209 resultados para Motion (Right) - Quebec (Province)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a device made of artificial muscle for the treatment of end-stage heart failure as an alternative to current heart assist devices. The key component is a matrix of nitinol wires and aramidic fibers called Biometal muscle (BM). When heated electrically, it produces a motorless, smooth, and lifelike motion. The BM is connected to a carbon fiber scaffold, tightening the heart and providing simultaneous assistance to the left and right ventricles. A pacemaker-like microprocessor drives the contraction of the BM. We tested the device in a dedicated bench model of diseased heart. It generated a systolic pressure of 75 mm Hg and ejected a maximum of 330 ml/min, with an ejection fraction of 12%. The device required a power supply of 6 V, 250 mA. This could be the beginning of an era in which BMs integrate or replace the mechanical function of natural muscles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the feasibility of intravoxel incoherent motion (IVIM) perfusion measurements in the brain with currently available imaging systems. MATERIALS AND METHODS: We acquired high in-plane resolution (1.2 × 1.2 mm(2) ) diffusion-weighted images with 16 different values of b ranging from 0 to 900 s/mm(2) , in three orthogonal directions, on 3T systems with a 32-multichannel receiver head coil. IVIM perfusion maps were extracted by fitting a double exponential model of signal amplitude decay. Regions of interest were drawn in pathological and control regions, where IVIM perfusion parameters were compared to the corresponding dynamic susceptibility contrast (DSC) parameters. RESULTS: Hyperperfusion was found in the nonnecrotic or cystic part of two histologically proven glioblastoma multiforme and in two histologically proven glioma WHO grade III, as well as in a brain metastasis of lung adenocarcinoma, in a large meningioma, and in a case of ictal hyperperfusion. A monoexponential decay was found in a territory of acute ischemia, as well as in the necrotic part of a glioblastoma. The IVIM perfusion fraction f correlated well with DSC CBV. CONCLUSION: Our initial report suggests that high-resolution brain perfusion imaging is feasible with IVIM in the current clinical setting. J. Magn. Reson. Imaging 2014;39:624-632. © 2013 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Relaxation rates provide important information about tissue microstructure. Multi-parameter mapping (MPM) estimates multiple relaxation parameters from multi-echo FLASH acquisitions with different basic contrasts, i.e., proton density (PD), T1 or magnetization transfer (MT) weighting. Motion can particularly affect maps of the apparent transverse relaxation rate R2(*), which are derived from the signal of PD-weighted images acquired at different echo times. To address the motion artifacts, we introduce ESTATICS, which robustly estimates R2(*) from images even when acquired with different basic contrasts. ESTATICS extends the fitted signal model to account for inherent contrast differences in the PDw, T1w and MTw images. The fit was implemented as a conventional ordinary least squares optimization and as a robust fit with a small or large confidence interval. These three different implementations of ESTATICS were tested on data affected by severe motion artifacts and data with no prominent motion artifacts as determined by visual assessment or fast optical motion tracking. ESTATICS improved the quality of the R2(*) maps and reduced the coefficient of variation for both types of data-with average reductions of 30% when severe motion artifacts were present. ESTATICS can be applied to any protocol comprised of multiple 2D/3D multi-echo FLASH acquisitions as used in the general research and clinical setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peasant societies are often seen by neoliberal or Marxist theorists as passive subjects of political-economic transformations occurring at a higher level, only surviving through acculturation to market requirements. By analyzing agricultural work organization in highland communities and a local system of water management called Acuerdos Reciprocos por el Agua (Reciprocal Agreements for Water), developed in 2003 by the Natura Bolivia foundation in Florida Province in Bolivia, we show that, contrary to this perception, traditional reciprocal norms still play an essential role in decision making. This suggests the agency of rural societies and the resilience of traditional reciprocity-based norms in mountain regions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diffusion-weighting in magnetic resonance imaging (MRI) increases the sensitivity to molecular Brownian motion, providing insight in the micro-environment of the underlying tissue types and structures. At the same time, the diffusion weighting renders the scans sensitive to other motion, including bulk patient motion. Typically, several image volumes are needed to extract diffusion information, inducing also inter-volume motion susceptibility. Bulk motion is more likely during long acquisitions, as they appear in diffusion tensor, diffusion spectrum and q-ball imaging. Image registration methods are successfully used to correct for bulk motion in other MRI time series, but their performance in diffusion-weighted MRI is limited since diffusion weighting introduces strong signal and contrast changes between serial image volumes. In this work, we combine the capability of free induction decay (FID) navigators, providing information on object motion, with image registration methodology to prospectively--or optionally retrospectively--correct for motion in diffusion imaging of the human brain. Eight healthy subjects were instructed to perform small-scale voluntary head motion during clinical diffusion tensor imaging acquisitions. The implemented motion detection based on FID navigator signals is processed in real-time and provided an excellent detection performance of voluntary motion patterns even at a sub-millimetre scale (sensitivity≥92%, specificity>98%). Motion detection triggered an additional image volume acquisition with b=0 s/mm2 which was subsequently co-registered to a reference volume. In the prospective correction scenario, the calculated motion-parameters were applied to perform a real-time update of the gradient coordinate system to correct for the head movement. Quantitative analysis revealed that the motion correction implementation is capable to correct head motion in diffusion-weighted MRI to a level comparable to scans without voluntary head motion. The results indicate the potential of this method to improve image quality in diffusion-weighted MRI, a concept that can also be applied when highest diffusion weightings are performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The processing of human bodies is important in social life and for the recognition of another person's actions, moods, and intentions. Recent neuroimaging studies on mental imagery of human body parts suggest that the left hemisphere is dominant in body processing. However, studies on mental imagery of full human bodies reported stronger right hemisphere or bilateral activations. Here, we measured functional magnetic resonance imaging during mental imagery of bilateral partial (upper) and full bodies. Results show that, independently of whether a full or upper body is processed, the right hemisphere (temporo-parietal cortex, anterior parietal cortex, premotor cortex, bilateral superior parietal cortex) is mainly involved in mental imagery of full or partial human bodies. However, distinct activations were found in extrastriate cortex for partial bodies (right fusiform face area) and full bodies (left extrastriate body area). We propose that a common brain network, mainly on the right side, is involved in the mental imagery of human bodies, while two distinct brain areas in extrastriate cortex code for mental imagery of full and upper bodies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Der Sammelband ,,Right-wing extremism" hat ein doppeltes Ziel. Zum einen soll er das Nationale Forschungsprogramm 40plus und seine Projekte präsentieren (die alle mit Beiträgen präsent sind), zum anderen sollen diese nationalen Beiträge in eine internationale Perspektive gestellt werden, sodass in der Übersicht und Umschau eine Verortung der schweizerischen Forschung (und damit auch des NFP40plus selbst) und ihrer Resultate möglich wird. Eingeladen wurden dazu führende europäische Forscher auf dem Gebiet des Rechtsextremismus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Early epilepsy is known to worsen the developmental prognosis of young children with a congenital focal brain lesion, but its direct role is often very difficult to delineate from the other variables. This requires prolonged periods of follow-up with simultaneous serial electrophysiological and developmental assessments which are rarely obtained. We studied a male infant with a right prenatal infarct in the territory of the right middle cerebral artery resulting in a left spastic hemiparesis, and an epileptic disorder (infantile spasms with transient right hemihypsarrhythmia and focal seizures) from the age of 7 months until the age of 4 years. Pregnancy and delivery were normal. A dissociated delay of early language acquisition affecting mainly comprehension without any autistic features was documented. This delay was much more severe than usually expected in children with early focal lesions, and its evolution, with catch-up to normal, was correlated with the active phase of the epilepsy. We postulate that the epilepsy specifically amplified a pattern of delayed language emergence, mainly affecting lexical comprehension, reported in children with early right hemisphere damage.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A right heart metastasis of a small-cell lung cancer was found on the whole-body F-fluoro-deoxy-glucose positron emission tomography/computed tomography (F-FDG-PET/CT) of a 69-year-old smoker investigated for a right pulmonary mass discovered on chest radiography after a fracture of the right humerus. The PET scan showed an increased FDG uptake by the mass in the right lung and an intense, atypical focal activity of the right ventricle strongly suggestive of a neoplastic process. CT-guided lung biopsy revealed a small-cell lung cancer and myocardial biopsy confirmed the presence of a cardiac metastasis. The patient was treated with six cycles of chemotherapy followed by radiation therapy, which included the heart lesion. At follow-up PET/CT 2 months after the end of treatment, the abnormal cardiac uptake had disappeared, whereas increased FDG uptake persisted in the pulmonary residual mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Imaging during a period of minimal myocardial motion is of paramount importance for coronary MR angiography (MRA). The objective of our study was to evaluate the utility of FREEZE, a custom-built automated tool for the identification of the period of minimal myocardial motion, in both a moving phantom at 1.5 T and 10 healthy adults (nine men, one woman; mean age, 24.9 years; age range, 21-32 years) at 3 T. CONCLUSION: Quantitative analysis of the moving phantom showed that dimension measurements approached those obtained in the static phantom when using FREEZE. In vitro, vessel sharpness, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were significantly improved when coronary MRA was performed during the software-prescribed period of minimal myocardial motion (p < 0.05). Consistent with these objective findings, image quality assessments by consensus review also improved significantly when using the automated prescription of the period of minimal myocardial motion. The use of FREEZE improves image quality of coronary MRA. Simultaneously, operator dependence can be minimized while the ease of use is improved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a realistic simulator for the Computed Tomography (CT) scan process for motion analysis. In fact, we are currently developing a new framework to find small motion from the CT scan. In order to prove the fidelity of this framework, or potentially any other algorithm, we present in this paper a simulator to simulate the whole CT acquisition process with a priori known parameters. In other words, it is a digital phantom for the motion analysis that can be used to compare the results of any related algorithm with the ground-truth realistic analytical model. Such a simulator can be used by the community to test different algorithms in the biomedical imaging domain. The most important features of this simulator are its different considerations to simulate the best the real acquisition process and its generality.