237 resultados para Radiation Sensitivity


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whole-body counting is a technique of choice for assessing the intake of gamma-emitting radionuclides. An appropriate calibration is necessary, which is done either by experimental measurement or by Monte Carlo (MC) calculation. The aim of this work was to validate a MC model for calibrating whole-body counters (WBCs) by comparing the results of computations with measurements performed on an anthropomorphic phantom and to investigate the effect of a change in phantom's position on the WBC counting sensitivity. GEANT MC code was used for the calculations, and an IGOR phantom loaded with several types of radionuclides was used for the experimental measurements. The results show a reasonable agreement between measurements and MC computation. A 1-cm error in phantom positioning changes the activity estimation by >2%. Considering that a 5-cm deviation of the positioning of the phantom may occur in a realistic counting scenario, this implies that the uncertainty of the activity measured by a WBC is ∼10-20%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Exercise improves insulin resistance and is a first line for the prevention and treatment of type 2 diabetes. The extent, however, to which these responses are dose dependent is not known. The purpose of this study was to examine whether exercise dose was associated with improvements in insulin sensitivity after 4 months of exercise training in previously sedentary adults. METHODS: Fifty-five healthy volunteers participated in a 16-wk supervised endurance exercise intervention with a pre/postintervention design. Insulin sensitivity was assessed by euglycemic hyperinsulinemic clamp, peak oxygen uptake by a graded exercise test, and body composition by dual-energy x-ray absorptiometry. The exercise intervention consisted of three to five sessions per week with a minimum of three sessions supervised. A ramped exercise prescription protocol was used to achieve 75% of peak HR for 45 min per session. Exercise dose, expressed as average kilocalories expended per week, was computed as the product of exercise intensity, duration and frequency. RESULTS: Improved insulin sensitivity was significantly related to exercise dose in a graded dose-response relationship. No evidence of threshold or maximal dose-response effect was observed. Age and gender did not influence this dose-response relationship. Exercise intensity was also significantly related to improvements in insulin sensitivity, whereas frequency was not. CONCLUSIONS: This study identifies a graded dose-response relationship between exercise dose and improvements in insulin sensitivity. The implication of this observation is of importance for the adaptation of exercise prescription in clinical situations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Examination of the rate of grade III or grade IV radiation dermatitis during treatment of head and neck cancer (HNC) with radiotherapy (RT) and concurrent cetuximab in EORTC centres. MATERIALS AND METHOD: A questionnaire was sent to all members of the EORTC Radiation Oncology Group and Head and Neck Group (111 institutions) to evaluate the widespread use of cetuximab and radiotherapy in HNC and to estimate the frequency of grades III and IV skin reactions in the radiation portals associated with this protocol. Co-morbidities, RT schedules and co-medications were also recorded. RESULTS: We received responses from 28 institutions in 11 countries. A total of 125 HNC patients from 15 institutions were treated with cetuximab and concurrent RT. Information about the skin reactions was available from 71 patients. Of these 36 had no grade III/IV adverse effects in the RT field, 15 had a grade III and 20 had grade IV radiation dermatitis. No detectable relation of grades III and IV radiation dermatitis with co-morbidities such as liver insufficiency or renal dysfunction was found. CONCLUSION: According to the results of the questionnaire, grade III/IV radiation dermatitis is observed in 49% of HNC patients treated with cetuximab and concurrent RT. A systematic clinical monitoring of cutaneous side effects during RT plus cetuximab is advised to ensure the safety of this protocol.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Ocular anatomy and radiation-associated toxicities provide unique challenges for external beam radiation therapy. For treatment planning, precise modeling of organs at risk and tumor volume are crucial. Development of a precise eye model and automatic adaptation of this model to patients' anatomy remain problematic because of organ shape variability. This work introduces the application of a 3-dimensional (3D) statistical shape model as a novel method for precise eye modeling for external beam radiation therapy of intraocular tumors. METHODS AND MATERIALS: Manual and automatic segmentations were compared for 17 patients, based on head computed tomography (CT) volume scans. A 3D statistical shape model of the cornea, lens, and sclera as well as of the optic disc position was developed. Furthermore, an active shape model was built to enable automatic fitting of the eye model to CT slice stacks. Cross-validation was performed based on leave-one-out tests for all training shapes by measuring dice coefficients and mean segmentation errors between automatic segmentation and manual segmentation by an expert. RESULTS: Cross-validation revealed a dice similarity of 95% ± 2% for the sclera and cornea and 91% ± 2% for the lens. Overall, mean segmentation error was found to be 0.3 ± 0.1 mm. Average segmentation time was 14 ± 2 s on a standard personal computer. CONCLUSIONS: Our results show that the solution presented outperforms state-of-the-art methods in terms of accuracy, reliability, and robustness. Moreover, the eye model shape as well as its variability is learned from a training set rather than by making shape assumptions (eg, as with the spherical or elliptical model). Therefore, the model appears to be capable of modeling nonspherically and nonelliptically shaped eyes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Preclinical data indicate activity of mammalian target of rapamycin inhibitors and synergistic activity together with radiotherapy in glioblastoma. The aim of this trial is to assess the therapeutic activity of temsirolimus (CCI-779), an intravenous mTOR inhibitor, in patients with newly diagnosed glioblastoma with unmethylated O6 methlyguanine-DNA-methlytransferase (MGMT)promoter. Methods: Patients (n=257) with newly diagnosed glioblastoma after open surgical biopsy or resection fulfilling basic eligibility criteria underwent a central MGMT promoter analysis using quantitative methylation specific PCR. Patients with glioblastoma harboring an unmethylated MGMT promoter (n=111) were randomized 1:1 between radiotherapy (60 Gy; 5 times 2 Gy per week) plus concomitant and six cycles of maintenance temozolomide or radiotherapy plus weekly temsirolimus at 25 mg flat dose to be continued until progression or undue toxicity. Primary endpoint was overall survival at 12 months (OS12). Sample size of the investigational treatment arm required 54 patients to assess adequacy of temsirolimus activity set at 80%. More than 38 patients alive at 12 months in the per protocol population was considered a positive signal. A control arm of 54 patients treated with the standard of care was implemented to evaluate the assumptions on OS12. Results: Between December 2009 and October 2012, 111 pts in 14 centers were randomized and treated. Median age was 55 and 58 years in the temsirolimus and standard arm, respectively. Most patients (95.5%) had a WHO performance status of 0 or 1. Both therapies were properly administered with a median of 13 cycles of maintenance temsirolimus. In the per protocolpopulation, exactly 38 patients treated with temsirolimus (out of 54 eligible) reached OS12. In the intention to treat population OS12 was 72.2% [95% CI (58.2, 82.2)] in the temozolomide arm and 69.6% [95% CI (55.8, 79.9) in the temsirolimus arm [HR=1.16 95% CI (0.77, 1.76), p=0.47]. Conclusions: The therapeutic activity of temsirolimus in patients with newly diagnosed glioblastoma with an unmethylated MGMT promoter is too low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess how intrahepatic fat and insulin resistance relate to daily fructose and energy intake during short-term overfeeding in healthy subjects. DESIGN AND METHODS: The analysis of the data collected in several studies in which fasting hepatic glucose production (HGP), hepatic insulin sensitivity index (HISI), and intrahepatocellular lipids (IHCL) had been measured after both 6-7 days on a weight-maintenance diet (control, C; n = 55) and 6-7 days of overfeeding with 1.5 (F1.5, n = 7), 3 (F3, n = 17), or 4 g fructose/kg/day (F4, n = 10), with 3 g glucose/kg/day (G3, n = 11), or with 30% excess energy as saturated fat (fat30%, n = 10). RESULTS: F3, F4, G3, and fat30% all significantly increased IHCL, respectively by 113 ± 86, 102 ± 115, 59 ± 92, and 90 ± 74% as compared to C (all P < 0.05). F4 and G3 increased HGP by 16 ± 10 and 8 ± 11% (both P < 0.05), and F3 and F4 significantly decreased HISI by 20 ± 22 and 19 ± 14% (both P < 0.01). In contrast, there was no significant effect of fat30% on HGP or HISI. CONCLUSIONS: Short-term overfeeding with fructose or glucose decreases hepatic insulin sensitivity and increases hepatic fat content. This indicates short-term regulation of hepatic glucose metabolism by simple carbohydrates.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. To evaluate the impact of mobile devices and apps on the daily clinical activity of young radiation oncologists. Methods. A web-based questionnaire was sent to 382 young (≤40 years) members of the Italian Association of Radiation Oncology (AIRO). The 14 items investigated the diffusion of mobile devices (smartphones and/or tablets), their impact on daily clinical activity, and possible differences perceived by the participants over time. Results. A total of 158 questionnaires were available for statistical evaluation (response rate 41%). Up to 75% of respondents declared they used an electronic device during their clinical activity. Conversely, 82% considered the impact of smartphones/tables on daily practice low to moderate. Daily device use increased significantly from 2009 to 2012, with high daily use rates rising from 5% to 39.9%. Fulfillment of professional needs was declared by less than 42% of respondents and compliance with app indications by 32%. Almost all physicians desired in 2012 a comprehensive website concerning a variety of apps covering radiation oncologists' needs. Conclusions. Mobile devices are widely used by young Italian radiation oncologists in their daily clinical practice, while the indications so obtained are not always followed. Nevertheless, it would be important to verify the consistency of information found within apps, in order to avoid potential errors that might be detrimental to patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A nation-wide survey on radiation doses in diagnostic and interventional radiology was conducted in Switzerland in 1998 aiming at establishing their collective radiological impact on the Swiss population. The study consisted on the one hand of surveying the frequency of more than 250 types of examinations, covering conventional radiology, mammography, fluoroscopy, angiography, interventional radiology, CT, bone densitometry, conventional tomography and dental radiology. On the other hand, for each type of examination the associated patient dose was established by modeling. The results of this study show that about 9.5 million diagnostic and interventional examinations are performed annually in Switzerland (1.34 per caput) and that the associated annual collective dose is of the order of 7100 person.Sv (1.0 mSv per caput). Switzerland is similar to other European countries in terms of the frequency of examinations and the collective dose.