494 resultados para Imaging biomarkers


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malignant gliomas are currently diagnosed based on morphological criteria and graded according to the World Health Organization classification of primary brain tumors. This algorithm of diagnosis and classification provides clinicians with an estimated prognosis of the natural course of the disease. It does not reflect the expected response to specific treatments beyond surgery (eg, radiotherapy or alkylating chemotherapy). Clinical experience has revealed that gliomas sharing similar histomorphological criteria might indeed have different clinical courses and exhibit highly heterogenous responses to treatments. This was very impressively demonstrated first for oligodendrogliomas. The presence or lack of combined deletions of the chromosomal segments 1p/19q was associated with different benefit from radiotherapy and chemotherapy. We review current molecular markers for malignant gliomas and discuss their current and future impact on clinical neuro-oncology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The number of agents that are potentially effective in the adjuvant treatment of locally advanced resectable colon cancer is increasing. Consequently, it is important to ascertain which subgroups of patients will benefit from a specific treatment. Despite more than two decades of research into the molecular genetics of colon cancer, there is a lack of prognostic and predictive molecular biomarkers with proven utility in this setting. A secondary objective of the Pan European Trials in Adjuvant Colon Cancer-3 trial, which compared irinotecan in combination with 5-fluorouracil and leucovorin in the postoperative treatment of stage III and stage II colon cancer patients, was to undertake a translational research study to assess a panel of putative prognostic and predictive markers in a large colon cancer patient cohort. The Cancer and Leukemia Group B 89803 trial, in a similar design, also investigated the use of prognostic and predictive biomarkers in this setting. In this article, the authors, who are coinvestigators from these trials and performed similar investigations of biomarker discovery in the adjuvant treatment of colon cancer, review the current status of biomarker research in this field, drawing on their experiences and considering future strategies for biomarker discovery in the postgenomic era.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. Results: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. Conclusion: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MRI tractography is the mapping of neural fiber pathways based on diffusion MRI of tissue diffusion anisotropy. Tractography based on diffusion tensor imaging (DTI) cannot directly image multiple fiber orientations within a single voxel. To address this limitation, diffusion spectrum MRI (DSI) and related methods were developed to image complex distributions of intravoxel fiber orientation. Here we demonstrate that tractography based on DSI has the capacity to image crossing fibers in neural tissue. DSI was performed in formalin-fixed brains of adult macaque and in the brains of healthy human subjects. Fiber tract solutions were constructed by a streamline procedure, following directions of maximum diffusion at every point, and analyzed in an interactive visualization environment (TrackVis). We report that DSI tractography accurately shows the known anatomic fiber crossings in optic chiasm, centrum semiovale, and brainstem; fiber intersections in gray matter, including cerebellar folia and the caudate nucleus; and radial fiber architecture in cerebral cortex. In contrast, none of these examples of fiber crossing and complex structure was identified by DTI analysis of the same data sets. These findings indicate that DSI tractography is able to image crossing fibers in neural tissue, an essential step toward non-invasive imaging of connectional neuroanatomy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Early detection is a major goal in the management of malignant melanoma. Besides clinical assessment many noninvasive technologies such as dermoscopy, digital dermoscopy and in vivo laser scanner microscopy are used as additional methods. Herein we tested a system to assess lesional perfusion as a tool for early melanoma detection.¦METHODS: Laser Doppler flow (FluxExplorer) and mole analyser (MA) score (FotoFinder) were applied to histologically verified melanocytic nevi (33) and malignant melanomas (12).¦RESULTS: Mean perfusion and MA scores were significantly increased in melanoma compared to nevi. However, applying an empirically determined threshold of 16% perfusion increase only 42% of the melanomas fulfilled the criterion of malignancy, whereas with the mole analyzer score 82% of the melanomas fulfilled the criterion of malignancy.¦CONCLUSION: Laser Doppler imaging is a highly sensitive technology to assess skin and skin tumor perfusion in vivo. Although mean perfusion is higher in melanomas compared to nevi the high numbers of false negative results hamper the use of this technology for early melanoma detection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Echocardiography is the preferred initial test to assess cardiac morphology and ventricular function. Cardiac MRI enables an optimal visualisation of heart muscle without contrast injection, and precise measurement of the ventricular volumes and systolic function. It is therefore an ideal test for patients with poor echocardiographic windows or for the specific evaluation of right heart chambers. Heart CT also remarkably images heart muscle and precisely measures ventricular systolic function after intravenous injection of iodinated contrast. Coronary CT may also, in selected cases, avoid the need for diagnostic coronary angiography. Although very accurate, these imaging modalities are expensive and may be contra-indicated for a particular patient. Their use in clinical practice has to follow the accepted guidelines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An efficient high-resolution (HR) three-dimensional (3D) seismic reflection system for small-scale targets in lacustrine settings was developed. In Lake Geneva, near the city of Lausanne, Switzerland, the offshore extension of a complex fault zone well mapped on land was chosen for testing our system. A preliminary two-dimensional seismic survey indicated structures that include a thin (<40 m) layer of subhorizontal Quaternary sediments that unconformably overlie south-east-dipping Tertiary Molasse beds and a major fault zone (Paudeze Fault Zone) that separates Plateau and Subalpine Molasse (SM) units. A 3D survey was conducted over this test site using a newly developed three-streamer system. It provided high-quality data with a penetration to depths of 300 m below the water bottom of non-aliased signal for dips up to 30degrees and with a maximum vertical resolution of 1.1 m. The data were subjected to a conventional 3D processing sequence that included post-stack time migration. Tests with 3D pre-stack depth migration showed that such techniques can be applied to HR seismic surveys. Delineation of several horizons and fault surfaces reveals the potential for small-scale geologic and tectonic interpretation in three dimensions. Five major seismic facies and their detailed 3D geometries can be distinguished. Three fault surfaces and the top of a molasse surface were mapped in 3D. Analysis of the geometry of these surfaces and their relative orientation suggests that pre-existing structures within the Plateau Molasse (PM) unit influenced later faulting between the Plateau and SM. In particular, a change in strike of the PM bed dip may indicate a fold formed by a regional stress regime, the orientation of which was different from the one responsible for the creation of the Paudeze Fault Zone. This structure might have later influenced the local stress regime and caused the curved shape of the Paudeze Fault in our surveyed area.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and Aims: Discriminating irritable bowel syndrome (IBS) from inflammatorybowel disease (IBD) can be a clinical challenge as symptoms can overlap. We and othershave recently shown that fecal calprotectin (FC) is more accurate for discriminating IBSfrom IBD compared to C-reactive protein (CRP) and blood leukocytes. Data on the biomarkersused in daily gastroenterological practice are lacking. We therefore aimed to assess whichbiomarkers are used by gastroenterologists in their daily practice for discriminating IBSfrom IBD.Methods: A questionnaire was sent to all board certified gastroenterologists inSwitzerland focusing on demographic informations, number of IBS patients treated in thetime period from May 2009 to April 2010, and the specific biomarkers evaluated fordiscriminating IBS from IBD.Results: Response rate was 57% (153/270). Mean physician'sage was 50±9years, mean duration of gastroenterologic practice 14±8years, 52% of themwere working in private practice and 48% in hospitals. Thirty-nine percent had taken careof more than 100 IBS patients in the last 12 months, 37% had seen 41-100 and 24% hadseen 1-40 IBS patients. Gastroenterologists in private practice more frequently took care ofat least 40 IBS patients in a year compared to hospital-based gastroenterologists (P<0.001).The following biomarkers were determined for discriminating IBS from IBD: CRP 100%,FC 79%, hematogram (red blood cells and leukocytes) 70%, iron status (ferritin, transferrinsaturation) 59%, erythrocyte sedimentation rate 2.7%, protein electrophoresis 0.7%, andalpha-1 antitrypsin clearance 0.7%. There was a trend for using FC more often in privatepractice than in hospital (P = 0.08). Twenty-four percent of gastroenterologists had usedFC in the workup of more than 70% of patients classified as IBS, 22% had used FC in 30-70% of IBS patients, 39% in less than 30%, and 15% had never used FC for the work-upof suspected IBS. Eighty-nine percent of gastroenterologists considered FC to be superiorto CRP for discriminating IBS from IBD, 87% thought that patient's compliance for fecalsampling is high, and 51% judged the fee of USD 60 for a FC test as appropriate.Conclusions:FC is widely used in clinical practice to discriminate IBS from IBD. In accordance with thescientific evidence, the majority of gastroenterologists consider FC to be more accurate thanCRP for discriminating IBS from IBD. Gastroenterologists in private practice take care ofsignificantly more IBS patients than colleagues in hospital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: IOL centration and stability after cataract surgery is of high interest for cataract surgeons and IOL-producing companies. We present a new imaging software to evaluate the centration of the rhexis and the centration of the IOL after cataract surgery.Methods: We developed, in collaboration with the Biomedical Imaging Group (BIG), EPFL, Lausanne, a new working tool in order to assess precisely outcomes after IOL-implantation, such as ideal capsulorhexis and IOL-centration. The software is a plug-in of ImageJ, a general-purpose image processing and image-analysis package. The specifications of this software are: evaluation of the rhexis-centration and evaluation the position of the IOL in the posterior chamber. The end points are to analyze the quality of the centration of a rhexis after cataract surgery, the deformation of the rhexis with capsular bag retraction and the centration of the IOL after implantation.Results: This software delivers tools to interactively measure the distances between limbus, IOL and capsulorhexis and its changes over time. The user is invited to adjust nodes of three radial curves for the limbus, rhexis and the optic of the IOL. The radial distances of the curves are computed to evaluate the IOL implantation. The user is also able to define patterns for ideal capsulorhexis and optimal IOL-centration. We are going to present examples of calculations after cataract surgery.Conclusions: Evaluation of the centration of the rhexis and of the IOL after cataract surgery is an important end point for optimal IOL implantation after cataract surgery. Especially multifocal or accommodative lenses need a precise position in the bag with a good stability over time. This software is able to evaluate these parameters just after the surgery but also its changes over time. The results of these evaluations can lead to an optimizing of surgical procedures and materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Doping with natural steroids can be detected by evaluating the urinary concentrations and ratios of several endogenous steroids. Since these biomarkers of steroid doping are known to present large inter-individual variations, monitoring of individual steroid profiles over time allows switching from population-based towards subject-based reference ranges for improved detection. In an Athlete Biological Passport (ABP), biomarkers data are collated throughout the athlete's sporting career and individual thresholds defined adaptively. For now, this approach has been validated on a limited number of markers of steroid doping, such as the testosterone (T) over epitestosterone (E) ratio to detect T misuse in athletes. Additional markers are required for other endogenous steroids like dihydrotestosterone (DHT) and dehydroepiandrosterone (DHEA). By combining comprehensive steroid profiles composed of 24 steroid concentrations with Bayesian inference techniques for longitudinal profiling, a selection was made for the detection of DHT and DHEA misuse. The biomarkers found were rated according to relative response, parameter stability, discriminative power, and maximal detection time. This analysis revealed DHT/E, DHT/5β-androstane-3α,17β-diol and 5α-androstane-3α,17β-diol/5β-androstane-3α,17β-diol as best biomarkers for DHT administration and DHEA/E, 16α-hydroxydehydroepiandrosterone/E, 7β-hydroxydehydroepiandrosterone/E and 5β-androstane-3α,17β-diol/5α-androstane-3α,17β-diol for DHEA. The selected biomarkers were found suitable for individual referencing. A drastic overall increase in sensitivity was obtained. The use of multiple markers as formalized in an Athlete Steroidal Passport (ASP) can provide firm evidence of doping with endogenous steroids.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this document is to provide general information about mIBG scintigraphy in cancer patients. The guidelines describe the mIBG scintigraphy protocol currently used in clinical routine, but do not include all existing procedures for neuroendocrine tumours. The guidelines should therefore not be taken as exclusive of other nuclear medicine modalities that can be used to obtain comparable results. It is important to remember that the resources and facilities available for patient care may vary from one country to another and from one medical institution to another. The present guidelines have been prepared for nuclear medicine physicians and intend to offer assistance in optimizing the diagnostic information that can currently be obtained from mIBG scintigraphy. The corresponding guidelines of the Society of Nuclear Medicine (SNM) and the Dosimetry, Therapy and Paediatric Committee of the EANM have been taken into consideration, and partially integrated into this text. The same has been done with the most relevant literature on this topic, and the final result has been discussed within a group of distinguished experts.