196 resultados para Phasor measurement units.
Resumo:
Propane can be responsible for several types of lethal intoxication and explosions. Quantifying it would be very helpful to determine in some cases the cause of death. Some gas chromatography-mass spectrometry (GC-MS) methods of propane measurements do already exist. The main drawback of these GC-MS methods described in the literature is the absence of a specific propane internal standard necessary for accurate quantitative analysis. The main outcome of the following study was to provide an innovative Headspace-GC-MS method (HS-GC-MS) applicable to the routine determination of propane concentration in forensic toxicology laboratories. To date, no stable isotope of propane is commercially available. The development of an in situ generation of standards is thus presented. An internal-labeled standard gas (C3DH7) is generated in situ by the stoichiometric formation of propane by the reaction of deuterated water (D2O) with Grignard reagent propylmagnesium chloride (C3H7MgCl). The method aims to use this internal standard to quantify propane concentrations and, therefore, to obtain precise measurements. Consequently, a complete validation with an accuracy profile according to two different guidelines, the French Society of Pharmaceutical Sciences and Techniques (SFSTP) and the Gesellschaft für toxikologische und Forensische Chemie (GTFCh), is presented.
Resumo:
OBJECTIVES: The diagnosis of pheochromocytoma relies on the measurement of plasma free metanephrines assay whose reliability has been considerably improved by ultra-high pressure liquid chromatography tandem mass spectrometry (UHPLC-MS/MS). Here we report an analytical interference occurring between 4-hydroxy-3-methoxymethamphetamine (HMMA), a metabolite of 3,4-methylenedioxymethamphetamine (MDMA, "Ecstasy"), and normetanephrine (NMN) since they share a common pharmacophore resulting in the same product ion after fragmentation. DESIGN AND METHODS: Synthetic HMMA was spiked into plasma samples containing various concentrations of NMN and the intensity of the interference was determined by UPLC-MS/MS before and after improvement of the analytical method. RESULTS: Using a careful adjustment of chromatographic conditions including the change of the UPLC analytical column, we were able to distinguish both compounds. HMMA interference for NMN determination should be seriously considered since MDMA activates the sympathetic nervous system and if confounded with NMN may lead to false-positive tests when performing a differential diagnostic of pheochromocytoma.
Resumo:
Gait analysis methods to estimate spatiotemporal measures, based on two, three or four gyroscopes attached on lower limbs have been discussed in the literature. The most common approach to reduce the number of sensing units is to simplify the underlying biomechanical gait model. In this study, we propose a novel method based on prediction of movements of thighs from movements of shanks. Datasets from three previous studies were used. Data from the first study (ten healthy subjects and ten with Parkinson's disease) were used to develop and calibrate a system with only two gyroscopes attached on shanks. Data from two other studies (36 subjects with hip replacement, seven subjects with coxarthrosis, and eight control subjects) were used for comparison with the other methods and for assessment of error compared to a motion capture system. Results show that the error of estimation of stride length compared to motion capture with the system with four gyroscopes and our new method based on two gyroscopes was close ( -0.8 ±6.6 versus 3.8 ±6.6 cm). An alternative with three sensing units did not show better results (error: -0.2 ±8.4 cm). Finally, a fourth that also used two units but with a simpler gait model had the highest bias compared to the reference (error: -25.6 ±7.6 cm). We concluded that it is feasible to estimate movements of thighs from movements of shanks to reduce number of needed sensing units from 4 to 2 in context of ambulatory gait analysis.
Resumo:
PURPOSE: This descriptive article illustrates the application of Global Positioning System (GPS) professional receivers in the field of locomotion studies. The technological challenge was to assess the external mechanical work in outdoor walking. METHODS: Five subjects walked five times during 5 min on an athletic track at different imposed stride frequency (from 70-130 steps x min(-1)). A differential GPS system (carrier phase analysis) measured the variation of the position of the trunk at 5 Hz. A portable indirect calorimeter recorded breath-by-breath energy expenditure. RESULTS: For a walking speed of 1.05 +/- 0.11 m x s(-1), the vertical lift of the trunk (43 +/- 14 mm) induced a power of 46.0 +/- 20.4 W. The average speed variation per step (0.15 +/- 0.03 m x s(-1)) produced a kinetic power of 16.9 +/- 7.2 W. As compared with commonly admitted values, the energy exchange (recovery) between the two energy components was low (39.1 +/- 10.0%), which induced an overestimated mechanical power (38.9 +/- 18.3 W or 0.60 W x kg(-1) body mass) and a high net mechanical efficiency (26.9 +/- 5.8%). CONCLUSION: We assumed that the cause of the overestimation was an unwanted oscillation of the GPS antenna. It is concluded that GPS (in phase mode) is now able to record small body movements during human locomotion, and constitutes a promising tool for gait analysis of outdoor unrestrained walking. However, the design of the receiver and the antenna must be adapted to human experiments and a thorough validation study remains to be conducted.
Resumo:
Mast cells are well known for their role in hypersensitivity reactions. However, there is increasing evidence that they might also participate in both developing and weakening atherosclerotic plaques, potentially causing plaque instability. Some clinical studies have therefore postulated the existence of relationships between blood β-tryptase levels and acute coronary syndromes. In this study, we investigated postmortem serum β-tryptase levels in a series of 90 autopsy cases with various degrees of coronary atherosclerosis that had undergone medico-legal investigations. β-tryptase concentrations in these cases were compared to levels observed in 6 fatal anaphylaxis cases following contrast material administration. Postmortem serum β-tryptase concentrations in the anaphylactic deaths ranged from 146 to 979 ng/ml. In 9 out of 90 cases of cardiac deaths, β-tryptase levels were higher than clinical reference values of 11.4 ng/ml and ranged from 21 to 65 ng/ml. These results indicate that increased postmortem serum β-tryptase levels can be observed, though not systematically, in cardiac deaths with varying degrees of coronary atherosclerosis disease, thereby suggesting that mast cell activation in this disease cannot be ascertained by postmortem serum β-tryptase measurements.
The Europeanisation of the measurement of diversity in education: a soft instrument of public policy
Resumo:
Faced with an increasing number of data and rankings, the author questions the roles of the different groups of actors who were originally involved in questioning the use of statistical indicators as a means of addressing issues of access to higher education. The comparison and nature of these international (UNESCO, OECD, EUROSTAT) and national (Germany, England, France, Switzerland) indicators in matters of inequalities of access to higher education question the tension between the discourses and the indicators they generate, and their recording at the national level. Who says what and with what consequences? What range of actors are involved in this process? What kind of power relations forms them? The author discusses how the issue of inequalities of access to higher education got on to the agendas of European organisations, identifies the policies that were defined, and sets them against an array of indicators, showing the discrepancy between the discourses and what the indicators reveal, the gap between the recommendations and the available tools. Why is there such a contrast? What are the mechanisms at work? Is it a technical or a political problem? What does this discrepancy reveal as far as national specificities within the construction of social inequalities are concerned?
Resumo:
Because self-reported health status [SRHS] is an ordered response variable, inequality measurement for SRHS data requires a numerical scale for converting individual responses into a summary statistic. The choice of scale is however problematic, since small variations in the numerical scale may reverse the ordering of a given pair of distributions of SRHS data in relation to conventional inequality indices such as the variance. This paper introduces a parametric family of inequality indices, founded on an inequality ordering proposed by Allison and Foster [Allison, R.A., Foster, J., 2004. Measuring health inequalities using qualitative data. Journal of Health Economics 23, 505-524], which satisfy a suitable invariance property with respect to the choice of numerical scale. Several key members of the parametric family are also derived, and an empirical application using data from the Swiss Health Survey illustrates the proposed methodology. [Authors]
Resumo:
Computer-Aided Tomography Angiography (CTA) images are the standard for assessing Peripheral artery disease (PAD). This paper presents a Computer Aided Detection (CAD) and Computer Aided Measurement (CAM) system for PAD. The CAD stage detects the arterial network using a 3D region growing method and a fast 3D morphology operation. The CAM stage aims to accurately measure the artery diameters from the detected vessel centerline, compensating for the partial volume effect using Expectation Maximization (EM) and a Markov Random field (MRF). The system has been evaluated on phantom data and also applied to fifteen (15) CTA datasets, where the detection accuracy of stenosis was 88% and the measurement accuracy was with an 8% error.
Resumo:
In the realm of forensic pathology, β-tryptase measurement for diagnostic purposes is performed in postmortem serum obtained from femoral blood. This may be partially or completely unavailable in some specific cases, such as infant autopsies and severely damaged bodies. The aim of this study was to investigate the usefulness of determining β-tryptase levels for diagnostic purposes in alternative biological samples. Urine, vitreous humor and pericardial fluid were selected and measured in 94 subjects including: fatal anaphylaxis following contrast material administration (6 cases), hypothermia (10 cases), diabetic ketoacidosis (10 cases), gunshot suicide (10 cases), heroin injection-related deaths (18 cases), trauma (10 cases), sudden death with minimal coronary atherosclerosis (10 cases), severe coronary atherosclerosis without myocardial infarction (10 cases) and severe coronary atherosclerosis with myocardial infarction (10 cases). Postmortem serum and pericardial fluid β-tryptase levels higher than the clinical reference value (11.4ng/ml) were systematically identified in fatal anaphylaxis following contrast material administration and 6 cases unrelated to anaphylaxis. β-tryptase concentrations in urine and vitreous humor were lower than the clinical reference value in all cases included in this study. Determination of β-tryptase in pericardial fluid appears to be a possible alternative to postmortem serum in the early postmortem period when femoral blood cannot be collected during autopsy and biochemical investigations are required to objectify increased β-tryptase levels.
Resumo:
Major liver resection can be used in the treatment of liver cancer. The functional capacity of liver parenchyma needs to be evaluated preoperatively because it conditions the outcome. We assessed whether the whole body clearance of glycerol, a substrate essentially metabolized in liver cells, may be suitable as a simple test of liver function. Seven patients after major hepatectomy, six patients after colectomy and 12 healthy subjects were studied. Patients were investigated on the first day after surgery. All participants were studied during a 150-min basal period followed by a 120-min infusion of 16 mumol kg-1 min-1 13C-labelled glycerol. Whole body glycerol clearance was calculated from the change in plasma glycerol concentration. Whole body glucose production was measured with 6,6 2H2 glucose infused as a tracer in the basal state and during glycerol infusion. In addition, 13C glucose synthesis was monitored to quantitate gluconeogenesis from glycerol. Patients after liver resection had higher plasma glycerol concentrations and lower whole body glycerol clearance than healthy subjects and patients after colectomy. They also had higher plasma glucagon concentrations. Their fasting glucose production was mildly elevated in the fasting state and did not change after glycerol infusion, indicating a normal hepatic autoregulation of glucose production. These results indicate that whole body glycerol clearance can be simply determined from plasma glycerol concentrations during exogenous glycerol infusion. It is significantly reduced in patients after major hepatectomy, suggesting that it constitutes a sensitive test of hepatic function. Its use as a preoperative testing procedure remains to be evaluated.
Resumo:
OBJECTIVE: To assess the properties of various indicators aimed at monitoring the impact on the activity and patient outcome of a bed closure in a surgical intensive care unit (ICU). DESIGN: Comparison before and after the intervention. SETTING: A surgical ICU at a university hospital. PATIENTS: All patients admitted to the unit over two periods of 10 months. INTERVENTION: Closure of one bed out of 17. MEASUREMENTS AND RESULTS: Activity and outcome indicators in the ICU and the structures upstream from it (emergency department, operative theater, recovery room) and downstream from it (intermediate care units). After the bed closure, the monthly medians of admitted patients and ICU hospital days increased from 107 (interquartile range 94-112) to 113 (106-121, P=0.07) and from 360 (325-443) to 395 (345-436, P=0.48), respectively, along with the linear trend observed in our institution. All indicators of workload, patient severity, and outcome remained stable except for SAPS II score, emergency admissions, and ICU readmissions, which increased not only transiently but also on a mid-term basis (10 months), indicating that the process of patient care delivery was no longer predictable. CONCLUSIONS: Health care systems, including ICUs, are extraordinary flexible, and can adapt to multiple external constraints without altering commonly used activity and outcome indicators. It is therefore necessary to set up multiple indicators to be able to reliably monitor the impact of external interventions and intervene rapidly when the system is no longer under control.
Resumo:
The aim of this work is to study the influence of several analytical parameters on the variability of Raman spectra of paint samples. In the present study, microtome thin section and direct (no preparation) analysis are considered as sample preparation. In order to evaluate their influence on the measures, an experimental design such as 'fractional full factorial' with seven factors (including the sampling process) is applied, for a total of 32 experiments representing 160 measures. Once the influence of sample preparation highlighted, a depth profile of a paint sample is carried out by changing the focusing plane in order to measure the colored layer under a clearcoat. This is undertaken in order to avoid sample preparation such a microtome sectioning. Finally, chemometric treatments such as principal component analysis are applied to the resulting spectra. The findings of this study indicate the importance of sample preparation, or more specifically, the surface roughness, on the variability of the measurements on a same sample. Moreover, the depth profile experiment highlights the influence of the refractive index of the upper layer (clearcoat) when measuring through a transparent layer.
Resumo:
The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.