200 resultados para Current Pulse
Resumo:
BACKGROUND: As the long-term survival of pancreatic head malignancies remains dismal, efforts have been made for a better patient selection and a tailored treatment. Tumour size could also be used for patient stratification. METHODS: One hundred and fourteen patients underwent a pancreaticoduodenectomy for pancreatic adenocarcinoma, peri-ampullary and biliary cancer stratified according to: ≤20 mm, 21-34 mm, 35-45 mm and >45 mm tumour size. RESULTS: Patients with tumour sizes of ≤20 mm had a N1 rate of 41% and a R1/2 rate of 7%. The median survival was 3.4 years. N1 and R1/2 rates increased to 84% and 31% for tumour sizes of 21-34 mm (P = 0.0002 for N, P = 0.02 for R). The median survival decreased to 1.6 years (P = 0.0003). A further increase in tumour size of 35-45 mm revealed a further increase of N1 and R1/2 rates of 93% (P < 0.0001) and 33%, respectively. The median survival was 1.2 years (P = 0.004). Tumour sizes >45 mm were related to a further decreased median survival of 1.1 years (P = 0.2), whereas N1 and R1/2 rates were 87% and 20%, respectively. DISCUSSION: Tumour size is an important feature of pancreatic head malignancies. A tumour diameter of 20 mm seems to be the cut-off above which an increased rate of incomplete resections and metastatic lymph nodes must be encountered and the median survival is reduced.
Resumo:
Pulse oximetry represents a major advance in patient monitoring, but measurement below 70 to 80% saturation has important limitations. Several authors have tested pulse oximetry at low saturations with conflicting results. A review of these data indicates that every patient with a pulse oximeter value below 75 to 80% SaO2 should have one or more invasive measurements of the arterial SaO2 in order to avoid undetected severe hypoxemia.
Resumo:
Anticoagulants are a mainstay of cardiovascular therapy, and parenteral anticoagulants have widespread use in cardiology, especially in acute situations. Parenteral anticoagulants include unfractionated heparin, low-molecular-weight heparins, the synthetic pentasaccharides fondaparinux, idraparinux and idrabiotaparinux, and parenteral direct thrombin inhibitors. The several shortcomings of unfractionated heparin and of low-molecular-weight heparins have prompted the development of the other newer agents. Here we review the mechanisms of action, pharmacological properties and side effects of parenteral anticoagulants used in the management of coronary heart disease treated with or without percutaneous coronary interventions, cardioversion for atrial fibrillation, and prosthetic heart valves and valve repair. Using an evidence-based approach, we describe the results of completed clinical trials, highlight ongoing research with currently available agents, and recommend therapeutic options for specific heart diseases.
Resumo:
OBJECTIVES: To investigate the effect of a change in second-hand smoke (SHS) exposure on heart rate variability (HRV) and pulse wave velocity (PWV), this study utilized a quasi-experimental setting when a smoking ban was introduced. METHODS: HRV, a quantitative marker of autonomic activity of the nervous system, and PWV, a marker of arterial stiffness, were measured in 55 non-smoking hospitality workers before and 3-12 months after a smoking ban and compared to a control group that did not experience an exposure change. SHS exposure was determined with a nicotine-specific badge and expressed as inhaled cigarette equivalents per day (CE/d). RESULTS: PWV and HRV parameters significantly changed in a dose-dependent manner in the intervention group as compared to the control group. A one CE/d decrease was associated with a 2.3 % (95 % CI 0.2-4.4; p = 0.031) higher root mean square of successive differences (RMSSD), a 5.7 % (95 % CI 0.9-10.2; p = 0.02) higher high-frequency component and a 0.72 % (95 % CI 0.40-1.05; p < 0.001) lower PWV. CONCLUSIONS: PWV and HRV significantly improved after introducing smoke-free workplaces indicating a decreased cardiovascular risk.
Resumo:
PURPOSE: To evaluate gadocoletic acid (B-22956), a gadolinium-based paramagnetic blood pool agent, for contrast-enhanced coronary magnetic resonance angiography (MRA) in a Phase I clinical trial, and to compare the findings with those obtained using a standard noncontrast T2 preparation sequence. MATERIALS AND METHODS: The left coronary system was imaged in 12 healthy volunteers before B-22956 application and 5 (N = 11) and 45 (N = 7) minutes after application of 0.075 mmol/kg of body weight (BW) of B-22956. Additionally, imaging of the right coronary system was performed 23 minutes after B-22956 application (N = 6). A three-dimensional gradient echo sequence with T2 preparation (precontrast) or inversion recovery (IR) pulse (postcontrast) with real-time navigator correction was used. Assessment of the left and right coronary systems was performed qualitatively (a 4-point visual score for image quality) and quantitatively in terms of signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, visible vessel length, maximal luminal diameter, and the number of visible side branches. RESULTS: Significant (P < 0.01) increases in SNR (+42%) and CNR (+86%) were noted five minutes after B-22956 application, compared to precontrast T2 preparation values. A significant increase in CNR (+40%, P < 0.05) was also noted 45 minutes postcontrast. Vessels (left anterior descending artery (LAD), left coronary circumflex (LCx), and right coronary artery (RCA)) were also significantly (P < 0.05) sharper on postcontrast images. Significant increases in vessel length were noted for the LAD (P < 0.05) and LCx and RCA (both P < 0.01), while significantly more side branches were noted for the LAD and RCA (both P < 0.05) when compared to precontrast T2 preparation values. CONCLUSION: The use of the intravascular contrast agent B-22956 substantially improves both objective and subjective parameters of image quality on high-resolution three-dimensional coronary MRA. The increase in SNR, CNR, and vessel sharpness minimizes current limitations of coronary artery visualization with high-resolution coronary MRA.
Resumo:
We tested the performance of transcutaneous oxygen monitoring (TcPO2) and pulse oximetry (tcSaO2) in detecting hypoxia in critically ill neonatal and pediatric patients. In 54 patients (178 data sets) with a mean age of 2.4 years (range 1 to 19 years), arterial saturation (SaO2) ranged from 9.5 to 100%, and arterial oxygen tension (PaO2) from 16.4 to 128 mmHg. Linear correlation analysis of pulse oximetry vs measured SaO2 revealed an r value of 0.95 (p less than 0.001) with an equation of y = 21.1 + 0.749x, while PaO2 vs tcPO2 showed a correlation coefficient of r = 0.95 (p less than 0.001) with an equation of y = -1.04 + 0.876x. The mean difference between measured SaO2 and tcSaO2 was -2.74 +/- 7.69% (range +14 to - 29%) and the mean difference between PaO2 and tcPO2 was +7.43 +/- 8.57 mmHg (range -14 to +49 mmHg). Pulse oximetry was reliable at values above 65%, but was inaccurate and overestimated the arterial SaO2 at lower values. TcPO2 tended to underestimate the arterial value with increasing PaO2. Pulse oximetry had the best sensitivity to specificity ratio for hypoxia between 65 and 90% SaO2; for tcPO2 the best results were obtained between 35 and 55 mmHg PaO2.
Resumo:
Autopsy-negative sudden cardiac deaths (SCD) seen in forensic practice are most often thought to be the result of sudden arrhythmic death syndrome. Postmortem genetic analysis is recommended in such cases, but is currently performed in only a few academic centers. In order to determine actual current practice, an on-line questionnaire was sent by e-mail to members of various forensic medical associations. The questions addressed routine procedures employed in cases of sudden cardiac death (autopsy ordering, macroscopic and microscopic cardiac examination, conduction tissue examination, immunohistochemistry and electron microscopy, biochemical markers, sampling and storage of material for genetic analyses, toxicological analyses, and molecular autopsy). Some questions concerned the legal and ethical aspects of genetic analyses in postmortem examinations, as well as any existing multidisciplinary collaborations in SCD cases. There were 97 respondents, mostly from European countries. Genetic testing in cases of sudden cardiac death is rarely practiced in routine forensic investigation. Approximately 60% of respondents reported not having the means to perform genetic postmortem testing and 40% do not collect adequate material to perform these investigations at a later date, despite working at university hospitals. The survey demonstrated that many of the problems involved in the adequate investigation of SCD cases are often financial in origin, due to the fact that activities in forensic medicine are often paid by and dependent on the judicial authorities. Problems also exist concerning the contact with family members and/or the family doctor, as well as the often-nonexistent collaboration with others clinicians with special expertise beneficial in the investigation of SCD cases, such as cardiologists and geneticists. This study highlights the importance in establishing guidelines for molecular autopsies in forensic medicine.
Resumo:
We describe two cases of true dorsalis pedis artery aneurysms in men referred for pulsatile mass of the dorsal part of the foot. Both aneurysms were resected and grafted with interposition of a short segment of saphenous vein. Histological analysis showed true aneurysm associated with atherosclerosis. To our knowledge, only 12 cases of true dorsalis pedis artery aneurysm have been reported previously. On the basis of our experience and after reviewing the literature, the management of this uncommon pathology was discussed.
Resumo:
Background: There may be a considerable gap between LDL cholesterol (LDL-C) and blood pressure (BP) goal values recommended by the guidelines and results achieved in daily practice. Design Prospective cross-sectional survey of cardiovascular disease risk profiles and management with focus on lipid lowering and BP lowering in clinical practice. Methods: In phase 1, the cardiovascular risk of patients with known lipid profile visiting their general practitioner was anonymously assessed in accordance to the PROCAM-score. In phase 2, high-risk patients who did not achieve LDL-C goal less than 2.6 mmol/l in phase 1 could be further documented. Results: Six hundred thirty-five general practitioners collected the data of 23 892 patients with known lipid profile. Forty percent were high-risk patients (diabetes mellitus or coronary heart disease or PROCAM-score >20%), compared with 27% estimated by the physicians. Goal attainment rate was almost double for BP than for LDL-C in high-risk patients (62 vs. 37%). Both goals were attained by 25%. LDL-C values in phase 1 and 2 were available for 3097 high-risk patients not at LDL-C goal in phase 1; 32% of patients achieved LDL-C goal of less than 2.6 mmol/l after a mean of 17 weeks. The most successful strategies for LDL-C reduction were implemented in only 22% of the high-risk patients. Conclusion: Although patients at high cardiovascular risk were treated more intensively than low or medium risk patients, the majority remained insufficiently controlled, which is an incentive for intensified medical education. Adequate implementation of Swiss and International guidelines would expectedly contribute to improved achievement of LDL-C and BP goal values in daily practice.
Resumo:
Three standard radiation qualities (RQA 3, RQA 5 and RQA 9) and two screens, Kodak Lanex Regular and Insight Skeletal, were used to compare the imaging performance and dose requirements of the new Kodak Hyper Speed G and the current Kodak T-MAT G/RA medical x-ray films. The noise equivalent quanta (NEQ) and detective quantum efficiencies (DQE) of the four screen-film combinations were measured at three gross optical densities and compared with the characteristics for the Kodak CR 9000 system with GP (general purpose) and HR (high resolution) phosphor plates. The new Hyper Speed G film has double the intrinsic sensitivity of the T-MAT G/RA film and a higher contrast in the high optical density range for comparable exposure latitude. By providing both high sensitivity and high spatial resolution, the new film significantly improves the compromise between dose and image quality. As expected, the new film has a higher noise level and a lower signal-to-noise ratio than the standard film, although in the high frequency range this is compensated for by a better resolution, giving better DQE results--especially at high optical density. Both screen-film systems outperform the phosphor plates in terms of MTF and DQE for standard imaging conditions (Regular screen at RQA 5 and RQA 9 beam qualities). At low energy (RQA 3), the CR system has a comparable low-frequency DQE to screen-film systems when used with a fine screen at low and middle optical densities, and a superior low-frequency DQE at high optical density.