151 resultados para Radiation dose reduction


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Data suggest that esomeprazole decreases gastric secretion. AIMS: To assess the effect of a single i.v. esomeprazole dose on gastric secretion volume 3 h after drug administration, as a primary endpoint, and to evaluate, as secondary endpoints, the reduction 1 and 5 h after dosing; time when the gastric pH was <2.5 and esomeprazole's safety. METHODS: In all, 23 healthy Helicobacter pylori-negative volunteers (10 men, 13 women, mean age 28.2 +/- 6) participated in this single-centre, randomized, double-blind, placebo-controlled, 2-way, single-dose cross-over study. In different sessions, volunteers received i.v. either esomeprazole 40 mg or placebo. An inserted double-lumen nasogastric tube perfused and aspirated gastric liquid. Mechanical fractioned aspiration measured secretion volume; aliquot spectrophotometry assessed gastric secretion volume lost to the duodenum. RESULTS: Three hours post-i.v. esomeprazole, average gastric secretion decreased by 77.6% (vs. baseline) compared to placebo. Values 1 and 5 h after dosing were 73.5% and 74.5%. Five hours after esomeprazole, the gastric pH was <2.5 3.9% of the time and 73.3% after placebo (P < 0.002). Esomeprazole was well-tolerated. No serious adverse events occurred. CONCLUSIONS: Intravenous esomeprazole decreases gastric secretions. The potential clinical impact in averting bronchoaspiration during anaesthesia induction and in intensive care patients should be investigated in further studies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to investigate the radiation exposure of the Swiss population to interventional procedures. A nationwide survey was conducted in Switzerland. The annual effective dose per capita due to interventional procedures was found to be 0.14 mSv, corresponding to 12% of the total dose. Coronary angiography and percutaneous coronary interventions were found to be the most frequent and the most irradiating interventional procedures, accounting for 52% of the total examination frequency and 64% of the dose delivered to the population. Switzerland stands at the same level as other countries in terms of effective dose per capita due to interventional radiology.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Effective cancer treatment generally requires combination therapy. The combination of external beam therapy (XRT) with radiopharmaceutical therapy (RPT) requires accurate three-dimensional dose calculations to avoid toxicity and evaluate efficacy. We have developed and tested a treatment planning method, using the patient-specific three-dimensional dosimetry package 3D-RD, for sequentially combined RPT/XRT therapy designed to limit toxicity to organs at risk. METHODS AND MATERIALS: The biologic effective dose (BED) was used to translate voxelized RPT absorbed dose (D(RPT)) values into a normalized total dose (or equivalent 2-Gy-fraction XRT absorbed dose), NTD(RPT) map. The BED was calculated numerically using an algorithmic approach, which enabled a more accurate calculation of BED and NTD(RPT). A treatment plan from the combined Samarium-153 and external beam was designed that would deliver a tumoricidal dose while delivering no more than 50 Gy of NTD(sum) to the spinal cord of a patient with a paraspinal tumor. RESULTS: The average voxel NTD(RPT) to tumor from RPT was 22.6 Gy (range, 1-85 Gy); the maximum spinal cord voxel NTD(RPT) from RPT was 6.8 Gy. The combined therapy NTD(sum) to tumor was 71.5 Gy (range, 40-135 Gy) for a maximum voxel spinal cord NTD(sum) equal to the maximum tolerated dose of 50 Gy. CONCLUSIONS: A method that enables real-time treatment planning of combined RPT-XRT has been developed. By implementing a more generalized conversion between the dose values from the two modalities and an activity-based treatment of partial volume effects, the reliability of combination therapy treatment planning has been expanded.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: Diagnostic radiology involving ionizing radiation often leads to crucial information but also involves risk. Estimated cancer risks associated with CT range between 1 in 1000 to 1 in 10 000, depending on age and exposure settings. The aim of this contribution is to provide radiologists a way to inform a patient about these risks on a collective and individual base. Materials and methods: After a brief review of the effects of ionizing radiations, conversion from dose indicators into effective dose will be presented for radiography, fluoroscopy and CT. The Diagnostic Reference Level (DRL) concept will be then introduced to enable the reader to compare the level of exposure of various examinations. Finally, the limit of effective dose will be explained and risk projections after various radiological procedures for adults and children will be presented. Results: From an individual standpoint the benefit of a well justified and optimized CT examination clearly outweigh its risk of inducing a fatal cancer. The uncertainties associated with the effective dose concept should be kept in mind in order to avoid cancer risk projections after an examination on an individual basis. Conclusion: Risk factors or effective dose are not the simplest tools to communicate when dealing with radiological risks. Thus, a set of categories should be preferred as proposed in the ICRP (International Commission on Radiation Protection) report 99.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Excessive exposure to solar ultraviolet radiation is involved in the complex biologic process of cutaneous aging. Wavelengths in the ultraviolet-A and -B range (UV-A and UV-B) have been shown to be responsible for the induction of proteases, e. g. the collagenase matrix metalloproteinase 1 (MMP-1), which are related to cell aging. As devices emitting longer wavelengths are widely used in therapeutic and cosmetic interventions and as the induction of MMP-1 by water-filtered infrared-A (wIRA) had been discussed, it was of interest to assess effects of wIRA on the cellular and molecular level known to be possibly involved in cutaneous degeneration. OBJECTIVES: Investigation of the biological implications of widely used water-filtered infrared-A (wIRA) radiators for clinical use on human skin fibroblasts assessed by MMP-1 gene expression (MMP-1 messenger ribonucleic acid (mRNA) expression).Methods: Human skin fibroblasts were irradiated with approximately 88% wIRA (780-1400 nm) and 12% red light (RL, 665-780 nm) with 380 mW/cm(2) wIRA(+RL) (333 mW/cm(2) wIRA) on the one hand and for comparison with UV-A (330-400 nm, mainly UV-A1) and a small amount of blue light (BL, 400-450 nm) with 28 mW/cm(2) UV-A(+BL) on the other hand. Survival curves were established by colony forming ability after single exposures between 15 minutes and 8 hours to wIRA(+RL) (340-10880 J/cm(2) wIRA(+RL), 300-9600 J/cm(2) wIRA) or 15-45 minutes to UV-A(+BL) (25-75 J/cm(2) UV-A(+BL)). Both conventional Reverse Transcriptase Polymerase Chain Reaction (RT-PCR) and quantitative real-time RT-PCR techniques were used to determine the induction of MMP-1 mRNA at two physiologic temperatures for skin fibroblasts (30 degrees C and 37 degrees C) in single exposure regimens (15-60 minutes wIRA(+RL), 340-1360 J/cm(2) wIRA(+RL), 300-1200 J/cm(2) wIRA; 30 minutes UV-A(+BL), 50 J/cm(2) UV-A(+BL)) and in addition at 30 degrees C in a repeated exposure protocol (up to 10 times 15 minutes wIRA(+RL) with 340 J/cm(2) wIRA(+RL), 300 J/cm(2) wIRA at each time). RESULTS: Single exposure of cultured human dermal fibroblasts to UV-A(+BL) radiation yielded a very high increase in MMP-1 mRNA expression (11 +/-1 fold expression for RT-PCR and 76 +/-2 fold expression for real-time RT-PCR both at 30 degrees C, 75 +/-1 fold expression for real-time RT-PCR at 37 degrees C) and a dose-dependent decrease in cell survival. In contrast, wIRA(+RL) did not produce cell death and did not induce a systematic increase in MMP-1 mRNA expression (less than twofold expression, within the laboratory range of fluctuation) detectable with the sensitive methods applied. Additionally, repeated exposure of human skin fibroblasts to wIRA(+RL) did not induce MMP-1 mRNA expression systematically (less than twofold expression by up to 10 consecutive wIRA(+RL) exposures and analysis with real-time RT-PCR). CONCLUSIONS: wIRA(+RL) even at the investigated disproportionally high irradiances does not induce cell death or a systematic increase of MMP-1 mRNA expression, both of which can be easily induced by UV-A radiation. Furthermore, these results support previous findings of in vivo investigations on collagenase induction by UV-A but not wIRA and show that infrared-A with appropriate irradiances does not seem to be involved in MMP-1 mediated photoaging of the skin. As suggested by previously published studies wIRA could even be implicated in a protective manner.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite a low positive predictive value, diagnostic tests such as complete blood count (CBC) and C-reactive protein (CRP) are commonly used to evaluate whether infants with risk factors for early-onset neonatal sepsis (EOS) should be treated with antibiotics. We investigated the impact of implementing a protocol aiming at reducing the number of diagnostic tests in infants with risk factors for EOS in order to compare the diagnostic performance of repeated clinical examination with CBC and CRP measurement. The primary outcome was the time between birth and the first dose of antibiotics in infants treated for suspected EOS. Among the 11,503 infants born at ≥35 weeks during the study period, 222 were treated with antibiotics for suspected EOS. The proportion of infants receiving antibiotics for suspected EOS was 2.1% and 1.7% before and after the change of protocol (p = 0.09). Reduction of diagnostic tests was associated with earlier antibiotic treatment in infants treated for suspected EOS (hazard ratio 1.58; 95% confidence interval [CI] 1.20-2.07; p <0.001), and in infants with neonatal infection (hazard ratio 2.20; 95% CI 1.19-4.06; p = 0.01). There was no difference in the duration of hospital stay nor in the proportion of infants requiring respiratory or cardiovascular support before and after the change of protocol. Reduction of diagnostic tests such as CBC and CRP does not delay initiation of antibiotic treatment in infants with suspected EOS. The importance of clinical examination in infants with risk factors for EOS should be emphasised.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Exposure to solar ultraviolet (UV) radiation is the main causative factor for skin cancer. UV exposure depends on environmental and individual factors, but individual exposure data remain scarce. UV irradiance is monitored via different techniques including ground measurements and satellite observations. However it is difficult to translate such observations into human UV exposure or dose because of confounding factors (shape of the exposed surface, shading, behavior, etc.) A collaboration between public health institutions, a meteorological office and an institute specialized in computing techniques developed a model predicting the dose and distribution of UV exposure on the basis of ground irradiation and morphological data. Standard 3D computer graphics techniques were adapted to develop this tool, which estimates solar exposure of a virtual manikin depicted as a triangle mesh surface. The amount of solar energy received by various body locations is computed for direct, diffuse and reflected radiation separately. The radiation components are deduced from corresponding measurements of UV irradiance, and the related UV dose received by each triangle of the virtual manikin is computed accounting for shading by other body parts and eventual protection measures. The model was verified with dosimetric measurements (n=54) in field conditions using a foam manikin as surrogate for an exposed individual. Dosimetric results were compared to the model predictions. The model predicted exposure to solar UV adequately. The symmetric mean absolute percentage error was 13%. Half of the predictions were within 17% range of the measurements. This model allows assessing outdoor occupational and recreational UV exposures, without necessitating time-consuming individual dosimetry, with numerous potential uses in skin cancer prevention and research. Using this tool, we investigated solar UV exposure patterns with respect to the relative contribution of the direct, diffuse and reflected radiation. We assessed exposure doses for various body parts and exposure scenarios of a standing individual (static and dynamic postures). As input, the model used erythemally-weighted ground irradiance data measured in 2009 at Payerne, Switzerland. A year-round daily exposure (8 am to 5 pm) without protection was assumed. For most anatomical sites, mean daily doses were high (typically 6.2-14.6 SED) and exceeded recommended exposure values. Direct exposure was important during specific periods (e.g. midday during summer), but contributed moderately to the annual dose, ranging from 15 to 24% for vertical and horizontal body parts, respectively. Diffuse irradiation explained about 80% of the cumulative annual exposure dose. Acute diffuse exposures were also obtained for cloudy summer days. The importance of diffuse UV radiation should not be underestimated when advocating preventive measures. Messages focused on avoiding acute direct exposures may be of limited efficiency to prevent skin cancers associated with chronic exposure (e.g., squamous cell carcinomas).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A nationwide investigation was conducted in Switzerland to establish the exposure of the population by medical x rays and update the results of the 1998 survey. Both the frequency and the dose variations were studied in order to determine the change in the collective dose. The frequency study addressed 206 general practitioners (GPs), 30 hospitals, and 10 private radiology institutes. Except for the latter, the response rate was very satisfactory. The dose study relied on the assessment of the speed class of the screen-film combinations used by the GPs as well as the results of two separate studies dedicated to fluoroscopy and CT. The investigation showed that the total number of all medical x-ray examinations performed by GPs registered a 1% decrease between 1998 and 2003, and that the sensitivities of the film-screen combinations registered a shift towards higher values, leading to a reduction of the dose delivered by a GP of the order of 20%. The study indicated also that the total number of all x-ray examinations performed in hospitals increased by 4%, with a slight increase of radiographies by 1% but significant decrease of examinations involving fluoroscopy (39%), and a 70% increase for CT examinations. Concerning the doses, the investigation of a selection of examinations involving fluoroscopy showed a significant increase of the kerma-area product (KAP) per procedure. For CT the study showed an increase of the dose-length product (DLP) per procedure for skull and abdomen examinations, and a decrease for chest examination. Both changes in the frequency and the effective dose per examination led to a 20% increase in the total collective dose.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Summary Background  The dose-response between ultraviolet (UV) exposure patterns and skin cancer occurrence is not fully understood. Sun-protection messages often focus on acute exposure, implicitly assuming that direct UV radiation is the key contributor to the overall UV exposure. However, little is known about the relative contribution of the direct, diffuse and reflected radiation components. Objective  To investigate solar UV exposure patterns at different body sites with respect to the relative contribution of the direct, diffuse and reflected radiation. Methods  A three-dimensional numerical model was used to assess exposure doses for various body parts and exposure scenarios of a standing individual (static and dynamic postures). The model was fed with erythemally weighted ground irradiance data for the year 2009 in Payerne, Switzerland. A year-round daily exposure (08:00-17:00 h) without protection was assumed. Results  For most anatomical sites, mean daily doses were high (typically 6·2-14·6 standard erythemal doses) and exceeded the recommended exposure values. Direct exposure was important during specific periods (e.g. midday during summer), but contributed moderately to the annual dose, ranging from 15% to 24% for vertical and horizontal body parts, respectively. Diffuse irradiation explained about 80% of the cumulative annual exposure dose. Acute diffuse exposures were also observed during cloudy summer days. Conclusions  The importance of diffuse UV radiation should not be underestimated when advocating preventive measures. Messages focused on avoiding acute direct exposures may be of limited efficiency to prevent skin cancers associated with chronic exposure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The impact of curative radiotherapy depends mainly on the total dose delivered homogenously in the targeted volume. Nevertheless, the dose delivery is limited by the tolerated dose of the surrounding healthy tissues. Two different side effects (acute and late) can occur during and after radiotherapy. Of particular interest are the radiation-induced sequelae due to their irreversibility and the potential impact on daily quality of life. In a population treated in one center with the same technique, it appears that individual radiosensitivity clearly exists. In the hypothesis that genetic is involved in this area of research, lymphocytes seem to be the tissue of choice due to easy accessibility. Recently, low percentage of CD4 and CD8 lymphocyte apoptosis were shown to be correlated with high grade of sequelae. In addition, recent data suggest that patients with severe radiation-induced late side effects possess four or more SNP in candidate genes (ATM, SOD2, TGFB1, XRCC1 et XRCC3) and low radiation-induced CD8 lymphocyte apoptosis in vitro.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We compared the health-related quality-of-life of patients with newly diagnosed multiple myeloma aged over 65 years or transplant-ineligible in the pivotal, phase III FIRST trial. Patients received: i) continuous lenalidomide and low-dose dexamethasone until disease progression; ii) fixed cycles of lenalidomide and low-dose dexamethasone for 18 months; or iii) fixed cycles of melphalan, prednisone, thalidomide for 18 months. Data were collected using the validated questionnaires (QLQ-MY20, QLQ-C30, and EQ-5D). The analysis focused on the EQ-5D utility value and six domains pre-selected for their perceived clinical relevance. Lenalidomide and low-dose dexamethasone, and melphalan, prednisone, thalidomide improved patients' health-related quality-of-life from baseline over the duration of the study across all pre-selected domains of the QLQ-C30 and EQ-5D. In the QLQ-MY20, lenalidomide and low-dose dexamethasone demonstrated a significantly greater reduction in the Disease Symptoms domain compared with melphalan, prednisone, thalidomide at Month 3, and significantly lower scores for QLQ-MY20 Side Effects of Treatment at all post-baseline assessments except Month 18. Linear mixed-model repeated-measures analyses confirmed the results observed in the cross-sectional analysis. Continuous lenalidomide and low-dose dexamethasone delays disease progression versus melphalan, prednisone, thalidomide and has been associated with a clinically meaningful improvement in health-related quality-of-life. These results further establish continuous lenalidomide and low-dose dexamethasone as a new standard of care for initial therapy of myeloma by demonstrating superior health-related quality-of-life during treatment, compared with melphalan, prednisone, thalidomide.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In radionuclide metrology, Monte Carlo (MC) simulation is widely used to compute parameters associated with primary measurements or calibration factors. Although MC methods are used to estimate uncertainties, the uncertainty associated with radiation transport in MC calculations is usually difficult to estimate. Counting statistics is the most obvious component of MC uncertainty and has to be checked carefully, particularly when variance reduction is used. However, in most cases fluctuations associated with counting statistics can be reduced using sufficient computing power. Cross-section data have intrinsic uncertainties that induce correlations when apparently independent codes are compared. Their effect on the uncertainty of the estimated parameter is difficult to determine and varies widely from case to case. Finally, the most significant uncertainty component for radionuclide applications is usually that associated with the detector geometry. Recent 2D and 3D x-ray imaging tools may be utilized, but comparison with experimental data as well as adjustments of parameters are usually inevitable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A thorough literature review about the current situation on the implementation of eye lens monitoring has been performed in order to provide recommendations regarding dosemeter types, calibration procedures and practical aspects of eye lens monitoring for interventional radiology personnel. Most relevant data and recommendations from about 100 papers have been analysed and classified in the following topics: challenges of today in eye lens monitoring; conversion coefficients, phantoms and calibration procedures for eye lens dose evaluation; correction factors and dosemeters for eye lens dose measurements; dosemeter position and influence of protective devices. The major findings of the review can be summarised as follows: the recommended operational quantity for the eye lens monitoring is H p (3). At present, several dosemeters are available for eye lens monitoring and calibration procedures are being developed. However, in practice, very often, alternative methods are used to assess the dose to the eye lens. A summary of correction factors found in the literature for the assessment of the eye lens dose is provided. These factors can give an estimation of the eye lens dose when alternative methods, such as the use of a whole body dosemeter, are used. A wide range of values is found, thus indicating the large uncertainty associated with these simplified methods. Reduction factors from most common protective devices obtained experimentally and using Monte Carlo calculations are presented. The paper concludes that the use of a dosemeter placed at collar level outside the lead apron can provide a useful first estimate of the eye lens exposure. However, for workplaces with estimated annual equivalent dose to the eye lens close to the dose limit, specific eye lens monitoring should be performed. Finally, training of the involved medical staff on the risks of ionising radiation for the eye lens and on the correct use of protective systems is strongly recommended.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Pencil beam scanning and filter free techniques may involve dose-rates considerably higher than those used in conventional external-beam radiotherapy. Our purpose was to investigate normal tissue and tumour responses in vivo to short pulses of radiation. MATERIAL AND METHODS: C57BL/6J mice were exposed to bilateral thorax irradiation using pulsed (at least 40Gy/s, flash) or conventional dose-rate irradiation (0.03Gy/s or less) in single dose. Immunohistochemical and histological methods were used to compare early radio-induced apoptosis and the development of lung fibrosis in the two situations. The response of two human (HBCx-12A, HEp-2) tumour xenografts in nude mice and one syngeneic, orthotopic lung carcinoma in C57BL/6J mice (TC-1 Luc+), was monitored in both radiation modes. RESULTS: A 17Gy conventional irradiation induced pulmonary fibrosis and activation of the TGF-beta cascade in 100% of the animals 24-36 weeks post-treatment, as expected, whereas no animal developed complications below 23Gy flash irradiation, and a 30Gy flash irradiation was required to induce the same extent of fibrosis as 17Gy conventional irradiation. Cutaneous lesions were also reduced in severity. Flash irradiation protected vascular and bronchial smooth muscle cells as well as epithelial cells of bronchi against acute apoptosis as shown by analysis of caspase-3 activation and TUNEL staining. In contrast, the antitumour effectiveness of flash irradiation was maintained and not different from that of conventional irradiation. CONCLUSION: Flash irradiation shifted by a large factor the threshold dose required to initiate lung fibrosis without loss of the antitumour efficiency, suggesting that the method might be used to advantage to minimize the complications of radiotherapy.