195 resultados para Merchant vessels.
Resumo:
The formation of new blood vessels (angiogenesis) and lymphatic vessels (lymphangiogenesis) promotes tumor outgrowth and metastasis. Previously, it has been demonstrated that bone marrow-derived cells (BMDC) can contribute to tumor angiogenesis. However, the role of BMDC in lymphangiogenesis has largely remained elusive. Here, we demonstrate by bone marrow transplantation/reconstitution and genetic lineage-tracing experiments that BMDC integrate into tumor-associated lymphatic vessels in the Rip1Tag2 mouse model of insulinoma and in the TRAMP-C1 prostate cancer transplantation model, and that the integrated BMDC originate from the myelomonocytic lineage. Conversely, pharmacological depletion of tumor-associated macrophages reduces lymphangiogenesis. No cell fusion events are detected by genetic tracing experiments. Rather, the phenotypical conversion of myeloid cells into lymphatic endothelial cells and their integration into lymphatic structures is recapitulated in two in vitro tube formation assays and is dependent on fibroblast growth factor-mediated signaling. Together, the results reveal that myeloid cells can contribute to tumor-associated lymphatic vessels, thus extending the findings on the previously reported role of hematopoietic cells in lymphatic vessel formation.
Resumo:
Peripheral venous cannulation is the preferred method of inserting central venous silastic catheters in premature infants. The standard techniques are placement of the catheter using a breakaway introducer needle or introduction of the catheter through a cannula. In extremely low birth weight infants (<1000 g) successful cannulation is impeded by the small size of the vessels. After repeated attempts, both procedures can be time-consuming and stressful to the infant. We present a modified insertion technique of the standard 2-French silastic catheter with an increased success rate, thus reducing insertion time, stress to the infant, and costs. The method uses the tip of a 20-gauge cannula as dilator/introducer for the 2-French catheter. This tip is inserted into the vessel with a standard 24-gauge cannula. After successful insertion of the dilator/introducer cannula, the standard 2-French catheter can then be advanced easily.
Resumo:
Background: The aim of this study was to describe an unexpected phenotype in a family with Leber congenital amaurosis (LCA) due to a retinal pigment epithelium-specific protein 65 kDa (RPE65) homozygous mutation. History and Signs: We analyzed a family from Yemen in which 3 individuals were affected with LCA. Linkage analysis using markers flanking the known LCA genes was done, followed by direct sequencing of RPE65. Therapy and Outcome: Severe visual impairment and night blindness were observed during infancy. We observed photophobia only in the 8-year-old patient. The youngest affected had bilateral hyperopia of + 3.50 and visual acuity of 1/60. The oldest two had visual acuity limited to hand movements in the right eye (OD) and counting fingers in the left eye (OS) for the oldest and of 5/60 OD, 6/60 OS for the other. They showed disc pallor, attenuated vessels, white flecks in the retina mid-periphery and bull's eye maculopathy. ERGs of the oldest child were completely unresponsive. Genomic sequencing identified a novel homozygous missense mutation, IVS2-3C > G, in the second RPE65 intron. Conclusions: We identified a novel LCA-related homozygous RPE65 mutation associated with a severe clinical presentation including an early and severe cone dysfunction. This is in contrast with the presentation associated with other RPE65 mutations predominantly causing rod-cone dystrophy with residual visual function.
Resumo:
The purpose of this study was to investigate the impact of navigator timing on image quality in navigator-gated and real-time motion-corrected, free-breathing, three-dimensional (3D) coronary MR angiography (MRA) with submillimeter spatial image resolution. Both phantom and in vivo investigations were performed. 3D coronary MRA with real-time navigator technology was applied using variable navigator time delays (time delay between the navigator and imaging sequences) and varying spatial resolutions. Quantitative objective and subjective image quality parameters were assessed. For high-resolution imaging, reduced image quality was found as a function of increasing navigator time delay. Lower spatial resolution coronary MRA showed only minor sensitivity to navigator timing. These findings were consistent among volunteers and phantom experiments. In conclusion, for submillimeter navigator-gated and real-time motion-corrected 3D coronary MRA, shortening the time delay between the navigator and the imaging portion of the sequence becomes increasingly important for improved spatial resolution.
Resumo:
BACKGROUND: Clinical studies suggest that transmyocardial laser revascularization may improve regional blood flow of the subendocardial layer. The vascular growth pattern of laser channels was analyzed. METHODS: Twenty pigs were randomized to undergo ligation of left marginal arteries (n = 5), to undergo transmyocardial laser revascularization of the left lateral wall (n = 5), to undergo both procedures (n = 5) or to a control group (n = 5). All the animals were sacrificed after 1 month. Computed morphometric analysis of vascular density of the involved area was expressed as number of vascular structures per square millimeter (+/-1 standard deviation). RESULTS: The vascular density of the scar tissue of the laser channel was significantly increased in comparison with myocardial infarction alone: 49.6+/-12.8/mm2 versus 25.5+/-8.6/mm2 (p < 0.0001). The vascular densities of subendocardial and subepicardial channel areas were similar: 52.9+/-16.8/mm2 versus 46.3+/-13.6/mm2 (p = 0.41). The area immediately adjacent to the channels showed a vascular density similar to that of normal tissue: 6.02+/-1.7/mm2 versus 5.2+/-1.9/mm2 (p = 0.08). In the infarction + transmyocardial laser revascularization group, the channels were indistinguishable from infarction scar. CONCLUSIONS: Scars of transmyocardial laser revascularization channels exhibit an increased vascular density in comparison with scar tissue of myocardial infarction, which does not extend into their immediate vicinity. There was no vascular density gradient along the longitudinal axis of the channels.
Resumo:
Angiogenesis, the development of new blood vessels from preexisting vessels, is a key step in tumor growth, invasion and metastasis formation. Inhibition of tumor angiogenesis is considered as an attractive approach to suppress cancer progression and spreading. Adhesion receptors of the integrin family promote tumor angiogenesis by mediating cell migration, proliferation and survival of angiogenic endothelial cells. Integrins up regulated and highly expressed on neovascular endothelial cells, such as alphaVbeta3 and alpha5beta1, have been considered as relevant targets for anti-angiogenic therapies. Small molecular integrin antagonists or blocking antibodies suppress angiogenesis and tumor progression in many animal models, and some of them are currently being tested in cancer clinical trials as anti-angiogenic agents. COX-2 inhibitors exert anti-cancer effects, at least in part, by inhibiting tumor angiogenesis. We have recently shown that COX-2 inhibitors suppress endothelial cell migration and angiogenesis by preventing alphaVbeta3-mediated and cAMP/PKA-dependent activation of the small GTPases Rac and Cdc42. Here we will review the evidence for the involvement of vascular integrins in mediating angiogenesis and the role of COX-2 metabolites in modulating the cAMP/Protein Kinase A pathway and alphaVbeta3-dependent Rac activation in endothelial cells.
Resumo:
The purpose of this study is to analyze the retina and choroid response following krypton laser photocoagulation. Ninety-two C57BL6/Sev129 and 32 C57BL/6J, 5-6-week-old mice received one single krypton (630 nm) laser lesion: 50 microm, 0.05 s, 400 mW. On the following day, every day thereafter for 1 week and every 2-3 days for the following 3 weeks, serial sections throughout the lesion were systematically collected and studied. Immunohistology using specific markers or antibodies for glial fibrillary acidic protein (GFAP) (astrocytes, glia and Muller's cells), von Willebrand (vW) (vascular endothelial cells), TUNEL (cells undergoing caspase dependent apoptosis), PCNA (proliferating cell nuclear antigen) p36, CD4 and F4/80 (infiltrating inflammatory and T cells), DAPI (cell nuclei) and routine histology were carried out. Laser confocal microscopy was also performed on flat mounts. Temporal and spatial observations of the created photocoagulation lesions demonstrate that, after a few hours, activated glial cells within the retinal path of the laser beam express GFAP. After 48 h, GFAP-positive staining was also detected within the choroid lesion center. "Movement" of this GFAP-positive expression towards the lasered choroid was preceded by a well-demarcated and localized apoptosis of the retina outer nuclear layer cells within the laser beam path. Later, death of retinal outer nuclear cells and layer thinning at this site was followed by evagination of the inner nuclear retinal layer. Funneling of the entire inner nuclear and the thinned outer nuclear layers into the choroid lesion center was accompanied by "dragging" of the retinal capillaries. Thus, from days 10 to 14 after krypton laser photocoagulation onward, well-formed blood capillaries (of retinal origin) were observed within the lesion. Only a few of the vW-positive capillary endothelial cells stained also for PCNA p36. In the choroid, dilatation of the vascular bed occurred at the vicinity of the photocoagulation site and around it. Confocal microscopy demonstrates that the vessels throughout the path lesion are located within the neuroretina while in the choroid (after separation of the neural retina) only GFAP-positive but no lectin-positive cells can be seen. The involvement of infiltrating inflammatory cells in these remodeling and healing processes remained minimal throughout the study period. During the 4 weeks following krypton laser photocoagulation in the mouse eye, processes of wound healing and remodeling appear to be driven by cells (and vessels) originating from the retina.
Resumo:
Aortic access problems due to diseased or small peripheral vessels are a major issue in endovascular aneurysm repair (EVAR). In the emergency setting, like aortic rupture after blunt trauma, or in patients with a hostile abdomen, a more proximal access to the aorta is not a pleasant perspective. We developed in situ introducer sheath dilatation as a bail-out technique for patients with difficult aortic access under various circumstances including EVAR, intra-aortic balloon pump insertion and cannulation for perfusion. The method described allows to increase the access vessel diameter by 50% (from 6 to 9 mm) or the luminal circumference from 18 to 27 F. We have used this technique in five patients without complication, very much in contrast to the traditionally practiced 'forced device insertion'.
Resumo:
At 3 T, the effective wavelength of the RF field is comparable to the dimension of the human body, resulting in B1 standing wave effects and extra variations in phase. This effect is accompanied by an increase in B0 field inhomogeneity compared to 1.5 T. This combination results in nonuniform magnetization preparation by the composite MLEV weighted T2 preparation (T2 Prep) sequence used for coronary magnetic resonance angiography (MRA). A new adiabatic refocusing T2 Prep sequence is presented in which the magnetization is tipped into the transverse plane with a hard RF pulse and refocused using a pair of adiabatic fast-passage RF pulses. The isochromats are subsequently returned to the longitudinal axis using a hard RF pulse. Numerical simulations predict an excellent suppression of artifacts originating from B1 inhomogeneity while achieving good contrast enhancement between coronary arteries and surrounding tissue. This was confirmed by an in vivo study, in which coronary MR angiograms were obtained without a T2 Prep, with an MLEV weighted T2 Prep and the proposed adiabatic T2 Prep. Improved quantitative and qualitative coronary MRA image measurement was achieved using the adiabatic T2 Prep at 3 T.
Resumo:
BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.
Low-pressure environment and remodelling of the forearm vein in Brescia-Cimino haemodialysis access.
Resumo:
BACKGROUND: The aim of the study was to determine which, and to what extent, haemodynamic parameters contribute to the remodelling of the venous limb of the Brescia-Cimino haemodialysis access. METHODS: The dimensions of the radial artery and the venous limb of the haemodialysis access were measured by an echo-tracking technique. In six ESRD patients undergoing primary arteriovenous fistula (AVF) formation, vessel diameter, wall thickness, blood pressure and blood flow were measured after the operation, and at 1 and 3 months follow-up. The contralateral forearm vessels in their native position served as baseline values for comparison. RESULTS: The diameter of the proximal antecubital vein progressively increased over the study period without reaching significant differences (4430, 5041 and 6620 microm at weeks 1, 4 and 12 respectively), whereas the intima-media thickness remained unchanged. The venous dilatation was associated with a reduction of the mean shear stress that culminated after the operation and progressively returned to normal venous values at 3 months (24.5 vs 10.4 dyne/cm(2), P<0.043). Thus the venous limb of the AVF undergoes eccentric hypertrophy as demonstrated by the increase in wall cross-sectional area (4.42 vs 6.32 mm(2) at week 1 vs week 12, P<0.028). At the time of the operation, the blood pressure in the AVF was 151+/-14/92.4+/-11 mmHg vs 49+/-19/24.5+/-6 mmHg (means+/-SEM) for the radial artery and the venous limb of the vascular access, respectively. One year after the operation the blood pressure in the venous limb had not changed: 42+/-14/25.3+/-7 mmHg (means+/-SEM). Under these conditions, the systolo-diastolic diameter changes observed in the radial artery and the antecubital vein were within a similar range at all time points: 56+/-17 vs 90+/-26 microm (means+/-SEM) at week 12. CONCLUSIONS: The increased circumferential stress resulting from the flow-mediated dilatation rather than the elevation of blood pressure appears to represent the main contributing factor to the eccentric hypertrophy of the venous limb of Brescia-Cimino haemodialysis access.
Resumo:
OBJECTIVES: A new caval tree system was designed for realistic in vitro simulation. The objective of our study was to assess cannula performance for virtually wall-less versus standard percutaneous thin-walled venous cannulas in a setting of venous collapse in case of negative pressure. METHODS: For a collapsible caval model, a very flexible plastic material was selected, and a model with nine afferent veins was designed according to the anatomy of the vena cava. A flow bench was built including a lower reservoir holding the caval tree, built by taking into account the main afferent vessels and their flow provided by a reservoir 6 cm above. A cannula was inserted in this caval tree and connected to a centrifugal pump that, in turn, was connected to a reservoir positioned 83 cm above the second lower reservoir (after-load = 60 mmHg). Using the same pre-load, the simulated venous drainage for cardiopulmonary bypass was realized using a 24 F wall-less cannula (Smartcanula) and 25 F percutaneous cannula (Biomedicus), and stepwise increased augmentation (1500 RPM, 2000 and 2500 RPM) of venous drainage. RESULTS: For the thin wall and the wall-less cannulas, 36 pairs of flow and pressure measurements were realized for three different RPM values. The mean Q-values at 1500, 2000 and 2500 RPM were: 3.98 ± 0.01, 6.27 ± 0.02 and 9.81 ± 0.02 l/min for the wall-less cannula (P <0.0001), versus 2.74 ± 0.02, 3.06 ± 0.05, 6.78 ± 0.02 l/min for the thin-wall cannula (P <0.0001). The corresponding inlet pressure values were: -8.88 ± 0.01, -23.69 ± 0.81 and -70.22 ± 0.18 mmHg for the wall-less cannula (P <0.0001), versus -36.69 ± 1.88, -80.85 ± 1.71 and -101.83 ± 0.45 mmHg for the thin-wall cannula (P <0.0001). The thin-wall cannula showed mean Q-values 37% less and mean P values 26% more when compared with the wall-less cannula (P <0.0001). CONCLUSIONS: Our in vitro water test was able to mimic a negative pressure situation, where the wall-less cannula design performs better compared with the traditional thin-wall cannula.
Resumo:
Neuropeptide Y (NPY) is present in the brain, the adrenal medulla, and peripheral sympathetic nerves. This peptide is released together with catecholamines during sympathoadrenal activation. It possesses direct vasoconstrictor properties that are not dependent on simultaneous adrenergic activation. Moreover, it potentiates the vascular effect of several stimulatory substances and may contribute to the modulation of blood pressure responsiveness under a number of circumstances. NPY may also be indirectly involved in the control of blood pressure through regulating the release of hormones with well-established actions on the cardiovascular system.