygen consumption of single fat cells was determined. A close positive correlation (r = greater than 0.90) between oxygen consumption and fat cell size was observed in each tissue examined. With the oxygen electrode technique, oxygen consumption of adipocyte suspensions from young (40 days, 180 g) and old (90 days, 480 g) rats was examined. Fat cells of the suspensions were separated into classes of different size by a flotation technique. A significant positive correlation between fat cell size and oxygen consumption was observed in both young (r = 0.88) and old (r = 0.95) rats. However, the slope was much steeper in young rats. At a cell weight of 0.1 microgram the oxygen consumption was 0.364 and 0.086 microL O2/10(6) cells/min-1 in young and old rats, respectively. In the literature, a number of separate metabolic pathways have been found to be related positively to fat cell size and negatively to age. We conclude that these scattered metabolic observations are in agreement with integrated data on energy expenditure as evaluated from oxygen consumption. Estimations of the energy expenditure of adipose tissue indicates that this tissue is responsible for about 1% and 0.5% of the total energy expenditure in young and old rats, respectively.
Resumo:
OBJECTIVE: To compare the management of invasive candidiasis between infectious disease and critical care specialists. DESIGN AND SETTING: Clinical case scenarios of invasive candidiasis were presented during interactive sessions at national specialty meetings. Participants responded to questions using an anonymous electronic voting system. PATIENTS AND PARTICIPANTS: Sixty-five infectious disease and 51 critical care physicians in Switzerland. RESULTS: Critical care specialists were more likely to ask advice from a colleague with expertise in the field of fungal infections to treat Candida glabrata (19.5% vs. 3.5%) and C. krusei (36.4% vs. 3.3%) candidemia. Most participants reported that they would change or remove a central venous catheter in the presence of candidemia, but 77.1% of critical care specialists would start concomitant antifungal treatment, compared to only 50% of infectious disease specialists. Similarly, more critical care specialists would start antifungal prophylaxis when Candida spp. are isolated from the peritoneal fluid at time of surgery for peritonitis resulting from bowel perforation (22.2% vs. 7.2%). The two groups equally considered Candida spp. as pathogens in tertiary peritonitis, but critical care specialists would more frequently use amphotericin B than fluconazole, caspofungin, or voriconazole. In mechanically ventilated patients the isolation of 10(4) Candida spp. from a bronchoalveolar lavage was considered a colonizing organism by 94.9% of infectious disease, compared to 46.8% of critical care specialists, with a marked difference in the use of antifungal agents (5.1% vs. 51%). CONCLUSIONS: These data highlight differences between management approaches for candidiasis in two groups of specialists, particularly in the reported use of antifungals.
The cyclophilin inhibitor alisporivir prevents hepatitis C virus-mediated mitochondrial dysfunction.
Resumo:
Alisporivir (Debio-025) is an analogue of cyclosporine A and represents the prototype of a new class of non-immunosuppressive cyclophilin inhibitors. In vitro and in vivo studies have shown that alisporivir inhibits hepatitis C virus (HCV) replication, and ongoing clinical trials are exploring its therapeutic potential in patients with chronic hepatitis C. Recent data suggest that the antiviral effect is mediated by inhibition of cyclophilin A, which is an essential host factor in the HCV life cycle. However, alisporivir also inhibits mitochondrial permeability transition by binding to cyclophilin D. Because HCV is known to affect mitochondrial function, we explored the effect of alisporivir on HCV protein-mediated mitochondrial dysfunction. Through the use of inducible cell lines, which allow to investigate the effects of HCV polyprotein expression independent from viral RNA replication and which recapitulate the major alterations of mitochondrial bioenergetics observed in infectious cell systems, we show that alisporivir prevents HCV protein-mediated decrease of cell respiration, collapse of mitochondrial membrane potential, overproduction of reactive oxygen species and mitochondrial calcium overload. Strikingly, some of the HCV-mediated mitochondrial dysfunctions could even be rescued by alisporivir. Conclusion: These observations provide new insights into the pathogenesis of HCV-related liver disease and reveal an additional mechanism of action of alisporivir that is likely beneficial in the treatment of chronic hepatitis C. (HEPATOLOGY 2012).
Resumo:
Treatment of congenital diaphragmatic hernia (CDH) challenges obstetricians, pediatric surgeons, and neonatologists. Persistent pulmonary hypertension (PPHT) associated with lung hypoplasia in CDH leads to a high mortality rate at birth. PPHT is principally due to an increased muscularization of the arterioles. Management of CDH has been greatly improved by the introduction of prenatal surgical intervention with tracheal obstruction (TO) and by more appropriate postnatal care. TO appears to accelerate fetal lung growth and to increase the number of capillary vessels and alveoli. Improvement of postnatal care over the last years is mainly due to the avoidance of lung injury by applying low peak inflation pressure during ventilation. The benefits of other drugs or technical improvements such as the use of inhaled nitric oxide or extracorporeal membrane oxygenation (ECMO) are still being debated and no single strategy is accepted worldwide. Despite intensive clinical and experimental research, the treatment of newborn with CDH remains difficult.
Resumo:
Endogenous nitric oxide (NO) mediates pulmonary vasodilatation at birth, but inhaled NO fails to reduce pulmonary vascular resistance (PVR) in newborns with congenital diaphragmatic hernia (CDH). This study was designed to investigate the effects of ventilation, and the nature of its endogenous mediator, in fetal lambs with experimental CDH. Investigations at 138 days of gestation showed that ventilation markedly decreased PVR. Inhibition of NO synthesis reduced ventilation-induced pulmonary vasodilatation in vivo and increased in vitro isometric tension of vascular rings. Ventilation therefore reduces PVR at birth in lambs with CDH, and endogenous NO seems to contribute to this reduction.
Resumo:
BACKGROUND: We reviewed the current evidence on the benefit and harm of pre-hospital tracheal intubation and mechanical ventilation after traumatic brain injury (TBI). METHODS: We conducted a systematic literature search up to December 2007 without language restriction to identify interventional and observational studies comparing pre-hospital intubation with other airway management (e.g. bag-valve-mask or oxygen administration) in patients with TBI. Information on study design, population, interventions, and outcomes was abstracted by two investigators and cross-checked by two others. Seventeen studies were included with data for 15,335 patients collected from 1985 to 2004. There were 12 retrospective analyses of trauma registries or hospital databases, three cohort studies, one case-control study, and one controlled trial. Using Brain Trauma Foundation classification of evidence, there were 14 class 3 studies, three class 2 studies, and no class 1 study. Six studies were of adults, five of children, and three of both; age groups were unclear in three studies. Maximum follow-up was up to 6 months or hospital discharge. RESULTS: In 13 studies, the unadjusted odds ratios (ORs) for an effect of pre-hospital intubation on in-hospital mortality ranged from 0.17 (favouring control interventions) to 2.43 (favouring pre-hospital intubation); adjusted ORs ranged from 0.24 to 1.42. Estimates for functional outcomes after TBI were equivocal. Three studies indicated higher risk of pneumonia associated with pre-hospital (when compared with in-hospital) intubation. CONCLUSIONS: Overall, the available evidence did not support any benefit from pre-hospital intubation and mechanical ventilation after TBI. Additional arguments need to be taken into account, including medical and procedural aspects.
Resumo:
OBJECTIVE: Before a patient can be connected to a mechanical ventilator, the controls of the apparatus need to be set up appropriately. Today, this is done by the intensive care professional. With the advent of closed loop controlled mechanical ventilation, methods will be needed to select appropriate start up settings automatically. The objective of our study was to test such a computerized method which could eventually be used as a start-up procedure (first 5-10 minutes of ventilation) for closed-loop controlled ventilation. DESIGN: Prospective Study. SETTINGS: ICU's in two adult and one children's hospital. PATIENTS: 25 critically ill adult patients (age > or = 15 y) and 17 critically ill children selected at random were studied. INTERVENTIONS: To stimulate 'initial connection', the patients were disconnected from their ventilator and transiently connected to a modified Hamilton AMADEUS ventilator for maximally one minute. During that time they were ventilated with a fixed and standardized breath pattern (Test Breaths) based on pressure controlled synchronized intermittent mandatory ventilation (PCSIMV). MEASUREMENTS AND MAIN RESULTS: Measurements of airway flow, airway pressure and instantaneous CO2 concentration using a mainstream CO2 analyzer were made at the mouth during application of the Test-Breaths. Test-Breaths were analyzed in terms of tidal volume, expiratory time constant and series dead space. Using this data an initial ventilation pattern consisting of respiratory frequency and tidal volume was calculated. This ventilation pattern was compared to the one measured prior to the onset of the study using a two-tailed paired t-test. Additionally, it was compared to a conventional method for setting up ventilators. The computer-proposed ventilation pattern did not differ significantly from the actual pattern (p > 0.05), while the conventional method did. However the scatter was large and in 6 cases deviations in the minute ventilation of more than 50% were observed. CONCLUSIONS: The analysis of standardized Test Breaths allows automatic determination of an initial ventilation pattern for intubated ICU patients. While this pattern does not seem to be superior to the one chosen by the conventional method, it is derived fully automatically and without need for manual patient data entry such as weight or height. This makes the method potentially useful as a start up procedure for closed-loop controlled ventilation.
Resumo:
Free-living energy expenditure (EE) was assessed in 37 young pregnant Gambian women at the 12th (n = 11, 53.5 +/- 1.7 kg), 24th (n = 14, 54.7 +/- 2.1 kg), and 36th (n = 12, 65.0 +/- 2.6 kg) wk of pregnancy and was compared with nonpregnant nonlactating (NPNL) control women (n = 12, 50.3 +/- 1.6 kg). The following two methods were used to assess EE: 1) the heart rate (HR) method using individual regression lines (HR vs EE) established at different activity levels in a respiration chamber and 2) the doubly labeled water (2H2(18)O) method in a subgroup of 25 pregnant and 7 control women. With the HR method the EE during the agricultural rainy season was found to be 2,408 +/- 87, 2,293 +/- 122, and 2,782 +/- 130 kcal/day at 12, 24, and 36 wk of gestation and were not significantly different from the control group (2,502 +/- 133 kcal/day). These findings were confirmed by the 2H2(18)O measurements, which failed to show any effect of pregnancy on EE. Expressed per unit body weight, the free-living EE was found to be lower (P less than 0.01 with 2H2(18)O method) at 36 wk of gestation than in the NPNL group. It is concluded that, in these Gambian women, energy-sparing mechanisms that contribute to meet the additional energy stress of gestation are operating during pregnancy (e.g., diminished spontaneous physical activity).
Resumo:
The functional response of predators is usually modelled as a function of absolute prey density. Arditi and Ginzburg have suggested that it should often depend instead on the prey available per capita of predators, i.e. on the prey/predator ratio. Theory suggests that these two forms of dependence are related to the degree of spatial and temporal heterogeneity. Experiments using four filter-feeding cladoceran species were designed to test this hypothesis and to investigate the relation between individual behaviour and population dynamics. The patterns of population abundance that the cladocerans reached at equilibrium match the expectation that species with homogeneous spatial behaviour follow prey-dependent dynamics while those with heterogeneous behaviour follow ratio-dependent dynamics.
Resumo:
Summary Copper is an important trace element and micronutrient for living organisms as it is the cofactor of several enzymes involved in diverse biological redox processes such as aerobic respiration, denitrification and photosynthesis. Despite its importance, copper may be poorly bioavailable in soils and aquatic environments, as well as in the human body, especially at physiological or alkaline pH. In this work, we have investigated the strategies that the versatile bacterium and opportunistic pathogen Pseudomonas aeruginosa has evolved to face and overcome copper limitation. The global response of the P. aeruginosa to copper limitation was assessed under aerobic conditions. Numerous iron uptake functions (including the siderophores pyoverdine and pyochelin) were down-regulated whereas expression of cioAB (encoding an alternative, copper-independent, cyanide-resistant ubiquinol oxidase) was up-regulated. Wild type P. aeruginosa was able to grow aerobically in a defined glucose medium depleted of copper by a copper chelator, whereas a cioAB mutant did not grow. Thus, P. aeruginosa relies on the CioAB enzyme to cope with severe copper deprivation. A quadruple cyo cco1 cco2 cox mutant, which was deleted for all known heme-copper terminal oxidases of P. aeruginosa, grew aerobically, albeit more slowly than did the wild type, indicating that the CioAB enzyme is capable of energy conservation. However, the expression of a cioA'-'lacZ fusion was less dependent on the copper status in the quadruple mutant than in the wild type, suggesting that copper availability might affect cioAB expression indirectly, via the function of the heme-copper oxidases. These results suggest that the CioAB enzyme can be used as a by-pass strategy to overcome severe copper limitation and perform aerobic respiration even if virtually no copper is available. The PA0114 gene, which encodes a protein of the SCOT/SenC family, was found to be important for copper acquisition and aerobic respiration in low copper conditions. A PA0114 (sent) mutant grew poorly in low copper media and had low terminal oxidase activity with TMPD (N,N,N',N'-tetramethyl-p-phenylenediamine), but expressed the CioAB enzyme at elevated levels. Addition of copper reversed these phenotypes, suggesting that periplasmic copper capture by the SenC protein is another strategy that helps P. aeruginosa to adapt to copper deprivation. RESUME Le cuivre est un micronutriment important pour les organismes vivants. Il représente le cofacteur de plusieurs enzymes impliquées dans une multitude de processus biologiques tels que la respiration aérobie, la dénitrification et la photosynthèse. Malgré son importance, le cuivre peut être peu disponible dans les sols, les environnements aquatiques et le corps humain, spécialement à pH physiologique ou alcalin. Dans ce travail nous avons étudié les stratégies développées par la bactérie pathogène opportuniste Pseudomonas aeruginosa PAO1 afm de faire face et de surmonter le manque de cuivre. La réponse globale de P. aeruginosa à la carence de cuivre a été analysée dans des conditions aérobie. Les résultats obtenus ont montré que plusieurs gènes impliqués dans l'acquisition du fer, tels que les gènes codant pour les sidérophores (pyoverdine et pyochéline), étaient réprimés, tandis que l'expression de l'opéron cioAB, codant pour l'oxydase terminale insensible au cyanure (CIO), était augmentée. La souche sauvage P. aeruginosa est capable de croître dans un milieu où la concentration en cuivre est limitée, due à la présence d'un chélateur spéciftque de cuivre, tandis que le mutant cioAB ne croît pas dans ces conditions. Nous avons conclu que P. aeruginosa nécessite l'oxydase terminale CIO pour faire face à la carence en cuivre. Un quadruple mutant affecté dans toutes les oxydases dépendantes du cuivre (cyo ccol cco2 cox) et appartenant aux oxydases de type hème-cuivre, peut croître en aérobie, néanmoins plus lentement que la souche sauvage, ce qui montre que l'enzyme CIO est capable de conserver l'énergie. L'expression de la fusion rapportrice cioA'-'IacZ chez le quadruple mutant est moins dépendante de la disponibilité de cuivre que chez la souche sauvage. Ces résultats suggèrent que la disponibilité de cuivre influence l'expression de cioAB d'une façon indirecte, par le biais des oxydases terminales de type héme-cuivre. Il est donc possible qu'en cas de carence de cuivre, P. aeruginosa utilise l'enzyme CIO comme stratégie afin de surmonter ce manque et de réaliser la respiration aérobie. Nous avons démontré que le gène PA0114, codant pour une protéine appartenant à la famille SCO1/SenC, est important dans l'acquisition et dans la respiration aérobie dans des environnements où le cuivre est présent en faible concentration. En ces conditions, la croissance du mutant senC est faible; de plus, l'activité des oxydases terminales en présence du donneur d'électrons TMPD (N,N,N,N'-tetraméthyl-p-phénylenediamine) est basse. Toutefois, l'addition de cuivre au milieu de culture permet de restaurer le phénotype du type sauvage. Ces résultats montrent que la protéine SenC est capable d'acquérir le cuivre et représente donc une autre stratégie chez P. aeruginosa pour s'adapter à un manque de cuivre.