160 resultados para Power Doppler ultrasound
Resumo:
Introduction: Small for gestational age (SGA) is an important problem affecting 10% of pregnancies and is associated with significant perinatal morbidity. In about 80% of cases, a probable etiology or a major risk factor can be identified. But almost 20% of SGA cases are considered unexplained. The 60-kDa heat shock protein (HSP60) is a highly immunogenic protein whose synthesis is greatly upregulated under nonphysiological conditions. Bacterial and human HSP60 share a high degree of sequence homology, and immunity to conserved epitopes may result in development of autoimmunity following a bacterial infection. We hypothesized that unexplained SGA could be the consequence of immune sensitization to human HSP60. Methods: Unexplained SGA fetuses were identified by ultrasound biometry with normal Doppler velocimetry and with no detectable maternal or fetal abnormalities. Fetal sera were obtained by cordocentesis performed for a karyotype analysis in cases of unexplained SGA (study group) or for screening of Rhesus incompatibility (control group). Fetal sera were tested for HSP60 antigen and for IgG and IgM anti-HSP60 by ELISA as well as for other immune and hematological parameters. Results: Maternal parameters were similar between the 12 study cases and the 23 control cases. The mean gestational age at cordocentesis was 29 weeks. IgM anti-HSP60 was detected in 12 cases (100%) and in no controls (p < 0.00017), while IgG anti-HSP60 was detected in 7 cases (58%) and only 1 control (p < 0.001). Three of the 4 cases with the highest IgM antibody levels died. There were no differences in fetal serum levels of HSP60 antigen or other immune and hematological markers between the two groups. Conclusion: Fetuses with unexplained SGA are positive for IgM and IgG antibody to human HSP60 and the specific IgM antibody level is predictive of fetal mortality. Detection of these antibodies indicates that a placental perturbation and a fetal autoimmune reaction to HSP60 are associated with this developmental delay.
Resumo:
Five years of experience with endovascular infrarenal aneurysm repair at our institution is reviewed. Implantation of endoprostheses in 88 patients has been performed by surgeons using exclusively intravascular ultrasound (IVUS) and fluoroscopy. IVUS identified the target site of deployment in all cases. In-hospital morbidity was 22% (19/88). Two percent mortality (2/88) and 5% early conversion (4/88) as a consequence of type I endoleaks were noted only in the first 53 patients with early devices (NS). Early endoleaks were present in 36% (32/88) including twenty-two type I, five type II and five type III endoleaks. Proximal endoleaks were associated with early devices (P<0.001), and technical difficulties with deployment. Tube grafts used in the beginning, performed poorly with 54% (7/13) type I endoleaks. Endoleaks diminished to 10% (9/88) by spontaneous closure and secondary endovascular procedures that were necessary in 24% (21/88) and consisted of coil embolization/cuff extension (9), late conversion (6), and limb recanalization or femoral cross-over bypass (6). Endovascular aneurysm repair using IVUS is a valid alternative technique. Improved devices and systematic use of bifurcated endoprostheses for infrarenal aneurysms reduce the occurrence of type I endoleaks.
Resumo:
Ultrasound (US) has become a useful tool in the detection of early disease, differential diagnosis, guidance of treatment decisions and treatment monitoring of rheumatoid arthritis (RA). In 2008, the Swiss Sonography in Arthritis and Rheumatism (SONAR) group was established to promote the use of US in inflammatory arthritis in clinical practice. A scoring system was developed and taught to a large number of Swiss rheumatologists who already contributed to the Swiss Clinical Quality Management (SCQM) database, a national patient register. This paper intends to give a Swiss consensus about best clinical practice recommendations for the use of US in RA on the basis of the current literature knowledge and experience with the Swiss SONAR score. Literature research was performed to collect data on current evidence. The results were discussed among specialists of the Swiss university centres and private practice, following a structured procedure. Musculoskelatal US was found to be very helpful in establishing the diagnosis and monitoring the evolution of RA, and to be a reliable tool if used by experienced examiners. It influences treatment decisions such as continuing, intensifying or stepping down therapy. The definite modalities of integrating US into the diagnosis and monitoring of RA treatments will be defined within a few years. There are, however, strong arguments to use US findings as of today in daily clinical care. Some practical recommendations about the use of US in RA, focusing on the diagnosis and the use of the SONAR score, are proposed.
Resumo:
AIM: Chronic critical limb ischemia (CLI) often requires venous bypass grafting to distal arterial segments. However, graft patency is influenced by the length and quality of the graft and occasionally patients may have limited suitable veins. We investigated short distal bypass grafting from the superficial femoral or popliteal artery to the infrapopliteal, ankle or foot arteries, despite angiographic alterations of inflow vessels, providing that invasive pressure measurement at the site of the planned proximal anastomosis revealed an inflow-brachial pressure difference of <or=10 mmHg. METHODS: Four hundred and twenty-three consecutive infrainguinal bypass grafts were performed for CLI between June, 1999 and November, 2002 at our institution. All patients underwent preoperative clinical examination, arteriography and assessment of the veins by duplex ultrasound. The study group are patients in whom the proximal and distal anastomoses of the bypass are below the femoral bifurcation and the popliteal artery, respectively. Invasive arterial pressure measurements were recorded at the level of the planned proximal anastomosis which was performed at that level if the difference of the inflow-brachial pressure was <or=10 mmHg, irrespective of angiographic alterations of the inflow vessels proximal to the planned anastomosis. All patients had a clinical follow-up included a duplex examination of their graft, at 1 week, 3, 9 and 12 months and, thereafter, annually. No patient was lost to follow-up. RESULTS: Sixty-seven patients underwent 71 short distal bypass grafts in 71 limbs with reversed saphenous vein grafts in 52, in situ saphenous veins in 11, reversed cephalic vein in 1 and composite veins in 7, respectively. Surgical or endovascular interventions to improve inflow were required in 4 limbs (5.6%). The mean follow-up time was 22.5 months and the two-year survival was 92.5%. Primary and secondary patency rates at 2 years were 73% and 93%, respectively, and the limb salvage rate was 98.5%. CONCLUSION: In appropriately selected patients, short distal venous bypass grafts can be performed with satisfactory patency and limb salvage rates even in the presence of morphologic alterations of the inflow vessels providing that these are not hemodynamically significant, or can be corrected intraoperatively.
Resumo:
We characterize the value function of maximizing the total discounted utility of dividend payments for a compound Poisson insurance risk model when strictly positive transaction costs are included, leading to an impulse control problem. We illustrate that well known simple strategies can be optimal in the case of exponential claim amounts. Finally we develop a numerical procedure to deal with general claim amount distributions.
Resumo:
This study aimed to assess application of ultrasound (US) combined with microbubbles (MB) to transfect the ciliary muscle of rat eyes. Reporter DNA plasmids encoding for Gaussia luciferase, β-galactosidase or the green fluorescent protein (GFP), alone or mixed with 50% Artison MB, were injected into the ciliary muscle, with or without US exposure (US set at 1 MHz, 2 W/cm(2), 50% duty cycle for 2 min). Luciferase activity was measured in ocular fluids at 7 and 30 days after sonoporation. At 1 week, the US+MB treatment showed a significant increase in luminescence compared with control eyes, injected with plasmid only, with or without MB (×2.6), and, reporter proteins were localized in the ciliary muscle by histochemical analysis. At 1 month, a significant decrease in luciferase activity was observed in all groups. A rise in lens and ciliary muscle temperature was measured during the procedure but did not result in any observable or microscopic damages at 1 and 8 days. The feasibility to transfer gene into the ciliary muscle by US and MB suggests that sonoporation may allow intraocular production of proteins for the treatment of inflammatory, angiogenic and/or degenerative retinal diseases.
Resumo:
For radiotherapy treatment planning of retinoblastoma inchildhood, Computed Tomography (CT) represents thestandard method for tumor volume delineation, despitesome inherent limitations. CT scan is very useful inproviding information on physical density for dosecalculation and morphological volumetric information butpresents a low sensitivity in assessing the tumorviability. On the other hand, 3D ultrasound (US) allows ahigh accurate definition of the tumor volume thanks toits high spatial resolution but it is not currentlyintegrated in the treatment planning but used only fordiagnosis and follow-up. Our ultimate goal is anautomatic segmentation of gross tumor volume (GTV) in the3D US, the segmentation of the organs at risk (OAR) inthe CT and the registration of both. In this paper, wepresent some preliminary results in this direction. Wepresent 3D active contour-based segmentation of the eyeball and the lens in CT images; the presented approachincorporates the prior knowledge of the anatomy by usinga 3D geometrical eye model. The automated segmentationresults are validated by comparing with manualsegmentations. Then, for the fusion of 3D CT and USimages, we present two approaches: (i) landmark-basedtransformation, and (ii) object-based transformation thatmakes use of eye ball contour information on CT and USimages.
Resumo:
Introduction: A standardized three-dimensional ultrasonographic (3DUS) protocol is described that allows fetal face reconstruction. Ability to identify cleft lip with 3DUS using this protocol was assessed by operators with minimal 3DUS experience. Material and Methods: 260 stored volumes of fetal face were analyzed using a standardized protocol by operators with different levels of competence in 3DUS. The outcomes studied were: (1) the performance of post-processing 3D face volumes for the detection of facial clefts; (2) the ability of a resident with minimal 3DUS experience to reconstruct the acquired facial volumes, and (3) the time needed to reconstruct each plane to allow proper diagnosis of a cleft. Results: The three orthogonal planes of the fetal face (axial, sagittal and coronal) were adequately reconstructed with similar performance when acquired by a maternal-fetal medicine specialist or by residents with minimal experience (72 vs. 76%, p = 0.629). The learning curve for manipulation of 3DUS volumes of the fetal face corresponds to 30 cases and is independent of the operator's level of experience. Discussion: The learning curve for the standardized protocol we describe is short, even for inexperienced sonographers. This technique might decrease the length of anatomy ultrasounds and improve the ability to visualize fetal face anomalies.
Resumo:
Supplementation of elderly institutionalized women with vitamin D and calcium decreased hip fractures and increased hip bone mineral density. Quantitative ultrasound (QUS) measurements can be performed in nursing homes, and easily repeated for follow-up. However, the effect of the correction of vitamin D deficiency on QUS parameters is not known. Therefore, 248 institutionalized women aged 62-98 years were included in a 2-year open controlled study. They were randomized into a treated group (n = 124), receiving 440 IU of vitamin D3 combined with 500 mg calcium (1250 mg calcium carbonate, Novartis) twice daily, and a control group (n = 124). One hundred and three women (42%), aged 84.5 +/- 7.5 years, completed the study: 50 in the treated group, 53 in the controls. QUS of the calcaneus, which measures BUA (broadband ultrasound attenuation) and SOS (speed of sound), and biochemical analysis were performed before and after 1 and 2 years of treatment. Only the results of the women with a complete follow-up were taken into account. Both groups had low initial mean serum 25-hydroxyvitamin D levels (11.9 +/- 1.2 and 11.7 +/- 1.2 micrograms/l; normal range 6.4-40.2 micrograms/l) and normal mean serum parathyroid hormone (PTH) levels (43.1 +/- 3.2 and 44.6 +/- 3.5 ng/l; normal range 10-70 ng/l, normal mean 31.8 +/- 2.3 ng/l). The treatment led to a correction of the metabolic disturbances, with an increase in 25-hydroxyvitamin D by 123% (p < 0.01) and a decrease in PTH by 18% (p < 0.05) and of alkaline phosphatase by 15% (p < 0.01). In the controls there was a worsening of the hypovitaminosis D, with a decrease of 25-hydroxyvitamin D by 51% (p < 0.01) and an increase in PTH by 51% (p < 0.01), while the serum calcium level decreased by only 2% (p < 0.01). After 2 years of treatment BUA increased significantly by 1.6% in the treated group (p < 0.05), and decreased by 2.3% in the controls (p < 0.01). Therefore, the difference in BUA between the treated subjects and the controls (3.9%) was significant after 2 years (p < 0.01). However, SOS decreased by the same amount in both groups (approximately 0.5%). In conclusion, BUA, but not SOS, reflected the positive effect on bone of supplementation with calcium and vitamin D3 in a population of elderly institutionalized women.
Resumo:
INTRODUCTION: To compare the power spectral changes of the voluntary surface electromyogram (sEMG) and of the compound action potential (M wave) in the vastus medialis and vastus lateralis muscles during fatiguing contractions. METHODS: Interference sEMG and force were recorded during 48 intermittent 3-s isometric maximal voluntary contractions (MVC) from 13 young, healthy subjects. M waves and twitches were evoked using supramaximal femoral nerve stimulation between the successive MVCs. Mean frequency (F mean), and median frequency were calculated from the sEMG and M waves. Muscle fiber conduction velocity (MFCV) was computed by cross-correlation. RESULTS: The power spectral shift to lower frequencies was significantly greater for the voluntary sEMG than for the M waves (P < 0.05). Over the fatiguing protocol, the overall average decrease in MFCV (~25 %) was comparable to that of sEMG F mean (~22 %), but significantly greater than that of M-wave F mean (~9 %) (P < 0.001). The mean decline in MFCV was highly correlated with the mean decreases in both sEMG and M-wave F mean. CONCLUSIONS: The present findings indicated that, as fatigue progressed, central mechanisms could enhance the relative weight of the low-frequency components of the voluntary sEMG power spectrum, and/or the end-of-fiber (non-propagating) components could reduce the sensitivity of the M-wave spectrum to changes in conduction velocity.