304 resultados para Internal resonance


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Coronary in-stent restenosis cannot be directly assessed by magnetic resonance angiography (MRA) because of the local signal void of currently used stainless steel stents. The aim of this study was to investigate the potential of a new, dedicated, coronary MR imaging (MRI) stent for artifact-free, coronary MRA and in-stent lumen and vessel wall visualization. METHODS AND RESULTS: Fifteen prototype stents were deployed in coronary arteries of 15 healthy swine and investigated with a double-oblique, navigator-gated, free-breathing, T2-prepared, 3D cartesian gradient-echo sequence; a T2-prepared, 3D spiral gradient-echo sequence; and a T2-prepared, 3D steady-state, free-precession coronary MRA sequence. Furthermore, black-blood vessel wall imaging by a dual-inversion-recovery, turbo spin-echo sequence was performed. Artifacts of the stented vessel segment and signal intensities of the coronary vessel lumen inside and outside the stent were assessed. With all investigated sequences, the vessel lumen and wall could be visualized without artifacts, including the stented vessel segment. No signal intensity alterations inside the stent when compared with the vessel lumen outside the stent were found. CONCLUSIONS: The new, coronary MRI stent allows for completely artifact-free coronary MRA and vessel wall imaging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular magnetic resonance (CMR) has become an important diagnostic imaging modality in cardiovascular medicine. However, insufficient image quality may compromise its diagnostic accuracy. We aimed to describe and validate standardized criteria to evaluate a) cine steady-state free precession (SSFP), b) late gadolinium enhancement (LGE), and c) stress first-pass perfusion images. These criteria will serve for quality assessment in the setting of the Euro-CMR registry. METHODS: Thirty-five qualitative criteria were defined (scores 0-3) with lower scores indicating better image quality. In addition, quantitative parameters were measured yielding 2 additional quality criteria, i.e. signal-to-noise ratio (SNR) of non-infarcted myocardium (as a measure of correct signal nulling of healthy myocardium) for LGE and % signal increase during contrast medium first-pass for perfusion images. These qualitative and quantitative criteria were assessed in a total of 90 patients (60 patients scanned at our own institution at 1.5T (n=30) and 3T (n=30) and in 30 patients randomly chosen from the Euro-CMR registry examined at 1.5T). Analyses were performed by 2 SCMR level-3 experts, 1 trained study nurse, and 1 trained medical student. RESULTS: The global quality score was 6.7±4.6 (n=90, mean of 4 observers, maximum possible score 64), range 6.4-6.9 (p=0.76 between observers). It ranged from 4.0-4.3 for 1.5T (p=0.96 between observers), from 5.9-6.9 for 3T (p=0.33 between observers), and from 8.6-10.3 for the Euro-CMR cases (p=0.40 between observers). The inter- (n=4) and intra-observer (n=2) agreement for the global quality score, i.e. the percentage of assignments to the same quality tertile ranged from 80% to 88% and from 90% to 98%, respectively. The agreement for the quantitative assessment for LGE images (scores 0-2 for SNR <2, 2-5, >5, respectively) ranged from 78-84% for the entire population, and 70-93% at 1.5T, 64-88% at 3T, and 72-90% for the Euro-CMR cases. The agreement for perfusion images (scores 0-2 for %SI increase >200%, 100%-200%,<100%, respectively) ranged from 81-91% for the entire population, and 76-100% at 1.5T, 67-96% at 3T, and 62-90% for the Euro-CMR registry cases. The intra-class correlation coefficient for the global quality score was 0.83. CONCLUSIONS: The described criteria for the assessment of CMR image quality are robust with a good inter- and intra-observer agreement. Further research is needed to define the impact of image quality on the diagnostic and prognostic yield of CMR studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Correction of sagittal and transverse maxillary discrepancies in patients with cleft lip or palate remains a challenge for craniofacial surgeons. Distraction osteogenesis has revolutionized the conceptualization and approach to the craniofacial malformations and has become a reliable and irreplaceable part of the surgical armamentarium. We are reporting a case of sequential maxillary advancement and transpalatal expansion using internal distraction in a patient with unilateral cleft lip and palate presenting with severe maxillary sagittal and transverse deficiencies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Roux-en-Y gastric bypass (RYGBP) is currently the most common bariatric procedure. One of its late complications is the development of internal hernia, which can lead to acute intestinal obstruction or recurrent colicky abdominal pain. The aim of this paper is to present a new, unusual, and so far not reported type of internal hernia. A common computerized database is maintained for all patients undergoing bariatric surgery in our departments. The charts of patients with the diagnosis of internal hernia were reviewed. Three patients were identified who developed acute intestinal obstruction due to an internal hernia located between the jejunojejunostomy and the end of the biliopancreatic limb, directly between two jejunal limbs with no mesentery involved. Another seven patients with intermittent colicky abdominal pain, re-explored for the suspicion of internal hernia, were found to also have an open window of the same location apart from a hernia at one of the typical hernia sites. Since this gap is systematically closed during RYGBP, no other patient has been observed with this problem. Even very small defects can lead to the development of internal hernias after RYGBP. Patients with suggestive symptoms must be explored. Closure of the jejunojejunal defect with nonabsorbable sutures prevents the development of an internal hernia between the jejunal loops at the jejunojejunostomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Recent legislations oblige organizations to monitor the effectiveness of internal control mechanisms that are necessary to prevent fraud. However, little is known about the effectiveness of different internal controls. We investigate whether the duty to sign work results-one of the most prominent internal control mechanisms-is effective to prevent fraud under different superior instructions. We use a 2×2 between-subjects experimental design with accountability (duty to sign work results vs. no duty to sign) and superior instructions (with vs. without profit maximization cue) as independent variables. Both manipulations of superior instructions reminded people to respect accounting standards and principles but in one condition, an instruction to increase revenues was integrated as profit maximization cue. We expected this cue to trigger a profit maximization decision frame that increases the likelihood for fraudulent revenue recording. 58 managers from an executive MBA class participated in the experiment. We find that superior instructions interact with accountability. Fraudulent revenue recording was particularly observed when people received instructions to increase revenues and had to sign their work results. Consequently, fraudulent behavior can occur without pressure to commit fraud due to profit maximization cues that are communicated by a superior and despite implemented internal control mechanisms. We discuss possible implications of our results for the prevention of fraudulent behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: to describe a case in which the diagnosis of Morganian cataract required clinical and instrumental differentiation from iris pathologies, including iris melanoma. Methods: a 60-years-old Caucasian man referred to our institute for worsening of vision in last few months. Clinical evaluation consisted in complete ophthalmological assessment, ultrasound examination (biomicroscopy and 20MHz), and Magnetic Resonance Imaging (MRI) completed with Susceptibility Weighted Imaging (SWI). Results: traumatic corneal wound of the left eye (LE) had occurred 5 years before, and was treated with medical therapy alone. Best-corrected visual acuity (BCVA) was 3/10 in the right eye (RE) and finger count in the LE, with intraocular pressure at 13 and 20mmHg, respectively. Chronic central serous chorioretinopathy, accounted for the low visual acuity of the RE. Slit-lamp biomicroscopy of the LE was as in Figure 1; LE fundus was not clinically observable. Despite MRI was compatible with an iris solid formation, characterized by contrast enhancement and hyperintense signal in SWI, ultrasound indicated rather a mixed solid and liquid content (moderately echogenic external layer, hyporeflective internal content). Iris root and ciliary body were not significantly altered; the lens showed inhomogeneous content. We considered Morgagnian cataract the most probable diagnosis. Surgery confirmed the presence of a hypermature cataract with prior anterior capsule fissuring; the liquefied cortex infiltrated the iris without anterior chamber seeping. Post-operative BCVA was 3/10 and fundus examination disclosed an advanced macular chronic central serous chorioretinopathy. Conclusions: In the reported case a previous perforating trauma have probably damaged the lens capsule and started cataract progression. Curiously cataract developed percolating into the iris stroma, thus simulating an iris mass. At our knowledge, Morgagnian cataract has never been included in the differential diagnosis of iris mass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Cardiovascular magnetic resonance (CMR) is increasingly used in daily clinical practice. However, little is known about its clinical utility such as image quality, safety and impact on patient management. In addition, there is limited information about the potential of CMR to acquire prognostic information. METHODS: The European Cardiovascular Magnetic Resonance Registry (EuroCMR Registry) will consist of two parts: 1) Multicenter registry with consecutive enrolment of patients scanned in all participating European CMR centres using web based online case record forms. 2) Prospective clinical follow up of patients with suspected coronary artery disease (CAD) and hypertrophic cardiomyopathy (HCM) every 12 months after enrolment to assess prognostic data. CONCLUSION: The EuroCMR Registry offers an opportunity to provide information about the clinical utility of routine CMR in a large number of cases and a diverse population. Furthermore it has the potential to gather information about the prognostic value of CMR in specific patient populations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The knowledge in internal medicine is constantly and so rapidly evolving that practices have to be updated and adjusted to recent scientific rules, in order to improve quality and efficiency in the day to day activities. Residents in the Service of internal medicine of the Lausanne University present several relevant papers published in 2012, whose results are susceptible to change the daily hospital practices. From modest impacts to real revolution, a variety of subjects are discussed in the perspective of evidence based medicine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose Carbon-13 magnetic resonance spectroscopy (13C-MRS) is challenging because of the inherent low sensitivity of 13C detection and the need for radiofrequency transmission at the 1H frequency while receiving the 13C signal, the latter requiring electrical decoupling of the 13C and 1H radiofrequency channels. In this study, we added traps to the 13C coil to construct a quadrature-13C/quadrature-1H surface coil, with sufficient isolation between channels to allow simultaneous operation at both frequencies without compromise in coil performance. Methods Isolation between channels was evaluated on the bench by measuring all coupling parameters. The quadrature mode of the quadrature-13C coil was assessed using in vitro 23Na gradient echo images. The signal-to-noise ratio (SNR) was measured on the glycogen and glucose resonances by 13C-MRS in vitro, compared with that obtained with a linear-13C/quadrature-1H coil, and validated by 13C-MRS in vivo in the human calf at 7T. Results Isolation between channels was better than â^'30 dB. The 23Na gradient echo images indicate a region where the field is strongly circularly polarized. The quadrature coil provided an SNR enhancement over a linear coil of 1.4, in vitro and in vivo. Conclusion It is feasible to construct a double-quadrature 13C-1H surface coil for proton decoupled sensitivity enhanced 13C-NMR spectroscopy in humans at 7T. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This study was designed to compare the long-term clinical outcome of coronary artery bypass grafting (CABG) with intracoronary stenting of patients with isolated proximal left anterior descending coronary artery. BACKGROUND: Although numerous trials have compared coronary angioplasty with bypass surgery, none assessed the clinical evaluation in the long term. METHODS: We evaluated the 10-year clinical outcome in the SIMA (Stent versus Internal Mammary Artery grafting) trial. Patients were randomly assigned to stent implantation versus CABG. RESULTS: Of 123 randomized patients, 59 underwent CABG and 62 received a stent (2 patients were excluded). Follow-up after 10 years was obtained for 98% of the randomized patients. Twenty-six patients (42%) in the percutaneous coronary intervention group and 10 patients (17%) in the CABG group reached an end point (p < 0.001). This difference was due to a higher need for additional revascularization. The incidences of death and myocardial infarction were identical at 10%. Progression of the disease requiring additional revascularization was rare (5%) and was similar for the 2 groups. Stent thrombosis occurred in 2 patients (3%). Angina functional class showed no significant differences between the 2 groups. CONCLUSIONS: Both stent implantation and CABG are safe and highly effective in relieving symptoms in patients with isolated, proximal left anterior descending coronary artery stenosis. Stenting with bare-metal stents is associated with a higher need for repeat interventions. The long-term prognosis for these patients is excellent with either mode of revascularization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The knowledge of the national legislation and the key concepts of bioethics are necessary for medical practice. The four principles of bioethics are autonomy, beneficence, non-maleficence, and justice. General internal medicine is the speciality of comprehensive care for often elderly patients with multiple chronic illnesses. This care is related to many ethically difficult decisions. In our article, we discuss common ethical problems in general internal medicine, including ethical aspects of the patient-physician relationship and medical decision making, the ethical significance of time management, research in bioethics and medical education.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Three-dimensional imaging for the quantification of myocardial motion is a key step in the evaluation of cardiac disease. A tagged magnetic resonance imaging method that automatically tracks myocardial displacement in three dimensions is presented. Unlike other techniques, this method tracks both in-plane and through-plane motion from a single image plane without affecting the duration of image acquisition. A small z-encoding gradient is subsequently added to the refocusing lobe of the slice-selection gradient pulse in a slice following CSPAMM acquisition. An opposite polarity z-encoding gradient is added to the orthogonal tag direction. The additional z-gradients encode the instantaneous through plane position of the slice. The vertical and horizontal tags are used to resolve in-plane motion, while the added z-gradients is used to resolve through-plane motion. Postprocessing automatically decodes the acquired data and tracks the three-dimensional displacement of every material point within the image plane for each cine frame. Experiments include both a phantom and in vivo human validation. These studies demonstrate that the simultaneous extraction of both in-plane and through-plane displacements and pathlines from tagged images is achievable. This capability should open up new avenues for the automatic quantification of cardiac motion and strain for scientific and clinical purposes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the year 2005, the chief residents of the University Medical Outpatient Clinic of Lausanne have done a database of useful articles for daily practice, scientifically validated and with excellent didactic quality, from 10 electronic journals. They have used those selected articles in personal meetings between the chief residents on a regular basis and the possibility to access the database by the junior physicians. Six of these articles concerning different topics (depression, tuberculosis detection, anticoagulation at home, cholinesterase inhibitors, insomnia and therapies, transdermal nitroglycerin and tendinopathies) are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To implement and characterize a fluorine-19 ((19)F) magnetic resonance imaging (MRI) technique and to test the hypothesis that the (19)F MRI signal in steady state after intravenous injection of a perfluoro-15-crown-5 ether (PCE) emulsion may be exploited for angiography in a pre-clinical in vivo animal study. MATERIALS AND METHODS: In vitro at 9.4T, the detection limit of the PCE emulsion at a scan time of 10 min/slice was determined, after which the T(1) and T(2) of PCE in venous blood were measured. Permission from the local animal use committee was obtained for all animal experiments. 12 µl/g of PCE emulsion was intravenously injected in 11 mice. Gradient echo (1)H and (19)F images were obtained at identical anatomical levels. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined for 33 vessels in both the (19)F and (1)H images, which was followed by vessel tracking to determine the vessel conspicuity for both modalities. RESULTS: In vitro, the detection limit was ∼400 µM, while the (19)F T(1) and T(2) were 1350±40 and 25±2 ms. The (19)F MR angiograms selectively visualized the vasculature (and the liver parenchyma over time) while precisely coregistering with the (1)H images. Due to the lower SNR of (19)F compared to (1)H (17±8 vs. 83±49, p<0.001), the (19)F CNR was also lower at 15±8 vs. 52±35 (p<0.001). Vessel tracking demonstrated a significantly higher vessel sharpness in the (19)F images (66±11 vs. 56±12, p = 0.002). CONCLUSION: (19)F magnetic resonance angiography of intravenously administered perfluorocarbon emulsions is feasible for a selective and exclusive visualization of the vasculature in vivo.